Loading...
Resolution 2019-30674 RESOLUTION NO _ 2019-30674 A RESOLUTION OF THE MAYOR AND,CITY COMMISSION OF THE CITY OF MIAMI BEACH, FLORIDA, ACCEPTING, THE WRITTEN RECOMMENDATION OF THE CITY MANAGER (AS SET FORTH IN THE CITY COMMISSION MEMORANDUM ACCOMPANYING THIS RESOLUTION) AND WAIVING, BY A 517THS VOTE, THE FORMAL COMPETITIVE BIDDING REQUIREMENT, FINDING SUCH WAIVER TO BE IN THE CITY'S BEST INTEREST, AND APPROVING;AND AUTHORIZING THE CITY MANAGER TO EXECUTE A WORK ORDER WITH SOLARES ELECTRICAL SERVICES, INC., IN THE NOT TO EXCEED AMOUNT OF ;$248,000,00, FOR THE PURPOSE OF COMPLETING THE PROPERTY MANAGEMENT EMERGENCY GENERATOR AND TRANSFER SWITCH PROJECT, WHICH INCLUDES NON-PRE- PRICED ITEMS IN THE AMOUNT OF $138,277.41, PURSUANT TO THE COMPETITIVELY BID SOURCEWELL COOPERATIVE CONTRACTFOR CONSTRUCTION SERVICES(FORMERLY KNOWN AS NATIONAL JOINT POWERS ALLIANCE (NJPA)),WITH PREVIOUSLY APPROPRIATED FUNDING. WHEREAS, the City needs to install one (1) emergency generator at the Property Management Department(the Project) and WHEREAS the projectconsists of one.(1) 500KW generator, which are available via the competitively procured National Joint Powers Alliance (NJPA) 120617-KOH award to Solares Electrical Services; Inc., as well as a number of ancillary.items (e.g.,automatic transfer switch); and WHEREAS, to expedite the project, which is crucial to keep Property Management operational in the event of.a storm or other catastrophe that results in loss of power to the facility, the Administration is requesting to issue a work Order to Solares Electrical Services, Inc.,pursuant to the competively bid Sourcewell, formerly known as National Joint Powers Alliance (NJPA), cooperative contract for construction services; and. WHEREAS, Job Order Contracting (JOC) is a contracting methodology that enables facility owners to expedite and accomplish a large number of repairs, maintenance and constructionprojects with a single, competitively bid contract with pre-established pricing for most construction activities; and WHEREAS, prior to October-2012, the City acquired construction services for most small or emergency construction projects through a Job Order Contracting process;.however, since the Fall of 2012,the City had not utilized the JOC methodology and had no similar system in place for expediting construction and maintenance projects,which significantly impacts the City's ability to complete work in a timely manner; and WHEREAS,the Finance and Citywide Projects Committee(the Committee), on February 21, 2014, endorsed a recommendation by the Administration, as a pilot to reintroduce this efficient process of project delivery to.the City, to begin utilizing the Gordian Group's indefinite quantity contract (IQC), alternatively known as JOC,for construction services to expedite the delivery of construction or maintenance projects under$250,000,or for emergency projects, as approved by the City Manager; and WHEREAS, the National Joint Powers Alliance (NJPA), now known as Sourcewell, a national cooperative that bids contracts aggregating the spend volume-of agencies across the country; awarded Contract No. 071415-GGI for IQC construction services, and said contract includes an award to Solares Electrical Services, Inc:, through the Gordian.Group's IQC process, to provide services pursuant to the contract; and WHEREAS, on January 15, 2014, via Resolution No 2014-28462, the City Commission authorized the Administration to utilize cooperative awards by Sourcewell, pursuant to Section 2- 369 of the Miami Beach City Code; and WHEREAS, on April 23, 2015, the City Commission authorized the Administration, for projects up to$250,000, or emergency awards exceeding $250,000, to be acquired through the Gordian Indefinite Quantity Contract(IQC) process as a means of expediting small or emergency projects with the approval of the City Manager; and WHEREAS, the IQC process, which is used extensively by local, state and federal governmental agencies throughout the United States, expedites the delivery of construction projects and the City, as a governmental agency, is authorized to utilize the IQC process for construction services competitively awarded by the National Joint Powers Alliance (NJPA)to the Gordian Group, the Managers of IQC; and. WHEREAS,the Gordian Group, in the IQC process, established a fixed price Construction Task Catalog (Catalog)fora wide range of construction activities; and • WHEREAS, in the interest of time, the City has chosen to expedite this project and utilize the Indefinite Quantity Contract(IQC)-process; and WHEREAS, through the NJPA process, Solares Electrical Services, Inc., was identified as the contractor that has the qualifications and experience in performing the identified scope; and WHEREAS, on November 6, 2018, after negotiations, the Contractor submitted a bid proposal in the amount of$248,000.00, for the Project, including a project contingency; and WHEREAS, the original scope of work included to provide automatic transfer switch and generator including all conduit and wiring, excavation, surfacing repairs, testing, permits, and concrete slab as depicted in the approved construction documents; and WHEREAS, the purchase of one (1) 500KW Kohler generator and automatic transfer switch, which are Non-Pre-Priced(NPP) items in the Catalog; and WHEREAS, through its cooperative contract with Contract No. 071415-GGI for IQC construction services, which contract includes an award to Solares Electrical Services, Inc., through the Gordian Group's IQC process, the City has the ability to contract directly wit Solares to provide services to the City pursuant to the contract; and WHEREAS, Solares Electrical Services, Inc. is a certified contractor for the purchase and installation of 500KW Kohler generators, switchgears and ancillary items; and WHEREAS, Kohler generators arepreferred, as this brand of generator is in service at a majority of the City's facilities; and. WHEREAS, the IQC proposal received,is under the $250,000 threshold limit approved by the City Commission for projects through the NJPA IQC process; however, since the value of the non-pre-priced items exceeds the $50,000 authority of the City Manager, the approval,of the City Commission is required,to award the Project through the IQC process; and WHEREAS,the Administration recommends, as being in the City's best interest, to award the Project to Solares Electrical Services, Inc., through the 1QC process, in the not to exceed amount of$248,000.00, including the Nap-Pre-Priced items in the amount of$138,277.41. NOW, THEREFORE, BE IT DULY RESOLVED BY THE MAYOR AND CITY COMMISSION OF THE CITY OF MIAMI BEACH, FLORIDA that the Mayor and.City Commission hereby accept the written recommendation of the City Manager and waive, by a 5/7ths vote; the formal competitive bidding requirement, finding such waiver to be in the City's best interest, approve and authorize the City Manager to execute a work order with Solares Electrical Services, Inc., in the not to exceed amount of $248,000.00 for the purpose of completing the Property Management Department Emergency Generator and transfer switch project,which includes non- pre-priced items in the amount of $1384277.41, pursuant to the competitively bid Sourcewell cooperative contract for construction services formerly known as National Joint Powers Alliance (NJPA), with previously appropriated funding:. �I PASSED and ADOPTED this f� day of Ja /___I______ _,..2019. DAN GELBER, MAYOR I ATTEST: 7v/ I (3111),/ . RAFAEL E. GRANADO, CI CLERK, """le APPROVED AS TO •.�t'�\ F-4-4, FORM FORM&LANGUAGE 7? t,N '. "'o-i��44 4 FOR EXECUTION f,:-/ z\‘`:',.