Loading...
2016-29390 Reso NOW, THEREFORE, BE IT DULY RESOLVED BY THE MAYOR AND THE CITY COMMISSION OF THE CITY OF MIAMI BEACH, FLORIDA, that the Mayor and City Commission hereby approve, pursuant to Section 2-367(d) of the Miami Beach City Code, the sole source purchase of Spirax Sarco equipment, parts, software, service, and related items from G-Tec Equipment Services, LLC, the exclusive agent for these items in the City's geographic region, in an amount in excess of$50,000, but not to exceed the available approved FY 2015/2016 budget for these items. PASSED AND ADOPTED this // day of Pr , 2016. ATTEST: ,v. % r,uuti Alet/ 7---ji1:7• ---a �' ��� Philip -'r, ayor Rafael E. Gran o, City Clerk 4 INCORP ORATED; c 44111 CH 26 `- APPROVED AS TO FORM & LANGUAGE &FOR EXECUTION at-1011,x' . 6 -"/--C'\(6' City Attorney ^rte Date TAAGENDA120161MavlProcure nentlITS 2016-119-M71ITS 2016-119-MT GTEC SPIRAX SARCO-RESO FINAL.docx RESOLUTION NO. 2016-29390 A RESOLUTION OF THE MAYOR AND CITY COMMISSION OF THE CITY OF MIAMI BEACH, FLORIDA, AUTHORIZING, AS A SOLE SOURCE PURCHASE, THE PURCHASE OF SPIRAX SARCO METER SYSTEMS EQUIPMENT, PARTS, SOFTWARE, SERVICE, AND RELATED ITEMS, PURSUANT TO SECTION 2-367(d) OF THE MIAMI BEACH CITY CODE, FOR THE CITY'S SATELLITE CITY FLOW METERING SYSTEMS, FROM G-TEC EQUIPMENT SERVICES, LLC, THE EXCLUSIVE AGENT FOR SPRIRAX SARCO METER SYSTEMS EQUIPMENT, PARTS, SOFTWARE, SERVICE, AND RELATED ITEMS IN THE CITY'S GEOGRAPHIC REGION, IN AN AMOUNT IN EXCESS OF $50,000, BUT NOT TO EXCEED THE AVAILABLE APPROVED FY 2015/2016 BUDGET FOR THESE ITEMS. WHEREAS, the City currently has five (5) Flow Meters installed in the City's water and sewer system that are manufactured by Spirax Sarco that, from time to time, require parts, service, and replacement equipment to maintain operations; and WHEREAS, Spirax Sarco, the manufacturer of the equipment, and parts installed in the Satellite Cities flow metering systems, has notified the City that its exclusively authorized agent in the City's geographic region for Spirax Sarco brand equipment, parts, and related items, as well as the service provider, is G-Tec Equipment Services, LLC; and WHEREAS, Section 2-367(d) of the Miami Beach City Code allows for the purchase of goods and services without competitive bidding when only one source for the product or service is evident; and WHEREAS, Section 2-367(d) of the Miami Beach City Code provides that the City Commission, by simple majority vote, shall have the authority to authorize sole source purchases when the purchase amount exceeds $50,000; and WHEREAS, the Procurement Department, in its due diligence, released an Intent to Sole Source (ITS) on March 28, 2016, to publically notify prospective bidders of: 1) the City's intention to seek the required services directly from G-Tec Equipment Services, LLC., Spirax Sarco's exclusive agent; and 2) to allow those bidders who may also be authorized to sell these items to notify the City; and WHEREAS, no responses to the ITS were received; and WHEREAS, the City Manager recommends that the Mayor and City Commission of the City of Miami Beach, Florida, approve, pursuant to Section 2-367(d) of the Miami Beach City Code, the purchase of Spirax Sarco equipment, parts, software, and related items and service in an amount in excess of $50,000, but not to exceed the available approved FY 2015/2016 budget for these items, from G-Tec Equipment Services, LLC, the sole authorized agent for