Resolution 80-16373 a.
RESOLUTION NO. 80-16373
A RESOLUTION OF THE CITY COMMISSION OF THE CITY OF MIAMI BEACH,
FLORIDA, APPROVING AND ADOPTING THE PROPERTY REHABILITATION
STANDARDS OF THE COMMUNITY DEVELOPMENT MULTI-FAMILY REHABILITATION
PROGRAM.
WHEREAS, the City of Miami Beach has included in its Community
Development Block Grant Program application, a program designed to assist in
the rehabilitation of multi-unit residential properties, and
WHEREAS, it is required by the U.S. Department of Housing and Urban
Development that property rehabilitation standards be adopted by the City to
assure uniform improvements to dwelling units assisted by the Rehabilitation
Program, and
WHEREAS, the City Commission deems it to be in the best interests
for the health and safety of the citizens of Miami Beach to improve the quality
of the housing stock to be assisted by the Rehabilitation Program; and
WHEREAS, the Property Rehabilitation Standards, dated March, 1979
are attached hereto and made a part hereof;
NOW, THEREFORE BE IT DULY RESOLVED BY THE CITY COMMISSION OF THE CITY
OF MIAMI BEACH, FLORIDA, that the Property Rehabilitation Standards of the Com-
munity Development Multi-Family Rehabilitation Program be and they are hereby
approved and adopted.
PASSED and ADOPTED this 3rd day of September, 1980.
\\\._)\
\)\--
.
ayor
ATTEST:
City Clerk
FORM APPROVED
LE AL DEPT.
By
Date Aic.. 2,E. OM
. 7 0 .
A. --
otes,/ 74m seams ,,,,,,77.„4,4a2.4_
,
r4
FLORIDA,v.,
3 3 1 3 9
3��
.., �,C*'
(......._Coa►,o no "VAC.4TIONLAND U. S. A.f _.. ib:
�'7,QC.H w\A?
OFFICE OF THE CITY MANAGER CITY HALL
HAROLD T.TOAL 1700 CONVENTION CENTER DRIVE
TELEPHONE: 673-7010
CITY MANAGER
COMMISSION MEMORANDUM NO. _g__Vg_rar*
DATE: SEPTEMBER 3, 1980
TO: Mayor Murray eyerson and
ers of tIr 'ti .Commiigsion
FROM: o d . Toa
City Manager
SUBJECT: COMMUNITY DEVELOPMENT PROPERTY REHABILITATION STANDARDS
At the present time HUD is completing review of the City's $2,437,000
application for 6th Year Community Development Block Grant Funds.
One of the programs which is scheduled to be implemented during the coming
fiscal year is a City sponsored Multi-Family Rehabilitation Program. These
property rehabilitation standards have been prepared to insure that projects
assisted through this program will meet design and construction standards
necessary to assure that the housing provided is liveable, healthful, safe and
physically sound.
In order to complete processing of our 6th Year application, HUD has requested
that we seek City Commission approval of these Standards at this time. Once
approval of funding has been given we will be returning to the Commission to
seek approval of the Policies, Methods of Evaluating and Selecting Proposals,
and Operating Methodology for implementing the proposed Multi-Family
Rehabilitation Program.
ADMINISTRATION RECOMMENDATION
In order to facilitate the completion of HUD processing of the City's
$2,437,000 application for 6th Year Community Development Block Grant Funds,
the Administration recommends that the City Commission adopt a resolution
approving the Community Development Property Rehabilitation Standards.
HTT/MSL/kt
b
• 42
/?
AGENDA �r
ITEM (((
fDATE
— 3 — �
COMMUNITY DEVELOPMENT
PROPERTY REHABILITATION STANDARDS ..
CITY OF MIAMI BEACH
March, 1979 3l / 9.80
� ,,
_ ,.. f`—
_....
eel 06 ve,a, eedd .., .
,,, _,, ,,4-- ' '
r P!• E• F L O R I D A 3 3 1 3 9 s ` 31
1 f cti.
, -....-/-----.-0 i f ._,,,, v
I*
nr ACID *• "VAC.4 TIONLANL) U. S. A."
'PSN ..
OFFICE OF THE CITY MANAGER CITY HALL
HAROLD T.TOAL 1700 CONVENTION CENTER DRIVE
CITY MANAGER TELEPHONE: 673-7010
COMMISSION MEMORANDUM NO. "Yew.'
DATE: SEPTEMBER 3, 1980
TO: Mayor Murray eyerson and
ers ofe 't \ComZon
FROM: o d . Toal
City
City Manager
SUBJECT: COMMUNITY DEVELOPMENT PROPERTY REHABILITATION STANDARDS
At the present time HUD is completing review of the City's $2,437,000
application for 6th Year Community Development Block Grant Funds.
One of the programs which is scheduled to be implemented during the coming
fiscal year is a City sponsored Multi-Family Rehabilitation Program. These
property rehabilitation standards have been prepared to insure that projects
assisted through this program will meet design and construction standards
necessary to assure that the housing provided is liveable, healthful, safe and
physically sound.
In order to complete processing of our 6th Year application, HUD has requested
that we seek City Commission approval of these Standards at this time. Once
approval of funding has been given we will be returning to the Commission to
seek approval of the Policies, Methods of Evaluating and Selecting Proposals,
and Operating Methodology for implementing the proposed Multi-Family
Rehabilitation Program.
ADMINISTRATION RECOMMENDATION
In order to facilitate the completion of HUD processing of the City's
$2,437,000 application for 6th Year Community Development Block Grant Funds,
the Administration recommends that the City Commission adopt a resolution
approving the Community Development Property Rehabilitation Standards.
HTT/MSL/kt
&__4
AGENDA AA-
4•5 •
ITEM /e: (((
DATE 9.....3
RESOLUTION NO. 80-16373
A RESOLUTION OF THE CITY COMMISSION OF THE CITY OF MIAMI BEACH,
FLORIDA, APPROVING AND ADOPTING THE PROPERTY REHABILITATION
STANDARDS OF THE COMMUNITY DEVELOPMENT, MULTI-FAMILY REHABILITATION
PROGRAM.
WHEREAS, the City of Miami Beach has included in its Community
Development Block Grant Program application, a program designed to assist in
the rehabilitation of multi-unit residential properties, and
WHEREAS, it is required by the U.S. Department of Housing and Urban
Development that property rehabilitation standards be adopted by the City to
assure uniform improvements to dwelling units assisted by the Rehabilitation
Program, and
WHEREAS, the City Commission deems it to be in the best interests
for the health and safety of the citizens of Miami Beach to improve the quality
of the housing stock to be assisted by the Rehabilitation Program; and
WHEREAS, the Property Rehabilitation Standards, dated March, 1979
are attached hereto and made a part hereof;
NOW, THEREFORE BE IT DULY RESOLVED BY THE CITY COMMISSION OF THE CITY
OF MIAMI BEACH, FLORIDA, that the Property Rehabilitation Standards of the Com-
munity Development Multi-Family Rehabilitation Program be and they are hereby
approved and adopted.
PASSED and ADOPTED this 3rd day of September, 1980.
\\\A
ayor
ATTEST:
City C4rk
FORM APPROVED
LE AL DEPT.
By -- I�
pate z Z ( ��
. ' s .
PROPERTY REHABILITATION STANDARDS
CITY OF MIAMI BEACH
INTRODUCTORY STATEMENT
PURPOSE AND INTENT
These physical guidelines for the rehabilitation of existing
multi-family properties have been developed to provide minimum
design and construction criteria. The provisions are intended
to serve as an important aid in carrying out the objectives of
Federal and local programs for neglected and run-down properties.
These objectives seek the large scale physical, social and eco-
nomic regeneration of neighborhoods which have, in general,
deteriorated seriously.
The purpose and intent of the guidelines are threefold:
1. To assure improved housing that is liveable, healthful,
safe and physically sound, and at the same time is low
enough in cost for present neighborhood residents to
afford.
2. To provide an acceptable minimum level for residential
rehabilitation based on performance, which has maxi-
mum flexibility to meet local conditions, and
3. To encourage innovation and improved technology which
give promise of reducing construction costs.
. •
TABLE OF CONTENTS
PARAGRAPH PAGE
INTRODUCTORY STATEMENT
CHAPTER I - DEFINITIONS
101 General 1
102 Definitions 2-5
CHAPTER II - GENERAL ACCEPTABILITY CRITERIA
201 Local Codes and Regulations 6
202 Existing Remedies Preserved 6-7
203 Provision to Waive Requirements of the
Standards 7
204 Service and Facilities 7
205 Access 7
205-1 Access to the Property 7
205-2 Access to the Building 7
205-3 Access to Each Living Unit 7
206 Determining the Number of Living Units 8
207 Partial Non-Residential Use 8
208 Dilapidated or Blighted Structures 8
209 Site Conditions 8
CHAPTER III - SITE CRITERIA
301 Objective 9
302 Outdoor Environment 9
302-1 Open Space 9
302-2 Outdoor Lighting 10
303 Site Improvements 10
303-1 Drainage 10
303-2 Walks 10
303-3 Parking Spaces 11
303-4 Landscaping 11
304 Vegetation 11
305 Architecturally or Historically Significant
Structures 11
CHAPTER IV - BUILDING REHABILITATION AND PLANNING
401 Objective 12
402 Required Provisions 12
403 Cellar or Basement Occupancies Prohibited 12
404 Management and Maintenance Space 12
405 Space Standards 12
i
• ' •
TABLE OF CONTENTS - Continued
PARAGRAPH PAGE
406 Room Sizes 13
407 Dining Facilities 13
408 Bath Facilities 14
409 Kitchen Facilities 14-15
410 Kitchen Storage 15
411 General Storage and Closets 15
412 Privacy and Arrangement 15-16
413 Ceiling Heights 16
414 Space and Laundry Facilities 16
415 Doors and Access Openings 16
415-1 Exterior Doors 17
415-2 Interior Doors 17
415-3 Attic and Basementless Spaces 17
416 Stairways 17
416-1 Existing Stairways 17
416-2 New Stairways 18
417 Guard Rails 18
418 Handrails and Railings 18
419 Railings at Stairs 18
420 Light and Ventilation 18
420-1 General 18
420-2 Habitable Rooms 19
420-3 Bathroom and Toilet Compartments 19
420-4 Public Spaces 19
420-5 Public Entrance Spaces 19
420-6 Ventilation of Utility Spaces 19
420-7 Ventilation of Structural Spaces 19
421 Elevators 20
422 Trash and Garbage Disposal 20
423 Noise Control 20-21
CHAPTER V - FIRE PROTECTION
501 Objective 22
502 General 22
503 Required Means of Egress 22
504 Travel Distance 22-23
505 Arrangement of Exits 23
506 Stairways 23
507 Guards and Rails 23
ii
.