••• ‘\'‘\eil , � ,�- IiRJ- i (-\-,,'4' ':1NN1OORr ORATED City Attorney 0.1,47 Date • 'g: A.,/'I 1 '11` \17 ='' Resolutions -C7 L MIAMI BEACH COMMISSION MEMORANDUM TO: Honorable Mayor and Members of the City Commission FROM: Jimmy L. Morales, City Manager DATE: January 16, 2019 SUBJECT:A RESOLUTION OF THE MAYOR AND CITY COMMISSION OF THE CITY OF MIAMI BEACH, FLORIDA, APPROVING AND AUTHORIZING THE CITY MANAGER TO EXECUTE A WORK ORDER WITH SOLARES ELECTRICAL SERVICES, INC., IN THE NOT TO EXCEED AMOUNT OF $248,000.00, FOR THE PURPOSE OF COMPLETING THE PROPERTY MANAGEMENT EMERGENCY GENERATOR AND TRANSFER SWITCH PROJECT, WHICH INCLUDES THE NON-PRE-PRICED ITEMS IN THE AMOUNT OF $138,277.41, UTILIZING THE COMPETITIVELY BID SOURCEWELL, FORMERLY KNOWN AS NATIONAL JOINT POWERS ALLIANCE (NJPA), COOPERATIVE CONTRACT, WITH PREVIOUSLY APPROPRIATED FUNDI NG. RECOMMENDATION The Administration recommends adopting the Resolution. ANALYSIS The City needs to install one (1) emergency generator at the Property Management Department (the Project). The Project consists of a 500kW generator as per specifications noted in the permit drawings by TLC Engineering, the engineer of record for the Project. The installation of this equipment is essential to keep the Property Management facility operational in the event of a storm or other catastrophe that would result in loss of power. Accordingly, the Property Management Department (the Department) issued Invitation to Quote (ITQ) ITQ-2019-018-MT pursuant to Section 3.2 of City of Miami Beach contract ITB 2018-039 (the Agreement) to Furnish, Installation, Maintenance and Repair of Generators Citywide. Consequently, a quote was requested from R & D Electric Inc. and All Power Generators, the awarded vendors under this Agreement.All Power did not respond. R & D Electric provided a lump sum proposal in the amount of$286,442.00. On February 21, 2014 the Finance and Citywide Projects Committee (the Committee) endorsed a recommendation by the Administration to reintroduce this efficient process of project delivery to the City, to begin utilizing the Gordian Group's indefinite quantity contract (IQC), alternatively known as JOC, for construction services to expedite the delivery of construction or maintenance projects under Page 752 of 1648 $250,000, or for emergency projects, as approved by the City Manager. Sourcewell, formally known as National Joint Powers Alliance (NJ PA), a national cooperative that bids contracts aggregating the spend volume of agencies across the country, has awarded Contract No. #071415-GGI for IQC construction services to the Gordian Group. The NJPA contract with the Gordian Group includes a number of contractors prequalified to provide services to the City pursuant to the contract under an IQC pre-priced methodology. The contract also has a provision for non-pre-priced items which requires the contractor to secure three quotes for every item that does not correspond to a pre-priced contract line item. In efforts to expedite the installation of the generator and transfer switch at the Property Management Department, the above referenced project has been selected as a project appropriate for acquiring construction services through the Gordian IQC process. Details of the scope of work of the project are included in the attached proposal from Solares Electrical Services, Inc., a prequalified vendor providing construction services to the City pursuant to Gordian Group's IQC contract awarded by NJ PA. A proposal from Solares Electrical Services, Inc., in the amount of $248,000.00 with a contingency included for the installation of one (1) 500 kW generator and transfer switch, which includes the non-pre-priced items in the amount of$138,277.41. CONCLUSION The Administration recommends adopting the Resolution. Legislative Tracking Property Management ATTACHMENTS: Description ❑ Resolution ❑ IQC-Proposal Page 753 of 1648 _ „, Work Order Signature Document THE GORDIAN GROUP NJPA EZIQC Contract No.: FL-MDCAE04-052014-SES X New Work Order Modify an Existing Work Order Work Order Number.: 062105.00 Work Order Date: 11/06/2018 Work Order Title: Miami Beach Property Management Office New Generator Owner Name: City of Miami Beach Contractor Name: Solares Electrical Services, Inc Contact: Adrian Morales Contact: Andres Solares Phone: 305-673-7000 Phone: Work to be Performed Work to be performed as per the Final Detailed Scope of Work Attached and as per the terms and conditions of NJPA EZIQC Contract No FL-MDCAE04-052014-SES. Brief Work Order Description: Time of Performance Estimated Start Date: Estimated Completion Date: Liquidated Damages Will apply: Will not apply: E1 Work Order Firm Fixed Price: $228,947.59 Owner Purchase Order Number: Approvals Owner Date Contractor Date • Work Order Signature Document Page 1 of 1 11/6/2018 Page 757 of 1648 AIQC THE GORDIAN GROUP Detailed Scope of Work To: Andres Solares From: Adrian Morales Solares Electrical Services, Inc City of Miami Beach 10421 NW 28th Street 1700 Convention Center Drive Miami, Fl 33172 Miami Beach, FL 33139 No Data Input 305-673-7000 Date Printed: November 06,2018 Work Order Number: 062105.00 Work Order Title: Miami Beach Property Management Office New Generator Brief Scope: nPreliminary n Revised n Final The following items detail the scope of work as discussed at the site.All requirements necessary to accomplish the items set forth below shall be considered part of this scope of work. Provide and Install new generator,ATS,conduit,wiring, concrete pad,demo etc as indicated in the electrical drawings E1.01. Subject to the terms and conditions of JOC Contract FL-MDCAE04-052014-SES. Contractor Date Owner Date Scope of Work Page 1 of 1 11/6/2018 Page 758 of 1648 Contractor's Price Proposal - Summary Date: November 06,2018 Re: IQC Master Contract#: FL-MDCAE04-052014-SES Work Order#: 062105.00 Owner PO#: Title: Miami Beach Property Management Office New Generator Contractor: Solares Electrical Services,Inc Proposal Value: $228,947.59 Section-01 $24,234.05 Section-02 $668.03 Section-03 $5,177.56 Section-22 $961.75 Section-23 $1,744.47 Section-26 $185,982.37 Section-28 $567.67 Section-32 $9,611.69 Proposal Total $228,947.59 Thisl total represents the correct total for the proposal. Any discrepancy between line totals, sub-totals and the proposal total is due to rounding. The Percentage of NPP on this Proposal: 60.40% Contractor's Price Proposal-Summary Page 1 of 1 11/6/2018 Page 759 of 1648 Contractor's Price Proposal - Detail Date: November 06,2018 Re: IQC Master Contract#: FL-MDCAE04-052014-SES Work Order#: 062105.00 Owner PO#: Title: Miami Beach Property Management Office New Generator Contractor: Solares Electrical Services,Inc Proposal Value: $228,947.59 Sect. Item Mod. UOM Description Line Total Labor Equip. Material (Excludes) Section-01 01 22 16 00 0002 EA Reimbursable FeesReimbursable fees will be paid to the contractor for the $4,929.02 actual cost,without mark-up,for which a receipt or bill is received.The Adjustment Factor applied to Reimbursable Fees will be 1.0750.The labor cost involved in obtaining all permits is in the Adjustment Factor.The base cost of the Reimbursable Fee is$1.00.The quantity used will adjust the base cost to the actual Reimbursable Fee(e.g.quantity of 125=$125.00 Reimbursable Fee).If there are multiple Reimbursable Fees,each one shall be listed separately with a comment in the"note"block to identify the Reimbursable Fees(e.g.sidewalk closure,road cut,various permits, extended warrantee,expedited shipping costs,etc.).A copy of each receipt shall be included with the Proposal. Quantity Unit Price Factor Total Installation4,427.00 x 1.00 x 1.1134 = 4,929.02 permit 2 01 22 20 00 0010 HR ElectricianTasks in the CTC include appropriate costs to cover labor.These $1,320.40 tasks will be requested specifically by the owner for miscellaneous work not covered in the CTC. Quantity Unit Price Factor Total Installation32.00 x 37.06 x 1.1134 = 1,320.40 work related to note 12 page E-1.01 3 01 22 20 00 0049 HR Investigating Senior Engineer Or Specialty ConsultantFor special investigatory $3,340.20 engineering requirements or other miscellaneous professional services. Quantity Unit Price Factor Total Installation24.00 x 125.00 x 1.1134 = 3,340.20 for permitting,testing and owners training 4 01 22 23 00 0386 WK 1/2 To 5/8 CY,65 HP,Loader-Backhoe With Standard Bucket And Full-Time $2,548.33 Operator Quantity Unit Price Factor Total Installation1.00 x 2,288.78 x 1.1134 = 2,548.33 5 01 22 23 00 0718 DAY 650 KW A/C Resistive Loadbank $1,003.46 Quantity Unit Price Factor Total Installation2 00 x 450.63 x 1.1134 1,003.46 6 01 22 23 00 0736 EA Fuel Reimbursement For GeneratorsPurchases made by the contractor for $2,226.80 fuel will be reimbursed to the Contractor at the actual cost of the purchase, without mark-up,for which a receipt or bill is received.The Adjustment Factor applied to Reimbursable Fees will be 1.0000.The base cost of the purchase is$1.00,quantity will adjust cost to actual purchase cost;i.e.,quantity of 125 =$125.00 purchase.If there are multiple purchases,each one shall be listed separately with a comment in the"note"block to identify the purchase. Quantity Unit Price . Factor Total Installation2,000.00 x 1.00 x 1.1134 = 2,226.80 7 01 