Loading...
Agenda March 9, 2023M IA M I BEACH Special Magistrate Agenda for: Thursday, March 9, 2023 9:00AM Special Master Case# JB09000417 Department Violation # BV09000409 AREA NONE Description: Comments: SM Initial Hearing Property Address: The Permit Doctor Status: Lien 1925 NORMANDY Violation Type: CONTINUANCE FAILURE TO COMPLY WITH THE REQUIRED RECERTIFICATION OF BUILDING 40 YEAR OLD - MIAMI DADE COUNTY CODE Ordinance Section 8-11(f). Code Code Description [ BV-7036 BV-9991 ENGINEERING MISCELLANEOUS: PLEASE BE ADVISED THAT THIS VIOLATION CASE WILL NOT BE CLOSED UNTIL SUCH TIME THAT ALL BUILDING PERMITS REQUIRED TO CORRECT THE VIOLATION(S) NOTED HAVE BEEN OBTAINED AND FINAL INSPECTION APPROVAL(S) HAVE BEEN GRANTED BY THE CITY OF MIAMI BEACH. 9:00AM Special Master Case# SMB2020-00834 Department Violation # BVC20000540 AREA Fire Inspection Description: Zone 2 Inspector Comments: Adrian Avalos Violation Type: SM Initial Hearing Property Address: 926 MICHIGAN AVE PLAZA CONDOMINIUM Status: Open REQUEST FOR EXTENSION NOTICE OF VIOLATION ISSUED. Evidence of work done without approved permit. Demolition of concrete slab, installation of windows and doors. Need to obtain issued/approved permit(s) and inspections. Double permit fees and $500 penalty applies in the permit fees due to work done without permit. If compliance is not obtained by the due date an additional penalty of $500.00 shall apply. Sec. 8-5. - Unsafe Structures. (a)General. (3)Incomplete buildings commenced without a permit or for which the permit has expired, or completed buildings commenced without a permit or for which the permit has expired, prior to completion and no Certificate of Occupancy has been issued, shall be presumed and deemed unsafe and a permit shall be obtained to demolish the structure or bring the building into compliance with the applicable codes as provided herein. Additional specific details concerning the violation together with photographs can be obtained from the Building Department Violation Section in writing upon request. You have the right to appeal this decision of the Building Official to the Unsafe Structures Board in accordance with Chapter 8, section 8-5 of the Miami-Dade County Code. Failure to comply by the due date will result in the Building Official requesting a hearing before the Unsafe Structures Board on the next available calendar. Unless the decision of the Unsafe Structures Board is appealed, the building or structure shall be demolished without further notice. Violation will not be closed until final inspection is obtained in the related permits to close the case. Code Code Description ; BV-9165 THE CITY OF MIAMI BEACH MUNICIPAL CODE 14-61(b) UNSAFE STRUCTURES- FEES (c) PENAL TY IS IMPOSED WHEN NO PERMIT IS OBTAINED ON WORK FOR WHICH A PERMIT IS REQUIRED. THE APPLICANT SHALL BE REQUIRED TO PAY $500.00 PLUS DOUBLE FEES FOR A PERMIT, AS SPECIFIED HEREIN AS THE COST OF THE PERMIT. THE PAYMENT OF A PERMIT FEE SHALL NOT RELIEVE ANY PERSON, FIRM, OR CORPORATION FROM FULLY COMPLYING WITH THE REQUIREMENTS OF THIS CODE, NOR FROM ANY OTHER PENAL TIES PRESCRIBED THEREIN. q .,,,,,.. 1 '20 ,,,-. // e ,,,.- e /O /O /" 9 12o -- e //- /0 Revised: 2/14/2023 12:29:24 PM Page 1 of 29 M IA M I BEACH 9:00AM S p e c ia l M a s te r C a s e# SMB2020-00896 D e p a rt m e n t V io la tio n # U S 20 2 0 -034 10 AREA Fire In s p e c ti o n Zone 5 In sp ecto r A d rian A v a lo s D e s c rip tio n : S M Initia l He aring P ro p e rty A dd re ss: 7830 D IC K EN S AV E D IC K E N S G A R D E N S C O N D O C /0 JO E , PE C K O Status: Ope n C o m m e n ts : R E Q U E S T FO R EX T E N S IO N (T IM E LY ) Violation Type: 3) N O T IC E O F V IO LA T IO N IS S U E D . P ro cess 40Y R 19 0 13 9 0 not in co m pliance; therefo re, as per the Florida Building C ode and M iam i- D a de C o u nty ch a pt er 8-5 (6 ), the pro perty is deem ed unsafe if a 40Y ear R ecertification report is no t co m ple ted . Y o u m u st ha ve the 40 Y ear R ecert ifica tion. Process(s) needs to be com pleted w ithin thirty ca le nd a r da ys fro m the posting of this notice. P enalty of $500.00 has been applied. S e c. 8-5 . - U nsafe S tructures (6 ), B uild ings or structures subje ct to the recertifica tion requirem ents in Section 8-11(f) of this C o d e w hich the ow ne r fails to tim e ly respond to the Notice of Required Inspection or fails to m ake all re q uire d repa irs or m od ificatio ns fo und to be necessary resulting from the recertifica tion inspe ctio n by the de ad line specifie d in the C o de or any w ritten extension granted by the Building O ffi cia l w ill be de m o lished . -- ----------- ---~---~~- --------------------- ------- ---- Code Code Description [ I B V -70 15 FA IL U R E T O P R O V ID E T H E B U IL DI N G D E P A R TM E N T W IT H TH E R E Q U IR ED R E-C ER TIFIC AT IO N O F O LD ER B U IL DI N G S R E P O R T . 9:00AM S p e c ia l M a s te r C a se # SMB2021-01034 D e p a rt m e n t V io la tio n # B V C 19 000 4 70 AREA Fire Inspection Zone 5 In s p e cto r A d ria n A v a lo s D e s c rip tio n : S M In itia l H e aring P ro p e rty A d d re ss: M IC H A E L R U IZ 7800 C O LLI N S AV E Status: Lien C o m m e n ts : LI E N Violation Type: N O T IC E O F V IO LA T IO N . 78 00 C O LLI N S A V E # 20 1. N o tice of vio la tio n is issued in reference to the bathtub installed in the m aster bedroom . N eed to su b m it the re q uired do cum e nts to obtain approved perm it and inspections to legalize all w ork do ne w itho ut pe rm it, to incl ude all trades involved. If perm it(s) is/are obtained w ithin 07 days no pen a lty sha ll app ly, after 07 days double perm it fees and $500 penalty applies in the perm it(s) fees due to w o rk do ne w itho ut perm it(s). If co m p lia nce is no t obtained by the due date an additional penalty of $500.00 shall apply. S e c. 8-5. - Un s a fe S tructures. (a )G e ne ral. (3 )Incom p lete bu ild ings co m m e nced w itho ut a perm it or fo r w hich the perm it has expired, or co m p le ted build ing s co m m e nced w itho ut a perm it or fo r w hich the perm it has expired, prior to co m ple tio n and no C e rtificate of O ccupancy has been issued, shall be presum ed and deem ed unsafe and a perm it shall be obtained to dem o lish the structure or bring the building into co m p lia nce w ith the app licable codes as provided herein. A dd itio na l speci fic de tails co ncern ing the violation together w ith photographs can be obtained fro m the B uild ing D e pa rtm ent V io lation Section in w riting upon request. Y o u ha ve the rig ht to appe al this decisio n of the Building O ffi ci al to the U nsafe Structures Board in acco rda nce w ith C ha p ter 8, sectio n 8-5 of the M iam i-D ade C ounty C ode. Failure to com ply by the due date w ill resu lt in the Bu ild ing O ffi cial reque sting a hearing befo re the U nsafe Structures B o ard on the ne xt available cale ndar. U nless the decision of the U nsafe Structures Board is ap p ea le d , the bu ild ing or structu re shall be dem olished w ithout further notice. V io la tio n w ill no t be cl o sed until final inspection is obtained in the related perm its to cl ose the case. ----------------------- Code Code Description I V -9 16 5 TH E C ITY O F M IA M I B E A C H M U N IC IP A L C O DE 14 -6 1(b ) U N S AF E STR U C TU R E S- FE ES (c) PEN A LTY IS IM PO SED W H E N N O P E R M IT IS O B TA IN E D O N W O R K FO R W H IC H A P E R M IT IS R EQ U IR E D . TH E A P PLI C A N T SH A LL BE R E Q U IR E D T O P A Y $50 0 .0 0 P L U S D O U B LE FE E S FO R A PE R M IT , A S S P EC IF IE D H E R E IN AS TH E C O ST O F TH E P E R M IT . TH E P A Y M E N T O F A P E R M IT FE E S H A LL N O T R E LI E V E A N Y PE R S O N , FIR M , O R C O R PO R A TIO N FR O M FU L L Y C O M P L Y IN G W IT H TH E R E Q U IR E M E N T S O F TH IS C O D E , N O R FR O M A N Y O TH E R PEN A L TIES PR ESC R IBED TH E R E IN . R ev is ed : 2/14/2023 12:29:24 PM Page 2 of 29 MIAMI BEACH 9:00AM Special Master Case# SMB2021-01069 Department Violation # US2021-03590 AREA Fire Inspection Zone3 Inspector Comments: Adrian Avalos Description: Violation Type: SM Initial Hearing Property Address: 1568 DREXEL AVE ORO 15R LLC - RAZIEL OFER Status: Open PROGRESS REPORT NOTICE OF VIOLATION/ STOPWORK ORDER. 1568 DREXEL AVE. Demolition work in unit 7 in progress without approved permit, need to stop all work immediately, need to submit the required documents to obtain approved permit and inspections for the work in progress. Unit not safe for occupancy, tenant needs to be relocated. Unit cannot be re-occupied until proper permits and inspections are obtained, and Certificate of Completion is approved. A $500.00 fine has been imposed. Sec. 8-5. - Unsafe Structures. (a)General. (3)Incomplete buildings commenced without a permit or for which the permit has expired, or completed buildings commenced without a permit or for which the permit has expired, prior to completion and no Certificate of Occupancy has been issued, shall be presumed and deemed unsafe and a permit shall be obtained to demolish the structure or bring the building into compliance with the applicable codes as provided herein. Additional specific details concerning the violation together with photographs can be obtained from the Building Department Violation Section in writing upon request. You have the right to appeal this decision of the Building Official to the Unsafe Structures Board in accordance with Chapter 8, section 8-5 of the Miami-Dade County Code. Failure to comply by the due date will result in the Building Official requesting a hearing before the Unsafe Structures Board on the next available calendar. Unless the decision of the Unsafe Structures Board is appealed, the building or structure shall be demolished without further notice. Violation will not be closed until final inspection is obtained in the related permits to close the case. Code Code Description [ BV-9165 THE CITY OF MIAMI BEACH MUNICIPAL CODE 14-61(b) UNSAFE STRUCTURES- FEES (c) PENALTY IS IMPOSED WHEN NO PERMIT IS OBTAINED ON WORK FOR WHICH A PERMIT IS REQUIRED. THE APPLICANT SHALL BE REQUIRED TO PAY $500.00 PLUS DOUBLE FEES FOR A PERMIT, AS SPECIFIED HEREIN AS THE COST OF THE PERMIT. THE PAYMENT OF A PERMIT FEE SHALL NOT RELIEVE ANY PERSON, FIRM, OR CORPORATION FROM FULLY COMPLYING WITH THE REQUIREMENTS OF THIS CODE, NOR FROM ANY OTHER PENAL TIES PRESCRIBED THEREIN. 