these items in the City's geographic region, to maintain safe, efficient and effective operations at the City's flow metering systems for Satellite Cities where this equipment is installed. This ensures that the sewer discharge into the City of Miami Beach conveyance system runs effectively and offers accuracy of billing to the Satellite Cities preventing loss of revenues. MIAMI BEAC H City of Miami Beach, 1700 Convention Center Drive, Miami Beach, Florida 33139,www.miamibeachfl.gov COMMISSION MEMORANDUM TO: Mayor Philip Levine and Members of the City Commission FROM: Jimmy L. Morales, City Manager DATE: May 11, 2016 SUBJECT: A RESOLUTION OF THE MAYOR AND CITY COMMISSION OF THE CITY OF MIAMI BEACH, FLORIDA, AUTHORIZING, AS A SOLE SOURCE PURCHASE, THE PURCHASE OF SPIRAX SARCO METER SYSTEMS EQUIPMENT, PARTS, SOFTWARE, SERVICE AND RELATED ITEMS, PURSUANT TO SECTION 2-367 (d) OF THE MIAMI BEACH CITY CODE, FOR THE CITY'S SATELLITE CITY FLOW METERING SYSTEMS, FROM G-TEC EQUIPMENT SERVICES, LLC, THE EXCLUSIVE AGENT FOR SPRIRAX SARCO METER SYSTEMS EQUIPMENT, PARTS, SOFTWARE, SERVICE AND RELATED ITEMS IN THE CITY'S GEOGRAPHIC REGION. ADMINISTRATION RECOMMENDATION Adopt the Resolution. BACKGROUND The Procurement Department has received a request from the Public Works Department to procure equipment and services in order to perform the necessary maintenance, revalidation and replacement of the Spirax Sarco flow metering systems utilized in the City's pump stations. The City currently has several Spirax Sarco metering systems deployed throughout the City's pump stations. Spirax Sarco, Inc., the manufacturer of Spirax Sarco Metering Products, has submitted documentation that services, maintenance and revalidation are only available from G-TEC Equipment Services, LLC, the only dealer authorized by Spirax Sarco to conduct sales and services on their behalf for all of their metering products. In lieu of seeking the advice of a consultant/industry expert that the required items are, in fact, only available from G- TEC Equipment Services, LLC, the Procurement Department publically released an Intent to Sole Source (ITS) No. 2016-119-MT, on March 28, 2016 requesting that, should any vendor believe it can meet the requirements of this procurement, they should provide written notification to the contracting officer for consideration. No responses to the ITS were received. Therefore, this item seeks approval to for the services by G-TEC Equipment Services, LLC of Spirax Sarco Metering Systems for the service, equipment, maintenance and revalidation of equipment and software of the meters systems for the Public Works Department. The City currently has 5 Flow Meters installed. These meters and the equipment installed in them require maintenance, parts and replacement equipment to keep them operating at efficient and effective levels, and to quickly return them to full function in the event of a failure. This ensures that the sewer discharge into the City of Miami Beach conveyance system runs effectively and offer accuracy of billing to the satellite cities preventing loss of revenues. CITY MANAGER'S RECOMMENDATION After considering the need to maintain operational and maintenance efficiencies of the City's Satellite City Flow Meters and after review of the results of the Intent to Sole Source issued by the Procurement Department, I recommend that the Mayor and City Commission approve the Resolutions authorizing sole source purchases, pursuant