2017-30020 ResolutionRESOLUTION NO 2017 -30020 A RESOLUTION OF THE MAYOR AND CITY COMMISSION OF THE CITY OF MIAMI BEACH, FLORIDA, APPROVING AND AUTHORIZING THE CITY MANAGER TO NEGOTIATE AND EXECUTE AMENDMENT NO. 1 TO THE DESIGN /BUILD AGREEMENT BETWEEN THE CITY OF MIAMI BEACH, FLORIDA, AND RIC -MAN CONSTRUCTION, INC., FOR THE PURCHASE AND INSTALLATION OF A PERMANENT EMERGENCY GENERATOR FOR THE STORMWATER PUMP STATION ON 19TH STREET BETWEEN CONVENTION CENTER DRIVE AND MERIDIAN AVENUE PROJECT; FOR A NOT -TO- EXCEED AMOUNT OF $720,000, PLUS OWNER'S CONTINGENCY IN THE AMOUNT OF $40,000 FOR A TOTAL OF $760,000; AND AUTHORIZATION OF THIS AMENDMENT NO. 1 BEING SUBJECT TO FINAL FUNDING APPROPRIATION PURSUANT TO THE CITY COMMISSION'S ADOPTION OF THE FY17/18 CAPITAL BUDGET. WHEREAS, on January 17, 2017 the City entered into a Design /Build Agreement with Ric- Man Construction, Inc. (Ric - Man), to develop, design, and construct the Stormwater Pump Station on 19th Street between Convention Center Drive and Meridian Avenue; and WHEREAS, in April 2017, the Public Works Department identified the need to incorporate a permanent emergency generator for this pump station in the event of a power failure during a storm event in the neighborhood; and WHEREAS, Ric -Man was requested to add, as part of its Design /Build services, the design, purchase, and installation of a permanent emergency generator and to be placed at the southwest quadrant of the City's Botanical Garden; and WHEREAS, the Executive Director of the Botanical Garden is in agreement with the proposed location of the generator; and WHEREAS, on August 31, 2017, Ric -Man submitted a proposal in the amount of $719.978, for a permanent power generator that operates all four pumps for a period of forty -eight (48) consecutive hours at capacity; and WHEREAS, the proposed pump station is designed to include four (4) 20,000 gpm pumps to operate at design capacity of two pumps at a time; and WHEREAS, the Public Works Department recommends operating at the pump's full capacity; and WHEREAS, Ric -Man has also submitted a proposal in the amount of $674,978 for a second permanent power generator option that operates two pumps for a period of 48 consecutive hours at capacity; and WHEREAS, the City Manager recommends approval of this Amendment No. 1, to the Design /Build Agreement with Ric -Man. NOW, THEREFORE, BE IT DULY RESOLVED BY THE MAYOR AND CITY COMMISSION OF THE CITY OF MIAMI BEACH, FLORIDA, that the Mayor and City Commission approve and authorize the City Manager to negotiate and execute Amendment No. 1 to the Design /Build Agreement between the City of Miami Beach, Florida, and Ric -Man Construction, Inc., for the purchase and installation of a permanent emergency generator for the stormwater pump station on 19th Street between Convention Center Drive and Meridian Avenue Project; for a not -to- exceed amount of $720,000, plus owner's contingency in the amount of $40,000 for a total of $760,000; and authorization of this Amendment No. 1 being subject to final funding appropriation pursuant to the City Commission's adoption of the FY17/18 Capital Budget. PASSED and ADOPTED this (N- day of Cepiv41 be/ , 2017 I RAF L E. RANADO PHILIP APPROVED AS TO FORM & LANGUAGE & FOR EXECU ION, l City Attorney Date M BEACH Resolutions - R7 P COMMISSION MEMORANDUM TO: Honorable Mayor and Members of the City Commission FROM: Jimmy L. Morales, City Manager DATE: September 13, 2017 SUBJECT: A RESOLUTION OF THE MAYOR AND CITY COMMISSION OF THE CITY OF MIAMI BEACH, FLORIDA, APPROVING AND AUTHORIZING THE CITY MANAGER TO NEGOTIATE AND EXECUTE AMENDMENT NO. 1 TO THE DESIGN /BUILD AGREEMENT BETWEEN THE CITY OF MIAMI BEACH, FLORIDA, AND RIC -MAN CONSTRUCTION, INC., FOR THE PURCHASE AND INSTALLATION OF A PERMANENT EMERGENCY GENERATOR FOR THE STORMWATER PUMP STATION ON 19TH STREET BETWEEN CONVENTION CENTER DRIVE AND MERIDIAN AVENUE PROJECT; FOR A NOT -TO- EXCEED AMOUNT OF $720,000, PLUS OWNER'S CONTINGENCY IN THE AMOUNT OF $40,000 FORA TOTAL OF $760,000; FUNDING SUBJECT TO THE ADOPTION OF THE FY17/18 CAPITAL BUDGET. RECOMMENDATION The Administration recommends adopting the Resolution. ANALYSIS On January 17, 2017 the City entered into a Design /Build Agreement with Ric -Man Construction, Inc. (Ric -Man), to develop, design, and construct the Stormwater Pump Station on 19th Street between Convention Center Drive and Meridian Avenue. In April 2017, the Public Works Department identified the need to incorporate a permanent emergency generator for this pump station in the event of a power failure during a storm event in the neighborhood. The proposed pump station is designed to include four (4) 20,000 gpm pumps to operate at design capacity of two pumps at a time. The Public Works Department recommends operating at the pump's full capacity. As such, Ric -Man was requested to add, as part of its Design /Build services, the design, purchase, and installation of a permanent emergency generator. It is anticipated that the generator is to be placed at the southwest quadrant of the City's Botanical Garden. The Executive Director of the Botanical Garden is in agreement with the proposed location of the generator. On August 31, 2017, Ric -Man submitted a proposal in the amount of $719.978, for a permanent power generator that operates all four pumps for a period of forty -eight (48) consecutive hours at capacity. Reference literature for the proposed power generator is attached as Exhibit A. Ric -Man has also submitted a proposal in the amount of $674,978 for a second permanent power generator option that operates two pumps for a period of forty- eight (48) consecutive hours at capacity. Reference literature for this generator option is attached as Exhibit B. Page 1976 of 2353 The proposal submitted by Ric-Man, for the two and four pump generators, is attached as Exhibit C. CONCLUSION The Administration is recommending that the Mayor and City Commission approve and authorize the City Manager to negotiate and execute Amendment No. 1, in the amount not-to-exceed $720'000' plus owner's contingency with Ric-Man Construction. Legislative Tracking Capital Improvement Projects ATTACHMENTS: Description D ExhibitA4 Pump Generator D Exhibit B2 Pump Generator o Exhibit Ric-Man Proposal o Resolution Page 1977 of 2353 E N C L O S U R E S Picture shown may not reflect actual package. FEATURES ROBUST/HIGHLY CORROSION RESISTANT CONSTRUCTION • Environmeritally friendly, polyester powder baked paint • Zino plated or stainless stool fasteners * Top mounted critical exhaust ai)onoing system (System shipped loose for installation at site) ~ 14 gauge steel EXCELLENT ACCESS • Large cable entry area for installation ease • Accommoclates rear mounted breaker • Double doors on both sides • Vertically hingod doors allow 180° oponing rotation • Lube oiJ and coolant drains pipes to exterior of enclosure and terminated drain valves o Radiator fill cover SECURITY AND SAFETY • Lockable access doors with standard key utilization • Cooling fan and battery charging alternator fully guarded • Fuel fill, 011 fill, coolant and battery can only bo reached via lockable access • Stub-up cover sheets for "rodent proofing" • Externally mounted emergency stop button • Designed for spreader-bar lifting to ensure safety • Control panel viewing window EXHIBIT CAT ® C15 WEATHER ��m�� ��N���N��m��� PROTECTIVE ENCLOSURES Griffin 50 Hz/60 Hz Thoso weather protective, factory installed enclosures includo critical levol silencers,* designed for safety and aesthetic value on integral fuel tank bases or on optionah fabricated stool bases. These enclosures aro of extremely ruggod construction to whthstand exposuro to the elements ofweather, *Shipped loose OPTIONS • Yellow, white, beige or ASA 61 gray paint • Interior lighting system • Skid baso with dragging and fork pockets