9:00AM Special Master Case# SMB2021-01257 Department Violation# BV14000830 AREA Fine Inspection Description: Zone4 Inspector Comments: Ibrahim Alvarez Violation Type: SM Initial Hearing Property Address: 1825 BIARRITZ DR TOIBE PHILLIPS LE & REM SEAN MICHAEL PHILLIPS Status: Open REQUEST FOR EXTENSION (TIMELY) Stop Work Order issued for enclosure of rear terrace without approved permits. Needs to submit the required documents and obtain approved permits, double fee applies. As per Miami-Dade County Chapter 8-5(3) work done without approved permit is considered unsafe. Need to submit the required documents to obtain approved permit and inspections. If compliance is not obtained by the due date an additional penalty of $500.00 fee will be imposed. (Building Violation) Code Code Description Revised: 2/14/2023 12:29:24 PM Page 3 of 29 M IA M I BEACH 9:00AM Special Master Case# SMB2021-01284 Department Violation # US2016-00169 AREA Fire Inspection Description: Zone 3 Inspector Adrian Avalos Comments: Violation Type: SM Initial Hearing Property Address: 3621 COLLINS AVE ALL SEASONS HOTEL CONDO Status: Open NEW CASE FAILURE TO CLOSE BUILDING VIOLATION BV07000945 AND SPECIAL MASTER CASE JB08000419 IN LIEN STATUS WITH THE AMOUNT OF $238,789.30 NEED TO CLOSE OPEN VIOLATION WITHIN 30 DAYS. FAILURE TO COMPLY IN 30 DAYS SHALL RESULT IN $500.00 PENAL TY AND POWER BEING DISCONNECTED. FOR INFORMATION ON SPECIAL MASTER CASE LIEN JB08000419 PLEASE CONTACT CITY CLERKS'S OFFICE CYNTHIA NEVES AT 305-673-7000 EXTENSI ON 6228. FOR INFORMATION ON BUILDING VIOLATION BV07000945 PLEASE CONTACT THE BUILDING DEPARTMENT VIOLATION SECTION. Code Code Description BV-9150 MIAMI DADE COUNTY MUNICIPAL CODE CHAPTER 8, SECTION 8-5. UNSAFE STRUCTURES - (j) RECOVERY OF COST: 9:00AM Special Master Case# SMB2021-01291 Department Violation # US2017-01638 AREA Fire Inspection Zone 5 Description: Inspector Adrian Avalos Comments: Violation Type: SM Initial Hearing Property Address: 725 84 ST LAND D INVESTORS SUNRISE, INC C/O LEONARD MACHIN Status: Open NEW CASE NOTICE OF VIOLATION ISSUED. Work done without approved permit. New wood fence installation. Need to submit the required documents to obtain approved permit and inspections. Double fee apply. If compliance is not obtained by the due date, penalty of $500.00 shall apply. Sec. 8-5. - Unsafe Structures. (a)General. (3)Incomplete buildings commenced without a permit or for which the permit has expired, or completed buildings commenced without a permit or for which the permit has expired, prior to completion and no Certificate of Occupancy has been issued, shall be presumed and deemed unsafe and a permit shall be obtained to demolish the structure or bring the building into compliance with the applicable codes as provided herein. Additional specific details concerning the violation together with photographs can be obtained from the Building Department Violation Section in writing upon request. You have the right to appeal this decision of the Building Official to the Unsafe Structures Board in accordance w ith Chapter 8, section 8-5 of the Miami-Dade County Code. Failure to comply by the due date w ill result in the Building O ffi ci al requesting a hearing befo re the Unsafe Stru ctures Board on the next available ca lendar. Unless the decision of the Unsafe Structures Board is appealed, the building or structure shall be dem olished without further notice. Violation will not be closed until final inspection is obtained in the related perm its to close the case. - --- --- -- - - ---------- ------- ----------------- Code Code Description I BV -9165 M IA M I DA D E CO U NTY M U NIC IPA L CO D E CHA PTER 8, SEC TI ON 8-12 UN SAF E STR UCTUR E - FEES (c) DO UBLE FEE. W H EN W O RK FO R W HIC H A PER M IT IS REQ UIR ED IS STA RTED PR IO R TO THE O BTA IN IN G O F SA ID PERM IT, TH E A PP LI C A NT FO R A PERM IT SHA LL BE REQ U IR ED TO PA Y $100.00 PLUS DO UBLE THE FEE AS SPEC IFIED HER EIN AS TH E CO ST O F THE PERM IT . THE PA YM ENT O F A PERM IT FEE SHA LL NO T RELI EV E ANY PER SO N FIR M O R CO R PO RA TIO N FR O M FULLY CO M PL YING W ITH THE REQ UIR EM ENTS O F TH IS CO D E, NO R FRO M A NY OTH E R PE NA L TIE S PR ESC RIB ED TH ER EIN . Revised: 2/14/2023 12:29:24 PM Page 4 of 29 M IA M I B E A C H 9:00AM Special Master Case# SMB2021-01296 Department Violation# US2017-01871 AREA Fire Inspection Zone 1 Description: Comments: Violation Type: SM Initial Hearing Property Address: 25 N HIBISCUS DR EDWARD R DANIEL TRS, DANIEL FAMILY TRUST & JUDITH DANIEL TRS Status: Open NEW CASE Main Electrical service affected, need to repair and obtain permit to authorize reconnection. Code Code Description I BV-9005 MIAMI-DADE COUNTY MUNICIPAL CODE CHAPTER 8, SECTION 8-5- UNSAFE STRUCTURES - (a) GENERAL (1) THE UNSAFE STRUCTURES BOARD IS CREATED TO EXERCISE THROUGHOUT THE INCORPORATED AND UNINCORPORATED AREAS OF MIAMI-DADE COUNTY THE POWERS AND DUTIES GRANTED BY THIS SECTION. THE BOARD SHALL HAVE EXCLUSIVE JURISDICTION IN BOTH THE INCORPORATED AND UNINCORPORATED AREAS OF MIAMI-DADE COUNTY WITH RESPECT TO ITS POWERS, DUTIES AND FUNCTIONS. THE BOARD SHALL BE ENTRUSTED WITH HEARING APPEALS OF DECISIONS OF BUILDING OFFICIALS DECLARING STRUCTURES TO BE UNSAFE WHERE THERE IS AN IMMEDIATE DANGER TO THE HEAL TH AND SAFETY OF THE CITIZENS, ALL IN THE MANNER PRESCRIBED IN THIS SECTION. 9:00AM Special Master Case# SMB2021-01306 Department Violation# US2021-03611 AREA Fire Inspection Description: Zone 1 Inspector Adrian Avalos Comments: Violation Type: SM Initial Hearing Property Address: 345 OCEAN DR OCEAN POINT CONDO Status: Open NEW CASE NOTICE OF VIOLATION ISSUED. 345 OCEAN DR. Notice of violation is in reference to the evidence of water intrusion observed coming through water riser floor penetration in unit 604. Need to submit an engineer's report, signed and sealed by a professional engineer to determine the source of the water intrusion along with methods of repair. Need to submit a mold report together with methods of repair. Need to obtain approved permits and call final inspections. Additional specific details concerning the violation together with photographs can be obtained from the Building Department Violation Section in writing upon request. You have the right to appeal this decision of the Building Official to the Unsafe Structures Board in accordance with Chapter 8, section 8-5 of the Miami-Dade County Code. Failure to comply by the due date will result in the Building Official requesting a hearing before the Unsafe Structures Board on the next available calendar. Unless the decision of the Unsafe Structures Board is appealed, the building or structure shall be demolished without further notice. Violation will not be closed until final inspection is obtained in the related permits to close the case. If compliance is not obtained by compliance date; penalty of $500.00 shall apply. ------ ------------------ -- --------~ ----~ ------ Code Code Description BV-9005 MIAMI-DADE COUNTY MUNICIPAL CODE CHAPTER 8, SECTION 8-5-UNSAFE STRUCTURES - (a) GENERAL (1) THE UNSAFE STRUCTURES BOARD IS CREATED TO EXERCISE THROUGHOUT THE INCORPORATED AND UNINCORPORATED AREAS OF MIAMI-DADE COUNTY THE POWERS AND DUTIES GRANTED BY THIS SECTION. THE BOARD SHALL HAVE EXCLUSIVE JURISDICTION IN BOTH THE INCORPORATED AND UNINCORPORATED AREAS OF MIAMI-DADE COUNTY WITH RESPECT TO ITS POWERS, DUTIES AND FUNCTIONS. THE BOARD SHALL BE ENTRUSTED WITH HEARING APPEALS OF DECISIONS OF BUILDING OFFICIALS DECLARING STRUCTURES TO BE UNSAFE WHERE THERE IS AN IMMEDIATE DANGER TO THE HEALTH AND SAFETY OF THE CITIZENS, ALL IN THE MANNER PRESCRIBED IN THIS SECTION. Revised: 2/14/2023 12:29:24 PM Page 5 of 29 M IA M I BEACH 9:00AM Special Master Case# SMB2021-01317 Department Violation# US2020-03515 AREA Fire Inspection Zone 5 Inspector Adrian Avalos Description: SM Initial Hearing Property Address: 337 71ST PW GLOBAL SERVICES INC - SOLON PEREIRA Status: Open Comments: NEW CASE Violation Type: NOTICE OF VIOLATION ISSUED. 337 71 ST. Process 40YR1901456 is not in compliance, therefore, as per the Florida Building Code and Miami-Dade County chapter 8-5 (6) the property is deemed unsafe if a 40 Year Recertification report is not completed. You must have the 40 Year Rec. processes completed within thirty calendar days from the posting of this notice. Sec. 8-5. - Unsafe Structures (6) Buildings or structures subject to the recertification requirements in Section 8-11(f) of this Code which the owner fails to timely respond to the Notice of Required Inspection or fails to make all required repairs or modifications found to be necessary resulting from the recertification inspection by the deadline specified in the Code or any written extension granted by the Building Official will be demolished. ------ ---- - --- --------- ------- -- --- ----------- --- ---------- Code Code Description , BV-7015 FAILURE TO PROVIDE THE BUILDING DEPARTMENT WITH THE REQUIRED RE-CERTIFICATION OF OLDER BU ILD ING S REPO RT. 9:00AM Special Master Case# SMB2021-0 1334 Department Violation # BV 14000322 AREA Fire Inspe ction Zone3 Description: SM Initial Hearing Property Address: 3621 COLLINS AVE ALL SEA SONS CONDOMINIUM ASSOCIATION, INC. Status: Open Comments: NEW CA SE Violation Type: NO TIC E O F VIO LA TIO N ISSUED.Metal door has been installed at fire exit stair without approved permit. Need to submit the required documents to obtain approved permit, or need to remove doors. Double fees apply. (Building Violation) Code Code Description [ Revised: 2/14/2023 12:29:24 PM Page 6 of 29 M IA M I BEACH 10:00AM Special Master Case# SMB2021-01285 Department Violation# US2018-02869 AREA Fire Inspection Description: Zone 1 Inspector Comments: Adrian Avalos Violation Type: SM Initial Hearing Property Address: 635 EUCLID AVE VILLAS AT SOUTH BEACH CONDOMINIUM ASSOC INC. Status: Open NEW CASE I~ NOTICE OF VIOLATION ISSUED. 635 EUCLID AVE. There is evidence of water intrusion in unit 114. Need to submit an engineer's report to identify source of water intrusion along with methods of repair. As per Miami-Dade County Chapter 8-5(2) occupied building with unsanitary conditions is considered unsafe. Property cannot be occupied. Additional specific details concerning the violation together with photographs can be obtained from the Building Department Violation Section in writing upon request. You have the right to appeal this decision of the Building Official to the Unsafe Structures Board in accordance with Chapter 8, section 8-5 of the Miami-Dade County Code. Failure to comply by the due date will result in the Building Official requesting a hearing before the Unsafe Structures Board on the next available calendar. Unless the decision of the Unsafe Structures Board is appealed, the building or structure shall be demolished without further notice. Violation will not be closed until final inspection is obtained in the related permits to close the case. 11/29/2018- adding to violation as per chief Avalos - evidence of deterioration and signs of water damage through building - refer to pictures dated 11/28/2018. Code Code Description 1 BV-9005 MIAM I-DADE COUNTY MUNICIPAL CODE CHAPTER 8, SECTION 8-5 -UN SAFE STRUCTURES- (a) GENERAL (1) THE UNSAFE STRUCTURES BOARD IS CREATED TO EXERCISE THROUGHOUT THE INCORPORATED AND UNINCORPORA TED AREAS OF MIAMI-DADE COUNTY THE POWERS AND DUTIES GRANTED BY THIS SECTION. THE BOARD SHALL HAVE EXCLUSIVE JURISDICTION IN BOTH THE INCORPORATED AND UNINCORPORATED AREAS OF MIAM I-DADE COUNTY WITH RESPECT TO ITS POWERS, DUTIES AND FUNCTIONS. THE BOARD SHALL BE ENTRUSTED WITH HEARING APPEALS OF DECISIONS OF BUILDING OFFICIALS DECLARING STRUCTURES TO BE UNSAFE WHERE THERE IS AN IMMEDIATE DANGER TO THE HEAL TH AND SAFETY OF THE CITIZENS, ALL IN THE MANNER PRESCRIBED IN THIS SECTION. Revised: 2/14/2023 12:29:24 PM Page 7 of 29 M IA M I BEACH 10:00AM Special Master Case# SMB2021-01293 Department Violation # Property Address: 624 83 ST AREA Fire Inspection Zone 5 Description: SM Initial Hearing ERAN FRAI & W ELISABETH Status: Open Comments: NEW CASE Violation Type: ) NO TIC E O F VI OL A TI ON -624 83R D ST Evidence of work done w ithout perm it; Roof replacem ent ale units replacem ent, new lights. Need to hire a contractor able to obtain an approved perm it and final inspections. Need to subm it the required docum ents to obtain approved permit(s) and inspections. Double permit fees and $500 penalty applies in the permit fees due to work done without permit. If compliance is not obtained by the due date an additional penalty of $500.00 shall apply. Sec. 8-5. - Unsafe Structures. (a)G eneral. (3)1ncom plete buildings commenced without a permit or for which the permit has expired, or completed buildings commenced without a permit or for which the permit has expired, prior to completion and no Certificate of Occupancy has been issued, shall be presumed and deemed unsafe and a permit shall be obtained to demolish the structure or bring the building into compliance with the applicable codes as provided herein. Additional specific details concerning the violation together with photographs can be obtained from the Building Department Violation Section in writing upon request. You have the right to appeal this decision of the Building Official to the Unsafe Structures Board in accordance with Chapter 8, section 8-5 of the Miami-Dade County Code. Failure to comply by the due date will result in the Building Official requesting a hearing before the Unsafe Structures Board on the next available calendar. Unless the decision of the Unsafe Structures Board is appealed, the building or structure shall be demolished without further notice. Violation will not be closed until final inspection is obtained in the related permits to close the case. - -- ---------------------------- -------- Code Code Description BV-9165 THE CITY OF MIAMI BEACH MUNICIPAL COD E 14-61(b) UNSAFE STRUCTURES- FEES (c) PENAL TY IS IMPOSED WHEN NO PERMIT IS OBTAINED ON WORK FOR WHICH A PERMIT IS REQUIRED. THE