2016-29390 Reso NOW, THEREFORE, BE IT DULY RESOLVED BY THE MAYOR AND THE CITY
COMMISSION OF THE CITY OF MIAMI BEACH, FLORIDA, that the Mayor and City
Commission hereby approve, pursuant to Section 2-367(d) of the Miami Beach City Code, the
sole source purchase of Spirax Sarco equipment, parts, software, service, and related items
from G-Tec Equipment Services, LLC, the exclusive agent for these items in the City's
geographic region, in an amount in excess of$50,000, but not to exceed the available approved
FY 2015/2016 budget for these items.
PASSED AND ADOPTED this // day of Pr , 2016.
ATTEST: ,v. % r,uuti
Alet/
7---ji1:7• ---a �' ��� Philip -'r, ayor
Rafael E. Gran o, City Clerk 4 INCORP ORATED; c
44111 CH 26 `-
APPROVED AS TO
FORM & LANGUAGE
&FOR EXECUTION
at-1011,x' . 6 -"/--C'\(6'
City Attorney ^rte Date
TAAGENDA120161MavlProcure nentlITS 2016-119-M71ITS 2016-119-MT GTEC SPIRAX SARCO-RESO FINAL.docx
RESOLUTION NO. 2016-29390
A RESOLUTION OF THE MAYOR AND CITY COMMISSION OF THE CITY OF
MIAMI BEACH, FLORIDA, AUTHORIZING, AS A SOLE SOURCE PURCHASE,
THE PURCHASE OF SPIRAX SARCO METER SYSTEMS EQUIPMENT,
PARTS, SOFTWARE, SERVICE, AND RELATED ITEMS, PURSUANT TO
SECTION 2-367(d) OF THE MIAMI BEACH CITY CODE, FOR THE CITY'S
SATELLITE CITY FLOW METERING SYSTEMS, FROM G-TEC EQUIPMENT
SERVICES, LLC, THE EXCLUSIVE AGENT FOR SPRIRAX SARCO METER
SYSTEMS EQUIPMENT, PARTS, SOFTWARE, SERVICE, AND RELATED
ITEMS IN THE CITY'S GEOGRAPHIC REGION, IN AN AMOUNT IN EXCESS
OF $50,000, BUT NOT TO EXCEED THE AVAILABLE APPROVED FY
2015/2016 BUDGET FOR THESE ITEMS.
WHEREAS, the City currently has five (5) Flow Meters installed in the City's water and
sewer system that are manufactured by Spirax Sarco that, from time to time, require parts,
service, and replacement equipment to maintain operations; and
WHEREAS, Spirax Sarco, the manufacturer of the equipment, and parts installed in the
Satellite Cities flow metering systems, has notified the City that its exclusively authorized agent
in the City's geographic region for Spirax Sarco brand equipment, parts, and related items, as
well as the service provider, is G-Tec Equipment Services, LLC; and
WHEREAS, Section 2-367(d) of the Miami Beach City Code allows for the purchase of
goods and services without competitive bidding when only one source for the product or service
is evident; and
WHEREAS, Section 2-367(d) of the Miami Beach City Code provides that the City
Commission, by simple majority vote, shall have the authority to authorize sole source
purchases when the purchase amount exceeds $50,000; and
WHEREAS, the Procurement Department, in its due diligence, released an Intent to
Sole Source (ITS) on March 28, 2016, to publically notify prospective bidders of: 1) the City's
intention to seek the required services directly from G-Tec Equipment Services, LLC., Spirax
Sarco's exclusive agent; and 2) to allow those bidders who may also be authorized to sell these
items to notify the City; and
WHEREAS, no responses to the ITS were received; and
WHEREAS, the City Manager recommends that the Mayor and City Commission of the
City of Miami Beach, Florida, approve, pursuant to Section 2-367(d) of the Miami Beach City
Code, the purchase of Spirax Sarco equipment, parts, software, and related items and service
in an amount in excess of $50,000, but not to exceed the available approved FY 2015/2016
budget for these items, from G-Tec Equipment Services, LLC, the sole authorized agent for
these items in the City's geographic region, to maintain safe, efficient and effective operations at
the City's flow metering systems for Satellite Cities where this equipment is installed. This
ensures that the sewer discharge into the City of Miami Beach conveyance system runs
effectively and offers accuracy of billing to the Satellite Cities preventing loss of revenues.
