Ordinance 2019-4315 Common Variances - Rooftop Additions, Setbacks (Including For Mixed-
Use Development), Room Sizes
ORDINANCE NO." 2019-4315
AN ORDINANCE OF THE MAYOR AND CITY COMMISSION OF THE CITY OF
MIAMI BEACH, FLORIDA, AMENDING THE LAND DEVELOPMENT
REGULATIONS OF THE CODE OF THE CITY OF MIAMI BEACH, BY
AMENDING CHAPTER 142, ENTITLED "ZONING DISTRICTS AND
REGULATIONS," ARTICLE II, ENTITLED "DISTRICT REGULATIONS,"
DIVISION 3, ENTITLED "RESIDENTIAL MULTIFAMILY DISTRICTS,"
SUBDIVISION II, ENTITLED "RM-1 RESIDENTIAL MULTIFAMILY LOW
INTENSITY," AT SECTIONS 142-155 AND 142-156, SUBDIVISION IV,
ENTITLED "RM-2 RESIDENTIAL MULTIFAMILY, MEDIUM INTENSITY," AT
SECTIONS 142-217 AND 142-218, AND SUBDIVISION V, ENTITLED "RM-3
RESIDENTIAL MULTIFAMILY, HIGH INTENSITY,"AT SECTIONS 142-246 AND
142-247, TO MODIFY SETBACK AND UNIT SIZE REQUIREMENTS FOR
ROOFTOP ADDITIONS TO CONTRIBUTING STRUCTURES IN HISTORIC
DISTRICTS AND INDIVIDUALLY DESIGNATED HISTORIC BUILDINGS;
DIVISION 4, ENTITLED "CD-1 COMMERCIAL, LOW INTENSITY DISTRICT,"
AT SECTIONS 142-276 AND 142-277, DIVISION 5, ENTITLED "CD-2
COMMERCIAL, MEDIUM INTENSITY DISTRICT," AT SECTIONS 142-306 AND
142-307, AND DIVISION 6, ENTITLED "CD-3 COMMERCIAL, HIGH INTENSITY
DISTRICT,"AT SECTIONS 142-337 AND 142-338, TO MODIFY SETBACK AND
UNIT SIZE REQUIREMENTS FOR RESIDENTIAL USES AND ROOFTOP
ADDITIONS TO CONTRIBUTING STRUCTURES IN HISTORIC DISTRICTS
AND INDIVIDUALLY DESIGNATED HISTORIC BUILDINGS, AND TO MODIFY
THE MAXIMUM ALLOWABLE HEIGHT FOR ALL USES; DIVISION 13,
ENTITLED "MXE MIXED USE ,ENTERTAINMENT DISTRICT," AT SECTION
142-545, TO MODIFY THE UNIT SIZE REQUIREMENTS FOR NEW HOTEL
UNITS FOR ROOFTOP ADDITIONS TO CONTRIBUTING STRUCTURES IN
HISTORIC DISTRICTS AND INDIVIDUALLY DESIGNATED HISTORIC
BUILDINGS, AND TO MODIFY THE MAXIMUM ALLOWABLE HEIGHT FOR
ALL USES; PROVIDING FOR REPEALER; SEVERABILITY; CODIFICATION;
AND AN EFFECTIVE DATE.
WHEREAS, the City of Miami Beach (the "City") has the authority to enact laws which
promote the public health, safety, and general welfare of its citizens; and
WHEREAS, the City has observed that a large number of variances from certain Code
sections are routinely sought in connection with land development applications; and
WHEREAS, the City has analyzed these variance applications, which are frequently
sought and granted; and
WHEREAS, the approval of such variances has no negative impact on surrounding areas;
and
WHEREAS, the City has determined that amendments to the land development
regulations to reduce the need for such variances are warranted; and
Page 1 of 21
WHEREAS, the amendments set forth below are necessary to accomplish all of the above
objectives.