APPLICANT SHALL BE REQUIRED TO PAY $500.00 PLUS DOUBLE FEES FOR A PERMIT, AS SPECIFIED HEREIN AS THE COST OF THE PERMIT. THE PAYMENT OF A PERMIT FEE SHALL NOT RELIEVE ANY PERSON, FIRM, OR CORPORA TION FROM FULLY COMPLYING WITH THE REQUIREMENTS OF THIS CODE, NOR FROM ANY OTHER PENAL TIES PRESCRIBED THEREIN. Revised: 2/14/2023 12:29:24 PM Page 8 of 29 M IA M I BEACH 10:00AM Special Master Case# SMB2021-01294 Department Violation# BVC18000041 AREA Fire Inspection Zone 3 Description: SM Initial Hearing Property Address: 3621 COLLINS AVE ALL SEASONS HOTEL CONDO Status: Open Inspector Comments: Adrian Avalos Violation Type: NEW CASE NOTICE OF VIOLATION ISSUED. Evidence of work done without approved permit. First floor area converted to living space, electrical connections done that break the fire rated conditions. Need to submit the required documents to obtain approved permit and inspections. If compliance is not obtained by the due date penalty of $500.00 shall apply. Sec. 8-5. - Unsafe Structures. (a)General. (3)Incomplete buildings commenced without a permit or for which the permit has expired, or completed buildings commenced without a permit or for which the permit has expired, prior to completion and no Certificate of Occupancy has been issued, shall be presumed and deemed unsafe and a permit shall be obtained to demolish the structure or bring the building into compliance with the applicable codes as provided herein. Additional specific details concerning the violation together with photographs can be obtained from the Building Department Violation Section in writing upon request. You have the right to appeal this decision of the Building Official to the Unsafe Structures Board in accordance with Chapter 8, section 8-5 of the Miami-Dade County Code. Failure to comply by the due date will result in the Building Official requesting a hearing before the Unsafe Structures Board on the next available calendar. Unless the decision of the Unsafe Structures Board is appealed, the building or structure shall be demolished without further notice. Violation will not be closed until final inspection is obtained in the related permits to close the case. ------ ---- - ---------------- ---------- - ------------ Code - Code Description [ BV-9005 MIAMI-DADE COUNTY MUNICIPAL CODE CHAPTER 8, SECTION 8-5 - UNSAFE STRUCTURES - (a) GENERAL (1) THE UNSAFE STRUCTURES BOARD IS CREATED TO EXERCISE THROUGHOUT THE INCORPORATED AND UNINCORPORATED AREAS OF MIAMI-DADE COUNTY THE POWERS AND DUTIES GRANTED BY THIS SECTION. THE BOARD SHALL HAVE EXCLUSIVE JURISDICTION IN BOTH THE INCORPORATED AND UNINCORPORATED AREAS OF MIAMI-DADE COUNTY WITH RESPECT TO ITS POWERS, DUTIES AND FUNCTIONS. THE BOARD SHALL BE ENTRUSTED WITH HEARING APPEALS OF DECISIONS OF BUILDING OFFICIALS DECLARING STRUCTURES TO BE UNSAFE WHERE THERE IS AN IMMEDIATE DANGER TO THE HEAL TH AND SAFETY OF THE CITIZENS, ALL IN THE MANNER PRESCRIBED IN THIS SECTION. Revised: 2/14/2023 12:29:24 PM Page 9 of 29 M IA M I B E A C H 10:00AM Special Master Case# SMB2021-01295 Department Violation # BVC21000730 AREA Fire Inspection Zone 3 Inspector Adrian Avalos Description: SM Initial Hearing Property Address: 1606 JEFFERSON AVE PROKOPIOS PANAGAKOS Status: Open Comments: NEW CASE Violation Type: STOP WORK ORDER. 1606 JEFF ERSON AVE# 2. Notice of violation is in reference to the interior demolition occurring throughout the unit, without obtaining approved perm its. Need to stop all work being done. Need to obtain approved permits and call for final inspections. Notice of violation will not be closed until the permit(s) is put on finaled status. If compliance is not obtained by the due date, double permit fees and $500 penalty applies in the permit(s) fees due to work done without permit(s). Sec. 8-5. - Uns afe Structures. (a)General. (3)Incomplete buildings commenced without a permit or for which the permit has expired, or completed buildings commenced without a permit or for which the permit has expired, prior to completion and no Certificate of Occupancy has been issued, shall be presumed and deemed unsafe and a permit shall be obtained to demolish the structure or bring the building into compliance with the applicable codes as provided herein. Additional specific details concerning the violation together with photographs can be obtained from the Building Department Violation Section in writing upon request. You have the right to appeal this decision of the Building Official to the Unsafe Structures Board in accordance with Chapter 8, section 8-5 of the Miami-Dade County Code. Failure to comply by the due date will result in the Building Official requesting a hearing before the Unsafe Structures Board on the next available calendar. Unless the decision of the Unsafe Structures Board is appealed, the building or structure shall be demolished without further notice. Violation will not be closed until final inspection is obtained in the related permits to close the case. Code Code Description BV-9165 THE CITY OF MIAMI BEA CH MUNICIPAL CODE 14-61(b) UNSAFE STRUCTURES- FEES (c) PENAL TY IS IMPOSED WHEN NO PERMIT IS OBTAINED ON WORK FOR WHICH A PERMIT IS REQUIRED. THE APPLICANT SHALL BE REQUIRED TO PAY $500 .00 PLUS DOUBLE FEES FOR A PERMIT, AS SPECIFIED HEREIN AS THE COST OF THE PERMIT. THE PAYMENT OF A PERMIT FEE SHALL NOT RELIEVE ANY PERSON, FIRM, OR CORPORA TION FROM FULLY COMPLYING WITH THE REQUIREMENTS OF THIS CODE, NOR FROM ANY OTHER PENAL TIES PRESCRIBED THEREIN. 10:00AM Special Master Case# SMB2021-01299 Department Violation # US2018-02832 AREA Fire Inspection Zone 1 Inspector Adrian Avalos Description: SM Initial Hearing Property Address: 900 6TH ST ACADEMY APARTMENTS CONDO, INC. OF MIAMI BEACH Status: Open Comments: NEW CASE Violation Type: NOTICE OF VIOLA TION ISSUED. Process 40YR1700535 not in compliance; therefore, as per the Florida Building Code and Miami- Dade County chapter 8-5 (6), the property is deemed unsafe if a 40Year Recertifica tion report is not completed. You must have the 40Year Recertification. Process(s) completed within thirty ca lendar days from the posting of this notice. Penalty of $500.00 shall apply Sec. 8-5. - Unsafe Structures (6), Buildings or structures subject to the recertifica tion requirements in Section 8-11(f) of this Code which the owner fails to timely respond to the Notice of Required Inspection or fails to make all required repairs or modifications found to be necessary resulting from the recertification inspection by the deadline specified in the Code or any written extension granted by the Building Official will be demolished. ~ -- -------- Code Code Description I BV-7015 FAILURE TO PROVIDE THE BUILDING DEPARTMENT WITH THE REQUIRED RE-CERTIFICATION OF OLDER BUILDINGS REPORT. Revised: 2/14/2023 12:29:24 PM Page 10 of 29 M IA M I BEACH 10:00AM Special Master Case# SMB2021-01300 Department Violation# BVC19000378 AREA Fire Inspection Zone2 Inspector Adrian Avalos Description: SM Initial Hearing Property Address: 928 OCEAN DR PARK ADULT RESIDENTIAL LLC Status: Open Comments: NEW CASE Violation Type: I NOTICE OF VIOLATION ISSUED. Improper use of equipment installed without permit, extractor/ kitchen hood. Need to remove equipment. Need to obtain approved permit and inspection to install the correct equipment as per the Florida Building Code. If compliance is not obtained by the due date an additional penalty of $500.00 shall apply. Sec. 8-5. - Unsafe Structures. (a)General. (3)Incomplete buildings commenced without a permit or for which the permit has expired, or completed buildings commenced without a permit or for which the permit has expired, prior to completion and no Certificate of Occupancy has been issued, shall be presumed and deemed unsafe and a permit shall be obtained to demolish the structure or bring the building into compliance with the applicable codes as provided herein. Additional specific details concerning the violation together with photographs can be obtained from the Building Department Violation Section in writing upon request. You have the right to appeal this decision of the Building Official to the Unsafe Structures Board in accordance with Chapter 8, section 8-5 of the Miami-Dade County Code. Failure to comply by the due date will result in the Building Official requesting a hearing before the Unsafe Structures Board on the next available calendar. Unless the decision of the Unsafe Structures Board is appealed, the building or structure shall be demolished without further notice. Violation will not be closed until final inspection is obtained in the related permits to close the case. -- --------- ---- ----------------------- -~ ------------------- - Code Code Description I BV-9165 THE CITY OF MIAMI BEACH MUNICIPAL CODE 14-61(b) UNSAFE STRUCTURES- FEES (c) PENALTY IS IMPOSED WHEN NO PERMIT IS OBTAINED ON WORK FOR WHICH A PERMIT IS REQUIRED. THE APPLICANT SHALL BE REQUIRED TO PAY $500.00 PLUS DOUBLE FEES FOR A PERMIT, AS SPECIFIED HEREIN AS THE COST OF THE PERMIT. THE PAYMENT OF A PERMIT FEE SHALL NOT RELIEVE ANY PERSON, FIRM, OR CORPORATION FROM FULLY COMPLYING WITH THE REQUIREMENTS OF THIS CODE, NOR FROM ANY OTHER PENAL TIES PRESCRIBED THEREIN. Special Master Case# SMB2021-01301 10:00AM AREA Fire Inspection Zone 5 Inspector Adrian Avalos Description: Comments: cw. -<gt of 0 1'e TION ISSUED.BR150337 not in complia~er~!:~d: r.eA""'-£ I Building and Miami-Dade County chapter 8-5 (6) the property is deemed unsafe if a 40 Year • e,_ Recer (cation report is not completed.You must have the 40 Year Rec. processes completed e " in thirty calendar days from the posting of this notice. Sec. 8-5. - Unsafe Structures(6) Buildings or structures subject to the recertification requirements in Section 8-11(f) of this Code which the owner fails to timely respond to the Notice of Required Inspection or fails to make all required repairs or modifications found to be necessary resulting from the recertification inspection by the deadline specified in the Code or any written extension granted by the Building Official will be demolished (Building Violation) You must have the 40Year Recertification. Process(s) completed within thirty calendar days from the posting of this notice. Penalty of $500.00 shall apply Property Address: 8035 ABBOTT AV Violation Type: Department Violation# BV16000267 SM Initial Hearing NEW CASE Co~-- Code Description ---------- ----------- - --! ' B\V-9145 MIAMI DADE COUNTY MUNICIPAL CODE CHAPTER 8, SECTION 8-5. UNSAFE STRUCTURES - () MUL Tl-UNIT STRUCTURES Revised: 2/14/2023 12:29:24 PM Page 11 of 29 M IA M I BEACH 10:00AM Special Master Case# SMB2021-01302 Department Violation# BV16000420 AREA Fine Inspection Description: Zone4 Inspector Adrian Avalos Comments: Violation Type: SM Initial Hearing Property Address: 4525 COLLINS AVE EDEN ROC LLLP Status: Open NEW CASE NOTICE OF VIOLATION ISSUED. 4525 COLLINS AVE. Process 40YR2016-00264 is not in compliance, therefore, as per the Florida Building Code and Miami-Dade County chapter 8-5 (6) the property is deemed unsafe if a 40 Year Recertification report is not completed. A recent inspection report must be submitted within 14 days. this report is to be signed and sealed by a Florida Licensed design professional and must detail the conditions of the structural and electrical systems for the referenced address. If the professional inspection report finds deficiencies that require correction the Florida Licensed design professional MUST provide a cover letter indicating if the building can remain occupied. Failure to provide this report will result in escalating this violation into Special Master Hearing, Unsafe Structure Board, and including vacating the structure. Sec. 8-5. - Unsafe Structures (6) Buildings or structures subject to the recertification requirements in Section 8-11(f) of this Code which the owner fails to timely respond to the Notice of Required Inspection or fails to make all required repairs or modifications found to be necessary resulting from the recertification inspection by the deadline specified in the Code or any written extension granted by the Building Official will be demolished. Code Code Description BV-7015 FAILURE TO PROVIDE THE BUILDING DEPARTMENT WITH THE REQUIRED RE-CERTIFICATION OF OLDER BUILDINGS REPORT. 