22 23 00 1173 WK 3 Ton,4 x 2 Flat Bed Truck With Full-Time Truck Driver $3,103.20 Quantity Unit Price Factor Total Installation1.00 x 2,787.14 x 1.1134 = 3,103.20 Contractor's Price Proposal-Detail Page 1 of 6 11/6/2018 Page 760 of 1648 Contractor's Price Proposal - Detail Continues.. Work Order Number: 062105.00 Work Order Title: Miami Beach Property Management Office New Generator • Section-01 8 01 45 23 00 0011 EA Proctor Compaction 4"Standard Mold ASTM D698,Field Soils Test $356.98 Quantity Unit Price Factor Total Installation2 00 x 160.31 x 1.1134 356.98 9 01 71 13 00 0005 EA Up To 20 Ton Lift Move On/Off Cost,Truck Mounted Cranelncludes delivery $278.35 and pickup. Quantity Unit Price Factor Total Installation1.00 x 250.00 x 1.1134 278.35 10 01 71 13 00 0005 0047 MOD For>30 To 60 Miles Radius,Add $69.59 Quantity Unit Price Factor Total Installation1.00 x 62.50 x 1.1134 69.59 11 01 71 23 16 0005 HR 2 Person Survey Crew(Unit Of Measure Is Per Crew Hour Worked)Includes $178.58 surveyor,rodman,equipment and instruments. Quantity Unit Price Factor Total Installation1.00 x 160.39 x 1.1134 = 178.58 • 12 01 71 23 16 0023 ACR Survey Clear Area For Underground Utilities $3,633.86 Quantity Unit Price Factor Total Installation100 x 3,263.75 x 1.1134 = 3,633.86 13 01 71 36 00 0003 EA X-Ray Or Electromagnetic Survey Minimum Set-Up ChargeFor projects where $331.20 the total charges are less than the minimum set-up charge,use this task exclusively.This task should not be used in conjunction with any other tasks in this section. Quantity Unit Price Factor Total Installation100 x 297.47 x 1.1134 = 331.20 14 01 74 19 00 0016 EA 30 CY Dumpster(4 Ton)"Construction Debris"Includes delivery of dumpster, $686.95 rental cost,pick-up cost,hauling,and disposal fee.Non-hazardous material. Quantity Unit Price Factor Total Installation100 x 616.98 x 1.1134 = 686.95 15 01 74 19 00 0037 CYM Hauling On Paved Roads,Miles Over Initial 15 Miles $227.13 Quantity Unit Price Factor Total Installation600.00 x 0.34 x 1.1134 227.13 Subtotal for Section-01 $24,234.05 Section-02 16 02 41 19 13 0057 EA Saw Cut Minimum ChargeFor projects where the total saw cutting charge is $512.15 less than the minimum charge,use this task exclusively.This task should not be used in conjunction with any other tasks in this section. Quantity Unit Price Factor Total Installation100 x 459.99 x 1.1134 = 512.15 17 02 66 23 00 0065 SF Cleanup And Re-Grade Working Surface $155.88 Quantity Unit Price Factor Total Installation2,000.00 x 0.07 x 1.1134 = 155.88 Subtotal for Section-02 $668.03 Section-03 18 03 11 13 00 0026 SF Elevated Slab Wood Formwork $299.95 Quantity Unit Price Factor Total Installation60.00 x 4.49 x 1.1134 = 299.95 19 03 21 11 00 0009 TON >#6,Grade 70,Footings And Slabs,Reinforcing Steel $3,911.29 Quantity Unit Price Factor Total Installation2.00 x 1,756.46 x 1.1134 - 3,911.29 Contractor's Price Proposal-Detail Page 2 of 6 11/6/2018 Page 761 of 1648 Contractor's Price Proposal -Detail Continues.. Work Order Number: 062105.00 Work Order Title: Miami Beach Property Management Office New Generator Section-03 20 03 31 13 00 0018 CY Direct Chute,Place 3,000 PSI Concrete Continuous Footings $966.32 Quantity Unit Price Factor Total Installation10.00 x 86.79 x 1.1134 = 966.32 Subtotal for Section-03 $5,177.56 Section-22 21 22 11 16 00 0007 LF 2"Schedule 40 Threaded Galvanized Steel Pipe With 150 LB Malleable Iron $961.75 Fitting Assemblylncludes all hangers and all galvanized malleable iron fittings (couplings,elbows,tees and reducer fittings).All hangers are complete assemblies.Not for use where detail is available. Quantity Unit Price Factor Total Installation70.00 x 12.34 x 1.1134 = 961.75 Subtotal for Section-22 $961.75 Section-23 22 23 05 48 00 0021 EA 550-1,920 LB Rubber In Shear Vibration Isolation With 0.48"Deflection $1,619.28 Quantity Unit Price Factor Total Installation4.00 x 363.59 x 1.1134 = 1,619.28 23 23 09 23 00 0907 EA Break Glass Switch $125.19 Quantity Unit Price Factor Total X Installation 1.00 x 112.44 x 1.1134 = 125.19 Subtotal for Section-23 $1,744.47 Section-26 _ 24 26 00 00 00 0000 _ KOHLER Model 500REOZJ,EPA Certified Diesel Generator Set,500KW,@ 0.8 $138,277.41 PF,60 Hz,3 Phase,UL 2200,277/480 Volt Quantity Unit Price Factor Total NPP Installation 1.00 x 111,227.00 x 1.2432 = 138,277.41 25 26 05 13 00 0182 EA 500 MCM Cable Splice,To 5 KV One Conductor,Shielded Medium Voltage To $1,546.65 5 KV Quantity Unit Price Factor Total Installation8.00 x 173.64 x 1.1134 1,546.65 26 26 05 19 16 0251 MLF #6 AWG Cable-XLPE-USE-RHH-RHW 600 V Copper,Single Stranded,Placed $278.49 In Conduit Quantity Unit Price Factor Total Installation0.20 x 1,250.64 x 1.1134 278.49 27 26 05 19 16 0258 MLF #3/0 AWG Cable-XLPE-USE-RHH-RHW 600 V Copper,Single Stranded, $361.93 Placed In Conduit Quantity Unit Price Factor Total Installation0.05 x 6,501.43 x 1.1134 = 361.93 28 26 05 19 16 0284 MLF #1/0 AWG Cable-Type THHN-THWN 600 V Copper,Single Stranded,Placed $1,411.02 - In Conduit Quantity Unit Price Factor Total Installation0.41 x 3,079.20 x 1.1134 = 1,405.64 Demolition 0.02 x 241.97 x 1.1134 = 5.39 29 26 05 19 16 0293 MLF 600 MCM Cable-Type THHN-THWN 600 V Copper,Single Stranded,Placed In $23,304.24 Conduit Quantity Unit Price Factor Total Installation1.38 x 15,119.98 x 1.1134 = 23,231.73 Demolition 0.12 x 542.69 x 1.1134 = 72.51 Contractor's Price Proposal-Detail Page 3 of 6 11/6/2018 Page 762 of 1648 Contractor's Price Proposal -Detail Continues.. Work Order Number: 062105.00 Work Order Title: Miami Beach Property Management Office New Generator Section-26 30 26 05 26 00 0099 EA 5/8"Diameter x 10'Long Copper-Clad Ground Rods $253.32 Quantity Unit Price Factor Total Installation4.00 x 56.88 x 1.1134 = 253.32 31 26 05 29 00 0016 LF >2'Length x 1-5/8"Wide x 1-5/8"High,12 Gauge,Steel Unistrut Channel $665.37 Quantity Unit Price Factor Total Installation100.00 x 5.36 x 1.1134 = 596.78 Demolition 80.00 x 0.77 x 1.1134 = 68.59 32 26 05 29 00 0024 EA 4-Hole,7-1/4"Length,In-Line,Flat Splice Plate,Unistrut Channel Fitting $41.64 Quantity Unit Price Factor Total Installation10.00 x 3.74 x 1.1134 = 41.64 33 26 05 29 00 0028 EA 3-Hole,1-7/16"x 4-1/8",90 Degree Angle,Unistrut Channel Fitting $29.39 Quantity Unit Price Factor Total Installation6.00 x 4.40 x 1.1134 29.39 34 26 05 29 00 0034 EA 5-Hole,1-5/8"x 1-5/8",U-Connector,Unistrut Channel Fitting $30.66 Quantity Unit Price Factor Total Installation6.00 x 4.59 x 1.1134 = 30.66 35 26 05 29 00 0047 EA 4"Diameter,Rigid Steel Conduit Clamp For Unistrut Channel $18.26 Quantity Unit Price Factor Total Installation4.00 x 4.10 x 1.1134 = 18.26 36 26 05 29 00 0062 EA 5/8-11 Lock Nut With Spring For Unistrut Channel $117.58 Quantity Unit Price Factor Total Installation20.00 x 5.28 x 1.1134 = 117.58 37 26 05 33 13 0034 CLF 1"RGS With 4#12 THHN/THWN Wire Assemblylncludes conduit,terminations, $90.02 straps,wire as indicated.Not for use where detail is available. Quantity Unit Price Factor Total Installation0.15 x 539.01 x 1.1134 90.02 38 26 05 33 13 0922 EA 4"PVC Coated,Urethane Lined,RGS Standard Radius Elbow $1,518.12 Quantity Unit Price Factor Total Installation6.00 x 227.25 x 1.1134 = 1,518.12 39 26 05 43 00 0174 LF 2 At 4",PVC,Type DB Duct Bank $1,719.09 Quantity Unit Price Factor Total Installation160.00 x 9.65 x 1.1134 = 1,719.09 40 26 05 43 00 0188 EA 4"Adapter $202.15 Quantity Unit Price Factor Total Installation6.00 x 30.26 x 1.1134 = 202.15 41 26 05 83 00 0023 EA 1/0 AWG Compression Lugs,1 Hole,Wrapped,Low Voltage,To 600 Volts $100.38 Quantity Unit Price Factor Total Installation4.00 x 22.54 x 1.1134 = 100.38 42 26 05 83 00 0075 EA 750 MCM Compression Lugs,2 Hole,Wrapped,Low Voltage,To 600 Volts $3,744.77 Quantity Unit Price Factor Total Installation48.00 x 70.07 x 1.1134 = 3,744.77 43 26 27 13 00 0027 EA 4 Meters And Main,120/240 Volt,1,200 Amp Bus,4 Jaw Sockets,200 Amp $1,475.01 Max Quantity Unit Price Factor Total Installation1.00 x 1,324.78 x 1.1134 = 1,475.01 44 26 32 13 13 0021 EA 600 KW Diesel Generator Set,3 Phase(Cummins DQCA) $6,898.82 Quantity Unit Price Factor Total x Installation 1.00 x 6,196.17 x 1.1134 = 6,898.82 Contractor's Price Proposal-Detail Page 4 of 6 11/6/2018 Page 763 of 1648 Contractor's Price Proposal - Detail Continues.. Work Order Number: 062105.00 Work Order Title: Miami Beach Property Management Office New Generator Section-26 45 26 32 13 13 0021 0349 MOD For Weather Resistant Aluminum Diesel Generator Enclosure,Add $0.00 