MIAMI BEAC H
City of Miami Beach, 1700 Convention Center Drive, Miami Beach, Florida 33139,www.miamibeachfl.gov
COMMISSION MEMORANDUM
TO: Mayor Philip Levine and Members of the City Commission
FROM: Jimmy L. Morales, City Manager
DATE: May 11, 2016
SUBJECT: A RESOLUTION OF THE MAYOR AND CITY COMMISSION OF THE CITY OF MIAMI
BEACH, FLORIDA, AUTHORIZING, AS A SOLE SOURCE PURCHASE, THE PURCHASE OF SPIRAX
SARCO METER SYSTEMS EQUIPMENT, PARTS, SOFTWARE, SERVICE AND RELATED ITEMS,
PURSUANT TO SECTION 2-367 (d) OF THE MIAMI BEACH CITY CODE, FOR THE CITY'S SATELLITE CITY
FLOW METERING SYSTEMS, FROM G-TEC EQUIPMENT SERVICES, LLC, THE EXCLUSIVE AGENT FOR
SPRIRAX SARCO METER SYSTEMS EQUIPMENT, PARTS, SOFTWARE, SERVICE AND RELATED ITEMS
IN THE CITY'S GEOGRAPHIC REGION.
ADMINISTRATION RECOMMENDATION
Adopt the Resolution.
BACKGROUND
The Procurement Department has received a request from the Public Works Department to procure equipment
and services in order to perform the necessary maintenance, revalidation and replacement of the Spirax Sarco
flow metering systems utilized in the City's pump stations.
The City currently has several Spirax Sarco metering systems deployed throughout the City's pump stations.
Spirax Sarco, Inc., the manufacturer of Spirax Sarco Metering Products, has submitted documentation that
services, maintenance and revalidation are only available from G-TEC Equipment Services, LLC, the only dealer
authorized by Spirax Sarco to conduct sales and services on their behalf for all of their metering products. In lieu
of seeking the advice of a consultant/industry expert that the required items are, in fact, only available from G-
TEC Equipment Services, LLC, the Procurement Department publically released an Intent to Sole Source (ITS)
No. 2016-119-MT, on March 28, 2016 requesting that, should any vendor believe it can meet the requirements of
this procurement, they should provide written notification to the contracting officer for consideration. No
responses to the ITS were received.
Therefore, this item seeks approval to for the services by G-TEC Equipment Services, LLC of Spirax Sarco
Metering Systems for the service, equipment, maintenance and revalidation of equipment and software of the
meters systems for the Public Works Department.
The City currently has 5 Flow Meters installed. These meters and the equipment installed in them require
maintenance, parts and replacement equipment to keep them operating at efficient and effective levels, and to
quickly return them to full function in the event of a failure. This ensures that the sewer discharge into the City of
Miami Beach conveyance system runs effectively and offer accuracy of billing to the satellite cities preventing
loss of revenues.
CITY MANAGER'S RECOMMENDATION
After considering the need to maintain operational and maintenance efficiencies of the City's Satellite City Flow
Meters and after review of the results of the Intent to Sole Source issued by the Procurement Department, I
recommend that the Mayor and City Commission approve the Resolutions authorizing sole source purchases,
pursuant to Section 2-367 (d) of the Miami Beach City Code, for the purchase of various equipment and parts for
the City's water and sewer pump stations from the source authorized by the manufacturer.