NOW THEREFORE, BE IT ORDAINED BY THE MAYOR AND CITY COMMISSION OF
THE CITY OF MIAMI BEACH, FLORIDA.
Section 1. Chapter 142, entitled "Zoning Districts and Regulations," Article II, entitled "District
Regulations," at Division 3, entitled "Residential Multifamily Districts," is hereby amended as
follows:
CHAPTER 142 - ZONING DISTRICTS AND REGULATIONS
* * *
ARTICLE II. - DISTRICT REGULATIONS
DIVISION 3. - RESIDENTIAL MULTIFAMILY DISTRICTS
* * *
Subdivision II. - RM-1 Residential Multifamily Low Intensity
Sec. 142-155. - Development regulations and area requirements.
(a) The development regulations in the RM-1 residential multifamily, low density district are as
follows:
* * *
(b) The lot area, lot width, unit size and building height requirements for the RM-1 residential
multifamily, low density district are as follows:
Minimum Minimum Minimum Average Maximum
Lot Area Lot Unit Size Unit Size Building Height
(Square Width (Square Feet) (Square Feet) (Feet)
Feet) (Feet)
New construction-550 New construction— Historic district—
Non-elderly and elderly low and 800 40
moderate income housing-400 Non-elderly and Flamingo Park
Workforce housing-400 elderly low and Local Historic
Rehabilitated buildings-400 moderate income District-35
Hotel units: housing-400 (except as
5,600 50 15%: 300-335 Workforce provided in section
85%: 335+ housing-400 142-1161)
For contributing hotel Rehabilitated Otherwise-50
structures, located within an buildings-550, For properties
individual historic site, a local The number of outside a local
historic district or a national units may not historic district
register district, which are exceed the with a ground level
renovated in accordance with maximum density consisting of non-
Page 2 of 21
the Secretary of the Interior set forth in the habitable parking
Standards and Guidelines for comprehensive and/or amenity
the Rehabilitation of Historic plan. uses-55
Structures as amended,
retaining the existing room
configuration and sizes of at
least 200 square feet shall be
permitted. Additionally, the
existing room configurations for
the above described hotel
structures may be modified to
address applicable life-safety
and accessibility regulations,
provided the 200 square feet
minimum unit size is
maintained, and provided the
maximum occupancy per hotel
room does not exceed 4
persons.
Hotel units within rooftop
additions to contributing
structures in a historic district
and individually designated
historic buildings–200.
Sec. 142-156. - Setback requirements.
(a) The setback requirements for the RM-1 residential multifamily, low density district are as
follows:
Front Side, Side, Facing Rear
Interior a Street
Single lots
At-grade Single lots less than less than 65
feet in width:
parking lot on 65 feet in width: 5 5 feet, 5 feet abutting an
the same lot 20 feet feet, otherwise 10 otherwise 10 alley, otherwise
except where feet, or 8% of lot feet, or 8% of 10% of the lot depth
(c) below is width, whichever is
applicable greater lot width,
whichever is
greater
20 feet Single lots less than Single lots 10% of lot depth.
Except lots A 65 feet in width: 7.5 less than 65 Notwithstanding the
and 1-30 of the feet. feet in width: foregoing, rooftop
Subterranean Amended Plat Lots equal or greater 7.5 feet. additions to non-
and pedestal Indian Beach than 65 feet in width: Lots equal or oceanfront
Corporation Minimum 10 feet or greater than contributing
Subdivision and 8% of lot width, 65 feet in structures in a
lots 231-237 of whichever is greater, width: historic district and
Page 3of21
it
the Amended and sum of the side Minimum 10 individually
Plat of First yards shall equal 16% feet or 8% of designated historic
Ocean Front of lot width, lot width, buildings may follow
Subdivision-50 Notwithstanding the whichever is existing non-
feet foregoing, rooftop greater, and conforming rear
additions to sum of the pedestal setbacks.
contributing structures side yards
in a historic district shall equal
and individually 16% of lot
designated historic width
buildings may follow
existing non-
conforming side,
interior pedestal
setbacks.