TABLE OF CONTENTS - Continued
PARAGRAPH PAGE
508 Walls , Floor and Ceiling Construction 24
509 Enclosure of Vertical Openings 24
510 Transoms 24
511 Firewall , Party or Lot Line Wall 24
512 Roof Coverings 24
513 Fire Alarm Systems 25
514 Sprinkler System 25
515 Interior Finish 25-26
CHAPTER VI - MATERIALS AND PRODUCTS
601 Objective 27
602 General 27
603 Quality of Materials and Products 27
604 Standards for Materials and Products 27
605 Referenced Standards 27
606 Labeling 27
CHAPTER VII - CONSTRUCTION
701 Objective 28
702 Structural Soundness 28
703 Construction Performance 28
704 Safety and Health Regulations 28
705 Foundations and Exterior Walls 29
705-1 General 29
706 Partitions, Columns and Posts 29
707 Floor Construction 29
707-1 General 29
707-2 Basement and Cellar Floors 29
708 Chimneys and Vents 29
709 Protection from Rodents, Termites
or Other Infestation 30
710 Inspection and Correction 30
711 Termite and Decay Damage 30
712 Decay 31
713 Insulation 31
CHAPTER VIII - EXTERIOR AND INTERIOR FINISHES
801 Objective 32
802 Exterior 32
803 Roof Coverings 32
803-1 General 32-33
iii
TABLE OF CONTENTS - Continued
PARAGRAPH PAGE
803-2 Gutters and Downspouts 33
803-3 Flashing 33
804 Doors , Windows and Other Openings 33
804-1 Door Performance - General 33
804-2 Exterior Doors (Installation) 33
804-3 Weatherstripping 34
804-4 Miscellaneous 34
805 Windows 34
805-1 Installation 34
805-2 Weatherstripping 34
805-3 Window Frame Anchorage 34
806 Screens 34
807 Hardware and Security 34-35
808 Interior Wall and Ceiling Finishes 35
808-1 General 35
808-2 Conditions of Use 35
809 Finish Materials 36
809-1 General 36
810 Finish Floors 36
811 Painting and Decoration 36
CHAPTER IX - MECHANICAL EQUIPMENT
901 Objective 37
902 General 37
903 Mechanical Ventilation and Air Conditioning 37
904 Heating, Air 37-38
905 Heating , Water 38
906 Capacities 38
907 Heating Capacity Chart 39
CHAPTER X - PLUMBING
1001 General 40
1002 Condition of Existing Plumbing 40
1003 New Plumbing Work 40
CHAPTER XI - ELECTRICAL
1101 General 41
1102 Existing Wiring and Equipment 41
1103 New Electrical Work 41
iv
CHAPTER I
DEFINITIONS
101 GENERAL
Definitions given in this chapter are included to
provide a basis of understanding the meaning of these
terms, phrases and their derivatives wherever used in
these standards. These definitions have general con-
sistency with those used throughout the building
industry, but are directed to the specific needs of
rehabilitation, as covered in this document. None are
intended to nullify the provisions of any local code,
but are furnished to provide maximum understanding of
these guidelines.
In construing the provisions of this chapter, where the
context will permit and no definition is provided in
Chapter 4 of the South Florida Building Code and Section
3, Definitions, of the Zoning Ordinance, No. 1891, of
the City of Miami Beach shall apply. The following words
and phrases, when used in this chapter, shall have the
meanings ascribed to them in this section.
102 DEFINITIONS
APARTMENT: One or more rooms occupied as a home or resi-
dence, for an individual, family or household, the exis-
tence of kitchen sink accommodations, cooking facilities,
and bathroom facilities within shall be sufficient to
classify such as an apartment.
APARTMENT BUILDING: A building with or without resi-
dent supervision occupied or intended to be occupied
by more than two families living separately and with
separate cooking facilities in each unit.
APARTMENT HOTEL: A building, usually under resident
supervision, made up of three or more apartment units,
arranged with common corridors, and exits and maintain-
ing an inner lobby or foyer, through which persons pass
for access to the apartment.
APPROVED: Approved by the Director of the Economic
Development Department or his authorized representative.
COMMERCIAL BUILDINGS: All stores, offices, garages, restau-
rants, theatres, clinics, nursing homes, or other similar
facilities or any parts of the building used or intended to
be used to serve, entertain or perform any service and/or
business to or for the public. The term "Commercial Build-
ing" shall be construed as if followed by the phrase or
"Any Part Thereof" .
-1-
.
COMMERCIAL UNIT: Any room or group of rooms located
within a building forming a single unit which will be
used or intended to be used, for any use customarily
in Commercial Buildings.
CONDOMINIUM: Defined by Chapter 711, Florida Statues.
CO-OPERATIVE APARTMENT BUILDING: (Co-op) Defined by
Chapter 711, Florida Statues.
COURT: Is an open, unoccupied space, bounded on two or
more sides by the walls of the building. An inner court
is a court entirely within the exterior walls of a build-
ing. All other courts are outer courts.
CRAWL SPACE: See Basementless Space.
DINING ROOM: Any building or part thereof, or any room
or part thereof , which is primarily used for the dispens-
ing and servicing of food.
DWELLINGS: A building designed or used as the living
quarters for one or more families.
DETACHED: A dwelling which is completely surrounded
by permanent open spaces.
SEMI-DETACHED: A dwelling, one side wall of which
is a party or lot-line wall.
ROW: A dwelling , the walls on two sides of which are
party or lot-line walls.
ROW-END: Same as Semi-Detached.
MULTI-FAMILY: A building containing three or more
living units for families living independently of
each other.
ECONOMICALLY REPAIRABLE: When the cost of repairs or
alterations of accessory structures or the dilapidated
portions of existing properties exceed 50% the costs of
replacing the same item with like, kind and quality, or
the item serves no useful purpose, the item shall be
considered not economically repairable and shall be
removed. (see Section 207)
FAMILY: Is any number of persons living together under
one head as a single housekeeping unit, whether related
to each other legally or not; and shall be deemed to
include servants, but shall not include paying guests.
FAMILY UNIT: See living unit.
FOUNDATION: Construction, below or partly below grade,
which provides support for exterior walls or other
structural parts of the building.
-2-
GRADE: The average elevation of the ground, paved or
unpaved, adjoining a building or structure, at the center
of each exterior wall line.
HABITABLE AREA: Shall mean two (2) or more habitable rooms .
HABITABLE ROOM: A room in a residential unit used for
living, sleeping, eating or cooking, but excluding baths,
toilets, storage spaces or corridors.
HOT WATER: Shall mean water heated by a system capable of
supplying one hundred forty (140) degrees Fahrenheit water
temperature in the amounts of sixteen (16) gallons per bed-
room per three (3) hours .
INFESTATION: Shall mean the presence of any insects, rodents ,
vermin, or other pests.
JOISTS : Are secondary horizontal supporting members in
floor, ceilings or roof construction.
KITCHEN: Space, 50 sq. ft. or more in area, used for cook-
ing and preparation of food.
KITCHENETTE: Space, less than 50 sq. ft. in area, used for
cooking and preparation of food.
LISTED AND LISTING: Terms referring to equipment which is
shown in a list published by an approved testing agency.
LIVING UNIT: A residential unit providing complete, inde-
pendent living facilities for one family including permanent
provisions for living, sleeping, eating, cooking and sani-
tation.
MOISTURE PROTECTION: Safe guarding living units against
the penetration of passage of water, water vapor and dampness.
NEW CONSTRUCTION: (a) Proposed construction or other new
structures erected on cleared or vacant land; or (b) new
additions to an existing building which enlarges the floor
area or height of the building.
PROPERTY: A lot or plot, including all buildings and improve-
ments thereon.
REHABILITATION: The restoration of a reuseable single or
group of structures which overcomes deterioration and pro-
vides a satisfactorily improved physical condition for resi-
dential purposes .