JLM / RC /AD / MT
T:\AGENDA\2016\May\Procurement\ITS-2016-119-MT GTEC SPIRAX SARCO MEMO.docx
COMMISSION ITEM SUMMARY
Condensed Title:
A RESOLUTION OF THE MAYOR AND CITY COMMISSION OF THE CITY OF MIAMI BEACH, FLORIDA,
AUTHORIZING, AS A SOLE SOURCE PURCHASE, THE PURCHASE OF SPIRAX SARCO METER SYSTEMS
EQUIPMENT, PARTS, SOFTWARE, SERVICE AND RELATED ITEMS, PURSUANT TO SECTION 2-367 (d) OF
THE MIAMI BEACH CITY CODE, FOR THE CITY'S SATELLITE CITY FLOW METERING SYSTEMS, FROM G-
TEC EQUIPMENT SERVICES, LLC, THE EXCLUSIVE AGENT FOR SPRIRAX SARCO METER SYSTEMS
EQUIPMENT, PARTS, SOFTWARE, SERVICE AND RELATED ITEMS IN THE CITY'S GEOGRAPHIC REGION,
IN AN AMOUNT NOT TO EXCEED THE AVAILABLE APPROVED ANNUAL BUDGET FOR THESE ITEMS.
Key Intended Outcome Supported:
Build And Maintain Priority Infrastructure With Full Accountability
Supporting Data (Surveys, Environmental Scan, etc.):
Item Summary/Recommendation:
The Procurement Department has received a request from the Public Works Department to procure equipment and
services for the maintenance, repairs, replacements and related services of the Spirax Sarco flow metering
systems utilized in the City's pump stations as sole source purchases.
The City currently has 5 Spirax Sarco flow meters installed. These meters and require maintenance, parts and
replacement equipment to keep them operating at efficient and effective levels, and to quickly return them to full
function in the event of a failure. This ensures that the sewer discharges into the City of Miami Beach conveyance
system are metered effectively and offers accuracy of billing to the satellite cities preventing loss of revenues.
Spirax Sarco, Inc., the manufacturer of Spirax Sarco Metering Products, has notified the City that equipment, parts,
and services for its meters are only available from G-TEC Equipment Services, LLC. No other dealer is authorized
by the manufacturer. In lieu of seeking the advice of a consultant/industry expert that the required items are, in fact,
only available from G-TEC Equipment Services, LLC, the Procurement Department publically released an Intent to
Sole Source (ITS) No. 2016-119-MT, on March 28, 2016, requesting that, should any vendor believe it can provide
the City with the necessary items, it should submit written notification for the City's consideration. No responses to
the ITS were received.
Therefore, this item seeks approval to procure the maintenance, repairs, replacements and related services for
Spirax Sarco flow metering systems from by G-TEC Equipment Services, LLC, the sole dealer authorized by the
manufacturer of the Spirax Sarco metering systems.
After considering the need to maintain operational and maintenance efficiencies of the City's satellite city flow
meters and after review of the results of the Intent to Sole Source issued by the Procurement Department, I
recommend that the Mayor and City Commission approve the Resolution authorizing, pursuant to Section 2-367 (d)
of the Miami Beach City Code, the purchase of maintenance, repairs, replacements and related services for the
Spirax Sarco flow meter systems from the sole source authorized by the manufacturer of the equipment, G-TEC
Equipment Services LLC.
Services,
RECOMMENDATION
Adopt the Resolutions.
Advisory Board Recommendation:
Financial Information:
Source of Amount Account
Funds: 1 I
OBPI Total
Financial Impact Summary: All funds expended will have been previously authorized for this purpose.