to Section 2-367 (d) of the Miami Beach City Code, for the purchase of various equipment and parts for the City's water and sewer pump stations from the source authorized by the manufacturer. JLM / RC /AD / MT T:\AGENDA\2016\May\Procurement\ITS-2016-119-MT GTEC SPIRAX SARCO MEMO.docx COMMISSION ITEM SUMMARY Condensed Title: A RESOLUTION OF THE MAYOR AND CITY COMMISSION OF THE CITY OF MIAMI BEACH, FLORIDA, AUTHORIZING, AS A SOLE SOURCE PURCHASE, THE PURCHASE OF SPIRAX SARCO METER SYSTEMS EQUIPMENT, PARTS, SOFTWARE, SERVICE AND RELATED ITEMS, PURSUANT TO SECTION 2-367 (d) OF THE MIAMI BEACH CITY CODE, FOR THE CITY'S SATELLITE CITY FLOW METERING SYSTEMS, FROM G- TEC EQUIPMENT SERVICES, LLC, THE EXCLUSIVE AGENT FOR SPRIRAX SARCO METER SYSTEMS EQUIPMENT, PARTS, SOFTWARE, SERVICE AND RELATED ITEMS IN THE CITY'S GEOGRAPHIC REGION, IN AN AMOUNT NOT TO EXCEED THE AVAILABLE APPROVED ANNUAL BUDGET FOR THESE ITEMS. Key Intended Outcome Supported: Build And Maintain Priority Infrastructure With Full Accountability Supporting Data (Surveys, Environmental Scan, etc.): Item Summary/Recommendation: The Procurement Department has received a request from the Public Works Department to procure equipment and services for the maintenance, repairs, replacements and related services of the Spirax Sarco flow metering systems utilized in the City's pump stations as sole source purchases. The City currently has 5 Spirax Sarco flow meters installed. These meters and require maintenance, parts and replacement equipment to keep them operating at efficient and effective levels, and to quickly return them to full function in the event of a failure. This ensures that the sewer discharges into the City of Miami Beach conveyance system are metered effectively and offers accuracy of billing to the satellite cities preventing loss of revenues. Spirax Sarco, Inc., the manufacturer of Spirax Sarco Metering Products, has notified the City that equipment, parts, and services for its meters are only available from G-TEC Equipment Services, LLC. No other dealer is authorized by the manufacturer. In lieu of seeking the advice of a consultant/industry expert that the required items are, in fact, only available from G-TEC Equipment Services, LLC, the Procurement Department publically released an Intent to Sole Source (ITS) No. 2016-119-MT, on March 28, 2016, requesting that, should any vendor believe it can provide the City with the necessary items, it should submit written notification for the City's consideration. No responses to the ITS were received. Therefore, this item seeks approval to procure the maintenance, repairs, replacements and related services for Spirax Sarco flow metering systems from by G-TEC Equipment Services, LLC, the sole dealer authorized by the manufacturer of the Spirax Sarco metering systems. After considering the need to maintain operational and maintenance efficiencies of the City's satellite city flow meters and after review of the results of the Intent to Sole Source issued by the Procurement Department, I recommend that the Mayor and City Commission approve the Resolution authorizing, pursuant to Section 2-367 (d) of the Miami Beach City Code, the purchase of maintenance, repairs, replacements and related services for the Spirax Sarco flow meter systems from the sole source authorized by the manufacturer of the equipment, G-TEC Equipment Services LLC. Services, RECOMMENDATION Adopt the Resolutions. Advisory Board