10:00AM Special Master Case# SMB2021-01337 Department Violation# BVB21001289 AREA Fire Inspection Description: Zone 5 Inspector Comments: Ibrahim Alvarez Violation Type: SM Initial Hearing Property Address: 1125 MARSEILLE DR TL G ENTERPRISES, INC. Status: Open NEW CASE NOTICE OF VIOLATION. 1125 MARSEILLE DR. Notice of violation is reference to the installation of new floor tile in unit 6A without an approved permit. Need to obtain approved permit(s) and call for inspections. If compliance is not obtained by the due date, double permit fees and $500 penalty applies in the permit(s) fees due to work done without permit(s). Sec. 8-5. - Unsafe Structures. (a)General. (3)Incomplete buildings commenced without a permit or for which the permit has expired, or completed buildings commenced without a permit or for which the permit has expired, prior to completion and no Certificate of Occupancy has been issued, shall be presumed and deemed unsafe and a permit shall be obtained to demolish the structure or bring the building into compliance with the applicable codes as provided herein. Additional specific details concerning the violation together with photographs can be obtained from the Building Department Violation Section in writing upon request. You have the right to appeal this decision of the Building Official to the Unsafe Structures Board in accordance with Chapter 8, section 8-5 of the Miami-Dade County Code. Failure to comply by the due date will result in the Building Official requesting a hearing before the Unsafe Structures Board on the next available calendar. Unless the decision of the Unsafe Structures Board is appealed, the building or structure shall be demolished without further notice. Violation will not be closed until final inspection is obtained in the related permits to close the case. --- - ----------------~~ 7 Code Code Description BV-9165 TH E CITY OF MIAMI BEACH MUNICIPAL CODE 14-61(b) UNSAFE STRUCTURES- FEES (c) PENALTY IS IMPOSED WHEN NO PERMIT IS OBTAINED ON WORK FOR WHICH A PERMIT IS REQUIRED. THE APPLICANT SHALL BE REQUIRED TO PAY $500.00 PLUS DOUBLE FEES FOR A PERMIT, AS SPECIFIED HEREIN AS THE COST OF THE PERMIT. THE PAYMENT OF A PERMIT FEE SHALL NOT RELIEVE ANY PERSON, FIRM, OR CORPORATION FROM FULLY COMPLYING WITH TH E REQUIREMENTS OF THIS CODE, NOR FROM ANY OTHER PENAL TIES PRESCRIBED THEREIN. Revised: 2/14/2023 12:29:24 PM Page 12 of 29 M IA M I BEACH 10:00AM Special Master Case# SMB2022-01535 Department Violation # US2021-03806 AREA Fire Inspection Description: Z one 5 Inspector Comments: Ibrahim A lvarez Violation Type: SM Initial Hearing Property Address: 7741 HAWT HORNE AVE LIONS DEN GLOBAL DEVELOPMENT LLC Status: Open NEW CA SE NO TIC E O F VIO LATION ISSUED. Pro cess 40YR 1901355 not in com pliance; therefore, as per the Florida Building Code and Miami- Dade County chapter 8-5 (6), the property is deemed unsafe if a 40Year Recertification report is not completed. You must have the 40Year Recertification. Process(s) completed within thirty calendar days from the posting of this notice. Penalty of $500.00 shall apply Sec. 8-5. - Unsafe Structures (6), Buildings or structures subject to the recertification requirements in Section 8-11(f) of this Code which the ow ner fails to tim ely respond to the Notice of Required Inspection or fails to make all required repairs or modifications found to be necessary resulting from the recertification inspection by the deadline specified in the Code or any written extension granted by the Building Official will be demolished. Code Code Description I BV-7015 FAILURE TO PROVIDE THE BUILDING DEPARTMENT WITH THE REQUIRED RE-CERTIFICATION OF OLDER BUILDINGS REPORT. 11:00AM Special Master Case# SMB2019-00596 Department Violation # US2019-03013 AREA North Beach, Zone 1 Inspector Adrian Avalos Description: SM Initial Hearing Property Address: DEBBY DARBY 7330 BYRON AVENUE Status: Open Comments: REQ UEST FO R HEA R ING Violation Type: NOTICE OF VIOLATION. 7330 BYRON AVE# 8. Evidence of w ork done without approved permit. Notice of violation is in reference to the reconfiguration of the 2nd floor. Kitchen has been added, a wall was plastered to separate the unit and a floor was installed to create a new unit. Double permit fees apply. Need to submit required documents to obtain a permit and request the final inspections. If compliance is not obtained by the due date penalty of $500.00 shall apply. Sec. 8-5. - Unsa fe Structures. (a)General. (3)Incomplete buildings commenced without a permit or for which the permit has expired, or completed buildings commenced without a permit or for which the permit has expired, prior to completion and no Certificate of Occupancy has been issued, shall be presumed and deemed unsafe and a permit shall be obtained to demolish the structure or bring the building into compliance with the applicable codes as provided herein. Additional specific details concerning the violation together with photographs can be obtained from the Building Department Violation Section in writing upon request. You have the right to appeal this decision of the Building Official to the Unsafe Structures Board in accordance with Chapter 8, section 8-5 of the Miami-Dade County Code. Failure to comply by the due date will result in the Building Official requesting a hearing before the Unsafe Structures Board on the next available calendar. Unless the decision of the Unsafe Structures Board is appealed, the building or structure shall be demolished without further notice. Violation will not be closed until final inspection is obtained in the related permits to close the case. ·- - ------------- -~~-- ---, Code Code Description 1 I BV-9165 THE CITY OF MIAMI BEACH MUNICIPAL CODE 14-61(b) UNSAFE STRUCTURES- FEES (c) PENAL TY IS IMPOSED WHEN NO PERMIT IS OBTAINED ON WORK FOR WHICH A PERMIT IS REQUIRED. THE APPLICANT SHALL BE REQUIRED TO PAY $500.00 PLUS DOUBLE FEES FOR A PERMIT, AS SPECIFIED HEREIN AS THE COST OF THE PERMIT. THE PAYMENT OF A PERMIT FEE SHALL NOT RELIEVE ANY PERSON, FIRM, OR CORPORATION FROM FULLY COMPLYING WITH THE REQUIREMENTS OF THIS CODE, NOR FROM ANY OTHER PENAL TIES PRESCRIBED THEREIN. Revised: 2/14/2023 12:29:24 PM Page 13 of 29 M IAM I BEACH 11:00AM Special Master Case# SMB2021-00970 Department Violation # US2020-03543 AREA Fire Inspection Zone 2 Inspector Comments: Adrian Avalos Description: Violation Type: SM Initial Hearing Property Address: 1341 MERIDIAN AVE MERIDI AN PARK CONDO Status: Owe Money MITIGATION NOTICE OF VIOLA TION ISSUED. 1341 MERIDIAN AVE. Evidence of interior structure deterioration in unit 205. Need to submit engineer's report identifying source of damages thro ugh out building, along with methods of repair. Need to obtain approved permit(s) and ca ll for inspections. Additional specific details concerning the violation together with photographs can be obtained from the Building Department Violation Section in writing upon request. You have the right to appeal this decision of the Building Official to the Unsafe Structures Board in acco rdance with Chapter 8, section 8-5 of the Miami-Dade County Code. Failure to comply by the due date will result in the Building Official requesting a hearing before the Unsafe Structures Board on the next available calendar. Unless the decision of the Unsafe Structures Board is appealed, the building or structure shall be demolished without further notice. Violation will not be closed until final inspection is obtained in the related permit(s) to close the case. Code Code Description ----- ---1 BV-9005 MIAMI-DADE COUNTY MUNICIPAL CODE CHAPTER 8, SECTION 8-5 - UNSAFE STRUCTURES - (a) GENERAL (1) THE UNSAFE STRUCTURES BOARD IS CREATED TO EXERCISE THROUGHOUT THE INCORPORATED AND UNINCORPORATED AREAS OF MIAMI-DADE COUNTY THE POWERS AND DUTIES GRANTED BY THIS SECTION. THE BOARD SHALL HAVE EXCLUSIVE JURISDICTION IN BOTH THE INCORPORATED AND UNINCORPORATED AREAS OF MIAMI-DADE COUNTY WITH RESPECT TO ITS POWERS, DUTIES AND FUNCTIONS. THE BOARD SHALL BE ENTRUSTED WITH HEARING APPEALS OF DECISIONS OF BUILDING OFFICIALS DECLARING STRUCTURES TO BE UNSAFE WHERE THERE IS AN IMMEDIATE DANGER TO THE HEAL TH AND SAFETY OF THE CITIZENS, ALL IN THE MANNER PRESCRIBED IN THIS SECTION. 11:00AM Special Master Case# SMB2021-01287 Department Violation # US2021-03816 AREA Fire Inspection Zone 1 Inspector Comments: Ibrahim Alvarez Description: Violation Type: SM Initial Hearing Property Address: 320 MERIDIAN AVE CHABAD OF SOUTH BEACH INC Status: Open NEW CASE NOTICE OF VIOLATION ISSUED. Process 40YR1901511 not in compliance; therefore, as per the Florida Building Code and Miami- Dade County chapter 8-5 (6), the property is deemed unsafe if a 40Year Recertification report is not completed. You must have the 40Year Recertification. Process(s) completed within thirty calendar days from the posting of this notice. Penalty of $500.00 shall apply Sec. 8-5. - Unsafe Structures (6), Buildings or structures subject to the recertification requirements in Section 8-11(f) of this Code which the owner fails to timely respond to the Notice of Required Inspection or fails to make all required repairs or modifications found to be necessary resulting from the recertification inspection by the deadline specified in the Code or any written extension granted by the Building Official will be demolished. Code Code Description BV-7015 FAILURE TO PROVIDE THE BUILDING DEPARTMENT WITH THE REQUIRED RE-CERTIFICATION OF OLDER BUILDINGS REPORT. Revised: 2/14/2023 12:29:24 PM Page 14 of 29 M IA M I BEACH 11:00AM S p e c ia l M a s te r C a se# SMB2021-0 1288 D e p a rt m e n t Vi ol a tion # U S 2 02 1-03 58 0 AREA F ire In s p ectio n Zone 3 In s p ec to r C o m m e n ts : A d ria n A va lo s D e s c rip tio n : Violation Type: S M Initia l He aring P ro p e rty A dd re ss: 4011 M E R ID IA N A VE T H E C A S T IL L E C O N D O A S S O C . Status: Open N E W C A S E N O T IC E O F V IO LA T IO N IS S U E D . P ro cess 4 0Y R 19 0 15 89 not in co m pliance; therefo re, as per the Florida Building C ode and M iam i- D a de C ou nty ch apter 8-5 (6 ), the property is deem ed unsafe if a 40Y ear R ecertification report is no t co m p le ted . Y ou m ust have the 40 Y ea r R ece rtificatio n. Process(s) com pleted w ithin thirty calendar days from the po sting of this no tice . P ena lty of $500.00 shall apply S e c. 8-5. - U nsafe S tructures (6 ), B u ilding s or structures subje ct to the recertification requirem ents in Section 8-11(f) of this C o de w hich the ow ne r fails to tim ely respond to the N otice of R equired Inspection or fails to m ake all required repairs or m o dificatio ns fo und to be necessary resulting from the recertification in spectio n by the de adline specifie d in the C ode or any w ritten extension granted by the Building O ffi ci a l w ill be dem o lishe d . Code Code Description ' I B V-70 15 FA IL U R E T O P R O V ID E TH E B U IL DI N G D E P A R T M E N T W IT H TH E R E Q U IR ED R E-C E R TIFIC A TIO N O F O LD ER B U IL D IN G S R E P O R T . 11:00AM S p e ci a l M a s te r C a s e# SMB2022-01537 D e p a rt m e n t V io la tio n # B V C 2 10 0 0 73 1 AREA F ire In s p e cti o n Z o n e 3 In s p ecto r A d ria n A va lo s D e s c rip tio n : S M In itial H e aring P ro p e rty A dd ress: N O U M N O U M LL C 16 17 JE FFE R S O N AVE Status: Open C o m m e n ts: N E W C A S E Violation Type: N O T IC E O F V IO LA T IO N . 