City Clerk's Office Legislative Tracking:
Sign-Offs: fl
De artment Di i •r Assistant City Manager City Manager
RC q- AD ,V EC Ll., MT JLI, !I;
T:\AGENDA\2016\M \Procurement\ITS-2016-119-MT GTEC SPIRAX SARCO COMMI'SI• ITEM SUMMARY.docx
MI /�H A A IV`I B EAC H AGENDA ITEM C 7 7
DATE S- II� G
MIAMIBEACH
City of Miami Beach, 1700 Convention Center Drive, Miami Beach, Florida 33139,www.miamibeachfl.gov
COM ISSION MEMORANDUM
TO: Mayor Philip Levine and Members of t e City Comt ission
FROM: Jimmy L. Morales, City Manager
DATE: May 11, 2016
SUBJECT: A RESOLUTION OF THE MAYOR A D CITY COMMISSION OF THE CITY OF MIAMI
BEACH, FLORIDA, AUTHORIZING, AS A SOL SOURCE PURCHASE, THE PURCHASE OF
SPIRAX SARCO METER SYSTEMS EQUIPMENT, PARTS, SOFTWARE, SERVICE AND RELATED
ITEMS, PURSUANT TO SECTION 2-367 (d) OF THE MIAMI BEACH CITY CODE, FOR THE CITY'S
SATELLITE CITY FLOW METERING SYSTEMS, FROM G-TEC EQUIPMENT SERVICES, LLC, THE
EXCLUSIVE AGENT FOR SPRIRAX SARCO METER SYSTEMS EQUIPMENT, PARTS,
SOFTWARE, SERVICE AND RELATED ITEMS IN THE CITY'S GEOGRAPHIC REGION, IN AN
AMOUNT NOT TO EXCEED THE AVAILABLE APPROVED ANNUAL BUDGET FOR THESE
ITEMS.
ADMINISTRATION RECOMMENDATION
Adopt the Resolution.
BACKGROUND
The Procurement Department has received a request from the Public Works Department to procure
equipment and services for the maintenance, repairs, replacements and related services of the Spirax
Sarco flow metering systems utilized in the City's pump stations as sole source purchases.
The City currently has 5 Spirax Sarco flow meters installed. These meters and require maintenance,
parts and replacement equipment to keep them operating at efficient and effective levels, and to
quickly return them to full function in the event of a failure. This ensures that the sewer discharges into
the City of Miami Beach conveyance system are metered effectively and offers accuracy of billing to
the satellite cities preventing loss of revenues.
Spirax Sarco, Inc., the manufacturer of Spirax Sarco Metering Products, has notified the City that
equipment, parts, and services for its meters are only available from G-TEC Equipment Services, LLC.
No other dealer is authorized by the manufacturer. In lieu of seeking the advice of a
consultant/industry expert that the required items are, in fact, only available from G-TEC Equipment
Services, LLC, the Procurement Department publically released an Intent to Sole Source (ITS) No.
2016-119-MT, on March 28, 2016, requesting that, should any vendor believe it can provide the City
with the necessary items, it should submit written notification for the City's consideration. No
responses to the ITS were received.
Therefore, this item seeks approval to procure the maintenance, repairs, replacements and related
services for Spirax Sarco flow metering systems from by G-TEC Equipment Services, LLC, the sole
dealer authorized by the manufacturer of the Spirax Sarco metering systems.
CITY MANAGER'S RECOMMENDATION
After considering the need to maintain operational and maintenance efficiencies of the City's satellite
city flow meters and after review of the results of the Intent to Sole Source issued by the Procurement
Department, I recommend that the Mayor and City Commission approve the Resolution authorizing,
pursuant to Section 2-367 (d) of the Miami Beach City Code, the purchase of maintenance, repairs,
replacements and related services for the Spirax Sarco flow meter systems from the sole source
authorized by the manufacturer of the equipment, G-TEC Equipment Services, LLC.
JLM/RC/AD/MT
T:\AGENDA\2016\May\Procurement\ITS-2016-119-MT GTEC SPIRAX SARCO MEMO.docx
MIAMI BEACH
City of Miami Beach, 1755 Meridian Avenue, 3RD Floor,Miami Beach, Florida 33139,www.miomibeachfl.gov
PROCUREMENT DEPRATMENT
Tel: 305673-7490,
Date: March 28, 2016
To: ALL INTERESTED PARTIES
FROM: Martha L. Torres
Procurement Coordinator
marthatorresmiamibeachfl.,gov
Subject: Intent to Award Pursuant to Sole Source Exemption, (ITS 2016-119-MT)
This notice is released pursuant to Section 2-367 (d) of the Miami Beach City Code. The
purpose of this notice is to notify an interested party that pursuant to Section 2-367 (d), of the
Miami Beach City Code, intends to make a non-competitive award for the goods or services, as
stated below.