REHABILITATION CONSTRUCTION: (a) Improvement of a
property to decent, safe and sanitary condition from
a condition requiring more than routine or minor repairs
-3-
•
•
or improvements such as (1) all repairs to or replace-
ment of present elements of an existing building, such
as windows, stairs, walls, floors , roof, plumbing, wir-
ing, heating or other equipment. (2) Rearrangement of
rooms by the relocation of partitions or by the instal-
lation of new bathrooms and kitchens . (3) The general
replacement of the interior of a builidng. This replace-
ment may or may not include changes to structural ele-
ment such as floor systems, columns or load bearing
interior walls. (b) Rehabilitation construction may vary
in degree from gutting and extensive reconstruction to
cosmetic improvements coupled with cure of an accumula-
tion of deferred maintenance. Cosmetic improvements
alone can qualify under this definition if the structure
currently complies with all of the other provisions of
the standards . (c) Rehabilitation construction also
includes renovation, alteration or remodeling for the
conversion or adaptation of structurally sound property
to the design and condition required for use in these
standards. (e.g. , conversion of a hotel to an apartment
building) .
SHALL: Indicates a mandatory requirement.
SHOULD: Indicates minimum good practice but is not manda-
tory under the provisions of this document.
SPACE HEATER: (Room Heat) An above the floor self-contained
device for furnishing heated air, through openings in its
casing, directly into the space in which the device is
located or immediately adjacent to it. The device may be
freestanding or recessed in a wall or partition.
STRUCTURE: Anything constructed or erected, the use of
which requires permanent location on the ground or attached
to something having a permanent location on the ground.
Among other things, structures include buildings, walls,
fences, signs and screen enclosures.
STRUCTURAL ALTERATION: Any change, except for repair
or replacement, in the supporting members of a building
or structure, such as bearing walls , columns, floor or
roof joists, beams or girders.
SUBSTANDARD BUILDING: Any building or portion thereof in
which there may exist physical conditions serious enough to
endanger the life, limb, health, property, safety or welfare
of the occupants or of the public.
SUITABLE FOR REHABILITATION: A structure or portion thereof
because of its age, design or present deteriorated condition
indicates a definite need for continued maintenance. There
should exist a need for correcting all present and incipient
violations, and for putting the property in generally good
and readily maintainable condition with the necessary faci-
lities in good working order.
-4-
TOILET ROOM: Enclosed space, containing one or more water
closets and a lavatory.
VENTILATION:
MECHANICAL: Supply and removal of air by power-driven
devices .
NATURAL: Ventilation by openings to outside air through
windows, doors or other openings.
WALL:
BEARING WALL: A wall which supports any vertical load
in addition to its own weight.
CURTAIN WALL: A non-bearing exterior wall supported by
the structural framework of the building.
FACED WALL: A wall in which the masonry facing and
backing are so bonded as to exert a common action under
load.
FIRE WALL: A continuous wall from foundation to roof
with designated qualities of fire resistance and struc-
tural stability which subdivides a building into fire
areas, and which resists the spread of fire.
NON-BEARING WALL: A wall which supports no vertical
load other than its own weight.
PARAPET WALL: That part of any wall entirely above the
roof.
PARTY WALL: A wall used jointly by two parties under
easement, erected upon a line separating two parcels of
land, each of which is a separate real estate entity.
RETAINING WALL: Any wall used to resist lateral dis-
placement of any material.
-5-
•
•
CHAPTER II
GENERAL ACCEPTABILITY CRITERIA
201 LOCAL CODES AND REGULATIONS
All properties shall, comply with the standards set forth
in all applicable statutes , codes, and ordinances, as
amended from time to time, relating to the use, maintenance,
facilities, and occupancy of property, including but not
limited to the building, plumbing, heating, electrical, and
housing codes. These code standards are hereby incorporated
by reference and made a part of these Property Rehabilitation
Standards .
When the local code, regulation or requirement permits lower
standards than required herein, these Property Rehabilitation
Standards shall apply. In the event the local code, regu-
lation or requirement precludes compliance with these stand-
ards , the property may be ineligible unless the intent set
forth herein is fully attained by the alternate means pro-
posed or variances are received from the appropriate author-
ities .
These standards shall not be construed as relieving the
builder of his responsibility for compliance with local
ordinances, codes and regulations including established
requirements of a health authority having jurisdiction.
These standards are not intended to replace, modify, super-
sede or diminish the standards established for the construc-
tion, repair, alteration or use of buildings, equipment of
facilities by the South Florida Building Code. In any case
where any provision of these standards is found to be in
conflict with a material and controlling provision of the
Comprehensive Zoning Ordinance, the South Florida Building
Code, any other municipal ordinance, code or regulation or
any rules or regulations of the Florida State Board of Health,
or in the case of Section 8 , Substantial Rehabilitation
projects, HUD Handbook 4940 . 4 Minimum Design Standards for
Rehabilitation for Residential Properties, the provision
which established the highest standard shall prevail.
202 EXISTING REMEDIES PRESERVED
Nothing in these Property Rehabilitation Standards shall be
deemed to abolish or impair any existing remedies relating
to the removal of or demolition of any buildings which are
deemed to be dangerous , unsafe or unsanitary. These stand-
ards shall not affect violations of any other municipal
ordinance, code or regulations existing prior to the effect-
ive date of these standards, and such violations shall be
-6-
•
governed and shall continue to be punished to the full
extent of the law under the provisions of those ordinances,
codes or regulations in effect at the time the violation
was committed.
203 PROVISIONS TO WAIVE REQUIREMENTS OF THE PROPERTY REHABILI-
TATION STANDARDS
Where the physical design of a structure does not permit
exact compliance with the mandatory requirements of the
Property Rehabilitation Standards, or when in the opinion
of the authority responsibility for enforcing the provisions
of the Property Rehabilitation Standards , alternative methods
can be employed which will achieve the intent of the stan-
dards, the authority shall have the power to grant a waiver
of the provisions. Such waiver shall only be granted in
instances where deviations from the Property Rehabilitation
Standards are of a minor character, and it appears that sub-
stantial compliance will be made by the applicant, and that
the granting of a waiver would not be detrimental to the
occupants or to the public ' s health, safety and welfare.
204 SERVICE AND FACILITIES
Utilities and other facilities shall be independent for the
property without dependence upon other properties . All
utilities necessary for normal occupancy of a living unit
shall be provided for each property and each living unit.
This may include increasing or renewing water and gas lines
and the electrical service for a more efficient and safe
system.
205 ACCESS
205-1 Access to the Property
Each property should be provided with emergency vehicular
access to and from the property by an abutting public or
private street. Private streets should be protected by a
permanent easement.
205-2 Access to the Building
Walks and steps shall be provided for all weather access to
the building and constructed so as to provide safety, rea-
sonable durability and economy of maintenance.
205-3 Access to Each Living Unit
Access to each living unit shall be provided without passing
through any other living unit.
-7-
• •
206 DETERMINING THE NUMBER OF LIVING UNITS
Each dwelling or portions thereof providing complete living
facilities for one family shall be counted as a living unit.
Rehabilitation of housing for the elderly projects shall
have living facilities appropriate to their needs.
A room or group of rooms containing complete living facili-
ties , such as an apartment of a janitor or caretaker shall
be counted as a separate living unit.
207 PARTIAL NON-RESIDENTIAL USE
Any space or feature included in the property from which
income is anticipated apart from the rental of living units
is termed non-residential or commercial use.
Non-residential use shall be of a character which is com-
patible with the residential character of the property or
project. The extent of non-residential use shall be deter-
mined by the proper local authority in relation to the broad
planning needs of the occupants and neighborhood.
208 DILAPIDATED OR BLIGHTED STRUCTURES
All dilapidated portions of existing properties or blighted
structures which are not economically repairable shall be
removed.
All exterior appurtenances or accessory structures which
serve no useful purpose, or those in a deteriorated con-
dition which are not economically repairable, shall be
removed. Such structures include porches, terraces,
entrance platforms, garages , carports, walls, fences , and
miscellaneous sheds.
209 SITE CONDITIONS
The property should not be subject to hazards such as
objectionable smoke, noxious odors, unusual noise, or the
probability of flooding.
Essential community facilities and services , such as employ-
ment centers, shopping centers, schools, recreation areas ,
and police and fire protection should be reasonably acces-
sible to the site or group of sites making up the project.
-8-
. •
CHAPTER III
SITE CRITERIA
301 OBJECTIVE
To develop the individual site or group of sites so that
obsolensence is overcome, and the development is approp-
riate and an asset to the neighborhood in which it is
located.
302 OUTDOOR ENVIRONMENT
In the rehabilitation of a project, consideration shall be
given to the needs of the residents for non-vehicular open
space for active and inactive recreation. Adequate night
lighting for the safe use of parking areas, walks, and
steps shall be provided or arrangements made for its pro-
vision by the property owner.
302-1 OPEN SPACE
In small dwellings there should be open space provided for
laundry drying, gardening and outdoor living, located ad-
jacent to the building.
Deficient yard dimensions to property lines of existing
buildings should not be made a reason for rejection.
Courts
1. Outer courts should have at minimum dimension of
eight feet if windows of habitable rooms occur in
walls opposite each other and serve separate living
units or buildings.
2. The distance between building walls of outer courts
under other conditions should not be less than five
feet.
3 . Inner courts should have at least 50 square feet
area and minimum dimensions as for outer courts.
4 . Covered light shafts, or open shafts of less than
40 square feet area, should not be the only means
of providing ventilation to bedrooms or living rooms.
Walls or fences should be provided when necessary to insure
privacy to occupants and/or protection of open spaces from
pedestrian or vehicular traffic.
-9-
•
302-2 OUTDOOR LIGHTING
All public areas where pedestrian use can be anticipated
after sunset should be adequately lighted for security
purposes where arrangements for permanent maintenance
and operation can be assured. Minimum levels of illumi-
nation in footcandles for the following areas shall be:
Building entrances 4 , commercial area walks and heavy use
walks 2 , steps and hazardous areas 2 , parking areas 1,
other public walks and common areas for pedestrian use 2 .