Quantity Unit Price Factor Total Installation0.00 x 68,478.38 x 1.1134 = 0.00 46 26 33 43 00 0004 EA Solid State Battery Charger,12 Cell Single Phase With Wall Bracket, $2,051.43 208/240/480 V Quantity Unit Price Factor Total Installation100 x 1,842.49 x 1.1134 = 2,051.43 47 26 36 23 00 0048 EA 800 Amp Automatic Transfer Switch/Service Entrance,3 Pole Circuit Breaker, $793.40 NEMA 1 Enclosure(Cummins OTPCSE800) Quantity Unit Price Factor Total X Installation 1.00 x 712.59 x 1.1134 = 793.40 48 26 36 23 00 0048 0235 MOD For NEMA 12 Enclosure,Add $1,053.22 Quantity Unit Price Factor Total Installation100 x 945.95 x 1.1134 = 1,053.22 Subtotal for Section-26 $185,982.37 Section-28 49 28 05 13 23 0003 CLF Red Teflon 2-Pair#18 Gauge,Twisted Shielded Solid CU $162.17 Quantity Unit Price Factor Total Installation1 00 x 145.65 x 1.1134 = 162.17 50 28 31 23 00 0347 EA Remote Annunciator,80 Character LCD,Common System Indicators,Beige $405.50 Housing,Mounts To 4"Box With Supplied Ring(EST3 RLCD) Quantity Unit Price Factor Total Installation1.00 x 364.20 x 1.1134 - 405.50 Subtotal for Section-28 $567.67 Section-32 51 32 11 16 00 0004 CY Bituminous Stabilized Base Course3/4"ASTM C33. $2,356.58 Quantity Unit Price Factor Total Installation24.00 x 88.19 x 1.1134 = 2,356.58 52 32 12 13 19 0001 SY Surface Prime Coat,0.28 Gallon/SY $25.12 Quantity Unit Price Factor Total Installation24.00 x 0.94 x 1.1134 25.12 53 32 12 13 19 0001 0338 MOD For Up To 150,Add $5.88 Quantity Unit Price Factor Total Installation24.00 x 0.22 x 1.1134 = 5.88 54 32 12 16 13 0005 SY 2"Thick Binder Courselncludes placement,rolling,finishing and sweeping. $5,918.83 Quantity Unit Price Factor Total Installation600.00 x 8.86 x 1.1134 = 5,918.83 55 32 12 16 13 0022 TON Base Course,PC-I $870.19 Quantity Unit Price Factor Total Installation6.00 x 130.26 x 1.1134 = 870.19 56 32 12 16 13 0022 0441 MOD For>5 To 10,Add $435.09 Quantity Unit Price Factor Total Installation6.00 x 65.13 x 1.1134 = 435.09 Subtotal for Section-32 $9,611.69 Contractor's Price Proposal-Detail Page 5 of 6 11/6/2018 Page 764 of 1648 Contractor's Price Proposal - Detail Continues.. Work Order Number: 062105.00 Work Order Title: Miami Beach Property Management Office New Generator Proposal Total $228,947.59 This total represents the correct total for the proposal. Any discrepancy between line totals, sub-totals and the proposal total is due to rounding. The Percentage of NPP on this Proposal: 60.40% Contractor's Price Proposal-Detail Page 6 of 6 11/6/2018 Page 765 of 1648 @IQc- Subcontractor Listing THE GORDIAN GROUP Date: November 06,2018 Re: IQC Master Contract#: FL-MDCAE04-052014-SES Work Order#: 062105.00 Owner PO#: Title: Miami Beach Property Management Office New Generator Contractor: Solares Electrical Services,Inc Proposal Value: $228,947.59 Name of Contractor Duties Amount % No Subcontractors have been $0.00 0.00 selected for this Work Order Subcontractor Listing Page 1 of 1 11/6/2018 Page 766 of 1648 QUOTE# TANK GAL GENSET MODEL ONSET FOOTPRINT'ASSY.WEIGHT I 33787 100 GAL 0S500 132e X 74" X LBS 1 L( SOt OF 1.41.1Ex111 170.138 OVERALL FO,1-11 IDESclarllen YIT ENGINEERING GNEeAt NLYW6y OOIiSRil1LRIGN(.OTA) 6541 rsF3RH 0SOEtuas aOUFYAct1E6rt FOR ARCHITECTURE Lagoon Dr. 6505. .FSS BOOR 5757 Suit L40Oon Dr. 6541 sE1wl.ES5 STEEL PGOA HAMMAM Suite 400 TT'— -T3— tl .. 6SM !u[p uf1eFC xV9�CAWE LOIM1EP Phone:305266.8553 4600 OCSBUB3E fYnLL vnv 7C 305.260.6695 6 O 00 T L Yx,: .vo-a°9mee,>3.com {L,! 6900 Y EU.FIlaL IMIIATO4 --. II T 1 1- r 6645 cusmm sYPP6E6 Pua e y m®nc°60°3001p°YA4m.c _ �)ITT[t,.___ir - 1�� 1360 OPG SUPPUE9 EGILAR SVAITM r- firElm,1Hw 1 .p'R50wrvawEB 11.4 BURMA - i...-..':76.7"-:._ _� •o_ 661ti SL•E-.C.R-Ofi-OY% �[FYI r 1 R r�► I - OVERALL X79 84 v[Asm a-Iv- — PAw CM:PP-55-41-48 raf r_ , ••'• •••.•'•_: � I, 8518 CRUM F0YF5/00,0610 EFR>70a .I. MALI _; Booz WPC BLOCK 05(1 17.5 0 MATO • wn AID a I_. 7 lag= 6904 Yawl er WIPE&AilM WAGE' OPEN O -.Rr 11:11.1=7,,, ,f�E�+ :61407 T COLO6TALL MA HeLas Z O , 1"w 97181 P/INT COLOR EGGSHELL MILTE W n D __ ❑ + ❑ .. tl ❑ W 1G ""�./tl / z._ .LL +420.5 —O,PEEN Q-1 U 160 LL ED.m I ; I. —84 OVERALL - W a CC 1111 IP _ 7ji�' � Il�r, EL as �� J _. „ , �r s yI,L '�I `� la t i„.�'`FI • '� �� 7 �� 103 Fh_ :H, N. Date ow�cm� `{■, Revisions .,.., '� 158.13 1'I- i.t.144,4 � ■ Al „Iy� OVERALL NI�_ 7 1'f `I� Il 146 Irl +i/ 5 u- 17 , 11')j1ttil, � ,,„_.,,:•.•.::::,:.„,„ HEIGHT v� 4..— )YL — �I: � 9 I );H. ;ISI ■Hill 1 r . o- D 171 _315 sa Manuel Yollinedo,P.E PDlfda License 463096 I I- 100- - "-70-1 IRIS'AUTOCAD DRAWING IS 1I-IE PROPERTY OF GLOBAL POWER COMPONENTS AND MAY 801 BE USED IN ANY WAY DETRIMENTAL TO THE INTERESTS.OF C.P.C.ANY MANIA CHANGES KILL VOID 140 DRAWING,SPLTIFICABO0S MAY CHbNCE WITHOUT NOTICE I ASSY REV DATE: RCHSrW0GE MADE BY REV GATE REvISIONS CHANGE MADE BY GIVE-A1-500-1100 ASSEMBLY 5 CUSTOMER/10:FLORIDA DOA. DR/651NG REF:AAA033767 Beal. 616543 w DWG X POWER COMPONENTS issue m. — DATE:5/30/17 0411.2056 _ DRAWN BY:LtTO ef. TLC wm.aeer: TLC scala SOr.,ilia STANDBY GENERATOR e DIMENSIONS P. R E-1.02 S Snout d Papa 767 W 1648 SCOPE OF WORK: 1 L(. RtT NU I ES: THE SCOPE OF NORK FOR THE PRESENT Ot ENSIIND]wN DISTRIBUTION PANEL MIN tat roRSW,S DESIGN IS TO PROVIDE STAN Ea'POWER TO REFERMAIM!BEACH-PUBLIC WORK FACILITY. 0 NewAlnOAANCTTRANSFER soma SERVCC rAMO..eov.]POLE 4130V. _ tsRn`MINA aaa NDD. THIS SHALL BE DONE BY INSTALLING A 6COLV DIESEL FUELED GENERATOR®480211V- 0NEW CONDUCTORS mutso..amoo.REFER TO THREE PHASE.PUBLIC WORK, RISER DAMAN FOR P&L \ S C-IAN LN<FENCE OGENERATORFEEDERS: CONDUIT ATTACHED TOEXTERIOR wuL' FOR ARCHITECTURE Yxt;LT \ 0 NEIN 40,NSDRRS,aCD.ATta RFCRFFFNrORISER MORAY FORME SUES sUm w0 5757 Blue L400 or. .\ 0ORO,BREAKER TO FRED UNERATOR BUILT-IN 1.0..0 CURER.PROW.PONEL Mleml,FL 33126 Phone:305.268.8553 \ OO•a ESAwmemlmsgSWe• I V 'een305288.8885 AS'HA.PEV_IVEET Fax: 0 1/WW E8 80000015 \ EXISTING Ile GENERATOR, 0,iWow-ENmvteeE CONCRETE • NC • eO9Ah1 t006 i1DFr�ONbk0b0ttiEe OBE 0.GENERATOR ENERGEACY SIIUT.OFF `\ ®EMOTE AMwNCATORPNRR. BVrtoN \ O O gym•- I snows Y 0e� III1 i 0I75Dt@ T fi • v.�.�—� ©- tory w CC O IiI I1' o ©II 11 I'�� U(Y 70 , `, BE.F/E_CT RI,I I I ETVG I • I FC 1NR II r-e SIM owed TedSwaged rvawA u nnma. cumrn. Na..rr. M. u. pod bw� mmn�w wv m= W o d ZW 'Pt EQ I CC\TRC_RCA 0 Na,c [ ER EE — CO 1 RR.FL.-4. �� 1 Al, 1 • ''��1 9 — a elm*ton renewal ;alt. to a:.1u•n+w— = a 'I 11urn Lla O II ip I cFNERaroa atm, T. ..,m,. vwt..�M '°' ... esoexera 17.1. , neareeetho•to CAC 11.41,671.1.ST1.1,I+1 I"ELECTRICAL SITE PLAN n n a >DD "No"°'D0. o wE IA'.1 0 .," miaow - i. woe._ ---- • 7. -0 -0 �E KEY NOTES: SeelManuel MBllinedo,P.E. 1 0 xDv 0 NEW POLS.SERVICE _svltc Bonar Florida license k63096 1 GENER11 OS SET REQUIRED � �.9 ®° 0 NEW SERRVICENTR�Q CONDUCTORS:0 m e . 7 I�� ®MO GROUNO BAR IN GE1.1ERATOR SET HAS BEEN s um(alAaxsinhvs iM�.l �,� II,I -0 - l® ( 0 FACTORY 0 O vcuo iLfotROamrvRCmR.I(tl RECEPTACLE MO L 10.11T11.IN GENERATOR J. J -/` ® CONCRETE NbETANtI f a' QTTERN.CC. GEN ELWDSARE FACTORY 5I]u 11CH SE1,4)100W®tTE'A'CORROURATION,HOLE AMAN.0, ING 1. ! (y ]�/- 9I ���III��� murvot�µDRIrm oosl P) ittdN G)w sus EACH SET•Tlc]ooxwnrnm•111 P,qw Na: ? SlRLICIVRAL STEEL BAR PANEL SCREECLE. y0.1 �mwsrulmsnARIN G GENERATOR �t I RLOAD W E Emro�wxusBixOUTnerw laeeoatx 618002 N. / xQw lox vweNEiro RExwx. �i]Oj�V� .u,nlyA ,y011x IS _ 03-31-08 l5 ®W iuse PrtlxNxoeBCRDu�sErnom a BT: TLC Approved Br TLC ®x,sBREAKER.TNO MIN 1 OF 1L MCA MN CIRCINI 1/8..1'-0" SE REMOVED.DISCONNECT R.IESE MALES DrewIng Ma FROM VIOP,X0REP.10VEALL. 0 FRU Val,.COORDINATE MN FP.1.19i DAA m GENERATOR DISCONNECT FROM POWER SOURCE. EMPTY III " FLOOR PLAN& o RISER DIAGRAM 3 Et a. "PARTIAL RISER DIAGRAM c Da No.: , x,= E-101 GENERAL SPECIFICATIONS: JOB aTANK Cal GENSET MODEL. GENSET FOOTPRINT TOTAL WEIGHT -CERTIFICATIONS AND STANDARDS: 5000 GAL DS1250 198.25 X 90' 48,750 LBS NEC 2014 EMISSIONS:COMPLYING WITH EPA TIER 3. • IL( ALL VERTICAL WALL& MANUFACTURED IN ISO 9001 AND ISO 381 OVERALL DD ANELSSE2'FIBER OF PART L �OF SDN mY 14001 CERTIFIED FACILITY. 169.25 102.25 - INSULATION BOARD W/ 65EI NMMLNW ONETTNAT10.N(994.1x5 ; //� PERF aMe 108 -MIXTURE REV1iO d1 UL 2200 COMPLIANT. �" _ �_ _ — _3505 60550 SPA_LIAL WE!RCM PER ELVEN0171 1 a ISO 8528-5 FOR TRANSIENT RESPONSE. ENGINEERING 1 I I 7—J _ ® L O I U •P• ° _E- - ss�io v9 558 AK fi FOR ARCHITECTURE A 001 t POWER RATING:ACCEPTS DESIGN LOAD IN 575]BIYe Lepmn Dr. _ __ II 5515 851055 mnrx�aYaE lum ONE STEP PER NEC 110. 