16 17 JE FF E R S O N A V E # PH 1. N o tice of vio latio n is in reference to the installation of a w asher and dry er in the bathro om , w ithout o btainin g ap pro ved perm its. N e e d to obtain appro ved perm its and ca ll for final inspections. N o tice of vio latio n w ill no t be clo sed until the perm it(s) is put on finaled status. If com pliance is not obtained by th e due da te , do ub le perm it fees and $500 penalty applies in the perm it(s) fees due to w o rk do ne w itho ut perm it(s). S e c. 8-5 . - U nsafe S tructures. (a )G e ne ral. (3 )In co m p lete build ings co m m e nced w ithout a perm it or fo r w hich the perm it has expired, or co m p leted buildin g s co m m e nced w ithout a perm it or fo r w hich the perm it has expired, prior to co m p letio n and no C ert ifica te of O ccupancy has been issued, shall be presum ed and deem ed unsafe and a pe rm it sha ll be obtained to de m olish the structure or bring the building into co m p lia nce w ith the ap plica b le codes as pro vided herein. A d ditio na l spe cific details co ncern ing the violation together w ith photographs ca n be obtained fro m the B uildin g D e part m e nt V io lation Section in w riting upon request. Y o u have the rig ht to app e al this decision of the Building O ffi ci al to the U nsafe Stru ctures Board in acco rdan ce w ith C hapter 8, se ctio n 8-5 of the M iam i-D ade C ounty C ode. Failure to com ply by the due date w ill resu lt in the Bu ild ing O ffi cial requesting a hearing befo re the U nsafe Stru ctures B o a rd on the ne xt availa ble ca le ndar. U nless the deci sion of the U nsafe Structures Board is ap pe aled , the build ing or structure shall be dem olished w ithout further notice. V io latio n w ill no t be clo se d un til final inspection is obtained in the related perm its to cl ose the ca se. Code Code Description B V -9 16 5 TH E C ITY O F MIAMI B E A C H M U N IC IP A L C O D E 14 -6 1(b) U N S A FE STR U C TU R ES - FE ES (c) PEN A LTY IS IM PO SED W H E N N O P E R M IT IS O B TA IN E D O N W O R K FO R W H IC H A PE R M IT IS R EQ U IR ED . TH E A PPLIC A N T SH A LL BE R E Q U IR E D TO P A Y $5 00 .0 0 P L U S D O U B L E FE E S FO R A PE R M IT , A S SP EC IFIE D H E R E IN AS TH E C O ST O F TH E P E R M IT . TH E P A Y M E N T O F A P E R M IT FE E S H A LL N O T R E LI E V E A N Y PE R S O N , FIR M , O R C O R PO RA TIO N FR O M F U L LY C O M P L Y IN G W IT H TH E R E Q U IR E M E N T S O F TH IS C O D E , NO R FR O M AN Y O T H E R PEN A L TIES PR ESC R IBED T H E R E IN . R ev is ed : 2/14 /2 02 3 12 :2 9 :2 4 PM Page 15 of 29 M IA M I BEACH 11:00AM Special Master Case# SMB2022-01538 Department Violation # BV15000652 AREA Fire Inspection Description: Zone 3 Inspector Adrian Avalos Comments: Violation Type: SM Initial Hearing Property Address: 3801 INDIAN CREEK DR TM40 LLC Status: Open NEW CASE NOTICE OF VIOLATION ISSUED. Unit #313Work done without approved permit. Kitchen and bathroom. Need to submit the required documents to obtain approved permit and inspections, Double fees apply.As per Miami-Dade County Chapter 8-5(3) work done without approved permit is considered unsafe. Need to submit the required documents to obtain approved permit within 30 days. If permit is not obtained by the due date, penalty of $500.00 fine will be imposed. (Building Violation) Code Code Description BV-9165 THE CITY OF MIAMI BEACH MUNICIPAL CODE 14-61(b) UNSAFE STRUCTURES- FEES (c) PENALTY IS IMPOSED WHEN NO PERMIT IS OBTAINED ON WORK FOR WHICH A PERMIT IS REQUIRED. THE APPLICANT SHALL BE REQUIRED TO PAY $500.00 PLUS DOUBLE FEES FOR A PERMIT, AS SPECIFIED HEREIN AS THE COST OF THE PERMIT. THE PAYMENT OF A PERMIT FEE SHALL NOT RELIEVE ANY PERSON, FIRM, OR CORPORATION FROM FULLY COMPLYING WITH THE REQUIREMENTS OF THIS CODE, NOR FROM ANY OTHER PENAL TIES PRESCRIBED THEREIN. 11:00AM Special Master Case# SMB2022-01539 Department Violation # US2020-03537 AREA Fire Inspe ction Description: Zon e 1 Inspector Comments: Adrian Avalos Violation Type: SM Initial Hearing Property Address: 645 LENOX AVE 645 LENOX AVE LLC Status: Open NEW CASE NOTICE OF VIOLATION ISSUED. Floor structure in unit #5 collapsed. Need to submit report signed and sealed by an engineer to evaluate the structure conditions of the entire building together with methods of repairs. Need to obtain approved permit and inspections. Affected unit cannot be occupied until all repairs are completed and inspected. Additional specific details concerning the violation together with photographs can be obtained from the Building Department Violation Section in writing upon request. You have the right to appeal this decision of the Building Official to the Unsafe Structures Board in accordance with Chapter 8, section 8-5 of the Miami-Dade County Code. Failure to comply by the due date will result in the Building Official requesting a hearing before the Unsafe Structures Board on the next available calendar. Unless the decision of the Unsafe Structures Board is appealed, the building or structure shall be demolished without further notice. Violation will not be closed until final inspection is obtained in the related permits to close the case. ------- - --------- - - ------------------ --- -------- Code Code Description I BV-9005 MIAMI-DADE COUNTY MUNICIPAL CODE CHAPTER 8, SECTION 8-5 - UNSAFE STRUCTURES - (a) GENERAL (1) THE UNSAFE STRUCTURES BOARD IS CREATED TO EXERCISE THROUGHOUT THE INCORPORATED AND UNINCORPORATED AREAS OF MIAMI-DADE COUNTY THE POWERS AND DUTIES GRANTED BY THIS SECTION. THE BOARD SHALL HAVE EXCLUSIVE JURISDICTION IN BOTH THE INCORPORATED AND UNINCORPORATED AREAS OF MIAMI-DADE COUNTY WITH RESPECT TO ITS POWERS, DUTIES AND FUNCTIONS. THE BOARD SHALL BE ENTRUSTED WITH HEARING APPEALS OF DECISIONS OF BUILDING OFFICIALS DECLARING STRUCTURES TO BE UNSAFE WHERE THERE IS AN IMMEDIATE DANGER TO THE HEAL TH AND SAFETY OF THE CITIZENS, ALL IN THE MANNER PRESCRIBED IN THIS SECTION. Revised: 2/14/2023 12:29:24 PM Page 16 of 29 M IA M I BEACH 11:00AM Special Master Case# SMB2022-01540 Department Violation# BVB21001322 AREA Fire Inspection Zone 1 Inspector Comments: Ibrahim Alvarez Description: Violation Type: SM Initial Hearing Property Address: 124 COLLINS AVE KAINE 136 LLC r/a Lawrence F Kaine Status: Open NEW CASE NOTICE OF VIOLATION ISSUED. New Deck and Wood Wall installed without permit(s). Need to submit the required documents to obtain approved permit(s) and inspections. Double permit fees and $500 penalty applies in the permit(s) fees due for the work done without permit(s). If compliance is not obtained by the due date an additional penalty of $500.00 shall apply. Sec. 8-5. - Unsafe Structures. (a)General. (3)Incomplete buildings commenced without a permit or for which the permit has expired, or completed buildings commenced without a permit or for which the permit has expired, prior to completion and no Certificate of Occupancy has been issued, shall be presumed and deemed unsafe and a permit shall be obtained to demolish the structure or bring the building into compliance with the applicable codes as provided herein. Additional specific details concerning the violation together with photographs can be obtained from the Building Department Violation Section in writing upon request. You have the right to appeal this decision of the Building Official to the Unsafe Structures Board in accordance with Chapter 8, section 8-5 of the Miami-Dade County Code. Failure to comply by the due date will result in the Building Official requesting a hearing before the Unsafe Structures Board on the next available calendar. Unless the decision of the Unsafe Structures Board is appealed, the building or structure shall be demolished without further notice. Violation will not be closed until final inspection is obtained in the related permits to close the case. -------------------------- ---------------- Code Code Description 1 BV-9165 THE CITY OF MIAMI BEACH MUNICIPAL CODE 14-61(b) UNSAFE STRUCTURES- FEES (c) PENALTY IS IMPOSED WHEN NO PERMIT IS OBTAINED ON WORK FOR WHICH A PERMIT IS REQUIRED. THE APPLICANT SHALL BE REQUIRED TO PAY $500.00 PLUS DOUBLE FEES FOR A PERMIT, AS SPECIFIED HEREIN AS THE COST OF THE PERMIT. THE PAYMENT OF A PERMIT FEE SHALL NOT RELIEVE ANY PERSON, FIRM, OR CORPORATION FROM FULLY COMPLYING WITH THE REQUIREMENTS OF THIS CODE, NOR FROM ANY OTHER PENAL TIES PRESCRIBED THEREIN. Revised: 2/14/2023 12:29:24 PM Page 17 of 29 M IA M I BEA CH 11:00AM Speci al M aster C ase# SMB2022-01548 D epartm ent V iolation# US2021-03610 AREA Fire Inspection Zone 3 Inspector A drian Avalos D escription: SM Initial Hearing Property Address: PHILIP GIORDANO 100 ED I LI DO DR Status: Open C om m ents: NEW CA SE Violation Type: NO TICE O F VIO LA TIO N. 100 EDI LI D O DR . Perm it PO -R 1800227 is in SUSPEND ED status. Need to hire a contractor able to obtain/renew an approved perm it and final inspections. Sec. 8-5. - Unsafe Stru ctures. (a)General. (3)Incom plete buildings com m enced w ithout a perm it or fo r which the perm it has expired, or co m pleted buildings com m enced without a perm it or fo r w hich the perm it has expired, prior to com pletion and no Certificate of Occupancy has been issued, shall be presum ed and deem ed unsafe and a perm it shall be obtained to dem olish the structure or bring the building into com pliance w ith the applica ble codes as provided herein. Additional specific details concern ing the violation together w ith photographs can be obtained from the Building Departm ent Violation Section in w riting upon request. You have the right to appeal this decision of the Building Offi cial to the Unsafe Structures Board in acco rdance w ith Chapter 8, section 8-5 of the M iam i-D ade County Code. Failure to com ply by the due date will result in the Building Official requesting a hearing befo re the Unsafe Structures Board on the next available ca lendar. Unless the decision of the Unsafe Structure s Board is appealed, the building or structure shall be dem olished w ithout further notice. Violation w ill not be closed until final inspection is obtained in the related perm its to close the ca se. As per Florida Building Code and M iam i-Dade County chapter 8-5 (6) Physical criteria (2) building is unsafe, the building Offi cial has the authority to deem and declare the pro perty UNSAFE. If co m pliance is not obtained by the due date; the case w ill be sent to M iam i-D ade County Unsafe Structure Board and penalty of $500.00 will be im posed. Code Code Description [ BV-1040 DO NO T CO NTIN U E W ITH ANY FU RTHER W O RK UNTIL THE CHANG E OF CO NTRACTO R , CHANG E OF ARCHITECT OR CHA NG E OF ENG IN EER PAPERW O R K HAS BEEN SUBM ITT ED AND APPRO VED BY THE BU ILDING DEPA RTM ENT. Revised: 2/14/2023 12:29:24 PM Page 18 of 29 M IA M I B E A C H 11:00AM Special Master Case# SMB2022-01549 Depart m ent V iolation # BV P20000054 AREA Fire Inspection Zone 3 Inspector A drian A valos Description: SM Initial Hearing Property Address: SOBE AL TON LLC Status: Open 1750 AL TON RD C om m ents: NEW CA SE Violation Type: STO P W O R K O R DE R/NO TIC E O F VIO LA TIO N ISSU ED Interior build out w ithout approved perm its, all trades. Need to obtain approved permit(s) and inspections. Need to subm it the required docum ents to obtain approved perm it(s) and inspections. Double perm it fees and $500 penalty applies in the perm it(s) fees due to w ork done w ithout perm it (s). If com pliance is not obtained by 03/09/2020 an additional penalty of $500.00 shall apply. Sec. 8-5. - Unsafe Structures. (a)G eneral. (3)Incom plete buildings com m enced w ithout a perm it or fo r which the perm it has expired, or com pleted buildings com m enced without a perm it or fo r w hich the perm it has expired, prior to com pletion and no Certificate of O ccupancy has been issued, shall be presum ed and deem ed unsafe and a perm it shall be obtained to dem olish the structure or bring the building into co m pliance w ith the applicable codes as pro vided herein. Additional specific details concern ing the violation together with photographs ca n be obtained from the Building Departm ent Violation Section in writing upon request. You have the right to appeal this decision of the Building Offi cial to the Unsafe Structures Board in accordance with Ch apter 8, section 8-5 of the M iam i-D ade County Code. Failure to com ply by the due date w ill result in the Building O ffi cial requesting a hearing befo re the Unsafe Structures Board on the next available calendar. Unless the deci sion of the Unsafe Structures Board is appealed, the building or structure shall be demolished without further notice. Violation will not be closed until final inspection is obtained in the related permits to close the case. Code Code Description ! BV-9165 TH E CITY O F MIAMI BEACH MUNICIPAL CODE 14-61(b) UNSAFE STRUCTURES- FEES (c) PENAL TY IS IMPOSED WHEN NO PERMIT IS OBTAINED ON WORK FOR WHICH A PERMIT IS