Lighting should be time controlled to come on at sunset
and off at sunrise.
303 SITE IMPROVEMENTS
The open space of each property should provide (a) for the
immediate diversion of water away from buildings and dis-
posal from the lot, (b) prevent soil saturation detrimental
to structures and lot use, and (c) where needed, appropriate
paved walks, parking areas, driveways, exterior steps and
landscaping.
303-1 DRAINAGE
GENERAL
Surface and subsurface drainage systems shall be provided,
as appropriate, for collection and disposal of storm drain-
age and subsurface water. These systems shall provide for
the safety and convenience of occupants, protection of
dwellings, other improvements and usable lot areas from
water damage, flooding, and erosion.
303-2 WALKS
Walks shall be provided for safe convenient access to all
dwellings and for safe pedestrian circulation throughout a
development between facilities and locations where major
need for pedestrian access can be anticipated.
Walks and step treads should have a slip resistant surface.
Entrance walks shall extend from the front entrances of
buildings to another acceptable paved way.
Service walks should extend from service entrances to
entrance walks or other ways. They may be omitted where
entrance walks serve acceptably as service entrances.
Minimum walk widths, for walk-up apartments :
a. Principal entrance walk 4 ft.
b. Minor walk 3 ft.
c. Service walk 3 ft.
-10-
Minimum walk width, for elevator apartment buildings:
a. Principal entrance walk 6 ft.
b. Minor walk 3 ft.
c. Service walk 3 ft.
303-3 PARKING SPACES
The number of parking spaces required for each living
unit shall be based on the local Zoning Ordinance. When
space is available, parking areas should be provided.
303-4 LANDSCAPING
Landscaping, including sprinkler systems, is an eligible
expense, appropriate to the needs of the building; however,
should not exceed ten percent of the rehabilitation costs
for the building. All rehabilitated sites should be ade-
quately landscaped as determined by the appropriate authority.
304 VEGETATION
Fences, bumper stops , or other equally effective barriers
should be provided which will protect the ground area
beneath the branches of preserved trees and other areas
of preserved natural vegetation from vehicular intrusion
in areas where vehicular intrusion may be anticipated.
305 ARCHITECTURALLY OR HISTORICALLY SIGNIFICANT STRUCTURES
In the rehabilitation of older buildings, consideration
shall be given to architecturally or historically signifi-
cant structures. The rehabilitation of such structures
should be sensitive to identifiable architectural style
and every reasonable effort shall be made to insure that
the rehabilitation of the project will be compatible with
the surrounding environment.
-11-
CHAPTER IV
BUILDING REHABILITATION AND PLANNING
401 OBJECTIVE
Building rehabilitation and planning should provide for a
safe, secure, healthful, and attractive living facility
and environment suited to the social , economic, and recre-
ational needs of resident families and individuals . It
should provide for ease of circulation and housekeeping;
visual and auditory privacy; appropriate light and venti-
lation; fire and accident protection; economy in mainten-
ance and use of space; accessory services; and sanitation
facilities.
402 REQUIRED PROVISIONS
Each living unit shall have provisions for each of the
following :
1. A continuing supply of safe and potable water.
2. An adequate supply of domestic hot water.
3 . Sanitary facilities and a safe method of sewage
disposal.
4 . Heating adequate for healthful and comfortable
living conditions.
5 . Electricity for lighting and for equipment.
6. Adequate provisions for the collection of garbage
and trash and its sanitary storage pending removal .
403 CELLAR OR BASEMENT OCCUPANCIES PROHIBITED
No cellar or basement space shall be used as a habitable
room unless first approved by the appropriate authorities.
404 MANAGEMENT AND MAINTENANCE SPACE
Space should be provided commensurate with the number of
living units served. Also, space shall be provided for
necessary staff where social services are provided.
405 SPACE STANDARDS
Provide each living unit with space necessary for suitable
living, sleeping, cooking and dining accommodations, storage,
laundry and sanitary facilities; also, provide space of
such size and dimensions so as to permit placement of
furniture and essential equipment.
-12-
•
406 ROOM SIZES
The following room sizes are minimums. They do not super-
sede the Zoning Ordinance or local Minimum Housing Code
requirements .
Name of Minimum Area (Sq.Ft.) (2) Least
Space (1) O-BR LU 1&2 BR LU 3 or more BR LU Dimension (2)
LR NA 140 150 10 ' 0"
DR NA 80 100 7 ' 8"
K NA 50 60 5 ' 4"
K'ette 20 25 40 3 ' 6"
BR (double) NA 120 120 8 ' 8"
BR (single) NA 100 100 8 ' 0"
LR-DA NA 180 200 (3)
LR-DA-K NA 220 250 (3)
LR-DA-SL 220 NA NA (3)
LR-SL 190 NA NA (3)
K-DA 80 80 110 (3)
K'ette-DA 60 60 90 (3)
NOTES : (1) Abbreviations:
LU = Living Unit K'ette = Kitchenette
LR = Living Room BR = Bedroom
DR = Dining Room SL = Sleeping Area
DA = Dining Area 0-BR = No Separate Bedroom
K = Kitchen NA = Not Applicable
(2) Variations to these areas and dimensions may
be permitted when existing partitions pre-
clude precise compliance, and the available
area or dimensions do not hinder furniture
placement and the normal use of the space.
(3) The least dimension of each room function
applies, except for the overlap or double
use of space in combination rooms.
407 DINING FACILITIES
Each dwelling unit shall contain space for dining. This
area may be combined with the living room or kitchen, or
it may be a separate room.
Where the living-dining and kitchen areas are combined,
provisions should be made to screen the food preparation
area from the living room sitting area; the clear opening
between the kitchen and dining area should be at least
4 ft. 0 in.
-13-
408 BATH FACILITIES
Complete bathing and sanitary facilities shall be provided
within each living unit; they shall consist of a water-
closet, a tub or shower, and a lavatory. An adequate supply
of hot water to the tub or shower stall and lavatory, and
cold water shall be provided to all fixtures. Arrangement
of fixtures shall provide for the comfortable use of each
fixture and permit at least a 90 degree door swing. Wall
space shall be available for a mirror or medicine cabinet
and for towel bars .
Bathrooms shall be provided with the following accessories:
1. Grab-bar and soap dish at tub or shower.
2 . Shower curtain rod or enclosure at shower.
3. Soap dish at lavatory (soap dishes may be
integral with the fixture) .
4 . Toilet paper holder at water closet.
5. Mirror and medicine cabinet or equivalent
enclosed storage.
6. Two towel bars.
Each half bath shall be provided with Items 3 , 4 , 5 , and 6,
as stated above.
Stall showers should have a minimum area of 1024 sq. in.
and a least dimension of 30 in.
Water impervious wainscot shall be provided at walls around
showers or tub-showers to a height of six feet from the
finished floor.
The floor surface of every water closet compartment, bath-
room and shower room shall be installed so as to be reason-
ably impervious to water and so as to permit such floor to
be easily kept in a clean and sanitary condition.
409 KITCHEN FACILITIES
Each living unit shall have a specific kitchen space, which
contains a sink with counter work space and has hot and
cold running water, adequate space for installing cooking
and refrigeration equipment, and for storing cooking utensils .
A stove or oven or similar device for cooking food and a
refrigerator or similar device capable of the safe storage
of food at temperatures less than 50°F. but more than 32°F.
under ordinary maximum summer conditions, shall be properly
installed with all necessary connections for safe, sanitary,
and efficient operations .
The use of gasoline stoves or other similar fuel burning
appliances using highly flammable liquids and the use of
-14-
•
•
portable kerosene, butane, or propane stoves or other
similar portable appliances for cooking is prohibited.
Electrical hot plates shall not be permitted.
410 KITCHEN STORAGE OR OTHER MINIMUM REQUIREMENTS
Minimum areas of kitchen storage space should be as follows:
1. Total shelving in wall and base cabinets -
30 sq. ft.
2 . Drawer area - 5 sq. ft.
3 . Usable storage shelving in cooking range or
under sink may be counted in the total shelving
needed.
4. All kitchen cabinets shall have doors and the
appropriate hardware in proper working condition.
5. Minimum countertop excluding range and sink -
6 sq. ft.
6 . Minimum shelf width - 10 inches.
Kitchen storage space of living units having two or more
bedrooms should be appropriately increased in total area
to accommodate the needs of more occupants.
411 GENERAL STORAGE AND CLOSETS
Each living unit shall have a suitable space within the
unit or a locked space elsewhere within the building for
general storage.
The minimum volume of general storage space for each living
unit should be 100 cu. ft. and should be increased for three
or four bedroom living units accordingly to a ratio of 50
cubic feet for each additional bedroom for units containing
more than two bedrooms.
Clothes closet space shall be provided within bedrooms or
conveniently located nearby, and should provide a minimum
of 6 sq. ft. per sleeping area. For hanging clothes effi-
ciently a shelf and hanging rod should be provided, pref-
erably in closets of not less than 2 ft. deep.
It is recommended that closet space not be located within
a kitchen. Closets should be permanently installed with
doors and appropriate hardward in good working condition.
412 PRIVACY AND ARRANGEMENT
A degree of privacy shall be provided commensurate with
suitable living conditions by means of the proper location
of exterior openings to the outside of the building, and
by the interior arrangement of rooms .
-15-
Access to all parts of a living unit shall be possible
within the unit itself without passing outside the unit.
Every water closet, bathtub or shower of a living unit
shall be installed in a bathroom or toilet compartment
which will afford privacy to the occupant.