6,1155400 Mrs 11 /' WECOL 2LFIBER I-NSUUTNIN BOND 1 Miami,FL 33128 �}e':C.. 11 On INIENRI W/NYYAUY N5 1 POWER FACTOR>0.6. PF 305 L 3312653 • �__'641 )li�.':� (r[P••�,�b.�a.r .A \,i 0509 RMI WWJt 1 Fax:305.268.8695 _ �.I{.e -- p.�.`� •'''� 68.8 651606sue 6DWMm 061 58 ROc= 2 YEAR STANDARD WARRANTY. vnvw.tleam.Gom T 68.0 TAC SUPPLIED E ID GST NT FUL I 0 10000015 11, f _ INIERULLY YWMFD 9FIYFA 1 ecoop Lai 11490.110owe...Aw 1 A.A. ELECTRIC STARTING MOTOR-24V. - T • I 5. �' 1— �'vcf�1-50-oT5N-9w CHARGING ALTERNATOR-24V. j:, f111 Vaoo*.SUMER D6LINRGf 1 112 * .. ,r.l _—_ aero 1505.FL-0FCTaw-510 t SUSTAINED SHORT CIRCUR CURRENT UP TO OPEN 1,2 � ,411110 �'� _ _ _ I`4 RAIN CAP:MEM 0 TNT-a0K 1 300%IN 10 SEC. BBOT EMU119�ExTFN90N 2 II1 •iIR `�if`-` TWA-Wulf R TM&c RT CHARGER -i- 004 DIGITAL,SOLID STATE,VOLT-PER-HERTZ iC;r1rI,F_.x ',4•-liw,�1.,-nl li',P.Y. - 800 455 trY.WE PKOCK55OM 1 _ 6esx MOW tr ran elmcx MOM_ REGULATOR. r �� Mll..�,..e1 411111 ` 5910 rrwOfscTnr MIT PACK. 1 +/-0.25 7.VOLTAGE REGULATION. =1 ®® — 6511 DKN00141 rr 0501(E(100 wAtl) I V m , 0913 0005 SYIIIQI(1=PGL) 1 0 • - 5915 cFra ouncT-120 Al,sj i COMMUNICATION TO REMOTE ANNUNCIATOR. a 0 5915 nn PROTECTED amEr 00 w t ENGINE JACKET WATER HEATER. LL ans WOK at ORE LOM RANK Z 1 I 1 1—�d-_� -� -r i, — ,- ewe 5 ALOE wn arra mxlM 1 FUEL CONSUMPTION AT 100%=4.2 W o 6-i \� T� ��� 91b7 PLANT DOLOR EG691FlL OWE 1 GL/HR O ❑i� --4B SNB UP DPBR #ID MFT-10468 FUEL CONSUMPTION AT 75%=3.3 W~ Qi LL GL/HR Z )- Z W gco ' EMERGENCY POWER SYSTEM. Q(5 .-E UIREMENTS 367 - POTTER STANDBY GENERATOR SHALL BESUCHTHAT,IN THE EVENT OF e ,.w 124 OVERALL FAILURE OF THE NORMAL POWER.THE EMERGENCY POWER SHALL BE AVAILABLE 501119 THE 119E REONRO0 FOR THE APPUCATON BUT NOT W I I o . _ J ® I TO EMCEE 30 SECONDS. 0- ® I OUSTING EMERGENCY UGHfS ARE CURRENTLY POwEREp WV BATTER{ I�� 'I RALINP AND REAM TO STAR 10 SECOSDS AFTER THE POWER CC FAWRE CC EMERGENCY GENERATOR PRIME MOVERS SHALL BE AN INTERNAL • IP�T COMBUSTOR ENGINE FUELED BY DIESEL p3 TYPE A SUB-BASE FUEL - Mae /1111 .E;• __to - TANK SHALL BE PROWLED WA L ENOUGH CAPACITY FOR 12 HOURS OF p 'II ./ I 1LLL CONONUOUS OPERATOR AT A LOAD OF LOOT PoWDE RATING. `AUXILIARY FUEL TANK WTH CAPACITY FOR 96 HOURS IS EASIING ATR.i, - Iso �. THE FACILITY. _ I ______ Na Dau A,055 En .1. t. �rfl:":: • r - -i 127 _ CVSSIFlCATION OF:ETD:ERGENCY POWERSUPPLY SYSTEM. 0 - THIS STANDBY GENAND 11@ Afi SHALL BE APRT OF THE C, I. _ _ I 12 ELECTRICAL COAND Sliell BNRACTORRSHALL VERED AS IFY 19 2.01 THE EPSS ISYPE 30.AND CLRSS _ CAPABLE TO ACTUATE IN LESS THAN 30 SECONDS FROM THE INSTANT `14.5 A I I I ,I ___T- THE TELARED NORMAL PPSWER F FAILS.ELECTRICAL¶C ECONTNCTOR SHALL MADE THE rP_ "I�II,III AAAI I IIIIIIi.:., 11,,491111111111,,a...-� 202.58 - - L -U II D II ] OVERALL HE STANDBY GENERATOR 514 BE HEATED AS NECESSARY 0 _```Y b 1-_-1 { -1 Ir:E _. ,1— r�--2 t�-, ��/'' , HEIGHT , T!!,N\ BY THENTHE WATER JACKET AND BATISTA NANUFACNRER FOR COW STOOL AND 00 ACCEPTANCE.DETRAINED • • e Y THE EMERGENCY GENERATOR SHALL BE PROMIDED WEN A CONTROL ND 0 [] f PANEL CONTAINING THE FOLLOWING: sal A-AUTOMATIC REMOTE START CAPABIURY. B.-`RUN-OFF-AUTOMATE•SWITCH. Manuel MDIlined0,P.E. C.-SHUTDOWNS.ALARMS.AND CONTROLS AS REQUIRED BY NEPA 110 Florida License 063095 66 THE CONTROL PANEL SHALL BE CAPABLE TO CATER THE FOLLOWING INFORMATION: A-MGH ENGINE TWPERATORE PRE-ALARM B.-HIGH ENGINE TEMPERATURE(PND SHUTDOWN). 0 I C.-LOLOBE OIL PRESSURE PPEd D.-LOWW LUBE PRESSURE ALARM(ANDAND SHUTDOWN). ]fi $IT:HT SLOT234 •1 I RADA 1008 ENO _I F.LOUOwFUEI MAIN TANK.SHUTDOWN). i ! G.-CONTROL SWITCH NOT IN AUTOMATIC POSITION. H.-LOW VOLTAGE IN BATTERY. a I.-BATTERY CHARGER AC FAILURE E. J.-AIR SHUTDOWN DAMPER WHEN USED(AND SHUTDOWN). PA®N, 618043 K-REMOTE EMERGENCY STOP. ASSY AN EMERGENCY MANUAL STOP STATION SHALL BE FACTORY BUILT-IN De. 04-11-2018 B REVISIONS REVISIONS ON THE GENERATOR HOUSING./IMMORAL A REMOTE EMERGENCY ,0491 TLC P REV DATE: CHANGE MADE BY REV DATE CHANGE MADE BY GIVE-Al-1250-2000 ASSEMBLY MANUAL STOP STATION SHALL BE PROVIDED INSIDE THE TOP O AREA 5 IN M441NE PATROL MAIN OFFICE THE REM01E MANUAL S70P STATION APP°"°eal' TLC 1 12/8 CHANGE IENGHT&WIDTH,ADD LOAD BANK MfTB CUSTOMER/ID:FLORIDA DDA . SHALL BE LABELED. oo 118•=1'-0 I. 2 12/16 UPDATED SILENCER,ELBOW,&RAINCAP MTB JOB REF:MIAMI AIRPORT REQUIRED WIRING BETWEEN 100459ER SWITCH AND GENERATOR °x CONTROL 09 MOVE DOORS DRAWING REF:AAAD 14276 CONTROL PANEL SNAIL BE RUN BY THE ELECTRICAL CONTRACTOR m STANDBY PROVIDE NECESSITWKSY CONDUITS AND WFOR CONTROL FUNCTIONS DWG 45-25377 POWER COMPONENTS COORDINATE WITH GENERATOR/TRANSFER SWITCH MANUFACTURER'S° GENERATOR DATE:10/22/15 RRR6ENTATNE FOR QUANTITY AND SIZES. o DIMENSIONS B - DRAWN BY:SK era. >R Drawing No: ri 2 E-102 MO/ TALK GC GENSET YODEL COSSET FOOTPR9R TAM(WEIGHT 5000 GAL 051250 198.25'S 90' 16,525 LBS 1 L( BOL OF MATERIAL ENGINEERING FDEP: *= 2"PIPE TO TANK TOP UNLESS OTHERN75E NOTED 1=71., .. LETTERPART/ DESCRIPTION Ott FOR ARCHITECTURE TANK#EQ716 S 3166 F CPLG,8",E-VENT 1 3757 TUO Lagoon OUo D Dr. SultSPILL BOX# EQ567 ' T 3855 F CPA 2",MUM,W/3//4'DTP 1U9E 1 MIeml,FL 33128 BASIN ALARMS EQ817 �, I U 3655 F CM.2'.SIMPLY,11/3/4'r 7118E 1 Phone: 86995 HIGH LEVELS EQ817 x 1003 FLANGE,2',FUEL LEVEL GAUGE 1 '"®90)00015'COT 1315 RILANGE i 2. ANDA Up 1 1 Y 3152 F CFtG,Y.STANDARD VENT CRP 1 pc,*ucc nOem.natrAvmea. g El .M. $ 8 4 �'-• Z 3005 FLANGE,2',LOCKING FILL CAP 1 N 0 0 R U B R S3$ 8 UP P$ 8 . Cl 8 - -- A 4301 01-1/2'PIPE TGE,L-30-1/Y SPEC F WLG.1-7 2,LD-FPI-BBIS ROM 1 ' I -g I .- f'I 1.5 I ('1YPI I ISOLATOR SUPPORT tl1ANNFL B 3502 FIANCE,1 2'.BASIN DRAIN 1 lb F I d (MSS-lE-25755) 07Y:12 C 6410 1/2 FLUSH MOUNT LIFTING PLATE 8 O U ',��.,�' MAT:C405.4 W/.25'PLATE D 8003 REMOVABLE END PLATE-3'BEND 1 J _ _ ��-n 1,5_1 /��(T E 4000 48'STANDARD ELECIIHCR SNB L4' i '.I' •711I a "16' F 3600 F CPLD,2",FT111NG W7 1/Y OP TLBE 2 Q 1 NM Ii,,,, ®UL 142 LISTED PRODUCT 0 1093 FCR;Y, CONTAINMENT OA REP OM) 1 LL --77 Fie N,oDfie,s: J 3188 FIANCE 6',CONTAINMENT E-VENT 1 1` "� ill! �, MH1e4e1 MH0000S MH25279 K 3196 FLANGE 3,FITTING W/PWG 8 Z cc B .tel 0 ,gym M L 3190 FLANGE,3/B',PRRNG W/PLUG 1 Si M 3191 F.CPLD.1/2,FTIRNG W/PLUG 2 W 1 ¢- • 8220 7 GAL SP93.CONTNNHENT BOX 1 1100GLSUL1426UB BPSE TPNK-EUO 55] �' m V weSv�, 8303 6"I-BEAU GENSET SUPPORT 8_ Q 8420 ISOLATOR SUPPORT PLATE 12 Z W rue .,....c....,....- - ,...c....,� 8426 GPC 400 C ISaAT01S(�5-1E-2576 12 Q Z 1380 SEM 400[aOgN111(mnrncKOM 1 W �� 2025 SINGLE SUPPLY PUMP SYSTEM 1 F-?17 2) 1/3 HP CARBONATE MOTOR,1A --(iEiA RECUMBENT:HHAsnn HSU...ANCHOR Boos ns/2205,50/60x4 4812 FRAME 1 {� JI ' k -4808 PSCRALNEoCarcoETE. 6040 BRONZE CLOSED COUPLED 4GPM 1 • UI s "I I 1 I I i I 1 ROTARY GEAR PUMP.3/B-PORTS UT ,O� re II PROVIDE SIGN PS PEP NFPA]ua FON FUELSUFPIYT)U. 6400 03DR FLAP BOER/as FO9919L1'RIP 1 TM FE ooi000016ET1¢aemuroR 2010 REVERSE PUMP SYSTEM 1 a O IX INDICATING HHA 000- a. 172 HP CAPACITOR START MOTOR 23 -irvDOUG-FLAMMABLE o- MA 4� 14 115/2315,6094 48 FRAME 1 ,Vp` 1 E y 17svEciaLHar O- 40, 8570 BRONZE CLOSED COUPLED 7GPM 9 Ihs I II I /�( ROTARY CSAR PUMP.172'PORE 1 T__4 N'_) - "'VVV"' 700-1073 1/2"FUEL STRAINER 1 I I J SUBBASEFUELTANK 700-1065 1/2 SPRING CHECK VALVE 1 �4e� ( I a, DE • 3 i T 70Y109E 1/2•SOLENEID VALVE pzwAG,NC) 1 No Onte D�I I i%%OP UL2085 DR FIRE RAID DOUBLE WALL TANK 1 9838 PANT COLOR GLOSS BLACK GENSET OFFSET 6" TO LEFT SIDE S 124 - $ 00 S 118 BEAM 4— S 37.89 62.25 2588 AR x>TYP(SLOTS I I I 1� t. , I 241--I 5 8 _1_2m I. 1 L�1'F' Rm Manuel MDIrD.I Y E. IV rr �r Mir -_I It TMP F1"'Gc 7fi� �—•'II . Florida license#60Wfi II 0 Hil 0 1 ee 1 P,4m rx: 618043 i i_i m:: 04-11-2018 A1'HOLE T—' RADIATOR END ??1 n' " D,- TLC 0p K.CR005015 1/ I I I RIGHT SIDE' TrP(1 1 I II R 'OWED APP"'meY TLC s WN091PPoRT "� $ BOTfOY $ 1.8-11 115 -I M w s®e 1/8'=7'-0' F ...= - R $ m LJ LIE 11e O" SUB-BASE TANK 8 DAILY S FUEL TANK REVISIONS REVISIONS SUB BASE TANK RUPTURE BASIN g� STUB UP a: P. REV IDATE:I -... _._ CHANCE MADE I.BY I REV DATE:l_.._ __.____CHANGE MADE_.. I_B1'ISUB BASE TANK �/ AVtEU1MD BASIN OL R7EUD UC M § • E-103 8 I 7 I 6 I 5 + 4 I 3 I 2 I 1 1L( DEO mm«w 1100 em GENERAL NOTES '.„a".RR<. R.Raper.R>atmama cane NpRn_ ENGINEERING ��' JII\ - ma rawea rawa ea ulna`m`< - - FOR ARCHITECTURE 5757 Blue Lagoon Or. D i � ' 1 `�e+' 'm" ow .. K maR, D Sate 400 I I Saaoa.eo ss Mleml,FL 33128 p IS 110401.41.0 a'Pa We ei 107a P. ^ram Phone:305.268.8553 a, Pam o Fax:305.288.8695 'i:/ \I1 s. MIT'reu rax+:sa SPra:m 5270 x,L wo w.x n,ap wwatloenglneere.eom I• {COP.DM MED.(sxo+C VOWED SWAM a!xvusl �._�__.✓____-_ ®00000015 4. 