REQUIRED. THE APPLICANT SHALL BE REQUIRED TO PAY $500.00 PLUS DOUBLE FEES FOR A PERMIT, AS SPECIFIED HEREIN AS THE COST OF THE PERMIT. THE PAYMENT OF A PERMIT FEE SHALL NOT RELIEVE ANY PERSON, FIRM, OR CORPORA TION FROM FU LLY CO M PLY ING W ITH TH E REQ UIR EM ENTS O F TH IS CO DE , NO R FROM ANY OTHER PENAL TIES PRESCRIBED TH ER EIN . Revi sed: 2/14/2023 12:29:24 PM Page 19 of 29 M IA M I B E A C H 1:30PM Special Master Case# SMB2021-01365 Department Violation # BVC20000530 AREA Fire Inspection Zone 1 Inspector Adrian Avalos Description: SM Initial Hearing Property Address: CARLOS DOSAL 635 EUCLID AVE Status: Open Comments: R/S---PIS Violation Type: NOTICE OF VIOLATION ISSUED. Unit 110 Evidence of work commenced without approved/issued permit(s ). Kitchen was remodeled, Air conditioner unit was replaced and relocated with new stand. Need to obtain approved permit(s) and lnspection(s) for all items listed above. If permit(s) is/are obtained within 07 days no penalty shall apply, after 07 days double permit fees and $500 penalty applies in the permit(s) fees due to work done without permit(s). If compliance is not obtained by 04/13/2020 an additional penalty of $500.00 shall apply. Sec. 8-5. - Unsafe Structures. (a)General. (3)Incomplete buildings commenced without a permit or for which the permit has expired, or completed buildings commenced without a permit or for which the permit has expired, prior to completion and no Certificate of Occupancy has been issued, shall be presumed and deemed unsafe and a permit shall be obtained to demolish the structure or bring the building into compliance with the applicable codes as provided herein. Additional specific details concerning the violation together with photographs can be obtained from the Building Department Violation Section in writing upon request. You have the right to appeal this decision of the Building Official to the Unsafe Structures Board in accordance with Chapter 8, section 8-5 of the Miami-Dade County Code. Failure to comply by the due date will result in the Building Official requesting a hearing before the Unsafe Structures Board on the next available calendar. Unless the decision of the Unsafe Structures Board is appealed, the building or structure shall be demolished without further notice. Violation will not be closed until final inspection is obtained in the related permits to close the case. ------------------------------- --~---------------- C o d e /C o d e D es c ripti o n ] BV-9165 THE CITY OF MIAMI BEACH MUNICIPAL CODE 14-61(b) UNSAFE STRUCTURES- FEES (c) PENALTY IS IMPOSED WHEN NO PERMIT IS OBTAINED ON WORK FOR WHICH A PERMIT IS REQUIRED. THE APPLICANT SHALL BE REQUIRED TO PAY $500.00 PLUS DOUBLE FEES FOR A PERMIT, AS SPECIFIED HEREIN AS THE COST OF THE PERMIT. THE PAYMENT OF A PERMIT FEE SHALL NOT RELIEVE ANY PERSON, FIRM, OR CORPORATION FROM FULLY COMPLYING WITH THE REQUIREMENTS OF THIS CODE, NOR FROM ANY OTHER PENAL TIES PRESCRIBED THEREIN. 1:30PM Special Master Case# SM B2022-01450 Department Violation# US2021-03704 AREA F in e In s p e ctio n Description: Z o n e 4 Inspector Comments: Ibrahim Alvarez Violation Type: SM Initial Hearing Property Address: 5313 COLLINS AVE THE AMETHYST CONDOMINIUM ASSOCIATION INC. Status: Open NEW CASE NOTICE OF VIOLATION ISSUED. 5313 COLLINS AVE. Notice of violation has been issued due to evidence of spalling concrete. Need to submit a report signed and sealed by engineer to evaluate the structure and determine if the building may remain occupied or any occupancy limitations in order to remain occupied, as well as methods of repairs. Need to obtain approved permit(s) and call for inspections. As per Florida Building Code and Miami-Dade County chapter 8-5 (6) Physical criteria (2) building is unsafe, the building Official has the authority to deem and declare the property UNSAFE. Additional specific details concerning the violation together with photographs can be obtained from the Building Department Violation Section in writing upon request. You have the right to appeal this decision of the Building Official to the Unsafe Structures Board in accordance with Chapter 8, section 8-5 of the Miami-Dade County Code. Failure to comply by the due date will result in the Building Official requesting a hearing before the Unsafe Structures Board on the next available calendar. Unless the decision of the Unsafe Structures Board is appealed, the building or structure shall be demolished without further notice. Violation will not be closed until final inspection is obtained in the related permit(s) to close the case. C o d e C o d e D e s c rip ti o n I BV-9050 MIAMI-DADE COUNTY, CHAPTER 8, SECTION 8-5- UNSAFE STRUCTURES (b) PHYSICAL CRITERIA. (2) A BUILDING, OR PART THEREOF, SHALL BE PRESUMED TO BE UNSAFE IF: (ii) THERE IS A DETERIORATION OF THE STRUCTURE OR STRUCTURAL PARTS. Revised: 2/14/2023 12:29:24 PM Page 20 of 29 M IA M I B E A C H 1:30PM Special Master Case# SMB2022-01459 Department Violation # US2021-03862 AREA Fire Inspection Zone2 Inspector Comments: Ibrahim A lvarez Description: Violation Type: SM Initial Hearing Property Address: VILA MARA CONDO Status: Open 1027 EUCL ID AVE NEW CASE NO TIC E OF VIO LA TIO N ISSUED . 1027 EUC LI D AVE. Pro cess 40YR200164 6 is not in com pliance, therefo re, as per the Florida Building Code and M iam i-Dade County ch apt er 8-5 (6) the property is deem ed unsafe if a 40 Year Recertification report is not com pleted. A recent inspection report m ust be subm itted within 14 days. this report is to be signed and sealed by a Florida Li censed design professional and m ust detail the conditions of the structural and electrica l system s fo r the referenced address. If the professional inspection report finds deficiencies that require correction the Florida Li censed design pro fessional M U ST provide a cover letter indica ting if the building ca n rem ain occupied. Failure to pro vide this report w ill result in escalating this violation into Speci al M aster Hearing, Unsafe Stru cture Board, and including vacating the structure. Sec. 8-5. - Uns afe Structures (6) Buildings or stru ctures subject to the recertification requirem ents in Section 8-11(f) of this Code which the owner fails to tim ely respond to the Notice of Required Inspection or fails to m ake all required repairs or m odifica tions fo und to be necessary resulting from the recertification inspection by the deadline specified in the Code or any w ritten ext ension granted by the Building Offi ci al will be dem olished. Code Code Description [ ' BV -7015 FAILUR E TO PRO VID E THE BUILD ING DEPARTM ENT W ITH TH E REQU IRED RE-CERTIFICATIO N OF O LDER BU ILD IN G S REPO RT. 1:30PM Special Master Case# SMB2022-01460 Department Viol ation # US2021-03907 AREA Fire Inspection Description: Zone 1 Inspector Comments: Ibrahim A lvarez Violation Type: SM Initial Hearing Property Address: 10 00 7 ST 7TH STREET LIVING LLC Status: Open NEW CASE NO TICE OF VIO LA TIO N ISSU ED . 1000 7th St Pro ce ss 40YR2101995 is not in com pliance; therefo re, as per the Florida Building Code and M iam i-Dade County ch apter 8-5 (6), the property is deem ed unsafe if a 40Year Recertification report is not com pleted. You m ust subm it the 40Year Recertifica tion reports w ithin thirty ca lendar days from delivery of this violation. Penalty of $500.00 shall apply, and continued enfo rcem ent. If the reports are provided with deficienci es, perm it(s) fo r repair(s) m ust be applied within thirty ca lendar days and obtained w ithin sixty ca lendar days from perm it pro cess application date. Failure to com ply will result in additional penalty of $500.00, and continued enfo rcem ent from the Special M agistrate's offi ce, leading to the Unsafe stru cture's board. Sec. 8-5. - Uns afe Structures (6), Buildings or structures subject to the recertification requirem ents in Section 8-11(f) of this Code w hich the owner fails to tim ely respond to the Notice of Required Inspection or fails to m ake all required repairs or m odifica tions fo und to be necessary resulting from the recertification inspection by the deadline specified in the Code or any w ritten extension gra nted by the Building Offi cial w ill be dem olished. Code Code Description [ BV-7015 FAILUR E TO PR O VID E THE BU ILDI NG DEPARTM ENT W ITH THE REQ U IRED RE-CERTIFIC ATIO N O F O LDER BU ILDI NG S REPO RT. Revi sed: 2/14/2023 12:29:24 PM Page 21 of 29 M IA M I B E A C H 1:30PM Special Master Case# SMB2022--01461 Department Violation # US2021-03909 AREA Fire Inspection Zone 3 Description: SM Initial Hearing Property Address: 1606 WEST AVE URBAN BEACH XXII LLC C/O SENTINEL REAL ESTATE CORP Status: Open In s p e cto r Comments: Ib rah im Alvarez Violation Type: N E W C A S E N O T IC E O F V IO LA T IO N IS S U E D . 16 0 6 W e st A ve P roce ss 40 Y R 2 10 20 06 is not in com p lia nce ; the refo re , as per the Flo rida B uild ing C o de and M ia m i-D ad e C o unty ch a pter 8-5 (6 ), the pro p ert y is de e m e d unsafe if a 40 Y ea r R e cert ifi catio n repo rt is no t co m p leted . Y o u m u st su b m it the 40 Y ear R ecert ificatio n rep o rt s w ithin thirt y ca lenda r days fr om de livery of this vio la tio n . P en a lty of $5 00 .0 0 shall app ly, and co nti n ue d enforcem e nt. If the re po rt s are pro vide d w ith defi cie ncies , pe rm it(s) fo r repair(s) m ust be app lie d w ithin thirt y cale nd a r da ys and obtaine d w ithin sixty ca le nd a r da ys fr om pe rm it pro cess app licatio n da te. Fa ilure to co m ply w ill result in additio nal pe na lty of $5 0 0 .0 0 , and continue d enfo rcem e nt fro m the S p ecia l M a g istrate's offi ce , le ad ing to the U nsafe structure's bo ard. S e c. 8-5 . - U nsa fe St ru ct ures (6 ), B u ild in g s or structure s subject to the re cert ifi catio n req uirem e nts in S e ct ion 8-11(f) of this C o de w hich the ow ne r fails to tim e ly respo nd to the N o tice of R equ ired Insp ectio n or fails to m a ke all req u ired rep airs or m o difi cations fo und to be ne cessary resulti ng fr om the re cert ifi catio n inspe ctio n by the de adline specifi e d in the C o de or any w ritten extensio n granted by the B uilding O ffi cia l will be de m o lishe d . C o e c o d e D e scr ipt i on ] I B V -70 15 FA IL U R E T O P R O V ID E T H E B U IL D IN G D E P A R T M E N T W IT H T H E R E Q U IR E D R E -C E R T IF IC A T IO N O F O LD E R B U IL D IN G S R E P O R T . 1:30PM Special Master Case# SMB2022--01465 Departm ent Violation # U S 2 02 1-0 3 9 18 AREA Fire In spe ctio n Z o n e 6 In s p ecto r Comments: Ib rah im A lv a rez Description: Violation Type: S M In itia l H e a ring Property Address: 590 0 C O LLI N S A V E THE GRA NDVIEW CONDO ASSOC Status: Open N E W C A S E N O T IC E O F V IO LA T IO N IS S U E D . E vide nce of W ater intrusio n at several U n its. N e e d to subm it eng inee r's rep ort ide ntify ing so urce of w ater in trusio n and m e tho ds of repairs . N e e d to obta in ap p ro ved perm it(s) if req uired . A dd itio na l spe cifi c de tails co ncern ing the vio latio n tog e the r w ith pho tog raphs ca n be obta ine d fr o m the B uild ing D e pa rt m ent V io latio n S e ctio n in w riting upo n reque st. Y o u ha ve the rig ht to app eal this de cisio n of the B uild ing O ffi cial to the U nsafe S tructures B o ard in acco rda nce w ith C ha pter 8, sect ion 8-5 of the M ia m i-D a de C o unty C od e . Failu re to co m ply by the due da te w ill re sult in the B uilding O ffi cia l req ue sting a hea ring befo re the U nsa fe S tructures B oa rd on the ne xt availab le ca le ndar. U n le ss the de ci sio n of the U nsafe S tructures B o ard is ap p ea le d , the bu ild ing or structure sha ll be de m o lishe d w itho ut furt he r no tice . V io la tio n w ill no t be cl o se d until final inspe ctio n is obta ined in the rela ted pe rm it(s) to clo se the ca se . --- -- ---- -----------------------~------------- - - C o d e C o d e D es crip tio n ' B V -10 30 34 0 1.6 M A IN T E N A N C E : A LL B U IL D IN G S , S T R U C T U R E S , E LE C T R IC A L, G A S , M E C H A N IC A L A N D P L U M B IN G S Y S T E M S , B O T H E X IS T IN G A N D N E W , A N D A LL P A R T S T H E R E O F , S H A L L B E M A IN T A IN E D IN A S A F E A N D S A N ITA R Y C O N D ITI O N . A LL D E V IC E S O R S A F E G U A R D S W H IC H A R E R E Q U IR E D B Y T H E T E CHNICAL CODES WHEN C O N S T R U C T E D , A LT E R E D O R R E P A IR E D , S H A LL B E M A IN T A IN E D IN G O O D W O R K IN G O R D E R . T H E O W N E R , O R H IS D E S IG N A T E D A G E N T , S H A L L B E R E S P O N S IB L E FO R T H E M A IN T E N A N C E O F B U ILD IN G S , S T R U C T U R E S , E L E C T R IC A L, G A S , M E C H A N IC A L A N D P L U M B IN G S Y S T E M S . R evis e d : 2/14 /20 2 3 12 :2 9:2 4 PM P a g e 22 of 29 M IA M I BEACH 1:30PM Special Master Case# SMB2022-01466 Department Violation# US2021-03879 AREA Fire Inspection Zone3 Inspector Comments: Ibrahim A lvarez Description: Violation Type: SM Initial Hearing Property Address: 3030 COLLINS AVE THE MADISON CONDO Status: Open NEW CA SE NO TIC E O F VIO LA TIO N ISSUED. 