Recommendation: Financial Information: Source of Amount Account Funds: 1 I OBPI Total Financial Impact Summary: All funds expended will have been previously authorized for this purpose. City Clerk's Office Legislative Tracking: Sign-Offs: fl De artment Di i •r Assistant City Manager City Manager RC q- AD ,V EC Ll., MT JLI, !I; T:\AGENDA\2016\M \Procurement\ITS-2016-119-MT GTEC SPIRAX SARCO COMMI'SI• ITEM SUMMARY.docx MI /�H A A IV`I B EAC H AGENDA ITEM C 7 7 DATE S- II� G MIAMIBEACH City of Miami Beach, 1700 Convention Center Drive, Miami Beach, Florida 33139,www.miamibeachfl.gov COM ISSION MEMORANDUM TO: Mayor Philip Levine and Members of t e City Comt ission FROM: Jimmy L. Morales, City Manager DATE: May 11, 2016 SUBJECT: A RESOLUTION OF THE MAYOR A D CITY COMMISSION OF THE CITY OF MIAMI BEACH, FLORIDA, AUTHORIZING, AS A SOL SOURCE PURCHASE, THE PURCHASE OF SPIRAX SARCO METER SYSTEMS EQUIPMENT, PARTS, SOFTWARE, SERVICE AND RELATED ITEMS, PURSUANT TO SECTION 2-367 (d) OF THE MIAMI BEACH CITY CODE, FOR THE CITY'S SATELLITE CITY FLOW METERING SYSTEMS, FROM G-TEC EQUIPMENT SERVICES, LLC, THE EXCLUSIVE AGENT FOR SPRIRAX SARCO METER SYSTEMS EQUIPMENT, PARTS, SOFTWARE, SERVICE AND RELATED ITEMS IN THE CITY'S GEOGRAPHIC REGION, IN AN AMOUNT NOT TO EXCEED THE AVAILABLE APPROVED ANNUAL BUDGET FOR THESE ITEMS. ADMINISTRATION RECOMMENDATION Adopt the Resolution. BACKGROUND The Procurement Department has received a request from the Public Works Department to procure equipment and services for the maintenance, repairs, replacements and related services of the Spirax Sarco flow metering systems utilized in the City's pump stations as sole source purchases. The City currently has 5 Spirax Sarco flow meters installed. These meters and require maintenance, parts and replacement equipment to keep them operating at efficient and effective levels, and to quickly return them to full function in the event of a failure. This ensures that the sewer discharges into the City of Miami Beach conveyance system are metered effectively and offers accuracy of billing to the satellite cities preventing loss of revenues. Spirax Sarco, Inc., the manufacturer of Spirax Sarco Metering Products, has notified the City that equipment, parts, and services for its meters are only available from G-TEC Equipment Services, LLC. No other dealer is authorized by the manufacturer. In lieu of seeking the advice of a consultant/industry expert that the required items are, in fact, only available from G-TEC Equipment Services, LLC, the Procurement Department publically released an Intent to Sole Source (ITS) No. 2016-119-MT, on March 28, 2016, requesting that, should any vendor believe it can provide the City with the necessary items, it should submit written notification for the City's consideration. No responses to the ITS were received. Therefore, this item seeks approval to procure the maintenance, repairs, replacements and related services for Spirax Sarco flow metering systems from by G-TEC Equipment Services, LLC, the sole dealer authorized by the manufacturer of the Spirax Sarco metering systems. CITY MANAGER'S RECOMMENDATION After considering the need to maintain operational and maintenance efficiencies of the City's satellite city flow meters and after review of the results of the Intent to Sole Source issued by the Procurement Department, I recommend that the Mayor and City Commission approve the Resolution authorizing, pursuant to Section 2-367 (d) of the Miami Beach City Code, the purchase of maintenance, repairs, replacements and related services for the Spirax Sarco flow meter systems from the sole source authorized by the manufacturer of the equipment, G-TEC Equipment Services, LLC. JLM/RC/AD/MT T:\AGENDA\2016\May\Procurement\ITS-2016-119-MT GTEC SPIRAX SARCO MEMO.docx MIAMI BEACH City of Miami Beach, 1755 Meridian Avenue, 3RD Floor,Miami Beach, Florida 33139,www.miomibeachfl.gov PROCUREMENT DEPRATMENT Tel: 305673-7490, Date: March 28, 2016 To: ALL INTERESTED PARTIES FROM: Martha L. Torres Procurement Coordinator marthatorresmiamibeachfl.,gov Subject: Intent to Award Pursuant to Sole Source Exemption, (ITS 2016-119-MT) This notice is released pursuant to Section 2-367 (d) of the Miami Beach City Code. The purpose of this notice is to notify an interested party that pursuant to Section 2-367 (d), of the Miami Beach City Code, intends to make a non-competitive award for the goods or services, as stated below. Goods or services required: The City of Miami Beach Public Works Department is procuring the services of a vendor to provide equipment, parts and service for the SPIRAX SARCO metering product systems installed in the City's water and sewer pump stations. Supplier to be awarded: G-Tec Equipment Services, LLC. Reason for Sole Source: G-Tec is the sole and exclusive representative for Spirax Sarco equipment, parts and related services. Estimated value of award: $40,000 annually. THIS NOTICE IS NOT A REQUEST FOR COMPETITIVE OFFERS. However, any firm that believes it can meet the requirements stated herein may give written notification to the contracting officer stated above within 7 calendar days from the date of this notice. Supporting evidence must be furnished in sufficient detail to demonstrate the ability to comply with the requirement(s) listed. Responses are due on or before April 4, 2016 a 3:00pm. A determination by the City of Miami Beach not to compete this proposed contract based on responses to this notice is solely within the discretion of the City of Miami Beach. spireyr sarco To Colleagues and Loyal Customers CC Keith Gosselin Ref Spirax Sarco Meter Sales Date September 28,2015 Spirax Sarco has contracted 0-Tee Equipment Services, LLC, to serve as our Municipal Metering Sales Representative for the state of Florida. 0-Tee is the sole representative in the state of Florida for Spirax Metering Products in the Municipal market. Please direct all sales inquiries,engineering/technical support,and purchases related to our metering products for any commercial applications in the state of Florida to the following: G-Tec Equipment Services, LLC 4122 Longfellow Drive Plant City,FL 33566 Phone: (863)660-8385 E-mail: g-tecequipmentriebotmail.corn Attn: Keith Gossclin We appreciate your interest in our products and are positioned to provide the highest level of customer service for any of your needs in the metering industry. Regards, Bare Reece Bare oot SE Regional Manager Mobile: 804-647-8490 Email: Reece.Barefootus.spiraxsarco.com spiraxsarcacomius spiry sarco EFT10 Electromagnetic Flow Transmitter Description Spirax Sarco's EFT10 Electromagnetic Flow Transmitter produces a clean and power- ` ful bidirectional flow signal with unsurpassed fast response and uniquely high signal strength. By using an innovative and patented Pulsed Hybrid method of coil excitation the EFT10 creates an ultra stable flow signal to media noise ratio up to 50 times higher