0 Pat(aftaaa ox f.rvsmmn Lan)7.704:777,fce locol ADD non Aana rwrkrt 2amEy�npbxenmoe,ee S4P_,MDEI 5 uuvra/000.001.px uNx.. • m.m —,,,.,,, am SPECIFICATION$ 1i1 T-K DEMO.VOCE Wei AO OD OVUM DI A PEK11 CC • PROICC.8 M.&a.• ae on B naft Ria 1 LA ANTEO.CV O W o q A ALC B.va USDAdna IIE�tI#ti y�ytl�plAttWarra70.45CMDC AS PK.. - -Immo �� ...� .NP02(525510141. ..5*58 « •-.., 1 li*I±I±I aftlantRallE 4120t a lw„ r NOTES 1600-7000 AMPS a,xE mfg NcanR. FROM ELEVATION .FRONT 51FW:..100 SPRIER ,SIDE'AU REAR RID/ 0.041()uw a=AND 0 510 e. IVI 58 �47 m.(5,• .0 MAD a w+moi 1.1 ISWOK.FOR lia M NT mw)la/a pe10 Me IV.. IMFRIL)R NEW eearo>Pacr¢. P (mu,o au'x0 53 was,0345*1400.0. mx COX i nt.412.004ws%a W 41. A 4 t TEsTor ODA:._PACE P PM,Lm Na w To sa(e 0.N.So C 510 7R now. _ B ON IIS arm ,am nm ,( dLuas ic�''wet> B Na on. os<oWum _ 1'"' CIRCUIT ERER<ER, ITEM 02V P ,l6/• .ux Low oo. oa.,..m s 1500,000.0.0000/AV..uw.e.�P.,w I i B* im Null. ma. E E• / ` m l I I`[ L wae� L GENERATOR SET \ �} — 10 { 0 sN SOLE 515. PLAN MCMI N arra g x i 93.03111 __ _-_ _______.__ ____..__ ____._._,-. \ 5m1 _ Manuel Mollinedo.P.E. B sof l .) �A'M Florida License X6}096 ftar 52 acn EiEY'7 P`Tn / p acum A m l al aMrnrto A :� lq I c, f Sm ;M. .63 w`ra _ a lnl 1,_n.n A • /7":"' .:»"e - fir, i SCR (Fa i0aas �,f re E (5/ .i.<I.. `` 1 bo,EwE IwonR x S II c.,w l l ''OD�" j us•redox,_mm..xn.s BM= �'�'. ,m.,; Ol... ,.�. rmeit L \` ". —m- •:_I......... ,,, 8 (WITH SOLID NEUTRAL) ('MI'H SWLTCHED/OVERLAPPING NEUTRAL) -� ,1-,tee, - _e573-051 -DS Yor 8 I 7 I 6 I 5 t 4 I 3 I 2 I 1 Prop.. 618002 • ,s,,,,,,„, MECHANICAL _ STABS 03-3)-08 • tV SUPPLIED 022(i)WG PER D • PHASEANO NEUTWV.EPLHB TPBLETYPE)FGRCONNELTIONN OLUGS 0611-1S F EMERGENCY SETS OF FABLES m a TLC • UP TO B00NCM CU/AL App204l5. TLC 2 GROUNDLUGSAREPROVIDEOSTANb1RDAS FOLLOWS:(0)61N-3N AVGd1/AL DAB.. Sc. 1/8"=)'-0" W D 01CI117 BREAKER 12220516 m AUTOMATIC 1. 1W%RATED MOLDED CASE CIRCUIT BREAKER EOGAF/&%✓TSOLID STATE ELECTRONIC TRIP. TRANSFER SWITCH e DIAGRAM M ore BNp. E-104 I AOA TAW POWER SYSTEMS, INC. % scos 1500 NW 15th Ave Pompano Beach, FL 33069 T A Ph.: (954) 977-0202 x1759 (800) 876-0990 ‘14‘ Fax: (954) 977-9249 John.Potts@tawinc.com Kohler Generator Systems Distributors KOHLER POWER SYSTEMS DISTRIBUTOR FOR ALABAMA, SOUTH GEORGIA, FLORIDA,LOUISIANA AND MISSISSIPPI Date: August 8, 2018 Offer No: P1808-0106 Contact: John Potts Contact Cell#: (954)-234-4226 Project: City of Miami Beach—Property Management One New KOHLER Model 500REOZJ, EPA Certified Diesel Generator Set, 500KW, @ 0.8 PF, 60 Hz, 3 Phase, UL 2200, 277/480 Volt with the following: CONTROLLER: ADDITIONAL ACCESSORIES: APM402 Certified Factory Test @ 0.8 P.F. Controller meets NFPA 110 3 Engine, Generator Parts, Maintenance Manuals 1 Electronic Manual ENCLOSURE: Vibration Isolators: Internal Aluminum Sound Enclosure 5 Year Comprehensive Warranty 181 MPH Wind Load Rated Critical Silencer SUPPLIED BY OTHERS COOLING: New Fuel—First Fill of New Tank Unit Mounted Radiator Installation Block Heater, 120 Volt Local and State Permitting by Others All Infrared, 3rd Party and NETA Testing if Required FUEL SYSTEM: Flexible Fuel Lines Sub-base Fuel Tank, 1,700 Gallon, UL142 Listed FDEP Package TOTAL NET LOT: $103,950.00 Fuel Water Separator GENERATOR ACCESSORIES (Electrical): ESTIMATED LEAD TIME: Line Circuit Breaker, 3 Pole, 100 % Rated 16 to 18 weeks after release of the order. This Qty(1)800 Amps, Electronic, estimated lead time is subject to change daily due to ENGINE ELECTRICAL ACCESSORIES: availability Battery Rack and Cables F.O.B. FACTORY, FREIGHT ALLOWED TO JOB SITE Starting Battery, Lead Acid Battery Charger: 10 Amps SALES TAX NOT INCLUDED CONTROLLER ACCESSORIES LOOSE: Remote Emergency Stop, Break Glass Regards, Remote Annunciator Panel TAW Power Systems, Inc. AUTOMATIC TRANSFER SWITCH: John Potts Qty(1) Kohler Model KEP-DMTC-0800-NK Senior Sales Engineer 208 Volt, 3 Ph., 3 Pole, 800A, NEMA 3R, Service Entrance Rated OFFER VALID FOR 30 DAYS FROM THIS OFFER DATE (LISTED ABOVE) Page 772 of 1648 EXCEPTIONS/CLARIFICATIONS/NOTES: (OFFER ACCEPTANCE BELOW) Delivery, start up, and load testing are quoted as during normal business hours. If after hour, weekend, or holiday work hours are required, the Contractor will be responsible COMPANY for the overtime differential unless otherwise noted. AUTHORIZED SIGNATURE OFFER BASED UPON: TITLE • Drawing E-101 PRINT NAME DATE NOTE: TAW's STANDARD TERMS and CONDITIONS apply to all TERMS & CONDITIONS ACKNOWLEDGED: offers for purchase and any purchase orders accepted by TAW.You may find a copy under the terms and conditions section at TAWINC.com or please contact our office at 800-456-9449 and we will forward you a copy.TAW will transmit a written delivery schedule based on the INITIAL manufacturer's confirmation,approximately fifteen(15)days after product release. Also included will be the related progress invoice values based on material shipments. All TAW offers,plans,specifications,and technical drawings are copyrighted works and contain proprietary know-how of TAW,and Buyer has no right to reproduce,distribute or publish copies of TAW's copyrighted works or to create derivative works of TAW's copyrighted works without the express written permission of an authorized representative of TAW. Page 773 of 1648 ®fir, � XJ� Detailed Scope of Work THE GORDIAN GROUP To: Andres Solares From: Isreal Baker Solares Electrical Services, Inc The Gordian Group 10421 NW 28th Street 30 Patewood Dr Miami, FI 33172 Greenville, SC 29615 No Data Input (800)874-2291 Print Date: November 06,2018 Work Order Number: 062105.00 Work Order Title: Miami Beach Property Management Office New Generator Brief Scope: The following items detail the scope of work as discussed at the site.All requirements necessary to accomplish the items set forth below shall be considered part of this scope of work. Detailed Scope: Provide and Install new generator,ATS,conduit,wiring, concrete pad, demo etc as indicated in the electrical drawings E1.01. Subject to the terms and conditions of JOC Contract FL-MDCAE04-052014-SES. Isreal Baker Date Andres Solares Date Detailed Scope of Work Page 1 of 1 11/6/2018 Page 774 of 1648 QUOTE# TANK GAL. GENSET MODEL GEHSET FOOTPRINT ASSY:WEIGHT I 33787 1'100 GAL DS500 132' X 74" X LBS -- - BLL OF WTE9eL -•---m —170.88-OVERALL wont MSC:Knee '" ENGINEERING 66E-0.1 KUMPL051606StRucn6e Inn} FOR ARCHITECTURE 640.'9 61816614SI8l 1166 MRER1R:fIFDit, 5757 Blue Lagoon Dr. - �. D . 6]m �'COW Sults.26 =,f�� ❑oi���' 400 �1 SMILE. L Miami,FL 33128 B6W MEI)W WS NaRnarm L044E8 Phone:305.266.6553 6600 EtlEOLSOFOAMAMOE KILL Fax:305.268.6695 Q X� 4�'K 0900 2•BLACK FOAM TEED 09fN wxxgoen000015 .Com O O 00If mon®r 11 604 cvsTmcB SUPPLIED F1n: ®#001)0015 ' •ii 1�LI 1PI1 66� B M�62WkY33TEW 0m2etau,me 9eAmeee. _-� E�,�ul�111 w ��ii' B, IMIER44LYWs YMW�N1F0 sueretR on f I^ .i i - `•'VE81ceis f0GLR 615WVAIGE ■ EI ■�j II 1 I L = �L�,j d 1 84 4676 MOCK 86-66-6000 IIr■•7 •-- Frye•'1.111• OVERALL WW CAP:Pr-65-01-08 ti llil� '-i^'- 6518 WINO FlW LS/0PA111 TO EVERIOB :IAS.= 66:11;r�L Yl11y► �IC-7� haus W6:2 ROCK80 0R 07.5 • All lir innk1 r' 47 _-I� I! 6904 WWII'e WIFE KAMM'CKMGCi F OPEN o t1W mT`E® N I AL_-:_.. SPaMa 1-i2µ{.rues yetis Z O I.. '� 57167 PNwT COLOR EGGSHELL win W 1. , H r� .'r.° N 2 C C C .. C — O. C w 10–FI `1 !� Si ' '1 ¢LL 20.5 OPEN' 1c V >U 6 60 Q mm j �89 OVER/1LL EL 1 '—P � a dna Ill 1171!"11 :6,1 111.1111111 �lil IliilI!1 1 158.13 :110g �'� �F. a�� iI 108 11111 E■L■k @ iI oe�c4>,1� ovERnLL _ e��. ■i'. 1gG5 Ir I I I I# n'9 iii�il I—. S SHIP I {tea c°i �F L 1P11I�r�,'.'� I r.ti=m1:1111,0111&mil— �-iYlll Ir I'1 IyI IN IQ �� � _r • ir '■ JO X11 01 I 0 IDS 33.51' irmr Seal Manuel MoIlnedo,P.E. Rondo Urenoo#63696 L160 .1 '^70--J THIS AUTOCAD DRAWING U THE PROPERTY OF GLOBAL PURER COMPC#UNFS MID WAY NOT BE USED N ANY WAY DETRIRENTAL 10 ONE INTERESTS OF G.P.O.ANY MVNAL CHANGES WILL 1410 TRIS DRAWING,SPECIFICATIONS NAY CHANCE W11HOU1 NOTDE I ASSY 5)005 REV DATE RCHMNGE MADE BY REV DATE_ REVISIONSCHANGE-MADE BY GIVE—Al—500-1100 ASSEMBLY i CUSTOMER/ID:FLORIDA 0DA JOB REP_ DRAWING FIEF:MA033787 ocean. 618043 DWG :X POWER COMPONENTS 'uoe Dat DATE:5/30/17 04-11.2018 DRAWN BY:MTB Mae:Or TLC ro..e Ir TLC 4 m i STANDBY GENERATOR DIMENSIONS 0 E a gDrawing E-1.02 Pepe 775W10a0 SCOPE OF WORK: 1 L( KEY NU I ESI THE SCOPE OF V ORK FOR THE PRESENT O,ou _ _ DESIGN IS TO PROVIDE STANBY POWER TO FOR FURTHER MAIM!BEACH-PUBLIC WORK FACILITY. Q OMATICDIAPER SMma SERVICE RAIED.mm-ePalEwPu. OASIS OF DESIGN _ WC.