20 feet + 1 foot The required pedestal
for every 1 foot setback plus 10% of
increase in the height of the tower o
height above 50 portion of the building. 15% of lot depth_
feet, to a The total required Notwithstanding the
maximum of 50 setback shall not Sum of the foregoing, rooftop
feet, then shall exceed 50 feet. side yards additions to non-
remain constant. - shall equal oceanfront
Except lots A Notwithstanding the 16% of the lot contributing
and 1-30 of the foregoing, rooftop width • structures in a
Tower Amended Plat additions to Minimum-10 historic district and
Indian Beach contributing structures feet or 8% of individually
Corporation in a historic district lot width, designated historic
Subdivision and and individually whichever is buildings may follow
lots 231-237 of designated historic greater existing non-
buildings may follow
the Amended existing non- conforming rear
Plat of First conforming side, pedestal setbacks.
Ocean Front interior pedestal
Subdivision-50 setbacks.
feet
Subdivision IV. - RM-2 Residential Multifamily, Medium Intensity
* * *
Sec. 142-217. -Area requirements.
The area requirements in the RM-2 residential multifamily, medium intensity district are as
follows:
Minimum Minimum Maximum
Lot Area Lot Minimum Average Building
(Square Width Unit Size Unit Size Height
Feet) (Feet) (Square Feet) (Square Feet) (Feet)
7,000 50 New construction-550 New construction— Historic district—
Non-elderly and elderly low and 800 50 (except as
Page 4of21
it
moderate income housing-400 Non-elderly and provided in section
Workforce housing-400 elderly low and 142-1161)
Rehabilitated buildings-400 moderate income Area bounded by
Hotel units: housing-400 Indian Creek Dr.,
15%: 300-335 Workforce Collins Ave., 26th
85%: 335+ housing-400 ' St., and 44th St.—
For contributing hotel Rehabilitated 75
structures, located within an buildings-550 Area fronting west
individual historic site, a local Hotel units—N/A, side of Collins
historic district or a national The number of Ave. btwn. 76th
register district, which are units may not St. and 79th St.—
renovated in accordance with exceed the 75
the Secretary of the Interior maximum density Area fronting west
Standards and Guidelines for set forth in the side of Alton Rd.
the Rehabilitation of Historic comprehensive between Arthur
Structures as amended, plan. Godfrey Rd. and
retaining the existing room W. 34th St.-85
configuration and sizes of at Otherwise-60
least 200 square feet shall be For properties
permitted. Additionally, the outside a local
existing room configurations for historic district
the above described hotel with a ground level
structures may be modified to consisting of non-
address applicable life-safety habitable parking
and accessibility regulations, I and/or amenity
provided the 200 square feet uses-65
minimum unit size is Lots fronting
maintained, and provided the Biscayne Bay less
maximum occupancy per hotel than 45,000 sq.
room does not exceed 4 ft.-100
persons. Lots fronting
Hotel units within rooftop Biscayne Bay over
additions to contributing 45,000 sq. ft.—
structures in a historic district 140
and individually designated Lots fronting
historic buildings–200. Atlantic Ocean
over 100,000 sq.
ft.-140
Lots fronting
Atlantic Ocean
with a property
line within 250 feet
of North Shore
Open Space Park
Boundary-200
Page 5 of 21
Sec. 142-218. - Setback requirements. 1
The setback requirements in the RM-2 residential multifamily, medium intensity district are
as follows:
Side, Side, Facing
Front Interior a Street Rear
Single lots
At-grade Single lots less than less than 65
parking lot on 65 feet in width: 5 feet in width: Abutting an alley-5
the same lot feet, otherwise 10 5 feet, feet
20 feet otherwise 10 Oceanfront lots-50
except where feet, or 8% of lot feet, or 8% of feet from bulkhead
(b) below is width, whichever is lot width, line
applicable greater
whichever is
greater
Single lots less than
65 feet: 7.5 feet Non-oceanfront
Lots equal or greater lots-10% of lot
than 65 feet in width: depth
Minimum 10 feet or Lots equal or Oceanfront lots-
20 feet 8% of lot width, 20% of lot depth, 50
Except lots A whichever is greater, greater than feet from the
and 1-30 of the and sum of the side 65 feet in bulkhead line
Amended Plat yards shall equal 16% width: whichever is greater.