3030 Collins Ave Process 40YR210 1924 is not in com pliance; therefo re, as per the Florida Building Code and M iam i-Dade County chapter 8-5 (6), the pro perty is deem ed unsafe if a 40Y ear Recertification report is not com pleted. You m ust submit the 40Year Recertification reports within thirty calendar days from delivery of this violation. Penalty of $500.00 shall apply, and continued enforcement. If the reports are provided with deficiencies, permit(s) for repair(s) must be applied within thirty ca lendar days and obtained w ithin sixty calendar days from perm it process application date. Failure to comply will result in additional penalty of $500.00, and continued enforcement from the Special Magistrate's office, leading to the Unsafe structure's board. Sec. 8-5. - Unsafe Structures (6), Buildings or structures subject to the recertification requirements in Section 8-11(f) of this Code which the ow ner fails to timely respond to the Notice of Required Inspection or fails to make all required repairs or modifications found to be necessary resulting from the recertification inspection by the deadline speci fied in the Code or any written extension granted by the Building O ffi ci al will be demolished. Code Code Description ] BV-7015 FAILURE TO PROVIDE THE BUILDING DEPARTMENT WITH THE REQUIRED RE-CERTIFICATION OF OLDER BUILDINGS REPORT. Special Master Case# SMB2022-01513 Property Address: ect ·, 1:30PM Department Violation # US2020-03402 AREA de,en- - re Fire Inspection Description: SM Initial Hearing Status: Open r" .eel- Zone 5 0o- Inspector Comments: NEW CASE Adrian Avalos Violation Type: NOTICE OF VIOLATION Process 40YR18010 not in compliance; therefore, as per the Florida Building Code and Miami- Dade County ch r 8-5 (6), the property is deemed unsafe if a 40Year Recertification report is not complete You must ve the 40Year Recertification. Process(s) needs to be completed within thirty calen days from the posting of this notice. Penalty of $500.00 has been applied. ec. 8-5. - Uns afe Structures (6), Buildin gs or structures subject to the recertification requirements in Section 8-11(f) of this Code which the owner fails to timely respond to the Notice of Required Inspection or fails to make all required repairs or modifications found to be necessary resulting from the recertification inspection by the deadline specified in the Code or any written extension granted by the Building Official will be demolished. Code Code Description ' BV-7015 FA ILUR E TO PRO V IDE THE BU ILD ING DEPA RTM EN T W ITH THE REQ U IR ED RE-C E RTIFIC A TIO N O F OLDER BU ILD ING S REPO RT. Revised: 2/14/2023 12:29:25 PM Page 23 of 29 M IA M I B E A C H 1:30PM Special M aster Case# SMB2022-01533 Departm ent Viol ation # US2021-03668 AREA Fine Inspection Description: Zone4 Inspector C om m ents: Ibrahim Alvarez Violation Type: SM Initial Hearing Property Address: 6969 CO LLI NS AVE PO R T RO YALE CO N D O Status: Open NEW CASE NO TIC E OF VIO LA TIO N ISSUED. 6969 COLLI NS AVE. Notice of violation has been issued due to evidence of structure deterioration, to include spalling concrete. Need to subm it a report signed and sealed by engineer to evaluate the structure and determ ine if it the building is safe fo r occupancy, together with methods of repairs within 48 hours. Need to obtain approved perm it(s) and call fo r inspections. As per Florida Building Code and M iam i-Dade County ch apter 8-5 (6) Physical criteria (2) buildi ng is unsafe, the building Offi cial has the authority to deem and declare the pro perty UNSAFE. Additional specific details concern ing the violation together with photographs can be obtained from the Building Departm ent Violation Section in writing upon request. You have the right to appeal this decision of the Building Offi cial to the Unsafe Structures Board in acc ordance with Cha pt er 8, section 8-5 of the M iam i-Dade County Code. Failure to com ply by the due date will result in the Building Offi cial requesting a hearing befo re the Unsafe Structures Board on the next available ca lendar. Unless the decision of the Unsafe Stru ctures Board is appealed, the building or structure shall be dem olished without further notice. Violation will not be closed until final inspection is obtained in the related permit(s) to close the case. Code \Code Description ] I BV-9005 M IAM I-DADE CO U NTY M UN IC IPAL CO DE CHAPTER 8, SECTI ON 8-5 - UNSAFE STRUCTURES - (a) GENERA L (1) TH E UNSAFE STR UC TU R ES BO ARD IS CREATED TO EX ERCISE THRO UGHO UT THE INCO RPO RATED AND UNINCO R PO RA TED AREAS OF M IAM I-DADE CO UNTY THE POW ERS AND DUTIES GRA NTED BY THIS SECTION. TH E BO ARD SHALL HAVE EXCLUSIVE JURISDI CTIO N IN BOTH TH E INCO RPORA TED AND UNINCO RPO RATED AREAS OF M IAM I-DADE CO U NTY W IT H RESPECT TO IT S POW ERS, DUTIES AND FUNCTIO NS. THE BO ARD SHALL BE ENTRUSTED W ITH HEARING APPEALS OF DECISIONS OF BUILDING OFFICIALS DECLA RING STRUCTU RES TO BE UNSAFE W H ER E TH ER E IS AN IM M EDIATE DANG ER TO THE HEALTH AND SAFETY OF THE CITIZENS, ALL IN THE M ANN ER PRESC R IBED IN TH IS SECTIO N. 1:30PM Special M aster C ase# SMB2022-01536 D epart m ent V iolation# US2021-0 3805 AREA Fire Inspection D escription: Zone 5 Inspector C om m ents: Ibrahim Alvarez Violation Type: SM Initial Hearing Pro perty Address: 7751 HAWTH O RN E AVE LI O N S DEN G LO BAL DEVELO PM ENT LLC Status: Open NEW CASE NO TICE OF VIO LA TI O N ISSUED. Process 40YR1901354 not in com pliance; therefo re, as per the Flor ida Building Code and Miami- Dade County ch apter 8-5 (6), th e pro perty is deem ed unsafe if a 40Year Recertification report is not com pleted. You m ust have the 40Year Recertification. Process(s) com pleted within thirty calendar days from the posting of th is notice. Penalty of $500.00 shall apply Sec. 8-5. - Unsafe Structures (6), Building s or structures subject to the recertifica tion requirem ents in Section 8-11(f) of this Code w hich the owner fails to tim ely respond to the Notice of Required Inspection or fails to make all required repairs or m odifica tions fo und to be necessary resulting from the recertification inspection by the deadline specified in the Code or any written extension granted by the Building Offici al will be dem olished. Code [code Description I BV-7015 FAILU R E TO PR O VID E THE BUILDING DEPARTM ENT W ITH THE REQUIRED RE-CERTIFICATIO N OF OLDER BU ILD ING S REPO RT. Revised: 2/14/2023 12:29:25 PM Page 24 of 29 M IA M I B E A C H 1:30PM Special Master Case# SMB2022-01543 Department Violation # US2021-03920 AREA Fine Inspection Description: Zone 4 Inspector James Bartell Comments: Violation Type: SM Initial Hearing Pro perty Address: 5313 COLLINS AVE THE AMETHYST CONDO Status: Open NEW CASE NOTICE OF VIOLA TION ISSUED. Evidence of Water intrusion. Need to submit engineer's report identifying source of water intrusion and methods of repairs. Need to obtain approved permit(s) and final inspection(s). Additional specific details concerning the violation together with photographs ca n be obtained from the Building Department Violation Section in writing upon request. You have the right to appeal this decision of the Building Official to the Unsafe Structures Board in accordance with Chapter 8, section 8-5 of the Miami-Dade County Cod e. Failure to comply by the due date will result in the Building Official requesting a hearing before the Unsafe Structures Board on the next available calendar. Unless the decision of the Unsafe Structures Board is appealed, the building or structure shall be demolished without further notice. Violation will not be closed until final inspection is obtained in the related perm it(s) to close the case. -- -- ----------- - Code Description BV-1030 3401.6 MAINTENANCE: ALL BUILDINGS, STRUCTURES, ELECTRICAL, GAS, MECHANICAL AND PLUMBING SYSTEMS, BOTH EXISTING AND NEW, AND ALL PARTS THEREOF, SHALL BE MAINTAINED IN A SAFE AND SANITARY CONDITION. ALL DEVICES OR SAFEGUARDS WHICH ARE REQUIRED BY THE TECHNICAL CODES WHEN CONSTRUCTED, ALTERED OR REPAIRED, SHALL BE MAINTAINED IN GOOD WORKING ORDER. TH E OW NER, OR HIS DESIGNATED AGENT, SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF BUILDINGS, STRUCTURES, ELECTRICAL, GAS, MECHANICAL AND PLUMBING SYSTEMS. 2:30PM Special Master Case# SMB2019-00618 Department Violation # BVM 18000001 AREA Fire Inspe ction Zone2 Inspector Adrian Avalos Description: SM Initial Hearing Pro perty Address: LINA MCCONNELL 900 EUCLID AVE Status: Fine Imposed by Special Magistrate Comments: 3RD REQUEST FOR EXTENSION Violation Type: NOTICE OF VIOLA TION ISSUED. Unit #16 Evidence of work done without approved permit. A/C installed at balco ny. Need to obtain approved perm it and inspections. If compliance is not obtained by the due date penalty of $500.00 shall apply. Sec. 8-5. - Unsafe Structures. {a)General. {3)Incomplete buildings commenced without a perm it or for which the permit has expired, or completed buildings commenced without a permit or for which the permit has expired, prior to completion and no Certifica te of Occupancy has been issued, shall be presumed and deemed unsafe and a permit shall be obtained to demolish the structure or bring the building into compliance with the applicable codes as provided herein. Additional specific details concerning the violation together with photog raphs can be obtained from the Building Department Violation Section in writing upon request. You have the right to appeal this decision of the Building Official to the Unsafe Structures Board in accordance with Chapter 8, section 8-5 of the Miami-Dade County Code. Failure to comply by the due date will result in the Building Official requesting a hearing before the Unsafe Structures Board on the next available calendar. Unless the decision of the Unsafe Structures Board is appealed, the building or structure shall be demolished without further notice. Violation will not be closed until final inspection is obtained in the related perm its to close the case. Code Code Description j I BV-9165 THE CITY OF MIAMI BEA CH MUNICIPAL COD E 14-61(b) UNSAFE STRUCTURES- FEES (c) PENALTY IS IMPOSED WHEN NO PERMIT IS OBTAINED ON WORK FOR WHICH A PERMIT IS REQUIRED. TH E APPLICANT SHALL BE REQUIRED TO PAY $500.00 PLUS DOUBLE FEES FOR A PERMIT, AS SPECIFIED HEREIN AS THE COST OF THE PERMIT. THE PAYMENT OF A PERMIT FEE SHALL NOT RELIEVE ANY PERSON, FIRM, OR CORPORA TION FROM FULLY COMPLYING WITH THE REQUIREMENTS OF THIS CODE, NOR FROM ANY OTHER PENAL TIES PRESCRIBED THEREIN. Revised: 2/14/2023 12:29:25 PM Page 25 of 29 M IA M I B E A C H 2:30PM Special Master Case# SMB2019-00624 Department Violation# BVC18000251 AREA South Beach, Zone 3 Inspector Adrian Avalos Description: SM Initial Hearing Property Address: 1234 EUCLID AVE EAST BREEZE CONDO Status: Open Comments: CONTINUANCE Violation Type: Evidence of work done without approved permit. Installation of new doors, security bars, new water lines and valves. Also, installation of laundry area, new plumbing, electrical connections and new light fixtures. Need to submit the required documents to obtain approved permit and inspections. Double permit fees apply. If compliance is not obtained by the due date penalty of $500.00 shall apply. Sec. 8-5. - Unsafe Structures. (a)General. (3)Incomplete buildings commenced without a permit or for which the permit has expired, or completed buildings commenced without a permit or for which the permit has expired, prior to completion and no Certificate of Occupancy has been issued, shall be presumed and deemed unsafe and a permit shall be obtained to demolish the structure or bring the building into compliance with the applicable codes as provided herein. Additional specific details concerning the violation together with photographs can be obtained from the Building Department Violation Section in writing upon request. You have the right to appeal this decision of the Building Official to the Unsafe Structures Board in accordance with Chapter 8, section 8-5 of the Miami-Dade County Code. Failure to comply by the due date will result in the Building Official requesting a hearing before the Unsafe Structures Board on the next available calendar. Unless the decision of the Unsafe Structures Board is appealed, the building or structure shall be demolished without further notice. Violation will not be closed until final inspection is obtained in the related permits to close the case. Code Description l BV-9165 THE CITY OF MIAMI BEACH MUNICIPAL CODE 14-61(b) UNSAFE STRUCTURES- FEES (c) PENAL TY IS IMPOSED WHEN NO PERMIT IS OBTAINED ON WORK FOR WHICH A PERMIT IS REQUIRED. THE APPLICANT SHALL BE REQUIRED TO PAY $500.00 PLUS DOUBLE FEES FOR A PERMIT, AS SPECIFIED HEREIN AS THE COST OF THE PERMIT. THE PAYMENT OF A PERMIT FEE SHALL NOT RELIEVE ANY PERSON, FIRM, OR CORPORA TION FROM FULLY COMPLYING WITH THE REQUIREMENTS OF THIS CODE, NOR FROM ANY OTHER PENAL TIES PRESCRIBED THEREIN. 