-NODEL "' 'rrSE,rMKNTM A MANS• THIS SHALL BE DONE BY INSTALLING A 600kV BMA3 POLE.SOLID STATE IABEI.OS VAIN 1 Oi, Oi NEw _ ORS RmAuEowloEaruomn REFER ro DIESELFUELEDGENERATORQ480.2T1V- THREE PHASE. ENGINEERING P&L \ 6'01AN L.NI FENCE OO DIAGRAM RREFER TO RTR NEN/GENERATOR 7RI o rnrro�DTOMEMOR„w.. FOR ARCHITECTURE VAULT \ ®NDN oA UNDERGROUND.Ar IE•erEREeEaroRISER CILAGRAM FOR YORE FriZES 5757 Blue Lagoon 400 MIDr. suBe 33128 \ 0 EXISTING ROOM INSTALL NEW...ME OROJR BREWER TO FEED GENFRATOR SWOON LCAOCENTER.PRCVICE PANEL ORO,DIRECTOR,REFER TO PANEL SCHEDULE FOR FURTHER INFORMATION Phone: 3 FL 400 305.268.8553 \ N+DwxnaTnA snon .6695 wwex:305.286me.c 09149=PAVEMENT OO EN tl1I#0000015B .t6 \ O NEW TDEVVGENERATOR. KOroNENDrN.meONEC.:R. PAn Dc e<At NM ncnm..cotrAeve.aec ®a • \ .0 aLTIxore,wxuNcwmaPANEL SUTTON \ O .. i�� energy 6D u . CC n \ m O 1i,.; IIEC4:,/E_=CT Rbl ,,'I -w- I ,......rm. „..ti ... �I. m L Ij FIE;TANK www, V W 4"E I r«.w. ev e..•yw. I ese [MM. ws C\TRC_RCJH 0Nuc r o.aa ex.,w wad M til I'll II O m .N. In Ili LVA ME 2 Ij, GENERATOR n,wx rn.�+wo.,. wea,..e,u. '_ P\ n PF _ eu ST („renfanromrt„ ION ....amt.cam ailO(O3N.arm f nELECTRICAL SITE PLAN 17I \�f'f n rtV : n^ Nab scut Ve'.I-afel Leee.ra ..,.,.,d.a� ..- iJ D�ww� -W -0 .�. KEY NOTES: Seal Manuel MDllinedo,P.E NOIV . ' PESO.MED SAMS OF DESIGN,LIIJ YODEL POLE.SERVICE RATED.MOS OF DESIGN A920 GENERA ORM O MN O x 10V1400 0.130 WITH ONLY MSS TANK OF.ueELasaEoulam eTs Florida License W67096 0 GENERATOR DISCONNECT.400A.SPOLE 1.411N 1 0 NEVI sar AND GROUND BAR IN GENERATOR SET WS BEEN TOTAL • 6 -0 P L® oD 0i"m � EMG Dllxil�mwm l.Ht XIMICTORAU ENCE 8110 AVM GN/PH - (k � m EeMOW.Ri GENERATOR ONEwr RATE Gu RODEmRATION.NOM v„WP,P`RDD DAILY e rsi.s • Q ROWER BECONV60/SETSEACAWLS N6E1,4).00IN V ....WN.nl PHD : gi . coxes E DING WIIESEPNEEx GENERATOR ROUSING ®te•ar6 �� �a THOSE (E,, ErgEcNs,,,,.eoex,,,,.Nx.l,l AND.GRwL.ALSO OMT• ` M.P EIIG,PROVIDENDN.a-2PD� a�m . orrlwURAUEOEEaAR„GENERATOR Or emiawlTeaEem,waosmox,..,aroaEm 618002 STRUCTURAL' NaxLREMMN LOAD I. DOLE a roR D NGREe� ®.Ws O ©rysE P.CIxUNDERGROUND ISECTOxllx PC 03-3,-08 ® ) ,w 9, TLC DUSTING MX I OF I,SOOP MAIN CROAT BREAKER.THIS GSM.NOTRE LONGER/OM • Po*B, TLC ®Ew 1/8”=1'-O' , TO pr..,7.1¢ DISCOHNECT FROM POWER SOURCE.Cry a GENERATOR •EMPTY CONDUITS AT SDrN Eros . FLOOR PLAN& E RISER DIAGRAM a > ,'PARTIAL RISER DIAGRAM i; Orem, '4'., )rUL ,S m E-101 • JEB I TANK GAL GENSET MODEL GENSET FOOTPRINT TOTAL WEIGHT -GENERALISPECIFICATIONS: AND S - ERASIGNS: AND STANDARDS: 5000 GAL DS1250 198.25"X 90" 48.750 LBS NEC 2014 EMISSIONS:COMPLYING WITH EPA TIER 3. 1 L( ALL VERTICAL WALL& MANUFACTURED IN ISO 9001 AND ISO 381 OVERALL. DOOR PANELS I ROOF PART/ N61 DESCR�TFRIAL CM 14001 CERTIFIED FACILITY. 169.25 PANELS 2S FIBER GwE_Al NDNNM CONSrRATERY(DBO..mT -�1D225 - INSULATION BOARD W/ 6813 lee NPN 15 ER RC ROwaampt UL 2200 COMPLIANT. PERF SPECIAL YCACT RATED PER NMMM R MTM _ $501 ACCESS DOOR ISO 8528-5 FOR TRANSIENT RESPONSE. ENGINEERING K _ OI U MOO asa STAINLESS=a L 0001GA1D00MAKEROOOEO FOR ARCHITECTURE i II Bele EOD9 c VGTEAL SOLA.am POWER RATING:ACCEPTS DESIGN LOAD IN 5757 SIAL 040OU n Dr. ONE STEP PER NEC 110. YJ0BBR INSULATION BMRu MnoF 3 FL5.33128 'WI!NW'. , G'•� 80 SPECIAL UNE INIFR03 69 wl kVNPt11t 7440 POWER FACTOR>0.8. Phone:305288.12553 M I 1 •n I•� -�e 1/ki�i - 6803 1058860 RAINSUPCOLLAR F704MG7 MX 2 YEAR STANDARD WARRANTY. w v/ax:3005.266.. mm I���P• �� • I6840 CPC SUPPLIED CANALISE 515184 EB 101100015 -� I,�� T — IMQWA=MOUNTED SILENCER oOOPMt fiA T6R*91 N80100SNe / . ` - eels SW GPC-E-O-12-16-0750-89— CHARGING ELECTRIC STARTING MOTOR-24V. 112 ( --:- �1✓ vER8%a SILENCER 6 E SUSTAINED ASHORTACIRCUR CURRENT UP TO / 4 - SEATO ELBOW:[L-6F-G16Po-Sw OPENLb�, ��1 H-- - 124 RAW VP:PARKER 549-69-61-16_ 3009.IN 10 SEC. 6800 mum EROSION _ 4 6518 edbi-D R91EVC N6 L VALVE'NW n��m',u,y - ` 01.R REGULATOR.L,SOLID STATE,VOLT-PER-HERTZ ii C.�iEi ,R:(1� „(„.Ti.,T•I�i67`,.• 7Jii _T 6404 MDUNr&IME BATTERY cRARrFR REGULATOR. II _ I,�-.�__�.. °PO2 MOUNT a WIRE BUN.NEATER 1 '■ BRIO NCANOESCENT LIGHT PACKAGE J_ _ __ `�!i — +1-0.25%VOLTAGE REGULATION. M� 0 O® - 6911 --LUTFkpfT 10TTTO 100 _ Q O 6916 Era88 OUIIEiUIIC n9- COMMUNICATION TO REMOTE ANNUNCIATOR. ��-1 6418 1566 wmRDM1u(14.1003E-407•8 08 ENGINE JACKET WATER HEATER, 1 T-� - O - O- - on - 0500 VOM qSf PANEL(1�.i10T 1-•• gi ® 6�eease NOW Y M°LINO PAM 5 FUEL CONSUMPTION AT 100%=4.2 Z(Y 6—I —� �� 91.67 PAINT COLO FGGsmL wmE GL/HR N Q EJ- 4BSNB UP— DPBR #ID MFT-10468 GL/HR CONSUMPTION AT 75%=3.3 W~Q 2 i ZW g0 '' 9-w 2- EMERGENCY POWER SYSTEM. 2 V1 • 381 ^ , POWER SUPPLY-GENERAL REQUIREMENTS } .- c-- } 124 OVERALL STANDBY GENERATOR SHALL BE SUCH THAT,IN THE EVENT OF FAILURE OF THE NORMAL POWER THE EMERGENCY POWER SHALL BECC — AVAILABLE CHIN TIE TIME REQUIRED FOR THE APPLICATION EKE NOT L0 TO DREED 30 SECONDS. O ° "di ® I EASING EMERGENCY DORIS ARE CURRENTLY POWERED BATTERY II 11111 1J BACKUP AND READY TO STAR 10 SECONDS MER THE POWER EL 1,1 FAILURE d lel / •^•,�I ENERGY NGENEIFUELED E D BMD EL SHALL 12 TYPBE AN E SUB-BASE NAL COMBUSTION ENGINEN Y DIES A S - NEL TANK SHALL BE PROVIDED WITH ENOUGH CAPACITY FOR 12 HOURS OF ------ MINI `IFigi��I. - • - - - - AV%VARY NEL K:.11 CONTINUOUS GWITH CAPACITYR AT A LOAD 0FOR F 090 HOURS08 ISAIXLSTING AT e.z BAN -- ■�1 II I. THE WRAY. ^ ”' • • I. O• I • M - -I AN 1.7 CLASSIRCATON OF THE EMERGENCY POWER SUPPLY SYSTEM. B • _El,: _ • 1165 STANDBY GENERATOR AND THE ATB SHALL BE PART OF THE . . IEPSS AND SHALL BE CLASSIFIED AS LEVEL 2 TYPE 30,AND CUSS C c] 1 _ _ __ -_ •A 12.ELECTRICAL CONTRACTOR SHALL VERIFY THAT THE EPSS IS 1 CAPABLE TO ACTUATE W LESS THAN 30 SECONDS FROM THE INSTANT . •A''.111111111111i111.I, II,� "-. �1 I -- I 11— _ _!.. REQUIRED ADJUSSTING TO GET THATI�CONTRACttIR SNALL MADE THE N M r J __---- 2O ERALL O HE SANDBY G N U OR SNAll BE HFA FD AS NEC6W 0 '------___________________LL .1ie � „�� 193 BY THE WATER R FOR AND BATTERY AND TEMPERATURE 110904INEO 1 y 1 I. _ ILII 1_I ' SHIP BY THE MANUFACTURER FOR COLD START AND LOAD ACCEPTANCE. my yy HDGHT ^� THE EMERGENCY GENERATOR SWNL BE PROVIDED 01111 A CONTROL O 0 O DO PANEL CONTAINING THE FOLLOWING: ' A-AUTOMATIC REMOTE START CAPABILITY. s®I Manuel Molline40,P.E B.-"RUN-OFF-AUTOMATIC"SWITCH. FlOnda Urense 63096 5-SHUTDOWNS,ALARMS.AND CONTROLS AS REOUIRED BY NEPA 110 • 66 THE CONTROL PANEL SHALL BE CAPABLE TO OFFER THE FOLLOWING INFORMATION: A-HIGH ENGINE TEMPERATORE PRE-ALARM B.-HIGH ENGINE TEMPERATURE(AND SHUTDOWN). I C.-LOW LIRE OIL PRESSURE PE-ALARM E 6 D.-LOW WBE PRESSURE 11ARM(ANO SHUTDOWN). 3 SIGHT SIDE 234 !I I RADIA O END _I F.-LOTANK. 1188g�"" ]6SHUTDOWN). 1 G.-CONTROL SWITCH NOT IN AUTOMATIC POSMON. H.-LOW VOLTAGE IN BATTOD•. L-BATTERY CHARGER AC FAILURE TE a-AR SHUTDOWN DAMPER WHEN USED(AND SHUTDOWN). PMe9No.: 618045 K.-REMOTE EMERGENCY STOP. ma.m. I ASSY AN EMERGENCY IJANNAL STOP STATOR SHAH BE FACTORY BUILT-IN 04-11-2018 W REVISIONS REVISIONS ON THE GENERATOR HOUSING.AODMONAL A REMOTE EMERGENCY � 8,. TLC E REV I DATE: CHANGE MADE BY REV DAIS: CHANGE MADE BY GINE-AL1-1250-2000 ASSEMBLY IAANUAL STOP STATOR H MARINE PATROL MAIN OFFICE FICEL ETPE VIDED REMOTE MGM_ �E�Pt�AREA �tl� RD 1 12/8 CHANGE LENGHT 8:480T8 PDD LOAD BANK MTR CUSTOMER/ID:FLORIDA DOW • . ' SHALL BE LABELED. M 118.41.40" y 2 12/16 UPDATED SILENCER,ELBOW,&RAINCAP M18 • JOB REF:MIAMI AIRPORT _ REQUIRED MEG BETWEEN TRANSFER 580tH AND GENERATOR '° '"°0 TPA MOVE DOORS _DRAWING REF:AAA014276 CONTROL PANEL SHALL BE RUN BY THE ELECTRICAL CONTRACTOR. . STANDBY DWG 45-25377 PROVIDE NECESSARY CONDUITS AND WIRES FOR CONTROL FUNCTIONSO S POWER COMPONENTS COORDINATE 0TH GENERATOR/TRANSFER SWITCH MANUFACNRER'1 GENERATOR • DATE:10/22/15 REP6ESEN1AINE FOR WARM"(AND SIZES. o DIMENSIONS S DRAWN BY:SK . R x i B °� E-102 X8/ TMA GAL GENSET 6000- GENSET FOOTPRINT TAW WEIGHT I 5000 GAL DS1250 19815'X 90' 16,525 LBS 1 Li( FDEP: *= 2'PIPE TO TANK TOP UNLESS OTHERWISE NOTED g„ Blu of MATERIAL ENGINEERING r='gr - LEITER PARE/ DESCRIPTION.0,6', - WY FOR ARCHITECTURELagoon TANK#EQ716 S 3166 F CPUC,6',E-VENT 1 5757 ewe a0000 Dr. Suite 430 SPILL BOX#EQ567 ''f°d„ T 3655 f CPLD,Z',RETURN.W/3/4'DIP 7118£ 1 Mwml,FL 33128 BASIN ALARM#EQ817 .6 , / Tr 1 Phone: Fex 3052688695 U 3655 F CRG,2',SUPPLY,M 3 4 OP RISE HIGH LEVEL#E0817 . I X 1003 FLANGE.2',FUEL LEVEL GAUGE 1 ww s.uoongInoem.mm 1003-IS90011 IA 11B61E,bos(56439)150) 1 ®90000015 ��qq 8 8 8 ,tRr. Y 3152 F CPEO 2',STANDARD VENT CAP I e400.mm5C �bNeet.. 