A bathroom should not be used as a passageway to a habit-
able room, hall, basement or to the exterior.
Where the access to an existing bathroom is through a bed-
room in living units having more than one bedroom, this
planning arrangement may be acceptable if there is no
feasible alternative.
A bathroom should not be separated from all bedrooms of
a living unit by locating it a full story above or below
the bedrooms.
A bedroom should not be used as the only means of access
to another bedroom or habitable room.
413 CEILING HEIGHTS
Ceiling heights shall permit the average person to move
about comfortably, and create no unpleasant sensation
because of the ceiling being of insufficient height.
The ceiling heights for habitable rooms, bathrooms and
public and private halls shall be at least the following:
1. Habitable rooms - 7 ft. 6 in.
2 . Bathrooms, toilet compartment, utility rooms -
7 ft.
3 . Public corridors - 7 ft.
4 . Halls within living units - 7 ft. clear
5. Suspended ceilings or panels - 7 ft.
6. Sloping ceiling - no portion less than 5 ft. 0 in.
414 SPACE AND LAUNDRY FACILITIES
Adequate space shall be provided for laundry equipment off
a public corridor, or in a basement or other suitable public
space for the use of all occupants of a building. Where
nearby public commercial laundries are available, consider-
ation may be given as to the extent residents of the project
can be expected to use them in determining laundry space
needs . Laundry facilities may be located in an attached
accessory building on the same lot as the main structure.
415 DOORS AND ACCESS OPENINGS
Provide openings adequate in size to admit furniture and
equipment to all spaces and to permit inspection for repair
and maintenance. Exterior doors to corridors shall be self-
closing with rising butt hinges or closers .
-16-
•
415-1 EXTERIOR DOORS
Exterior doors shall have safe locks and be at least the
following sizes :
WIDTH HEIGHT
1. Main entrance door 3 ' 0" (a) 6 ' 8"
2 . Service doors 2 ' 8" 6 ' 8"
(a) (1) Where serving 12 or more living units - 3 ' 4"
415-2 INTERIOR DOORS
Provide a door for each opening to a bathroom, bedroom
or toilet compartment, with a locking device on bath
and toilet compartment doors . Doors should be at least
the following sizes :
1. Habitable rooms, 2 ft. 6 in. wide.
2 . Bathroom, toilet compartments and closets other
than linen and broom, 2 ft. 6 in. wide.
3 . Service stair doors, 2 ft. 6 in. wide.
4 . Cased openings , 2 ft. 6 in. wide.
5. To public stairway enclosures, single door -
3 ft. 0 in. wide; double - 2 ft. 4 in. wide.
6. Height of all interior doors , 6 ft. 8 in.
415-3 ATTIC AND BASEMENTLESS SPACES
Access to attics should be provided by means of conven-
iently located scuttles or a disappearing or permanently
installed stairway. For attic and basementless spaces,
the minimum access opening should be 14 x 22 inches.
However, if either are to contain mechanical equipment,
the access opening shall be of sufficient size to permit
the removal and replacement of the equipment.
416 STAIRWAYS
All stairways shall provide safety of ascent and descent,
and landings shall be arranged to permit adequate headroom
and space for the passage of furniture and equipment. All
exterior and interior stairways shall be provided with arti-
ficial lighting , manually or time controlled in the same
manner as the lighting of public spaces . If manually con-
trolled, a light switch should be provided at the top and
bottom of each stairway.
416-1 EXISTING STAIRWAYS
Existing stairways in sound condition to remain or to be
repaired should not be to any serious extent below minimum
standards of good practice as to rise and run of steps ,
headroom, obstruction, stair width, landings, or railing
protection.
-17-
•
416-2 NEW STAIRWAYS
New stairways to be constructed shall comply with standards
of good practice and be appropriate to the building and
occupant load.
417 GUARD RAILS
Guard rails shall be provided as a vertical barrier at
abrupt differences in floor level such as, but not limited
to, floor openings , wall openings, platforms, runways,
mezzanines, roofs, ramps and bridges to prevent falls of
persons where such differences in floor levels exceed 24
inches.
418 HANDRAILS AND RAILINGS
Handrails and railings shall be provided where needed to
protect occupants from falls.
Exterior platforms, porches and stairs extending 2 ft. or
more above grade, balconies and roof decks accessible to
occupants and unprotected by walls shall have railings or
enclosures.
Railings or enclosures at exterior corridors and balconies
and roof decks accessible to occupants shall be continuous
and at least 42 in. in height and the balustrade shall be
designed to prevent the passage of a spherical object hav-
ing a diameter greater than 5 in.
419 RAILINGS AT STAIRS
a. Stairs shall have a continuous handrail on at
least one side and railings at open portions
of sides where there are four or more risers.
b. Interior public stairs 44 in. or more in width
shall have handrails on both sides.
c. All interior and exterior stairwells including
those in attics shall have railings around open
sides.
420 LIGHT AND VENTILATION
420-1 GENERAL
Provide a healthful environment and an acceptable degree
of comfort within all rooms and hallways of the dwelling
by having sufficient light and ventilation, and to provide
natural ventilation for structural spaces to minimize con-
ditions conducive to decay and deterioration.
-18-
420-2 HABITABLE ROOMS
Where an interior room without its own source of natural
light and ventilation is adjacent to an outside room having
both, consideration should be given to its acceptance as a
habitable room, calculated on the basis of the combined
floor area of the two rooms, where the separating wall
between them has an opening either 6 ft. wide or is 70 per-
cent as wide as the inside room.
420-3 BATHROOM AND TOILET COMPARTMENTS
Artificial lights shall be provided. Provide ventilation
by mechanical means or by natural means - 5 percent of floor
. area but not less than 1 1/2 sq. ft. open window area.
NOTE: Ventilation of bathrooms in small buildings
is sometimes accomplished by a gravity-type
vent equipped with a winddriven roof ventilator
above the roof level.
420-4 PUBLIC SPACES
Artificial light shall be provided in all public spaces
and should be time controlled to come on at sunset and off
at sunrise.
420-5 PUBLIC ENTRANCE SPACES
Provide either natural ventilation of at least five percent
of floor area or mechanical ventilation.
Public hallways and unenclosed stairways should be provided
with either natural ventilation (at least five percent of
floor area) or mechanical ventilation. Enclosed public
corridors should be ventilated mechanically.
420-6 VENTILATION OF UTILITY SPACES
Utility spaces which contain heat producing, air condition-
ing and other equipment shall be ventilated to the outer
air, and air from such spaces shall not be recirculated to
other parts of the building.
420-7 VENTILATION OF STRUCTURAL SPACES
Natural ventilation of spaces such as attics and enclosed ' '
basementless spaces shall be provided by openings of suffi-
cient sizes to overcome dampness and minimize the effect of
conditions conducive to decay and deterioration of the
structure, and to prevent excessive heat in attics. Exterior
ventilation openings shall be effectively screened.
-19-
421 ELEVATORS
Where provided, an elevator shall furnish convenient and
safe ascent and descent to all living units and service
areas. The character and type of elevator service and
equipment should be appropriate to the building being reha-
bilitated and to its occupants.
Four story buildings should have one or more elevators where
there are six or more living units per floor and where the
desireability of the property would be doubtful if there
were no elevator service. Buildings of more than four stories
having six or more living units per floor should have
appropriate elevator service provided.
422 TRASH AND GARBAGE DISPOSAL
Every dwelling and multi-family building shall be supplied
with a means of disposal or removal of trash and garbage.
Where disposal will not take place promptly there shall be
convenient and appropriate temporary sanitary storage for
trash and garbage provided, which is inaccessible to rodents.
423 NOISE CONTROL
Where there is revised planning and new construction con-
templated of floors and partitions between living units and
between living units and public and service spaces, consid-
eration should be given to using noise reduction and noise
isolation techniques in order to provide acoustic separa-
tion and auditory privacy.
Design and Construction Suggestions
(1) Where practical, functional areas of high noise
should be separated from areas of quiet. Clothes
or storage closets are useful separators.
(2) Partitions should extend to solid floor-ceiling
construction and should not terminate at hung
ceilings.
(3) Pipes should be caulked and wrapped and ductwork
should be sealed where they penetrate sound-
impeding partitions and floors. Ducts should be
lined near registers or grilles, and at fan dis-
charge.
(4) Motors, fans and other mechanical equipment should
be balanced and mounted.
-20-
•
(5) Where kitchens or bathrooms are located back-to-
back, special attention should be given to the
construction to reduce noise from plumbing fix-
tures and noise through medicine cabinets.
(6) Where living units are adjacent to high noise
areas such as boiler rooms or other mechanical
equipment, the construction separating the spaces
should provide a greater noise reduction than
normal room separation.
-21-
CHAPTER V
FIRE PROTECTION
501 OBJECTIVE
To assure a high degree of safety to life and property
preservation, by the separation of living units and the
use of materials which will retard the spread of fire and
prevent the passage of flame, smoke and hot gases through
open or concealed spaces within the building, and to pro-
vide means of egress which will permit persons to leave
the building with safety in an emergency, and permit access
for fire control personnel.
502 GENERAL
These provisions apply to rehabilitation construction of
existing buildings . However, where the construction, plan
arrangement and approximate number of occupants of a property
are to remain unchanged and the fire protection provisions
of the local code are complied with, noncompliance with the
provisions of this chapter may be acceptable , but should in
no case be less restrictive than the provisions of NFPA 101
unless it is determined by the appropriate authority that
noncompliance with the provisions will not substantially
affect the safety of the occupants in the event of a fire
or other emergency.