than other magmeter technologies. The EFT10 is a versatile and advanced magmeter transmitter with a user-friendly keypad for programming,a 10-year memory,batch control,RS485 Modbus interface,HART,two 4-20mA outputs and a scalable pulse frequency output. Features • High excitation current (to 5.5 A base to peak) and high exciter frequency (40Hz to 33Hz)for all size full pipe sensors. • 4 lines of 20 character alpha numeric,backlit display with sealed tactile feedback and vandal resistant keyboard • Suitable for problem media(mining,slurries,and low conductivity media) • HART, Modbus RTU over RS-485,and two 4-20mA outputs • Bi-directional flow measurement;accurately eliminates back flow from net totals • Virtually immune to common noise effects, including eddy currents, radio frequency, and variable frequency drives • Reference coils to compensate for media temperature Dimensions gay ^3$enm Gin 13 t.-1 � ' n jt1_ m! - t52^rm 111 tit , 14— ,( i c o <> 111& _..... _. #4 72crroea i i 0 _. 0 ' .'2 CLY:D!.Tt f 0 ' 1 � El I tt C-) Jac --ar. 1L._ jrt f (z.r°- ..: I WM �'I `"'_ _ 0 0 D L -Tie ttOUNL FO NTs;Il MM) Local regulation may restrict the use of this product below the conditions quoted.Limiting conditions refer to standard connections only. In the interests of development and improvement of the product,we reserve the right to change the specification. TI-8-631-US 10.13 165 EFT10 Electromagnetic Flow Transmitter EFT10 Specifications Enclosure Wall mounted,UV resistant fiberglass with stainless steel screws Front Panel Keypad Tactile feedback,waterproof,vandal resistant Environmental Protection NEMA 4X(IP65) Ambient Temperature -4 to 140°F(-20 to 60°C) Supply Voltage 120VAC 60Hz, 120VAC 50Hz,230VAC 50Hz,230VAC 60Hz Power Consumption EFT10 Transmitter 6 watts typical Max for Sensors 65 watts typical All necessary diagnostics,readings and system status are available via the front panel keypad without Diagnostics opening the door.A user security password is programmable,allowing revalidation of the magmeter's NIST traceable Calibration Certificates.A separate calibration box is not necessary Windows Interface Program Computer interface via RS-232 serial connection,enabling programming of setup,and downloading diagnostics and status. Magnetizing Current Up to 5.5 A base to peak,depending on sensor size Exciter Frequency 40Hz(with 60Hz supply)or 33.3Hz(with 50Hz supply) Time Constant(T) Minimum of 30 milliseconds Signal Averaging(ST) 0 to 300 seconds Optional Batch Control For batch control,the total set amount is entered via the keypad and displayed. Keypad activation of batch flow via a EFT10 relay initiates flow,counting from zero to the total set point amount. Frequency Mode 0- 1,000Hz, 0-2,000Hz, 0-5,000Hz,0- 10,000Hz Analog Outputs Two,4-20mA outputs from separate terminals are available for bi-directional flow. Either may be configured as an internally powered 2-wire output or an externally powered 2-wire output Pulsed Outputs An externally powered,2 wired scaled output(for totalizing flow),or frequency output(for rate of flow) Relay Outputs Two user configurable form C(changeover)relays with contact rate 125VAC, 1A,30VA Contact Inputs Two user configurable inputs,rated 12volts DC, 10 mA.These inputs require a contact closure or transistor switch between the terminals. Modbus Output Modbus RS-485(RTU) HART Output Supports HART 7 protocol; HART registration pending Input Impedance 1012 Ohms Pre-Amp Supply A