10 5 2 5 S B B ..aa g 8mn B 8 p i , Z 43015 FLANGE, IP.LOCKING 30LL CAP 1 8 ,� 8 A PCI F OtTO. PIPE,IDE.L-30-1 GGG���,,, SPECIAL F WG,1-1/2',ID-PPI-SIS FLOAT 1 n-8 I�� "' ''1.5 I rT(P� I 11(MSS-1E-2575N) SUPPORT CHANNEL B 3502 FIANCE,1/2'.BASIN DRAIN 1 U ►C. . �, I (Ms5-1E-zsTSN) DTr:12 C 8410 1/2'FLUSH MOUNT LIFTING PLATE 8 ° i. I B J NAT:C4X54 W/.2S'PLATE D 8003 REMOVABLE END PLATE-3'BEND 1 011- ) ,jMAIN15 E 400(1 48'SBWpARD ELECTTOCJL SNB lP 1 'J �: 1 6 F 3600 F CPLD.2'.FRIDIG W/1/2 DIP TUBE 2 U uL.SNU UST D PR00ries,IID. ® G 1093 FLN6,Y,36'.CONTAI RIP 1 1 Ct UL tat LISTED PRODUCT (� DUmI LL `. I 1 I II FosISSSE Ms: J -3188 FLANGE.8`.CONAINMENT E-VEHF 1 F m IF 4 ill! I' MHlsaal MHwTn3 MHzs2m K 3196 FLANGE.3.FTRING W/PLUG 8 Z L 3190 FLAN(E.3/B',F TTNG W/PLUG 1 W G1naALwrROGM�aMNrs 9 3191 F.CPLG.1/2',FITTING W/PLUG 2 W o LL ttoOGLS uu4z suB-BASE TANK-Eae SG7 8220 7 GAL SPU-COHTNNMENT BOX 1 cc F4 8303 B'I-BEAM GENSET SUPPORT 6 0 IoUsamm7 8420 ISOLATOR SUPPORT PLATE 12 Z W aue . �� 8428 (5C SIP41ID b'D.M(IT6 Q05U IOU295) 12 Q W ' 1320 SR6SS 400[OKIIBIIEII(9NGLE/IhT41SE) 1 VP 2025 /NGLE SUPPLY PUMP SYSTEM 1 }} aucHOR REouwFMENr: 1/3 HP CARBONATE MOTOR,10 •st EMBEDAM EMBEDMENT NEW ASV.F1554 GR.105ANG°R SOUS t 115/2301,50/60Nz,48YL FRAME EY I I I L� ,I II - NO NIUNACKLn0ONCREIE. �O BRONZE CLOSED COUPLED 4GPM 1 0. I 'I I 'I I ROTARY GEM PUMP.3/8'PORTS ILI PROVIDEcNrs PER NEPA 761 FOR FUEL SUPPL,TANK, 6400 ME KIP KINDIO.FOR SART RIP 1 CC ry� b INDICATIG o LLOMEGA` M. 2010 REVERS PUMP SYSTEM I a "' b 1/2 HP CAPACITOR START MOTOR -FwnNAe�Hwao- z © td,115/2301.6091.48 FRAME 1 ® 'I I ' 43 sPEG� G wA �♦" e07a BRON2E CLOSED COUPLED 7GPM • ROTARY GDR PUMP.1/2'PORTS ' F--I _ r 7021025 1/2'FUEL STRAINER 1 e % �� r !�I SUBBASE FUEL TANK 70-100 1/2 SARNO CHECK VALVE 1 1.-48.—I (�/ " 75?. TAP SW x or ns 7022098 1/2'SOLENOID VALVESIZNAC.NC) 1 Na ere Oem�Pom 411-2085 2HR FIRE RATED DOUBLE WALL TANK 1 9838 PANT CO1OR GLOSS BLACK GENSET OFFSET 6" TO LEFT SIDE 6 124 �° ,�, _, .5 n S 37.88 118 SEW �� 4 aNtr O GA TrP SLOTS I I I 1':,1 7,1-1-1N _ Al —1�r-2.2s 11,.E s (41G N S 8 6t� TIP i!_I Manuel 6oILnedo.P.E II' 7� r� �iI ,,�f < r: m I FADE /1611�� r91 �- F 1 ur.�re 1e3D95 0 0 0 IIII 1 66 i Project Na. 618043 LIII 2 Issue Date oa-11-zofe $ 2 I I I RIGHT SIDE 1 I Tin(1 � �I RADIATOR END ,.A. ne h. TLC $ #"GUSSETS 8/ q —I4 5 WNO SUPPORT p 4 51 5 807702 1.3 113 HOLE f o 118 u SUB-BASE TANK WDAILY e. REVISIONS REVISIONS E.E. FUEL TANK REV(.DATE J.. __.__ CHANGE MAGE..__ _. _-...L _I REV.�.DATE:.I_ ._. ___ CHANGE MADE....--- .. -. .1.621 SUB BASE TANK V RUPTURE BASIN & STUB IIP. o i — �� E-103 • 8 I 7 I 5 I 5 j 4 I 3 I 2 I 1 1 L(. SIO IAO s GENERAL NOTES IS. ENGINEERING D FOR ARCHITECTURE �--;:I TISCo or; � sun uc rc.Pmmr. ssrn as x D 5757 Blue Lagoon Dr. 61 11I ea m.� 8610400 5 >� 40 9.NI SYS IS SA1.01-PLAIDI_ _ MleFL 00128 Phone:305.288.6553 F i�; .cvmA°""04-`""m Eaa.1455458°.)884504444441400/ ,OK:305.288.6695 I =— 04 11 sor68n¢r t18 n1Nx rrte.• .Ho-enpinears.0om y �i °°)MA...ivnec FPNOEz uwu w a xvoR°cam` EB i0000015 _.. ..,a 01804060404700805008.7040840041 m 10408.0.�w,l 012,5,1A 00 TIDBm..mlaABs.M..eA ME llEN' ,11.44.MI.;orIF+L e.A+,°51 w.°,L 8000 LIN Mr. .sm --a°°-- ..Ps ...--- SPECIFICATIONS 1122211EISSEEff SCAM WS-...us' Y ea"i°('a. LICK °.aws.�rz CC 8040:.01 ILE mac i..spys ...s'B°E1• s. I.laceat A,2..mIpm ...Pa-_•WM,u1.WI-aa4a85m.rw VW LS SONGS Man., U C eslbw m!'._>•1 ns. CABLING NOTES C: CO O 04 2 si II1�I aPUD k�..410ruoi`:>aii ItS S▪ ."%ltiT4=1.7UPSOLLUE RR LLICO l mu i R.*m M. a W o m .II1.�1�II,I=T,�,�li WS SOC.SPICE IS KW.._ .wro. ,,,TN n.rm ter. U w <A =IMF' sq.,.11 MP,I..,.aEom rN P... (7 E l�3.L+N■wi� • AU,... °n"`e 040 •f = :>m ',?...S.."...l.w e,rTA.r9�+.rle.m.@.ara.ALeNzn .m a « Q 1fn�0 3l li hlirrl V u NOTES 1600-2000 AMPS f emeramm FRJM El FVATM ::N FRONT VIEW300 SFRIF$ S1QE1aEN REAR'AEW LOIS fel 1 r,u u x[04¢ISM W m L. SOO. (R 855.1.08-c5 rrA.vAw.: MTERIOR VIRW 1p�p ar,.P. (mu ro ED,UA elm ILiu%rr 4lgfc om wmo'wrtw.:7 . A km MR MON sr..,800000 rat 00 TO W 15 SONG.10L16 an me. B ONE UNE DIAGRAMS- nm tem, P. °lam°°ne�,,��x e,�_ R NN 040 D03w., _7 y'- CIRCUIT EREAKEP:ovum,' 52U - °t .'N1 LL.00.0,,OST oar, ' r S100444 a.N,.w ,m, 0811.,0 Ej___.4 B� O SWIM MAT UV SL.I.M. /3\ ( 1`]. C . GyENERATOR SET t 'im nP L $ •. rO, ` n ! PLAN VFW' N * .0 —�``^\ 0/6 60 PAW. Ma0Uel 60160eeo.P.E .... /"" __ ___�,__ //' B e® FlontlS license M83096 BED? �°�� O� U rn ��am ;,.;w °Yap-.y A 2 m L.I..N./aiee A 5104) .......In Ir'''. r,= I 5� W. (.>P9� D I-I A ( 1T IN54.a. ua.o I. mm � 10°�" 1.4.-moa.BO Ma . 5» olui, �..: 3 L.L �// . - 1--- W y e (WTH SOLID NEUTRAL) (4/17H SWITCHED/OVERLAPFIIJG NEUTRAL) --� A„A ��e� —�," 75^:r4.57174.01.1 D1 �. ��� _ o o o 0 oI d9C® .. -4e u I" F. 8• 1 7 I 6 I 5' * 4 I 3 I 2 1 w 1 Pra®N.. 613002 s.. _ _ _ _ _ 03J7-08 1. ..-.— __ SUPPLIED NMI STANDARD MECHANICAL(SCREW TYPE)LUGS ON THE L0504 EMERGENCY BUS STABS ONE 01 LUG PERPHASE AND NEUTRAL EACHSU0ABLE FOR CONNECTION OF THREE SETS OF CABLES 00.n6Y. TLC UP TO MOM CWALTLC 5 wme sm. 08'=1'-0° 0. GROUND LUGS ARE PROVIDED STANDARD AS FOLLOWS:010RO.=ANG CU/AL GABLE 01 Orawino T. 03 CIRCUIT BREAKER REM sxu m AUTOMATIC 1. 1W%RATED MOLDED CASE CIRCUIT BREAKER BOOAFSOORTSOLID STATE ELECTRONIC TRIP, a TRANSFER SWITCH a DIAGRAM M on a E-104 I//1"‹,:- TAW POWER SYSTEMS, INC. t 1500 NW 15th Ave Pompano Beach, FL 33069 TA Ph.: (954) 977-0202 x1759 (800) 876-0990 Fax: (954) 977-9249 l/a Kohler Generator Systems Distributors KOHLER POWER SYSTEMS DISTRIBUTOR FOR ALABAMA, SOUTH GEORGIA,FLORIDA, LOUISIANA AND MISSISSIPPI Date: August 8, 2018 Offer No: P1808-0106 Contact: John Potts Contact Cell#: (954)-234-4226 Project: City of Miami Beach—Property Management One New KOHLER Model 500REOZJ, EPA Certified Diesel Generator Set, 500KW, @ 0.8 PF, 60 Hz, 3 Phase, UL 2200, 277/480 Volt with the following: CONTROLLER: ADDITIONAL ACCESSORIES: APM402 Certified Factory Test @ 0.8 P.F. Controller meets NFPA 110 3 Engine, Generator Parts, Maintenance Manuals 1 Electronic Manual ENCLOSURE: Vibration Isolators: Internal Aluminum Sound Enclosure 5 Year Comprehensive Warranty 181 MPH Wind Load Rated Critical Silencer SUPPLIED BY OTHERS COOLING: New Fuel—First Fill of New Tank Unit Mounted Radiator Installation Block Heater, 120 Volt Local and State Permitting by Others All Infrared, 3rd Party and NETA Testing if Required FUEL SYSTEM: Flexible Fuel Lines Sub-base Fuel Tank, 1,700 Gallon, UL142 Listed FDEP Package TOTAL NET LOT: $103,950.00 Fuel Water Separator GENERATOR ACCESSORIES (Electrical): ESTIMATED LEAD TIME: Line Circuit Breaker, 3 Pole, 100 % Rated 16 to 18 weeks after release of the order. This Qty(1)800 Amps, Electronic, estimated lead time is subject to change daily due to ENGINE ELECTRICAL ACCESSORIES: availability Battery Rack and Cables F.O.B. FACTORY, FREIGHT ALLOWED TO JOB SITE Starting Battery, Lead Acid Battery Charger: 10 Amps SALES TAX NOT INCLUDED CONTROLLER ACCESSORIES LOOSE: Remote Emergency Stop, Break Glass Regards, Remote Annunciator Panel TAW Power Systems, Inc. AUTOMATIC TRANSFER SWITCH: John Potts Qty(1) Kohler Model KEP-DMTC-0800-NK Senior Sales Engineer 208 Volt, 3 Ph., 3 Pole, 800A, NEMA 3R, Service Entrance Rated OFFER VALID FOR 30 DAYS FROM THIS OFFER DATE (LISTED ABOVE) Page 780 of 1648 EXCEPTIONS/CLARIFICATIONS/NOTES: (OFFER ACCEPTANCE BELOW) Delivery, start up, and load testing are quoted as during normal business hours. If after hour, weekend, or holiday work hours are required, the Contractor will be responsible COMPANY for the overtime differential unless otherwise noted. AUTHORIZED SIGNATURE OFFER BASED UPON: TITLE • Drawing E-101 PRINT NAME DATE NOTE: TAW's STANDARD TERMS and CONDITIONS apply to all TERMS & CONDITIONS ACKNOWLEDGED: offers for purchase and any purchase orders accepted by TAW.You may find a copy under the terms and conditions section at TAWINC.com or please contact our office at 800-456-9449 and we will forward you a copy.TAW will transmit a written delivery schedule based on the INITIAL manufacturer's confirmation,approximately fifteen(15)days after product release. Also included will be the related progress invoice values based on material shipments. All TAW offers,plans,specifications,and technical drawings are copyrighted works and contain proprietary know-how of TAW,and Buyer has no right to reproduce,distribute or publish copies of TAW's copyrighted works or to create derivative works of TAW's copyrighted works without the express written permission of an authorized representative of TAW. Page 781 of 1648