Indian Beach of lot width_ Minimum 10 Notwithstanding the
Corporation Notwithstanding the feet or 8% of foregoing, rooftop
Subterranean Subdivision and foregoing, rooftop lot width, additions to non-
and pedestaladditions to whichever is
lots 231-237 of greater, and oceanfront
the Amended contributing contributing
Plat of First structures in a historic sum of the structures in a
Ocean Front district and side yards historic district and
Subdivision-50 individually shall equal individually
feet designated historic 16% of lot designated historic
buildings may follow width
buildings may follow
existing non- existing non-
conforming side, conforming rear
interior pedestal pedestal setbacks.
setbacks.
20 feet + 1 foot Same as pedestal for Non-oceanfront
for every 1 foot structures with a total Sum of the lots-15% of lot
increase in height of 60 feet or side yards depth
height above 50 less. shall equal Oceanfront lots—
feet, to a The required pedestal 16% of the lot 25% of lot depth, 75
Tower maximum of 50 setback plus 10% of width feet minimum from
feet, then shall the height of the Minimum-10 the bulkhead line
remain constant. tower portion of the feet or 8% of whichever is greater.
Except lots A building. The total lot width, Notwithstanding the
and 1-30 of the required setback shall whichever is foregoing, rooftop
Amended Plat not exceed 50 feet, greater additions to non-
Indian Beach Notwithstanding the oceanfront
Page 6 of 21
Corporation foregoing, rooftop contributing
Subdivision and additions to structures in a
lots 231-237 of contributing historic district and
the Amended structures in a historic individually
Plat of First district and designated historic
Ocean Front individually buildings may follow
Subdivision-50 designated historic existing non-
feet buildings may follow conforming rear
existing non- pedestal setbacks.
conforming side,
interior pedestal
setbacks.
* * *
Subdivision V. - RM-3 Residential Multifamily, High Intensity
* * *
Sec. 142-246. - Development regulations and area requirements.
(a) The development regulations in the RM-3 residential multifamily, high intensity district are
as follows:
* * *
(b) The lot area, lot width, unit size and building height requirements for the RM-3 residential
multifamily, high intensity district are as follows:
Minimum Minimum Minimum Average Maximum
Lot Area Lot Unit Size Unit Size Building Height
(Square Width (Square Feet) (Square Feet) (Feet)
Feet) (Feet)
New construction-550
Non-elderly and elderly low
and moderate income New
housing-400 construction-800
Workforce housing-400 Non-elderly and 150
Rehabilitated buildings-400 elderly low and
Hotel units: moderate income
15%: 300-335 housing-400 Oceanfront lots-200
85%: 335+ Workforce Architectural dist.:
For contributing hotel housing-400 New construction—
structures, located within an Rehabilitated 120; ground floor
7,000 50 individual historic site, a local buildings-550 additions (whether
historic district or a national Hotel units—N/Aattached or detached)
units—N/A,
register district, which are The number of to existing structures
renovated in accordance with units may not on oceanfront lots—
the Secretary of the Interior exceed the 50 (except as
Standards and Guidelines for maximum density provided in section
the Rehabilitation of Historic set forth in the 142-1161)
Structures as amended, comprehensive
retaining the existing room plan.
configuration and sizes of at
least 200 square feet shall
Page 7 of 21
be permitted. Additionally,
the existing room
configurations for the above
described hotel structures
may be modified to address
applicable life-safety and
accessibility regulations,
provided the 200 square feet
minimum unit size is
maintained, and provided the
maximum occupancy per
hotel room does not exceed
4 persons. Hotel units within
rooftop additions to
contributing structures in a
historic district and
individually designated
historic buildings–200.