pre-amp is supplied standard on all products,for use on media with conductivity>0.8pS/cm Maximum Cable Length Max cable length for fluids with conductivity<5 pS/cm,50 feet Max cable length for fluids with conductivity>5pS/cm ,300 feet UniMag products supported Full pipe meters only. UniMag M, DT, DM, DL, Delta Kit, DeltaMass Flow Range 0.6 to 32 feet/second(0.2 to 9.7 m/sec) System Accuracy(with flow UniMag M, DT, DM,and DL velocities+/-0.5%of rate for flows to>8.0 fps;+/-0.048 fps for flows<8.0 tube) fps. DeltaKit and DeltaMass+/- 1.0%of rate for flows to>8.0 fps;+/-0.096 fps for flows to<8.0 fps Approvals UL pending Part Numbers Description Part Number EFT10 with 120VAC,60Hz power EC007102 EFT10 with 120VAC,50Hz power EC007100 EFT10 with 230VAC,50Hz power EC007101 EFT10 with 230VAC, 60Hz power EC007103 Notes 1 The EFT10 Flow Transmitter must be operated in a safe area. 2 Currently the EFT10 is NOT PED approved for sales into European Union countries. O C O O I9 VI m a U) Spirax Sarco Inc.•2150 Miller Drive•Longmont,CO 80501 •Telephone:(303)682-7060•Fax:(303)682-7069 TI-8-631-US 10.13 166 spiry sarco MAGFLO MAG 5100 W Benefits • DN 25 to DN 1200(1"to 48") • Connection flanges EN 1092-1 (DIN 2501),ANSI,AWWA and AS. • Ebonite Hard Rubber liner for all water applications • Hastelloy Integrated grounding and measuring electrodes • Increased low flow accuracy for water leak detection,due to coned liner design. ,r; • Drinking water approvals • 1 _ • Suitable for direct burial and constant flooding • Build-in length according to ISO 13359 • Easy commissioning,SENSORPROM unit automatically up-loads calibration values and settings „` • Designed that patented in-situ verification can be conducted. Using SENSORPROM fingerprint. Application The main applications of the MAGFLO electromagnetic flow sensors - can be found in the following fields: • Water abstraction • Water treatment • Water distribution network(leak detection management) • Custody transfer water meters 'w, • Irrigation • Waste water treatment • Filtration plant(e.g.reverse osmosis and ultra filtration • Industrial Water applications • Mode of operation The flow measuring principle is based on Faradays law of electromagnetic Induction were the sensor converts the flow into an electrical voltage proportional to the velocity of the flow. Function • Highly resistant to a wide range of chemicals — OIML R49 and PTB approved —Conforms to ISO 4064 and EN 14154 — MI-0001 Custody Transfer approval for billing • Meets EEC directives:PED,97/23/EC pressure directive for#N 1092-1 flanges • Simple onsite of factory upgrade to IP68/NEMA 6P of standard sensor. Integration The complete flow meter consists of a flow sensor and an associated transmitter MAGFLO MAG 5000 or MAG 6000 Local regulation may restrict the use of this product below the conditions quoted.Limiting conditions refer to standard connections only. In the interests of development and improvement of the product,we reserve the right to change the specification. TI-8-628-US 02.11 152 MAGFLO MAG 5100W Technical Specifications Design Full bore sensor Coned bore sensor Full bore sensor Nominal size DN 25...40(1" ...1 1/2") DN 50...300(2" ...12") DN 350...1200(14"...48") Measuring principle Electromagnetic induction Excitation frequency 12.5 Hz •50...65mm(2" ...2'h"):12.5 Hz DN 350...450(14" ...18"):3.125Hz •80 ...150mm(3" ...6"):6.25 Hz DN 500... 