503 REQUIRED MEANS OF EGRESS
Apartments shall have a minimum of two means of egress re-
quired where the number of occupants is over 10 and the
square foot per occupant exceeds 200 gross or exceeds 2, 000
sq. ft. in total floor area of the structure.
Every story or portion thereof , having an occupant load of
500 to 1000 shall have not less than three means of egress,
as remote from each other as practicable.
Every story or portion thereof , having an occupant load of
more than 1000 shall have not less than four means of egress,
as remote from each other as practicable.
Elevators shall not be considered a required means of egress.
An exterior stairway conforming to the design requirements
of interior stairs as to width, handrails, tread and riser
dimension, etc. may be acceptable as a required exit.
504 TRAVEL DISTANCE
Exits and means of access to apartments thereto shall be so
located that it will not be necessary to travel more than
50 feet nor to traverse more than one flight of stairs,
-22-
within any individual living unit to reach the nearest
exit, or to reach an entrance door of the apartment
which provides access through a public corridor to an
exit on the same floor level within 100 feet of the door,
or within 150 feet in a building protected by automatic
sprinklers.
505 ARRANGEMENT OF EXITS
Where two means of egress are required, such means of
egress shall be located a distance apart equal to not
less than one-fifth of the perimeter of the area served
or as remote from each other as practicable and so arranged
as to minimize the possibility that both may be blocked by
any one fire or other emergency condition.
Where three or more means of egress are required, they
shall be arranged a reasonable distance apart so that if
one becomes blocked others will be available.
Where the secondary exit is by means of an openable window,
the opening should be at least five sq. ft. in area with a
minimum dimension of 22 in. The bottom of the opening or
sill height should be not more than 32 in. above the floor.
Where storm windows, screens or burglar guards are used,
these should be readily openable from the inside.
Every below grade living unit shall have not less than two
means of egress to the outside of the building at grade
level .
506 STAIRWAYS
All interior stairways required to be enclosed shall lead
directly or through an enclosed passageway to a street, or
to open air outside at ground level that is accessible to
a street. Such a passageway shall conform to the require-
ments applying to the stair enclosure.
In every building more than three stories in height, one
stairway shall extend to the roof surface unless (1) the
roof has a slope greater than three in 12; or (2) access
to the roof is for no purpose other than maintenance to
the roof and equipment thereon.
The underside of all existing flights of wood stairs to
remain, if exposed, shall be covered with a noncombustible
material.
507 GUARDS AND RAILS
All exit stairways shall be protected at the sides by
acceptable guards wherever needed for the safety of users
and should have a handrail on at least one side.
-23-
•
508 WALLS , FLOOR AND CEILING CONSTRUCTION
Walls and ceilings of corridors used as required exits
shall be not less than one hour fire-resistive construction
except where required to be two hour fire-resistive. In-
terior bearing walls shall be three hour fire-resistive
construction.
Existing walls, floors and ceiling construction separating
living units or separating a living unit from a public
corridor where stripped down for a new finish material or
where it is new construction shall have a fire resistance
rating of at least one hour.
509 ENCLOSURE OF VERTICAL OPENINGS
Where there is new construction of elevator shafts, vent
shafts and other vertical openings the enclosure shall be
of materials and fire resistance rating appropriate to the
type of construction of the building and shall provide fire
safety. (See Section 1807 Vertical Openings of the South
Florida Building Code) .
510 TRANSOMS
Apartment buildings shall have no transoms or ventilating
openings from guest rooms to enclosed public corridors.
511 FIREWALL, PARTY OR LOT LINE WALL
Firewall, party or lot line walls shall be continuous from
foundation to the underside of or through, the roof, with
openings in firewalls only in corridors and where properly
protected with appropriate automatic fire doors. There
shall be no openings in party or lot line walls . All such
walls shall effectively prevent the passage of fire at every
floor-ceiling intersection with the wall.
512 ROOF COVERINGS
Roof coverings shall be capable of resisting fire appropri-
ate to the type of construction and location, and new
installations shall be in accordance with nationally recog-
nized standards. Fire retardant qualities of roof coverings
shall conform to the classification established by the
Underwriters Laboratories , Inc . , referred to as "U.L. " .
No roof coverings of multi-family buildings shall provide
a fire-resistance equivalent to a Class A or B rating
according to U.L. classification.
-24-
513 FIRE ALARM SYSTEMS
Every apartment building, unless provided with an auto-
matic sprinkler system or automatic fire alarm system
shall have a manual fire alarm system if such building
is of more than three stories in height or more than
twelve apartment units.
Fire alarm system, where required, shall be installed in
accordance with the appropriate National Fire Protection
Association Standard - Nos. 71, 72a, b or c.
514 SPRINKLER SYSTEM
An automatic sprinkler system where used shall be of
a standard approved type, and installed to provide cover-
age of all portions of the building designated for protec-
tion. The installation shall conform to NFPA No. 13
"Standards for the Installation of Sprinkler Systems" .
515 INTERIOR FINISH
Interior finish materials of walls, partitions (fixed or
movable) , ceilings and interior trim shall not be subject
to excessive surface flame spread, or in burning shall not
give off excessive amounts of smoke or toxic gases.
Where no interior wall and ceiling finish materials are
used, the surface flame spread shall not exceed the class
or range of rating shown in table below. Existing, undis-
turbed finish materials where considered to have a rating
above 200 should be covered with a flame retardant paint.
FLAME SPREAD CLASSIFICATION OF INTERIOR FINISH
Flame Spread Rating
Location (1) (2) Class (5) Maximum Range
Exits and Exit Access (halls,
corridors, entrys) (4) A or B 0-75
Within Living Unit (3) (4) A, B or C 0-200
Public Roars (4) A, B or C 0-200
Service Roams, enclosing
fire hazardous equipment A 0-25
NOTES:
(1) Exclude windows, trim and doors not more than 25 sq. ft. area
frau flame spread calculations.
(2) Finish floors and floor coverings are not included in flame
spread requirements but shall not be a fire hazard.
-25-
(3) Kitchen cabinets and counter tops should not exceed a
200 flame spread rating.
(4) Draperies when provided shall be flameproof in accordance
with NFPA Standard No. 701 "Flameproof Textiles".
(5) Classification in accordance with NFPA No. 101, "Life
Safety Code", as follows:
Class A = 100 - 25 Flame Spread
Class B = 25 - 75 Flame Spread
Class C = 75 - 200 Flame Spread
Class D = 200 - 500 Flame Spread
-26-
CHAPTER VI
MATERIALS AND PRODUCTS
601 OBJECTIVE
To provide materials of such kind and quality as to assure
that the dwelling will provide : (a) appropriate structural
strength, (b) adequate resistance to weather and moisture,
and (c) reasonable durability and economy of maintenance.
602 GENERAL
All materials, assemblies and components shall be in accord-
ance with the provisions of this Standard and shall be of
such kind and quality to assure adequate strength, durability,
corrosion resistance, fire resistance, economy of maintenance,
safety of operation, and other required qualities suitable
for the intended use.
603 QUALITY OF MATERIALS AND PRODUCTS
All materials and products used as replacements or additions
in rehabilitation construction shall be of good quality con-
forming to generally accepted good practice. Second-hand
materials which meet the standards for new materials may be
used when approved by the proper local authority. The suita-
bility of special materials and products not conforming to
a national standard shall be determined by proper authority,
after an evaluation of its properties and performance char-
acteristics.
604 STANDARDS FOR MATERIALS AND PRODUCTS
For specific requirements of new materials and products used
as replacements or additions to dwellings being rehabilitated,
reference shall be made to the South Florida Building Code
and the standards of the American Society for Testing Mater-
ials.
605 REFERENCED STANDARDS
Except as modified herein, material shall comply with the
applicable standards listed in the South Florida Building
Code. The current edition of the nationally recognized
standards referenced herein shall govern except where the
reference is to a specified date standard.
606 LABELING
Materials and products shall be labeled or otherwise identi-
fied as conforming with the applicable standards .
-27-
•
•
CHAPTER VII
CONSTRUCTION
701 OBJECTIVE
Construction shall assure that the building will provide:
1. Adequate strength and rigidity.
2. Equipment that is safe and of reasonable economy
of operation.
3 . Adequate protection from corrosion, decay, insects
and other destructive forces.
4 . Necessary resistance to the elements including
prevention for penetration of excessive noise
and moisture and limitation on the infiltration of
unwanted air and dust.
5. Necessary durability for the intended life span
of the unit assuming reasonable maintenance.
6 . Acceptable workmanship reflecting journeyman
quality work of the various trades .
702 STRUCTURAL SOUNDNESS
All structural components of the building shall be in sound
condition and considered serviceable for the expected use-
ful life of the rehabilitated building. Sagging or out of
plumb floors, chimneys, fireplaces, partitions or stairs,
and bulging of exterior walls shall be restored as near as
practical to an acceptable level of plumb position; and
supported or braced so as to prevent a reoccurrence of these
conditions. Stair railings shall be rigid. Individual
structural members in a seriously deteriorated condition
shall be replaced. Loosely jointed structural members shall
be restored to original rigidity. An inspection shall be
made of both interior and exterior construction for evidence
of rot, rust or decay damage and other deteriorating con-
ditions. Where structural damage to such materials is found
to exist, correction shall be provided. The City may require
that such correction be under the supervision and seal of a
qualified engineer or architect.
703 CONSTRUCTION PERFORMANCE
Construction shall be performed in such manner that the
workmen and public are protected from injury, and adjoin-
ing property is protected from damage.