Sec. 142-247. - Setback requirements.
(a) The setback requirements for the RM-3 residential multifamily, high intensity district are as
follows:
Side,
Front Side, Facing Rear
Interior a Street
5 feet, or Non-oceanfront lots—
At-grade 5 feet, or 5% of lot 5% of lot 5 feet
parking lot on 20 feet width, whichever is width, Oceanfront lots-50
the same lot greater whichever is feet from bulkhead
greater line
Sum of the side yards Non-oceanfront lots—
shall equal 16% of lot 10% of lot depth
20 feet width Oceanfront lots-20%
Except lots A. Minimum-7.5° feet or Sum of the of lot depth, 50 feet
and 1-30 of the 8% of lot width, side yards from the bulkhead line
Amended Plat whichever is greater, shall equal whichever is greater_
Indian Beach Notwithstanding the 16% of lot Notwithstanding the
Subterranean Corporation foregoing, rooftop width foregoing, rooftop
and pedestal Subdivision and additions to Minimum— additions to non-
lots 231-237 of contributing structures 7.5 feet or oceanfront
the Amended in a historic district and 8% of lot contributing structures
Plat of First individually designated width, in a historic district
Ocean Front historic buildings may whichever is and individually
Subdivision-50 follow existing non- greater designated historic
feet conforming side,
interior pedestal buildings may follow
setbacks. existing non-
Page 8 of 21
conforming rear
pedestal setbacks.
20 feet+ 1 foot
for every 1 foot The required pedestal Non-oceanfront lots—
increase in setback plus 10% of 15% of lot depth °
height above 50 the height of the tower Oceanfront lots-25/o
of lot depth, 75 feet
feet, to a portion of the building. Sum of the minimum from the
maximum of 50 The total required side yards bulkhead line
feet, then shall setback shall not shall equal whichever is greater,
remain constant. exceed 50 feet, 16% of the Notwithstanding the
Except lots A Notwithstanding the lot width foregoing, rooftop
and 1-30 of the foregoing, rooftop
Tower Amended Plat additions to Minimum— additions to non-
Indian Beach contributing structures 7.5 feet or oceanfront
Corporation in a historic district and ` 8% of lot contributing structures
Subdivision and individually designated width, in a historic district
lots 231-237 of historic buildings may
whichever is and individually
the Amended follow existing non- greater designated historic
buildings may follow
Plat of First conforming side, existing non-
Ocean Front interior pedestal conforming rear
Subdivision-50 setbacks.
feet pedestal setbacks.
Section 2. Chapter 142, entitled "Zoning Districts and Regulations," Article II, entitled "District
Regulations,"at Division 4, entitled "CD-1 Commercial, Low Intensity District," is hereby amended
as follows:
CHAPTER 142 - ZONING DISTRICTS AND REGULATIONS
* * *
ARTICLE II. - DISTRICT REGULATIONS
* * *
DIVISION 4. - CD-1 COMMERCIAL, LOW INTENSITY DISTRICT
* * *
Sec. 142-276. - Development regulations.