Goods or services required:
The City of Miami Beach Public Works Department is procuring the services of a vendor to
provide equipment, parts and service for the SPIRAX SARCO metering product systems
installed in the City's water and sewer pump stations.
Supplier to be awarded: G-Tec Equipment Services, LLC.
Reason for Sole Source:
G-Tec is the sole and exclusive representative for Spirax Sarco equipment, parts and related
services.
Estimated value of award: $40,000 annually.
THIS NOTICE IS NOT A REQUEST FOR COMPETITIVE OFFERS. However, any firm that
believes it can meet the requirements stated herein may give written notification to the
contracting officer stated above within 7 calendar days from the date of this notice. Supporting
evidence must be furnished in sufficient detail to demonstrate the ability to comply with the
requirement(s) listed. Responses are due on or before April 4, 2016 a 3:00pm. A
determination by the City of Miami Beach not to compete this proposed contract based on
responses to this notice is solely within the discretion of the City of Miami Beach.
spireyr
sarco
To Colleagues and Loyal Customers
CC Keith Gosselin
Ref Spirax Sarco Meter Sales
Date September 28,2015
Spirax Sarco has contracted 0-Tee Equipment Services, LLC, to serve as our Municipal
Metering Sales Representative for the state of Florida. 0-Tee is the sole representative in
the state of Florida for Spirax Metering Products in the Municipal market.
Please direct all sales inquiries,engineering/technical support,and purchases related to our
metering products for any commercial applications in the state of Florida to the following:
G-Tec Equipment Services, LLC
4122 Longfellow Drive
Plant City,FL 33566
Phone: (863)660-8385
E-mail: g-tecequipmentriebotmail.corn
Attn: Keith Gossclin
We appreciate your interest in our products and are positioned to provide the highest level
of customer service for any of your needs in the metering industry.
Regards,
Bare Reece Bare oot
SE Regional Manager
Mobile: 804-647-8490
Email: Reece.Barefootus.spiraxsarco.com
spiraxsarcacomius
spiry
sarco
EFT10 Electromagnetic Flow Transmitter
Description
Spirax Sarco's EFT10 Electromagnetic Flow Transmitter produces a clean and power- `
ful bidirectional flow signal with unsurpassed fast response and uniquely high signal
strength.
By using an innovative and patented Pulsed Hybrid method of coil excitation the EFT10
creates an ultra stable flow signal to media noise ratio up to 50 times higher than other
magmeter technologies.
The EFT10 is a versatile and advanced magmeter transmitter with a user-friendly keypad
for programming,a 10-year memory,batch control,RS485 Modbus interface,HART,two
4-20mA outputs and a scalable pulse frequency output.
Features
• High excitation current (to 5.5 A base to peak) and high exciter frequency (40Hz to
33Hz)for all size full pipe sensors.
• 4 lines of 20 character alpha numeric,backlit display with sealed tactile feedback and
vandal resistant keyboard
• Suitable for problem media(mining,slurries,and low conductivity media)
• HART, Modbus RTU over RS-485,and two 4-20mA outputs
• Bi-directional flow measurement;accurately eliminates back flow from net totals
• Virtually immune to common noise effects, including eddy currents, radio frequency,
and variable frequency drives
• Reference coils to compensate for media temperature
Dimensions
gay
^3$enm Gin
13 t.-1 � '
n jt1_ m! -
t52^rm
111 tit , 14— ,(
i c
o
<>
111& _..... _. #4 72crroea i i 0 _. 0 '
.'2 CLY:D!.Tt
f 0 ' 1 � El
I tt C-) Jac
--ar. 1L._ jrt f (z.r°-
..: I WM
�'I `"'_ _
0 0
D
L
-Tie ttOUNL FO NTs;Il MM)
Local regulation may restrict the use of this product below the conditions quoted.Limiting conditions refer to standard connections only.