704 SAFETY AND HEALTH REGULATIONS
Compliance with the provisions of the safety standards of
the Occupational Safety and Health Administration, as they
apply to residential construction is mandatory and shall be
the responsibility of the contractor.
-28-
► • .
•
.
705 FOUNDATIONS AND EXTERIOR WALLS
705-1 GENERAL
Foundations and exterior walls shall provide safe and
adequate support for all loads upon them, and prevent
the entrance of water or excessive moisture. Serious
defects shall be repaired and cracks effectively sealed,
or replace the affected area.
Basement and foundation walls shall prevent the entrance
of water or moisture into a basement or crawl space area.
Cracks in the walls shall be effectively sealed, and loose
or defective mortar joints shall be replaced. Where neces-
sary, the interior or exterior face of the walls shall be
dampproofed by bituminous coating and cement parging.
Any deficiencies in proper grading or paving adjacent to
the building shall be corrected to assure surface drainage
away from basement walls.
706 PARTITIONS, COLUMNS AND POSTS
Partitions and other vertical supports which are to be con-
tinued in use shall be free of splits, excessive lean,
buckling or other defects.
707 FLOOR CONSTRUCTION
707-1 GENERAL
All floor construction shall provide safe and adequate
support for all existing or probable loads and shall be
reasonably free of objectionable vibration and be level.
A suitable surface for finish flooring shall exist or be
provided.
707-2 BASEMENT AND CELLAR FLOORS
The floors at all basement or cellar furnace rooms, or base-
ments containing habitable space, shall be paved in an
acceptable manner, except under the following condition:
Where the basement or cellar has existing
wood floor construction over a crawl space
which is in a sound, undamaged condition,
it may remain provided the crawl space is
adequately vented.
708 CHIMNEYS, AND VENTS
Chimneys and vents shall be structurally safe, durable,
smoketight and capable of withstanding the action of flue
gases . Factory-built chimneys shall be labled by Under-
writer' s Laboratories , Inc. and installed in accordance
with the listing.
-29-
709 PROTECTION FROM RODENTS , TERMITES OR OTHER INFESTATION
Each building and all exterior appurtenances on the site
shall be effectively protected against rodents , termites
or other vermin infestation.
710 INSPECTION AND CORRECTION
A careful inspection by qualified licensed persons shall
be made of each building and accessory structure on each
property for evidence of actual or potential infestation
or access channels . Existing buildings where found to
have defects that will permit the entrance of rodents, ter-
mites or other vermin shall be corrected by appropriate
preventive measures. Damaged or deteriorated structural
members shall be replaced.
711 TERMITE AND DECAY DAMAGE
Following are a number of corrective and preventive measures
against infestation and decay:
1. Precautions or corrective actions recommended
by bonded exterminators to be applied;
2. Windows or other openings near grade to have
• snug-fitting screens;
3 . Exterior doors to fit tightly and be flashed at
sill; kick plates to be installed near the bottom
of exterior doors;
4 . Openings for pipes or ducts through floors or
walls to have tight fitting collars;
5 . Cracks and crevices in foundations and above
ground walls to be effectively sealed by point-
ing with mortar, and holes filled with materials
appropriate to adjacent work;
6. Provision of curtain wall below grade and supple-
mentary to the foundation;
7 . Locating sidewalks , driveways or other impervious
horizontal surfaces flush against the foundation;
8 . Cracked or broken shingles or decayed wood sur-
faces to be replaced and joints caulked;
9 . Appropriate soil poisoning treatment used adjacent
to foundations and within hollow masonry founda-
tions; and soil to be treated in enclosed spaces.
10 . All attic ventilation openings and crawl spaces
shall be adequately screened.
-30-
•
712 DECAY
For construction near the soil or otherwise subject to
moisture, the replacement of decay damaged lumber or
finish materials , if of wood, shall be preservately
treated or be of a naturally resistant species.
713 INSULATION
Where existing exterior walls and top floors do not have
insulation, consideration should be given to installing
the proper amount of insulation to prevent excessive heat
loss and to provide comfort for residents .
-31-
CHAPTER VIII
EXTERIOR AND INTERIOR FINISHES
801 OBJECTIVE
To assure that the building will acceptably: a) prevent
the entrance or penetration of moisture and weather, b)
protect from damage by decay, corrosion, insects and other
destructive elements and c) provide reasonable durability
and economy of maintenance.
802 EXTERIOR
1. Exterior wall finishes shall be installed in
a manner to restrict the entrance of moisture
and weather. Attachment and/or anchorage of
finish or backing to the structure shall be
adequate to resist design wind forces.
2 . Use of a brittle or otherwise easily injured
exterior finish materials shall be restricted
to 7 ft. 0 in. or more above grade where
large numbers of children are anticipated or
where the probability of damage to the exterior
finish is considerable.
3. Repairs or replacement shall be made to defective
exterior wall finish materials. Exterior walls
shall be free of holes, cracks and broken or
rotted finish materials.
803 ROOF COVERINGS
803-1 GENERAL
1. Roof coverings shall restrict the entrance of
moisture and weather, be resistant to the causes
of deterioration, and provide an attractive appear-
ance. Attachments and/or anchorage of covering
to roof sheathing shall be adequate to resist
design wind forces .
2 . All roofing materials shall be installed in accord-
ance with the recommendations of the manufacturer
unless otherwise indicated in the standards.
3 . All roofs shall have a suitable, watertight and
reasonably durable covering free of holes, cracks,
excessively worn surfaces or other defects .
4 . Repairs to existing roofs shall be complete and
done in accordance with new construction standards
unless the area to be repaired is less than 1/4 of
the roof surface.
-32-
5. The placing of a new roof covering over an
existing roof covering is not prohibited but
shall be governed by the material manufacturer' s
recommendations.
803-2 GUTTERS AND DOWNSPOUTS
Each building shall have a controlled method of disposal
of water from roofs where necessary to prevent damage to
the property, and to avoid causing unsightly staining of
walls and windows where adequate roof overhangs are not
provided.
803-3 FLASHING
To prevent the entrance of water, all critical joints in
exterior roof and wall construction which are exposed or
partly exposed shall be protected by sheet metal or other
suitable flashing material.
804 DOORS, WINDOWS AND OTHER OPENINGS
804-1 DOOR PERFORMANCE - GENERAL
Doors and door hardware shall be durable and installed in
good operating condition, free of defects , latching readily
and locking securely.
Existing windows and doors, including their hardware shall
operate satisfactorily and give evidence of continuing
acceptable service. Defective glass or locking mechanisms
shall be replaced or repaired.
The following guides should be used to determine the need
for repair or replacing trim, window sash, doors and frames:
1. Repair, if work can be done in place,
2. Replace, if the entire component needs to
be removed in order to restore.
3 . Refinish, if only the surface needs work
in order to restore to new condition.
804-2 EXTERIOR DOORS (INSTALLATION)
Exterior doors used as a fire exit discharge should be
equipped with panic hardware.
Doors shall be installed to assure adequate structural
strength, weathertightness and shall be capable of resist-
ing extremes of moisture, wind and temperature. Doors shall
be safe and assure reasonable economy with ease of mainten-
ance. No hollow core doors shall be permitted on exterior
openings.
-33-
804-3 WEATHERSTRIPPING
All exterior doors shall be provided with a tight threshold
and weatherstripping to prevent infiltration of dust, heat
or rain.
804-4 MISCELLANEOUS
All doors, including storm and screen doors opening outward
should be provided with a safety door check.
805 WINDOWS
805-1 INSTALLATION
Windows shall be installed in accordance with the recommen-
dations of the manufacturer. Operating hardware shall be
installed and shall operate freely without excessive effort.
Windows in buildings four or more stories in height should
be inside glazed or have sash or ventilators that can be
glazed from inside of the building. All glass and glazing
beads shall be replaceable. All windows shall be effectively
caulked to prevent the entrance of water and wind between
the window unit and the wall opening.
805-2 WEATHERSTRIPPING
All windows shall be weatherstripped to prevent the infil-
tration of dust, wind or rain.
805-3 WINDOW FRAME ANCHORAGE
All windows shall be anchored at heads, sills, mullions
and jambs with standard or special anchors as required.
806 SCREENS
Screens shall be provided for all windows, doors and other
openings. Existing screens , and storm sashes which are to
be continued in use shall be in suitable condition to serve
their intended purposes . The patching of window screens is
not permitted.
807 HARDWARE AND SECURITY
Locking devices at doors and windows shall be as follows :
1 . All sliding doors , first floor and basement
windows, and windows opening onto stairways,
fire escapes, porches, terraces, balconies, or
other areas affording easy access to the premises,
shall be equipped with a locking device which can
be easily unlocked from inside the building.
-34-
2 . Swinging entrance doors to individual units
shall be secured by combination dead latch
and dead bolt sets with latch throw a minimum
of 1/2 inch and bolts having a one inch mini-
mum throw. Entrance doors to a single living
unit shall be keyed alike. At least one such
entrance door shall be provided with a door
scope or vision panels located no higher than
five feet from the bottom of the door. Glass
jalousie doors should be equipped with an
approved burgler screen.
3 . Bathroom, toilet room, and primary bedroom doors
shall be equipped with a privacy lock which can
be opened from the outside in an emergency.
808 INTERIOR WALL AND CEILING FINISHES
808-1 GENERAL
Wall and ceiling finishes shall be suitably secured to a
subbase or framing members . All accessories , trim and
fittings and moldings shall be installed in accordance
with manufacturer' s directions.