p UL Iisted integral fuel tank w UL Iisted sub-base fuel tnk • Dual breakers (60 Hz only) (second breaker mounted right hand side) • Seismic Certification iper Applicable Building Codes: IBC 2000 IBC 2003 IBC 2006 |BC2009, CBC2O07 • Tested and Analyzed in Accordance with: ASCE7-98,A8CE7'O2,ASCB7-0S,|CC'E8AC-1G8 o Special Seismic Certification OSHPD Pre-Approval OSP-O0O4~10 • IBC certifiablo for 90 mph wind loading • Anchoring details are site specific, and are dependent on many fact n such as generator set size, weight, and concrete strength. IBC Certification requires that the anchoring system used is reviewed and approved by a Professional Engineer. Page 1978 of 2353 ENCLOSURES WEATHER PROTECTIVE ENCLOSURE OPERATING CHARACTERISTICS CIF 60 Hz WP Enc lo (Low Emissioi Ambient Capability* Airflow Rate ekW kVA or m3/s Cfm 660 500 455, 450 687.5 42 108 10.6 22,460 626.0 46 115 10.6 22,460 813 Sound Pressure Levels dBA @ Full Load 1 m 7m 15 m 97.7 97.2 87,4 86.9 81,4 80.9 Exhaust Back Pressure in/H20 kPa 12.8 12.2 3,2 3.1 568.8 43 109 10.6 22,460 96,7 86.6 80,5 11.9 3.0 562,5 49 120 10.6 22,460 96,7 86.5 80,5 11.9 3,0 410 512.6 46 116 106 22,460 96.3 86,2 80.2 11.8 2.9 400 500.0 SB 52 126 10.6 22,460 96.2 86.1 80.1 11.7 2,9 365 456.3 PP 49 120 10.0 22,460 06.0 85.9 79,9 11,7 2.1 350 437.5 SB 55 131 10.6 22,460 95,8 85.8 79.8 11.6 2.9 320 "' 400.0 ' PP 52 126 10.6 22,460 96.6 85,6 79.6 11,6 2.9 *Ambient measured with Cat® Extended Life Coolant PP SIB 50 Hz WP Enclosure (Law Emissions) Ambient Capability* kVA ekW PP/S13 'C Airflow Rate Cfm Sound Pressure Levels dBA @ Full Load lm 7m 15m 173587 :98,9 xhaust Back Pressure in/1-120 kPa 600 400 PP 43 109 8.3 17,587 98.1 88.2 82,2 9.6 2.36 455 364 PP 45 113 410 328 PP 47 117 8.3 17,587 96.8 87.4 81.4 13.8 2.19 400 320 33 53 127 8,3 ,q-114087 .; 305 292 PP .... 60 122 8.3 17,587 96.3 87.0 81.0 8.4 2.09 *Ambient measured with Cat Extended Life Coolant 4250 0614) 1600 (02.20) Approximate weight of enclosure package without silencer: 4529 kg (9,984 lb). Exact weight is dependent on options. Enclosure weight includes: sound attenuated enclosure, exhaust system, extended base and generator set. Caterpillar is pleased to offer these additional generator set enclosure colors: white, beige, and ASA 61 gray. (Caterpillar yellow is standard color.) LE)-IE7126-03 (09-11) Information contained in this publication may be considered confidential. Discretion is recommended when distributing. Materials and specifications are subject to change without notice, CAT, CATERPILLAR, their respective logos, "Caterpillar Yellow," the "Power Edge" trade dress as well as corporate and produot identity used herein, are trademarks of Caterpillar and rndigt littroddis.a33ormission. wvvw,Cat-ElectricPower.com (7 2011 Caterpillar All Rights Reserved, Printed In U.S.A. DIESEL SET CAT ® FEATURES Jmag shown may not reflect actual package. ���U����� ��x��n�w,:"o 500 ekW 625 kVA 60 Hz 1800 rpm 480 Volts Caterpiflar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cmmt^effeot|venemn. FUEL/ENISSIONGSTRATEGY • EPA Certified for Stationry Emergenoy Application (ERAT|or2emissions levels) DESIGN CRITERIA •Tho gonerator sot accepts 100% rated Ioad in one step per NFPA 110 and meets ISO 8628-5 transient response UL 2200 CSA —OptionGl "UL22OO Listed packages ^CGACertified Certain restrictions may apply. Consult with your Cat® Doaler. FULL RANGE OFATACHMENTS •Wido range of bolt-on systom expansion attachments, factory designed and tested • FIoxibia packaging options for easy and cost effective installation SINGLE-SOURCE SUPPLIER • Fully prototype tested with certified torsional vibration analysis available WORLDWIDE PRODUCT SUPPORT • Cat dealers provide extonsive post salo support including maintenance and repair agreemonts • Cat dealers hav over 1,800 dealer hranch stores operating in 200 countries •The Cat S.O.SSM program cost effectively detects internal engine