In the interests of development and improvement of the product,we reserve the right to change the specification. TI-8-631-US 10.13
165
EFT10 Electromagnetic Flow Transmitter
EFT10 Specifications
Enclosure Wall mounted,UV resistant fiberglass with stainless steel screws
Front Panel Keypad Tactile feedback,waterproof,vandal resistant
Environmental Protection NEMA 4X(IP65)
Ambient Temperature -4 to 140°F(-20 to 60°C)
Supply Voltage 120VAC 60Hz, 120VAC 50Hz,230VAC 50Hz,230VAC 60Hz
Power Consumption EFT10 Transmitter 6 watts typical
Max for Sensors 65 watts typical
All necessary diagnostics,readings and system status are available via the front panel keypad without
Diagnostics opening the door.A user security password is programmable,allowing revalidation of the magmeter's
NIST traceable Calibration Certificates.A separate calibration box is not necessary
Windows Interface Program Computer interface via RS-232 serial connection,enabling programming of setup,and downloading
diagnostics and status.
Magnetizing Current Up to 5.5 A base to peak,depending on sensor size
Exciter Frequency 40Hz(with 60Hz supply)or 33.3Hz(with 50Hz supply)
Time Constant(T) Minimum of 30 milliseconds
Signal Averaging(ST) 0 to 300 seconds
Optional Batch Control For batch control,the total set amount is entered via the keypad and displayed. Keypad activation of
batch flow via a EFT10 relay initiates flow,counting from zero to the total set point amount.
Frequency Mode 0- 1,000Hz, 0-2,000Hz, 0-5,000Hz,0- 10,000Hz
Analog Outputs Two,4-20mA outputs from separate terminals are available for bi-directional flow. Either may be
configured as an internally powered 2-wire output or an externally powered 2-wire output
Pulsed Outputs An externally powered,2 wired scaled output(for totalizing flow),or frequency output(for rate of flow)
Relay Outputs Two user configurable form C(changeover)relays with contact rate 125VAC, 1A,30VA
Contact Inputs Two user configurable inputs,rated 12volts DC, 10 mA.These inputs require a contact closure or
transistor switch between the terminals.
Modbus Output Modbus RS-485(RTU)
HART Output Supports HART 7 protocol; HART registration pending
Input Impedance 1012 Ohms
Pre-Amp Supply A pre-amp is supplied standard on all products,for use on media with conductivity>0.8pS/cm
Maximum Cable Length Max cable length for fluids with conductivity<5 pS/cm,50 feet
Max cable length for fluids with conductivity>5pS/cm ,300 feet
UniMag products supported Full pipe meters only. UniMag M, DT, DM, DL, Delta Kit, DeltaMass
Flow Range 0.6 to 32 feet/second(0.2 to 9.7 m/sec)
System Accuracy(with flow UniMag M, DT, DM,and DL velocities+/-0.5%of rate for flows to>8.0 fps;+/-0.048 fps for flows<8.0
tube) fps.
DeltaKit and DeltaMass+/- 1.0%of rate for flows to>8.0 fps;+/-0.096 fps for flows to<8.0 fps
Approvals UL pending
Part Numbers
Description Part Number
EFT10 with 120VAC,60Hz power EC007102
EFT10 with 120VAC,50Hz power EC007100
EFT10 with 230VAC,50Hz power EC007101
EFT10 with 230VAC, 60Hz power EC007103
Notes
1 The EFT10 Flow Transmitter must be operated in a safe area.
2 Currently the EFT10 is NOT PED approved for sales into European Union countries.
O
C
O
O
I9
VI
m
a
U)
Spirax Sarco Inc.•2150 Miller Drive•Longmont,CO 80501 •Telephone:(303)682-7060•Fax:(303)682-7069 TI-8-631-US 10.13
166
spiry
sarco
MAGFLO MAG 5100 W
Benefits
• DN 25 to DN 1200(1"to 48")
• Connection flanges EN 1092-1 (DIN 2501),ANSI,AWWA and AS.