2:30PM Special Master Case# SMB2020-00830 Department Violation # US2020-03420 AREA Fine Inspection Description: Zone4 Inspector Gabi Chamoun Comments: Violation Type: SM Initial Hearing Property Address: 71 RETAIL LLC Status: Open 730 71 ST REQUEST FOR EXTENSION (TIMELY) NOTICE OF VIOLA TION ISSUED. Process 40YR1901480 not in compliance; therefore, as per the Florida Building Code and Miami- Dade County chapter 8-5 (6), the property is deemed unsafe if a 40Year Recertification report is not completed. You must have the 40Year Recertification. Process(s) needs to be completed within thirty calendar days from the posting of this notice. Penalty of $500.00 has been applied. Sec. 8-5. - Unsafe Structures (6), Buildings or structures subject to the recertification requirements in Section 8-11 (f) of this Code which the owner fails to timely respond to the Notice of Required Inspection or fails to make all required repairs or modifications found to be necessary resulting from the recertification inspection by the deadline specified in the Code or any written extension granted by the Building Official will be demolished. Code Description [ BV-7015 FAILURE TO PROVIDE THE BUILDING DEPARTMENT WITH TH E REQUIRED RE-CERTIFICATION OF OLDER BUILDINGS REPORT. Revised: 2/14/2023 12:29:25 PM Page 26 of 29 M IA M I B E A C H 2:30PM Special Master Case# SMB2022-01496 Department Violation # US2021-03937 AREA Fire Inspection Zone 2 Inspector Comments: Ibrahim Alvarez Description: Violation Type: SM Initial Hearing Property Address: 821 COLLINS AVE GAUL I CONDOMINIUM ASSOCIATION INC Status: Open R/S---PIS NOTICE OF VIOLATION ISSUED. 821 COLLINS AVE Process 40YR2102039 is not in compliance; therefore, as per the Florida Building Code and Miami-Dade County chapter 8-5 (6), the property is deemed unsafe if a 40Year Recertification report is not completed. You must submit the 40Year Recertification reports within thirty calendar days from delivery of this violation. Penalty of $500.00 shall apply, and continued enforcement. If the reports are provided with deficiencies, permit(s) for repair(s) must be applied within thirty calendar days and obtained within sixty calendar days from permit process application date. Failure to comply will result in additional penalty of $500.00, and continued enforcement from the Special Magistrate's office, leading to the Unsafe structure's board. Sec. 8-5. - Unsafe Structures (6), Buildings or structures subject to the recertification requirements in Section 8-11(f) of this Code which the owner fails to timely respond to the Notice of Required Inspection or fails to make all required repairs or modifications found to be necessary resulting from the recertification inspection by the deadline specified in the Code or any written extension granted by the Building Official will be demolished. -- - ------ -~---------~ ------- - - - --------- - Code Code Description V-7015 FAILURE TO PROVIDE THE BUILDING DEPARTMENT WITH THE REQUIRED RE-CERTIFICATION OF OLDER BUILDINGS REPORT. 2:30PM Special Master Case# SMB2022-01504 Department Violation # US2020-03491 AREA Fine Inspection Description: Zone4 Inspector Adrian Avalos Comments: Violation Type: SM Initial Hearing Property Address: BEE JAY INC Status: Open 6740 HARDING AVE RIS---PIS NOTICE OF VIOLA TION ISSUED. Process 40YR1801045 not in compliance; therefore, as per the Florida Building Code and Miami- Dade County chapter 8-5 (6), the property is deemed unsafe if a 40Year Recertification report is not completed. You must have the 40Year Recertification. Process(s) completed within thirty calendar days from the posting of this notice. Penalty of $500.00 shall apply Sec. 8-5. - Unsafe Structures (6), Buildings or structures subject to the recertification requirements in Section 8-11(f) of this Code which the owner fails to timely respond to the Notice of Required Inspection or fails to make all required repairs or modifications found to be necessary resulting from the recertification inspection by the deadline specified in the Code or any written extension granted by the Building Official will be demolished. Code Code Description , BV-7015 FAILURE TO PROVIDE THE BUILDING DEPARTMENT WITH THE REQUIRED RE-CERTIFICATION OF OLDER BUILDINGS REPORT. Revised: 2/14/2023 12:29:25 PM Page 27 of 29 M IA M I BEACH 2:30PM S p e ci a l M a ste r C a s e # SMB2022-01650 D e p a rt m e n t Vi ol a tion # U S 20 18-026 19 AREA F in e In s p e ctio n D e s c rip tio n : Zone4 In s p e c to r A d ria n A v a lo s C o m m e n ts : Violation Type: S M In itia l H earing P ro p e rty A d d re ss: 6979 C O LLI N S AV E V IL A R IN O P R O P E R T Y G R O U P IN C Status: Open N E W C A S E N O T IC E O F V IO LA T IO N IS S U E D . P ro cess 40Y R 18 00 9 35 no t in co m pliance; therefo re, as per the Florida Building C ode and M iam i- D a de C o unty cha pter 8-5 (6 ), the pro perty is deem ed unsafe if a 40Y ear R ecertification report is no t com ple ted . Y o u m ust have the 40 Y ea r R e cert ification. Pro cess(s) com pleted w ithin thirty calendar days from the po sting of this no tice . Pe na lty of $500.00 shall apply S e c. 8-5 . - Un s afe S tructures (6 ), B uildings or structures su bje ct to the recertification requirem ents in Section 8-11(f) of this C o de w hich the ow ne r fails to tim ely respond to the N otice of R equired Inspection or fails to m ake all required repairs or m od ificatio ns fo und to be necessary resulting from the recertifica tion in sp ectio n by the de ad lin e sp e ci fied in the C ode or any w ritten extension granted by the Building O ffi cial w ill be de m o lishe d . Code [Code Description ] B V -70 15 FA IL U R E TO P R O V ID E TH E B U IL D IN G D E P A R T M E N T W IT H TH E R E Q U IR E D R E-C E R TIFIC A TIO N O F O LD ER B U IL D IN G S R E P O R T . 2:30PM S p e ci a l M a s te r C a se # SMB2022-01671 D e p a rt m e n t V io la ti o n # U S 2 022-0 3974 AREA Fire Inspe ction D e sc rip tio n : Zon e 5 In s p e c to r C o m m e n ts: Ib rah im A lv a rez Violation Type: S M Initial He aring P ro p e rty A dd ress: 7800 C A R LY LE A VE C A R L Y L E T O W E R S C O N D O Status: Open N E W C A S E N O T IC E O F V IO LA T IO N IS S U E D TO 7800 C A R LY LE A V E (M A STE R ) E vid e nce of W ate r in tru sio n w as observ ed at the interior of U N IT-6B . This condition w as observ ed at m u ltiple lo ca tio ns incl ud ing but not lim ited to the ceilings of the bedroom , bathro om , and kitchen . The re w as a stro ng od o r of m ildew detected upon entrance to the unit. The Associ ation m ust hire an Eng in e er to insp e ct the ro of and to subm it engineer's re port identify ing source of w a ter intru sio n an d m ethod s of repairs. N eed to obtain appro ved perm it(s) if required. A d ditional specific de tails co nce rn ing the violation together w ith photographs can be obtained fro m the Bu ilding D e pa rt m e n t V io lation Section in w riting upon request. Y o u have the rig h t to ap p ea l this deci sion of the Building O ffi cial to the U nsafe Stru ctures Board in acco rdan ce w ith C ha p te r 8, se ction 8-5 of the M iam i-D ade C ounty C ode . Failure to com ply by the due date w ill resu lt in the B u ild ing Offi cial requesting a hearing befo re the Unsafe Structures B o ard on the ne xt ava ilab le ca le ndar. Unless the decision of the U nsafe Structures Board is ap p ealed , the bu ild ing o r structure shall be dem olished w ithout further notice. V io latio n w ill no t be clo se d un til final inspection is obtained in the related perm it(s) to close the ca se . Code Code Description 1 B V -10 30 34 0 1.6 M A IN T E N A N C E : A LL B U IL DI N G S , S T R U C T U R E S , ELE C TR IC A L, G A S , M E C H A N IC A L AN D PLU M B IN G S Y S T E M S , B O T H E X IS T IN G A N D N E W , A N D A LL P A R T S TH E R E O F, SH A LL BE M A IN TA IN ED IN A SA FE AN D S A N IT A R Y C O N D IT IO N . A LL D E V IC E S O R SA FE G U A R D S W H IC H A R E R EQ U IR ED BY TH E TEC H N IC A L CO D ES W H EN C O N S T R U C T E D , A LT E R E D O R R E P A IR E D , S H A L L BE M A IN TA IN E D IN G O O D W O R K IN G O R D ER. TH E O W N ER , O R H IS D E S IG N A T E D A G E N T , S H A LL BE R E S P O N S IB L E FO R TH E M A IN T EN A N C E O F BU ILD IN G S , STR U C TU R ES, E LE C T R IC A L, G A S , M E C H A N IC A L A N D P L U M B IN G SY S T E M S . R ev ise d : 2/14 /20 23 12 :2 9 :2 5 PM Page 28 of 29 M IA M I B E A C H 2:30PM Special Master Case# SMB2022-01673 Department Violation # US2021-03598 AREA Fire Inspection Description: Zone 5 Inspector Adrian Avalos Comments: Violation Type: SM Initial Hearing Property Address: 317 71ST ST BEACH LEGAL PROPERTIES INC Status: Open NEW CASE NOTICE OF VIOLATION ISSUED.-301 71 street Structure with evidence of spalling concrete , rebars exposure - metal corrosion. Permit BC1808984 is in ABANDON status. Need to secure the area for pedestrian. Need to submit an engineer's report, signed and sealed by a professional engineer with methods of repair or structure removal . As per Florida Building Code and Miami-Dade County chapter 8-5 (6) Physical criteria (2) building is unsafe, the building Official has the authority to deem and declare the property UNSAFE. Is compliance is not achieved by 06/03/2021 the case will be sent to Miami-Dade County Unsafe Structure Board and penalty of $500.00 fees for unsafe violation will be imposed. --- ----- --- --------~---- --- -----------~------------ ~~-- ---- --- ~- Code Code Description BV-9045 MIAMI-DADE COUNTY, CHAPTER 8, SECTION 8-5 - UNSAFE STRUCTURES (b) PHYSICAL CRITERIA. (2) A BUILDING, OR PART THEREOF, SHALL BE PRESUMED TO BE UNSAFE IF: (i) THERE IS A FALLING AWAY, HANGING LOOSE OR LOOSENING OF ANY SIDING, BLOCK, BRICK, OR OTHER BUILDING MATERIAL. 2:30PM Special Master Case# SMB2022-01680 Department Violation# US2017-01309 AREA Fire Inspection Description: Zone 3 SM Initial Hearing Property Address: 2445 PINE TREE DR CHARLES HESSER Status: Open Inspector Adrian Avalos Comments: NEW CASE e,1 'e} ¢° NOTICE OF VIOLATION ISSUED. Electrical service equipment is not properly supported any longer and appears to have been altered without permits as well. Need to obtain approved permit. Code V-9065 MIAMI-DADE COUNTY, CHAPTER 8, SECTION 8-5- UNSAFE STRUCTURES (b) PHYSICAL CRITERIA. (2) A BUILDING, OR PART THEREOF, SHALL BE PRESUMED TO BE UNSAFE IF: (v) THE ELECTRICAL OR MECHANICAL INSTALLATIONS OR SYSTEMS CREATE A HAZARDOUS CONDITION CONTRARY TO THE STANDARDS OF THE BUILDING CODE. Revised: 2/14/2023 12:29:25 PM Page 29 of 29