1200(20" ...48"):1.5625 Hz •200...300mm(8" ...12"):3.125 Hz Process connection Flanges •ANSI B 16.5 Class 150 lb Class 150 lb-20 bar(290 psi) •AWWA C-207 - - 28" ...48":Class D • Rated Operation Conditions Ambient temperature •Sensor -40...+70°C(-40...+158°F) •With Compact transmitter -20...+50°C(-4...+122°F) MAG 5000/6000 Operating pressure 0.01 ...40bar(0.15...580 psi) 0.03...20 bar(0.44...290psi) 0.01...16 bar(0.15...232psi) Enclosure rating •Standard IP67 to EN 60529/NEMA 4x/6(1 mH2O for 30 minutes) •Optiion IP68 to EN 60529/NEMA 6P(40 mH2O continously) Pressure drop at 3 m/s(10 fUs) As straight pipe Max.25 mbar(0.36 psi) As straight pipe Medium conditions Temperature of medium •Ebonite -10...+70°C{14...+158°F) EMC 89/336 EEC Design Weight See dimensional drawings Material •Housing and flanges Carbon steel,St 37.2 •Terminal box Standard Fibre glass reinforced polyamide •Measuring pipe AISI 304(1.4301) •Liner Ebonite Hard Rubber(hydro carbon resistent) •Electrodes Hastelloy C276 •Grounding electrodes standard Hastelloy C276 Certificates and approvals Custody Transfer(only together OIML R 49 cold water(2"...12") with MAG 5000/6000 CT) MI 001 cold water(2"...12") Approvals FM Class 1,Div 2 CSA Class 1,Div 2 Approvals CRN Spirax Sarco Inc.•2150 Miller Drive•Longmont,CO 80501•Telephone:(303)682-7060•Fax:(303)682-7069 TI-8-628-US 02.11 153 MAGFLO MAG 5100W II I( II I) II II II II Iiii M20(W NPT) I I M20(1/2 NPT) Eli 1" - 11/2" _�I'I 14" 48" -- 2" - 12" / r i - - - L L Nominal Size A L Weight Class 150/ Class 150/ AWWA AWWA [mm] [inch] [inch] [inch] [Ibs] 25 1 7.4 7.9 9 40 11/2 7.8 7.9 13 50 2 7.4 7.9 20 65 21/2 7.6 7.9 24 80 3 7.9 7.9 28 100 4 8.1 9.8 41 125 5 8.5 9.8 52 150 6 9.1 11.8 64 200 8 10.1 13.8 124 250 10 11.2 17.7 174 300 12 12.2 19.7 243 350 14 15.0 21.7 307 400 16 16.0 23.6 351 450 18 17.2 23.6 400 500 20 18.2 23.6 495 600 24 20.2 23.6 704 700 28 22.2 27.6 602 750 30 23.3 29.5 725 800 32 24.3 31.5 804 900 36 26.1 35.4 1089 1000 40 28.1 39.4 1282 42 28.1 39.4 1512 44 30.1 43.3 1680 1200 48 32.3 47.2 1896 Spirax Sarco Inc.•2150 Miller Drive•Longmont,CO 80501 •Telephone:(303)682-7060•Fax:(303)682-7069 TI-8-628-US 02.11 154 MAGFLO MAG 5100W Model Code MAG 5100 W DESCRIPTION SIZE (IN.) CODE No FLANGE Sensor MAG 5100 W-Hard Rubber Liner(ebonite) Liner:Ebonite 1" 7ME6580-2DJ14-2AA2 150#ANSI Accuracy:0.5%of rate 1 1 " 7ME6580-2RJ14-2AA2 150#ANSI Electrodes:Hastelloy C 2" 7ME6580-2YJ14-2AA2 150#ANSI Enclosure:NEMA 4X,NEMA 6* 2 1/2" 7ME6580-2FJ14-2AA2 150#ANSI (3-ft.submersible up to 72 hours) 3" 7ME6580-3MJ14-2AA2 150#ANSI Flange Material:Carbon Steel 4" 7ME6580-3TJ14-2AA2 150#ANSI Sizes 1"to 24":ANSI 16.5B,Class 150 5" 7ME6580-4BJ14-2AA2 150#ANSI Sizes 28"to 48":AWWA C-207,Class D 6" ' 7ME6580-4HJ14-2AA2 150#ANSI Max Temp: 158°F(70°C) 8" 7ME6580-4PJ14-2M2 150#ANSI *NEMA 6P when applying submersible kit part# 085U0220 10" 7ME6580-4VJ14-2AA2 150#ANSI 12" 7ME6580-5DJ14-2AA2 150#ANSI Code numbers in Bold Type indicate items ordinarily in stock. 14" 7ME6580-5KJ14-2AA2 150#ANSI Consult factory for confirmation. 16" 7ME6580-5RJ14-2AA2 150#ANSI 18" 7ME6580-5YJ14-2AA2 150#ANSI 20" 7ME6580-6FJ14-2M2 150#ANSI Coned Design 24" 7ME6580-6PJ14-2AA2 150#ANSI 28" 7ME6580-6YL14-2AA2 AWWA 30" 7ME6580-7DL14-2M2 AWWA 32" 7ME6580-7HL14-2M2 AWWA 36" 7ME6580-7ML14-2AA2 AWWA 40" 7ME6580-7RL14-2M2 AWWA 42" 7ME6580-7UL14-2AA2 AWWA 44" 7ME6580-7VL14-2AA2 AWWA 48" 7ME6580-8BL14-2AA2 AWWA Spirax Sarco Inc.•2150 Miller Drive•Longmont,CO 80501 •Telephone:(303)682-7060•Fax:(303)682-7069 TI-8-628-US 02.11 155