component conditiori, even the presenco of iinwanted fluids and combustion by-products CAT C15 ATAAC DIESEL ENGINE , Utilizes ACERTrmleuhno[ogy • Reliable, rugged, durable design • Field-proven in thousands of applications worldwide ^ Fnupetroko'oyo|e diesel engine combines consistent perforrnance and excallont fuel economy with mini mini- mum weight • Electronic controlled governor CAT GENERATOR • Matched to the performance and output characteristics of Cat engines o UL144GReoogn[zmdC1mamHinau/at/nn ~ CSACertified CAT EMCP 4 CONTROL PANELS • Simple user friendly interface and navigation • Scalable system to moot a wide rango of customor needs • Integrated Control System and Communications Gateway ° Integrated Voltage Regulation SEISMIC CERTIFICATION • Seismic Certification available *Anchoring details are site specific, and are depen- dontonmenyfaoto,sauohaugenenatoroety|ze, weight, end concrete strength. IBC Certification requires that the anchoring system used Is reviowed and approved by a Professional Engineer • Seismic Certification per Applicable Building Codes: IBC 200O, IBC 2O08, IBC 2OO6, IBC 2OOS, IBC 2U12, C8C2007,CBC2O1O Page 1980 of 2353 E N C L O S U R E S Pkturo shown my not reflect actual package. FEATURES ROBDST/H|GH[YCORROSION RESISTANT CONSTRUCTION • Approved for usa with UL 2200 Iisted generator set packages • Environmentally friendly, polyester powder baked paint • 14 gauge steel • Zinc plated or stainless steel fasteners • Internally mounted super critical exhaust silencing system • Factory installed EXCELLENT ACCESS • Large cabe entry area for installation ease • Accommodates optional rearrnounted breaker • Double doors on both sidos • Vertca!Iy hinged doors allow 180° opening rotation • Lube oil and coolant drains pipos to exterior of ericlosure and terminated with dram vaives • Radiator fill cover SECURITY AND SAFETY • Lockabia access doors with standard key utilization • Cooling fan and battory charging alterriator fully guarded • FueI fill, oll fill, coolant and battery can only bo reached via Iockable access • Stub-up cover sheots for 'rodent proofing" • Externally mounted emergency stop button • insulation has UL84'HRflame rating • Designed for spreader-bar lftlng to onsuro satety • Control panel viewing window EXHIBIT [] �-��/ //��| | �� CAT ® C9 U���0N���� ���� ������N��� ATTENUATED ENCLOSURES Those sound attenuated, factory installod enclosures incorporate internally mounted super critical level silencers, designed for safety and aesthetic value on fabricated ste& skid bases. Optional UL Iisted tanks are avaiablo. These onclosures are of extremely ruggod construction to withstand exposure to the elements of weather, and provides weather protection. OPTIONS • YoJIow or white paint • nterior lighting system • Skid base with dragging points • UL listed integral fuel tank • UL listed sub-base fuel tank • Dual breakers (second breaker mounted right hand sido) • Seismic Certification per Applicable Building Codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007 • Tosted and Analyzed in Accordance with: ASCE 7-98, ASCE 7-02, ASCE 7-05, ICC-ES AC-156 • Special Seismic Certification OSHPO Pre-Approval OGP-0084-10 • IBC certifiable for 90 mph wind loading p Anchoring dotails aro site speclfic, and are dependont on many factors such as generator set size, weight, and concrete strength. IBC Certification requires that the anchoring systom used is reviewed and approvod by a Professional Engineer, Page 1981 of 2353 ENCLOSURES ENCLOSURE OPERATING CHARACTERISTICS CAT 60 Hz Certified SA Enclosure ekW kVA PP /SB Ambient Capability"" °C Airflow Rate °F m' /s CFM Sound Pressure Levels dBA @ Full Load 3.3 ft 23.0 ft 49.2 ft Exhaust Back Pressure in /H20 kPa 300 375" SB 45 113.0 6.0 12,636 83.3 72.0- 66.0 9,; 2.46 275 344 PP 43 109.4 12,636 83.0 71,4 65.4 9.7 2.42 250 313 SB 51: 124.0 6.0 12;636 82.7 71:01 65.0 9:4 2:33 225 282 PP 49 6.0 12,636 82,4 70,5 64.5 8.8 2.20 200 250: SB 51 s. 24:0 60 12,636 . 