• Ebonite Hard Rubber liner for all water applications
• Hastelloy Integrated grounding and measuring electrodes
• Increased low flow accuracy for water leak detection,due to
coned liner design. ,r;
• Drinking water approvals • 1 _
• Suitable for direct burial and constant flooding
• Build-in length according to ISO 13359
• Easy commissioning,SENSORPROM unit automatically up-loads
calibration values and settings „`
• Designed that patented in-situ verification can be conducted.
Using SENSORPROM fingerprint.
Application
The main applications of the MAGFLO electromagnetic flow sensors -
can be found in the following fields:
• Water abstraction
• Water treatment
• Water distribution network(leak detection management)
• Custody transfer water meters 'w,
• Irrigation
• Waste water treatment
• Filtration plant(e.g.reverse osmosis and ultra filtration
• Industrial Water applications •
Mode of operation
The flow measuring principle is based on Faradays law of
electromagnetic Induction were the sensor converts the flow into an
electrical voltage proportional to the velocity of the flow.
Function
• Highly resistant to a wide range of chemicals
— OIML R49 and PTB approved
—Conforms to ISO 4064 and EN 14154
— MI-0001 Custody Transfer approval for billing
• Meets EEC directives:PED,97/23/EC pressure directive for#N
1092-1 flanges
• Simple onsite of factory upgrade to IP68/NEMA 6P of standard
sensor.
Integration
The complete flow meter consists of a flow sensor and an associated
transmitter MAGFLO MAG 5000 or MAG 6000
Local regulation may restrict the use of this product below the conditions quoted.Limiting conditions refer to standard connections only.
In the interests of development and improvement of the product,we reserve the right to change the specification. TI-8-628-US 02.11
152
MAGFLO MAG 5100W
Technical Specifications
Design Full bore sensor Coned bore sensor Full bore sensor
Nominal size DN 25...40(1" ...1 1/2") DN 50...300(2" ...12") DN 350...1200(14"...48")
Measuring principle Electromagnetic induction
Excitation frequency 12.5 Hz •50...65mm(2" ...2'h"):12.5 Hz DN 350...450(14" ...18"):3.125Hz
•80 ...150mm(3" ...6"):6.25 Hz DN 500... 1200(20" ...48"):1.5625 Hz
•200...300mm(8" ...12"):3.125 Hz
Process connection
Flanges
•ANSI B 16.5 Class 150 lb Class 150 lb-20 bar(290 psi)
•AWWA C-207 - - 28" ...48":Class D
•
Rated Operation Conditions
Ambient temperature
•Sensor -40...+70°C(-40...+158°F)
•With Compact transmitter -20...+50°C(-4...+122°F)
MAG 5000/6000
Operating pressure 0.01 ...40bar(0.15...580 psi) 0.03...20 bar(0.44...290psi) 0.01...16 bar(0.15...232psi)
Enclosure rating
•Standard IP67 to EN 60529/NEMA 4x/6(1 mH2O for 30 minutes)
•Optiion IP68 to EN 60529/NEMA 6P(40 mH2O continously)
Pressure drop at 3 m/s(10 fUs) As straight pipe Max.25 mbar(0.36 psi) As straight pipe
Medium conditions
Temperature of medium