All interior walls and ceilings shall provide (a) a finished
level and even surface without noticeable irregularities or
cracking, (b) a waterproof and hard surface in spaces sub-
ject to moisture, (c) a suitable base for painting or other
decoration and (d) reasonable durability and economy of
maintenance.
808-2 CONDITIONS OF USE
1. Wall finishing materials shall provide a wash-
able finish to the extent of removing ordinary
household stains. The finish of walls in kitchens,
bathrooms and laundries shall be smooth and be
resistant to being stained or damaged by grease,
water , detergents and normal household chemicals.
2 . Gypsum wallboard used as backing for wainscot in
showers or tub enclosures shall be water resistant.
Insulating (foil-backed) wall board shall not be
used in this area.
3 . When used, hardboard shall be Class I-Decorative
grade hardboard for interior wall finish or baths,
kitchens and laundries and Class I or II-Decora-
tive grades hardboard for other interior wall
finishes.
-35-
•
p
809 FINISH MATERIALS
809-1 GENERAL
The installation method and workmanship of applying
finishing materials shall be in accordance with the
manufacturer' s directions unless modified herein.
Application of a given material shall at least comply
with the stated installation method set forth herein.
810 FINISH FLOORS
Finish floors shall be appropriate to the use of the
space; be in good condition, provide reasonable ease
of maintenance , and an extended service life.
Habitable Rooms (other than kitchen) . Finish floors in
habitable rooms should be wood flooring, a resilient
tile, sheet material, finished concrete or terrazzo,
or carpeting over a suitable underlayment.
Kitchen and Bathroom Floors. Floors in kitchens and
bathrooms shall be of a durable, waterproof, non-
absorptive material, such as asphalt, vinyl-asbestos,
vinyl-plastic, rubber or ceramic tile, finished con-
crete, or carpeting over an underlayment. In public
entrance spaces or lobbies special consideration
should be given to the selection of a finish flooring
that is resistant to water and dirt.
The carpeting of stairways in multi-family buildings
is not recommended.
811 PAINTING AND DECORATION
Protective and decorative finish coating or surfacing
shall provide (a) adequate resistance to weathering,
(b) protection of finish surfaces from moisture or
corrosion, (c) an attractive appearance, (d) reasonable
durability.
Appropriate cleaning of existing interior and exterior
finish surfaces should be done regardless of whether or
not painting or other decoration work is provided.
The use of lead base paint is not permitted.
-36-
CHAPTER IX
MECHANICAL EQUIPMENT
901 OBJECTIVE
To provide mechanical equipment for the building and its living
units that will meet the needs of the intended occupants and be of
a quality and condition which will assure: (a) Safety of operation,
(b) adequate capacity for its intended use, (c) protection from
moisture, corrosion or other destructive elements, (d) reasonable
quietness of operation, and (e) reasonable durability and economy
of maintenance.
902 GENERAL
All mechanical equipment shall be installed so that maintenance and
replacement can be performed without the removal of other equipment.
Existing mechanical equipment and systems shall be inspected for
faulty operation, fire or other hazards. Needed replacement, or
repair shall conform to code requirements .
Provisions relating to mechanical equipment and wiring given to
Chapter 45 of the South Florida Building Code shall be used as a
guide in making determinations as to the suitability of existing
equipment for continued use in the rehabilitated structure.
903 MECHANICAL VENTILATION AND AIR CONDITIONING
Where mechanical ventilation is required in rooms or other spaces,
the equipment or system shall operate satisfactorily if presently
in place, or if new, shall be designed and installed according to
good engineering practice.
Where air conditioning is to be included, whether a central system
or packaged room or zonal air conditioners, the provisions of
Chapter 49 of the South Florida Building Code shall be followed.
904 HEATING, AIR
Heating Facilities. Heating facilities shall be provided for each
living unit and other spaces that will (a) assure interior comfort,
(b) be safe and convenient to operate, (c) be economical in perfor-
mance, and (d) be quiet in operation and free from objectionable
drafts .
Each heating system or device shall have a recognized approval for
safety and shall be capable of maintaining a temperature of at least
70 degrees F. within the living units, corridors, public spaces and
utility spaces when the outside temperature is at the design temper-
ature.
Venting. All fuel burning air heaters (including individual space
heaters) shall be connected to a vent leading to the exterior of the
structure.
-37-
S
905 HEATING, WATER
Existing equipment. Existing water heating and storage equipment
shall be in good serviceable condition, or otherwise replacement
of the equipment shall be considered by the proper authority.
Prohibited locations . No water heater shall be installed in any
room used or designed to be used for sleeping purposes . No gas
or oil fired water heater shall be located in a bathroom, clothes
closet, under any stairway, or in a confined space with access
only to the above locations.
Venting. All fuel burning water heaters shall be connected to a
vent leading to the exterior.
Solar water heating systems . Solar water heaters shall be in
serviceable condition and conform with the South Florida Building
Code, Section 4008, with tank enclosures covered with corrosion-
resistant sheet metal. Solar water heating systems shall be of
adequate capacity for the number of living units served by the
system.
Solar water heating systems shall include automatic electric
booster heaters to assure an adequate supply of hot water to each
living unit during prolonged periods deficient of sunshine.
Where replacement of a solar water heater is required it shall be
replaced with a gas, oil or electric heater or an approved solar
water heating system.
906 CAPACITIES
One bedroom to two bedroom living units (individual water heaters) .
Capacity shall be not less than 20 gallons for gas or oil-fired
water heaters and 30 gallons for electric heaters, except that
electric water heaters restricted by "off-peak" control limitations
should have a minimum capacity of 52 gallons.
Three or more bedroom living units (individual water heaters) .
Capacity shall not be less than 30 gallons for gas or oil-fired
water heaters and 40 gallons for electric water heaters , except
that electric water heaters restricted by "off-peak" control
limitations should have a minimxm capacity of 56 gallons.
-38-
• .
Capacities given on heating capacity chart should be used
as a guide for determining the adequacy of existing equip-
ment, and should be followed in the design of new equipment.
907 HEATING CAPACITY - GPH 100° F. RISE
NUMBER OF STORAGE CAPACITY PER LIVING UNIT
LIVING
UNITS 0 Gal. 5 Gal. 10 Gal. 15 Gal. 20 Gal. 25 Gal.
3 85 79 74
4 89 82 75
5 94 85 77
6 109 98 88
7 124 111 99
8 152 138 124 110
9 159 143 127 112
10 165 143 130 113
15 248 222 195 169
20 365 330 295 260
25 457 413 369
30 600 548 495 443
35 660 599 538 475
40 720 650 580 510
50 810 723 635 548
60 900 795 690 585
80 1050 910 770 630
100 1150 975 800 625
120 1250 1040 830
140 1350 1105 860
160 1440 1160 880
180 1525 1210 895
200 1600 1250 905
225 1700 1308 915
250 1800 1363
275 1900 1420
300 2000 1475
NOTE: Table above gives the recommended minimum recovery
rate in gallons per hour at 100°F. rise according
to the storage capacity, (or size) , of the tank and
for a designated number of living units . The blank
spaces in the table mean the tank size would be
either too small to provide sufficient hot water,
or too large a tank to be practical.
-39-
CHAPTER X
PLUMBING
1001 GENERAL
The plumbing system and its appurtenances for each
building shall provide satisfactory water supply,
drainage, venting and operation of fixtures .
1002 CONDITION OF EXISTING PLUMBING
Plumbing systems including building sewers shall operate
free of fouling and clogging, and not have cross connec-
tions which permit contamination of water supply or back-
siphonage between fixtures. Sinks, lavatories, bathtubs,
and toilets which are chipped, rusted, permanently stained
or otherwise damaged or deteriorated should be replaced
or refinished by an approved refinishing process. All
water or waste lines which do not show evidence or con-
tinual durability shall be replaced. Plumbing fixtures
including connections shall be properly installed, operate
properly, be free from leaks, excessive rust and deterio-
ration, and give evidence of necessary durability assuming
reasonable maintenance.
1003 NEW PLUMBING WORK
For additions or changes made to present plumbing. The
plumbing equipment and materials shall comply with and
be installed in accordance with Chapter 46 of the South
Florida Building Code.
-40-
• •
CHAPTER XI
ELECTRICAL
1101 GENERAL
All habitable rooms and other appropriate spaces requiring
electrical service shall be provided with a system of wiring,
wiring devices and equipment to safely supply electrical
energy for proper illumination, appliances, resident
security, and other electrical equipment.
1102 EXISTING WIRING AND EQUIPMENT
Existing wiring and electrical equipment where its con-
tinued service is contemplated shall not be a potential
source of electrical hazard or ignition of combustible
materials, and shall be so determined by the proper author-
ity. Wherever these potential hazards are determined to
be present, replacement of existing wiring and equipment
shall be made. Existing facilities that are inadequate to
meet anticipated demands shall be appropriately increased
as determined by the proper authority.
1103 NEW ELECTRICAL WORK
For new electrical work the appropriate provisions of the
National Electrical Code shall be used as a guide for
design layout and installation. Not less than two general
lighting circuits (15 amp. ) and one appliance circuit (20
amp. ) shall be provided for each living unit. Heavy duty
equipment shall have individual branch circuits, as required
by the National Electrical Code.
The service entrance conductors and equipment shall have a
capacity adequate to serve the calculated load, plus capa-
city for additional circuits for future needs .
TWM:nw -41-
ORIGINAL111111
RESOLUTION NO. 80-16373
(Approving/adopting the property rehabil-
itation standards of the Community
Development Multi-Family Rehabilitation
Program)
• , •
f A
`4