82.2 64.2 9.4 2,33 180 225 PP 49 120.0 6,0 12,636 82.2 70.2 64.2 8.8 2.20 *Ambient measured with Cat® Extended Life Coolant 1710.1 [07,331 1000.0 [62,99) 10000)6 .99] 4206.0 [169.661 Approximate weight of enclosure package: 3380 kg (7,452 lb)* Enclosure weight includes: Sound Attenuated enclosure, exhaust system and extended base. *'Dependant on options. Generator set enclosure also available in white. (Caterpillar yellow is standard color.) LEHE5419 -09 (03 -12) Information contained in this publication may be considered confidential. Discretion Is recommender) when, distributing. Materials and specifications are subject to change without notice, CAT, CATERPILLAR, their respective logos, "Caterpillar Yellow," the "Power Edge" trade dress as well as corporate and product identity used herein, are trademarks of Caterpillar and r p dot tirot832doifts,u3sermIssion. www,Cet- EIectr[cPower.com © 2012 Caterpillar All Flights Reserved, Printed in U.S.A. DIESEL GENERATOR SET CST" Image shown may not reflect actual package, FEATURES PRIME 275 ekW 344 kVA 60 Hz 1800 rpm 480 Volts Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost - effectiveness. FUEL /EMISSIONS STRATEGY • EPA Certified for Stationary Emergency Application (EPA Tier 3 emissions levels) DESIGN CRITERIA • The generator set accepts 100% rated load in one step per NFPA 110 and meets ISO 8528 -5 transient response. UL 2200 / CSA - Optional • UL 2200 listed packages • CSA Certified Certain restrictions may apply. Consult with your Cat® Dealer. FULL RANGE OF ATTACHMENTS • Wide range of bolt -on system expansion attachments, factory designed and tested • Flexible packaging options for easy and cost effective installation SINGLE - SOURCE SUPPLIER • Fully prototype tested with certified torsional vibration analysis available WORLDWIDE PRODUCT SUPPORT • Cat dealers provide extensive post sale support including maintenance and repair agreements • Cat dealers have over 1,800 dealer branch stores operating in 200 countries • The Cat® S•O•SS" program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion byproducts CAT C9 ATAAC DIESEL ENGINE • Utilizes ACERTTM Technology • Reliable, rugged, durable design • Field - proven in thousands of applications worldwide • Four- stroke diesel engine combines consistent performance and excellent fuel economy with minimum weight • ADEMTMA4 electronic engine control CAT GENERATOR • Matched to the performance and output characteristics of Cat engines • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time • UL 1446 Recognized Class H insulation CAT EMCP 4 CONTROL PANELS • Simple user friendly interface and navigation • Scalable system to meet a wide range of customer needs • Integrated Control System and Communications Gateway SEISMIC CERTIFICATION • Seismic Certification available • Anchoring details are site specific, and are dependent on many factors such as generator set size, weight, and concrete strength. IBC Certification requires that the anchoring system used is reviewed and approved by a Professional Engineer • Seismic Certification per Applicable Building Codes:113C 2000, IBC 2003,1130 2006, IBC 2009, CBC 2007 • Pre - approved by OSHPD and carries an OSP- 0084 -10 for use in healthcare projects in Page 1983 of2ti nia • 1NG. 00118ri 1}10. Ata..2LF/Eti. August 31, 2017 Ms, Sabrina Baglieri Senior Capital Projects Coordinator Capital Improvements Department City of Miami Beach 1700 Convention Center Drive Miami Beach, Florida 33139 Ms. Baglieri, EXHIBIT C RIC-IvIAN CONSTRUCTION FL, INC, S\ 1:'," Sitco ad), (Mit( Per the City's request, here are estimated GPM costs for furnishing and installing an emergency generator in the southwest corner of the Miami Beach Botanical Gardens property, These estimates.is very specific to the site conditions, such as the placement of the generator in a highly sensitive environmental