•Ebonite -10...+70°C{14...+158°F)
EMC 89/336 EEC
Design
Weight See dimensional drawings
Material
•Housing and flanges Carbon steel,St 37.2
•Terminal box Standard Fibre glass reinforced polyamide
•Measuring pipe AISI 304(1.4301)
•Liner Ebonite Hard Rubber(hydro carbon resistent)
•Electrodes Hastelloy C276
•Grounding electrodes standard Hastelloy C276
Certificates and approvals
Custody Transfer(only together OIML R 49 cold water(2"...12")
with MAG 5000/6000 CT) MI 001 cold water(2"...12")
Approvals FM Class 1,Div 2
CSA Class 1,Div 2
Approvals CRN
Spirax Sarco Inc.•2150 Miller Drive•Longmont,CO 80501•Telephone:(303)682-7060•Fax:(303)682-7069 TI-8-628-US 02.11
153
MAGFLO MAG 5100W
II I( II I)
II II II II
Iiii M20(W NPT) I I M20(1/2 NPT)
Eli 1" - 11/2" _�I'I
14" 48" -- 2" - 12"
/ r
i - - -
L L
Nominal Size A L Weight
Class 150/ Class 150/
AWWA AWWA
[mm] [inch] [inch] [inch] [Ibs]
25 1 7.4 7.9 9
40 11/2 7.8 7.9 13
50 2 7.4 7.9 20
65 21/2 7.6 7.9 24
80 3 7.9 7.9 28
100 4 8.1 9.8 41
125 5 8.5 9.8 52
150 6 9.1 11.8 64
200 8 10.1 13.8 124
250 10 11.2 17.7 174
300 12 12.2 19.7 243
350 14 15.0 21.7 307
400 16 16.0 23.6 351
450 18 17.2 23.6 400
500 20 18.2 23.6 495
600 24 20.2 23.6 704
700 28 22.2 27.6 602
750 30 23.3 29.5 725
800 32 24.3 31.5 804
900 36 26.1 35.4 1089
1000 40 28.1 39.4 1282
42 28.1 39.4 1512
44 30.1 43.3 1680
1200 48 32.3 47.2 1896
Spirax Sarco Inc.•2150 Miller Drive•Longmont,CO 80501 •Telephone:(303)682-7060•Fax:(303)682-7069 TI-8-628-US 02.11
154
MAGFLO MAG 5100W
Model Code MAG 5100 W
DESCRIPTION SIZE (IN.) CODE No FLANGE
Sensor MAG 5100 W-Hard Rubber Liner(ebonite)
Liner:Ebonite 1" 7ME6580-2DJ14-2AA2 150#ANSI
Accuracy:0.5%of rate 1 1 " 7ME6580-2RJ14-2AA2 150#ANSI
Electrodes:Hastelloy C 2" 7ME6580-2YJ14-2AA2 150#ANSI
Enclosure:NEMA 4X,NEMA 6* 2 1/2" 7ME6580-2FJ14-2AA2 150#ANSI
(3-ft.submersible up to 72 hours) 3" 7ME6580-3MJ14-2AA2 150#ANSI
Flange Material:Carbon Steel 4" 7ME6580-3TJ14-2AA2 150#ANSI
Sizes 1"to 24":ANSI 16.5B,Class 150 5" 7ME6580-4BJ14-2AA2 150#ANSI
Sizes 28"to 48":AWWA C-207,Class D 6" ' 7ME6580-4HJ14-2AA2 150#ANSI
Max Temp: 158°F(70°C) 8" 7ME6580-4PJ14-2M2 150#ANSI
*NEMA 6P when applying submersible kit part# 085U0220 10" 7ME6580-4VJ14-2AA2 150#ANSI
12" 7ME6580-5DJ14-2AA2 150#ANSI
Code numbers in Bold Type indicate items ordinarily in stock. 14" 7ME6580-5KJ14-2AA2 150#ANSI
Consult factory for confirmation. 16" 7ME6580-5RJ14-2AA2 150#ANSI
18" 7ME6580-5YJ14-2AA2 150#ANSI
20" 7ME6580-6FJ14-2M2 150#ANSI
Coned Design 24" 7ME6580-6PJ14-2AA2 150#ANSI
28" 7ME6580-6YL14-2AA2 AWWA
30" 7ME6580-7DL14-2M2 AWWA
32" 7ME6580-7HL14-2M2 AWWA
36" 7ME6580-7ML14-2AA2 AWWA
40" 7ME6580-7RL14-2M2 AWWA
42" 7ME6580-7UL14-2AA2 AWWA
44" 7ME6580-7VL14-2AA2 AWWA
48" 7ME6580-8BL14-2AA2 AWWA
Spirax Sarco Inc.•2150 Miller Drive•Longmont,CO 80501 •Telephone:(303)682-7060•Fax:(303)682-7069 TI-8-628-US 02.11