area (Botanical Garden), a significantly longer than standard distance from the electrical panel being fed by the generator, restricted access to the work area, and installation :methods to bridge buried sensitive telecommunication lines, The estimate cost of the 2-pump/48hrs. Caterpillar Generator includes furnishing and installing: C9- CAT Generator/Sound Enclosure/Fuel Tank Conduits/Conduits/Conductors and ATS Elevated Generator Platform and Handrail Garden area Restoration Roadway Area trench restoration Engineering Inspection, asbuilts, and certification, Lump Sum Estimate is $ 674,978.00. RNIC recommends a 10% owner's contingei y, The estimated additional cost of a 4-pump/48hrs. generator including all other items listed above is $45,000.00 (C15-CAT (Jenerator). Please let inc know if you have any questions on .these estimates. Thank you, Albert: Dominguez, PE, CGC Senior Project Manager ww w,in an cini compani es, com CC: Michael Fischer, RMCF Page 1984 of 2353 RESOLUTION NO. A RESOLUTION OF THE MAYOR AND CITY COMMISSION OF THE CITY OF MIAMI BEACH, FLORIDA, APPROVING AND AUTHORIZING THE CITY MANAGER TO NEGOTIATE AND EXECUTE AMENDMENT NO. 1 TO THE DESIGN /BUILD AGREEMENT BETWEEN THE CITY OF MIAMI BEACH, FLORIDA, AND RIC -MAN CONSTRUCTION, INC., FOR THE PURCHASE AND INSTALLATION OF A PERMANENT EMERGENCY GENERATOR FOR THE STORMWATER PUMP STATION ON 19TH STREET BETWEEN CONVENTION CENTER DRIVE AND MERIDIAN AVENUE PROJECT; FOR A NOT -TO- EXCEED AMOUNT OF $720,000, PLUS OWNER'S CONTINGENCY IN THE AMOUNT OF $40,000 FOR A TOTAL OF $760,000; FUNDING SUBJECT TO THE ADOPTION OF THE FY17/18 CAPITAL BUDGET. WHEREAS, on January 17, 2017 the City entered into a Design /Build Agreement with Ric -Man Construction, Inc. (Ric -Man), to develop, design, and construct the Stormwater Pump Station on 19th Street between Convention Center Drive and Meridian Avenue; and WHEREAS, in April 2017, the Public Works Department identified the need to incorporate a permanent emergency generator for this pump station in the event of a power failure during a storm event in the neighborhood; and WHEREAS, Ric -Man was requested to add, as part of its Design /Build services, the design, purchase, and installation of a permanent emergency generator and to be placed at the southwest quadrant of the City's Botanical Garden; and WHEREAS, the Executive Director of the Botanical Garden is in agreement with the proposed location of the generator; and WHEREAS, on August 31, 2017, Ric -Man submitted a proposal in the amount of $719.978, for a permanent power generator that operates all four pumps for a period of forty - eight (48) consecutive hours at capacity; and WHEREAS, the proposed pump station is designed to include four (4) 20,000 gpm pumps to operate at design capacity of two pumps at a time; and WHEREAS, the Public Works Department recommends operating at the pump's full capacity; and WHEREAS, Ric -Man has also submitted a proposal in the amount of $674,978 for a second permanent power generator option that operates two pumps for a period of forty - eight (48) consecutive hours at capacity. NOW, THEREFORE, BE IT DULY RESOLVED BY THE MAYOR AND CITY COMMISSION OF THE CITY OF MIAMI BEACH, FLORIDA, that the Mayor and City Commission approve and authorize the City Manager to negotiate and execute Amendment No. 1 to the Design /Build Agreement between the City of Miami Beach, Florida, and Ric -Man Construction, Inc., for the purchase and installation of a permanent emergency generator for the stormwater pump station on 19th Street between Convention Center Drive and Meridian Avenue Project; for a not -to- exceed amount of $720,000, plus owner's contingency in the amount of $40,000 for a total of $760,000; funding subject to the adoption of the FY17/18 Capital Budget. Page 1985 of 2353 PASSED and ADOPTED this day of , 2017. PHILIP LEVINE, MAYOR ATTEST: RAFAEL E. GRANADO, CITY CLERK Page 1986 of 2353