The development regulations in the CD-1 commercial, low intensity district are as follows:
Maximum Minimum Average Maximum
Floor Minimum Minimum Apartment Apartment Building
Area Lot Area Lot Width Unit Size Unit Size Height
Ratio (Square Feet) (Feet) (Square Feet) (Square Feet) (Feet)
Commercial Commercial 40 (except as
NI
Commercial Commercial N/A provided in
New New section 142-1161)
1.0 None None construction— construction— Notwithstanding
Residential Residential 550 800 the above, the
5,600 Rehabilitated Rehabilitated design review
buildings-400 buildings-550- board or historic
Page 9 of 21
li
Non-elderly Non-elderly and preservation
and elderly low elderly low and board, in
and moderate moderate accordance with
income income the applicable
housing-400 housing-400 review criteria,
Workforce Workforce may allow up to
housing-400 housing-400 an additional five
Hotel unit: Hotel units—N/_ feet of height, as
15%: 300— The number of measured from
335 units may not the base flood
85%: 335+ exceed the elevation plus
Hotel units maximum maximum
within rooftop density set forth freeboard, to the
additions to in the top of the second
contributing comprehensive floor slab. This
structures in a plan. provision shall not
historic district apply to existing
and historic districts or
individually existing overlay
designated districts (existing
historic j as of 7/26/2017),
buildings–200. or commercial
buildings
immediately
adjacent to
residential district
not separated by
a street. However,
an applicant may
seek approval
from the historic
preservation
boa e„ign
review hoard! as
may
applicable, to
increase height in
accordance with
the foregoing
district or overlay
district created
after 7/26/2017
Sec. 142-277. - Setback requirements.
(a) The setback requirements for the CD-1 commercial, low intensity district are as follows:
Page 10 of 21
Side, Side, Facing
Front Interior a Street Rear
At-grade 5 feet
parking lot on 5 feet 5 feet 5 feet If abutting an alley—
the same lot 0 feet
10 feet when 10 feet when
abutting a abutting a 5 feet
residential residential 10 feet when
district, district, unless abutting a
0 feet otherwise separated by a residential district
Subterranean, Residential Uses none street or unless separated by
pedestal and shall follow the RM Residential waterway a street or waterway
tower 1, 2, 3 setbacks uses shall otherwise none in which case it shall
(non- {See sections 142 follow the RM Residential uses be 0 feet.
shall-fellow-the Residential uses
oceanfront) 156, 142 218 and 1, 2, 3 RM 1, 2, 3 shall follow the RM
142 247) setbacks
setbacks
(See sections 1, 2, 3 setbacks(Se156, 142 (Sec sections (See sections 142
218 and 142 .142 156, 142 156, 142 218 and
218 and 142 142 247)
247) 3
Pedestal-15 feet
Tower-20 feet + 1 Commercial Commercial 25% of lot depth, 75
foot for every 1 foot uses 10 feet
uses 10 feet feet minimum from
increase in height Residential Residential Uses the bulkhead line
above 50 feet, to a uses shall
shall-fel-low-the whichever is greater
Pedestal and maximum of 50 feet, RM 1, 2, 3 Residential uses
tower then shall remain 1, 2, 3 setbacks shall follow the RM
(oceanfront) constant. Residential setbacks
uses shall follow the (Sec sections {See sections 1, 2, 3 setbacks
RM 1, 2, 3 setbacks 142 156, 142 142 156, 142 {See sections 142
(See sections 142 218 and 112 218 and 112 156, 142 218 and
156, 142 218 and 247-) 247142 247)
112 247)
(b) The tower setback shall not be less than the pedestal setback.
(c) Parking lots and garages: If located on the same lot as the main structure the above
setbacks shall apply. If primary use the setbacks are listed in subsection 142-1132(n).
(d) Mixed use buildings: Calculation of setbacks and floor area ratio:
residential or hotel units, any floor containing such units shall follow the RM 1, 2, 3
setback regulations:
(2) Floor area ratio. When more than 25 percent of the total area of a building is used for
residential or hotel units, the floor area ratio range shall be as set forth in the RM-1
district.
Page 11 of 21
Section 3. Chapter 142, entitled "Zoning Districts and Regulations," Article II, entitled "District
Regulations," at Division 5, entitled "CD-2 Commercial, Medium Intensity District," is hereby
amended as follows:
CHAPTER 142 - ZONING DISTRICTS AND REGULATIONS
ARTICLE II. - DISTRICT REGULATIONS
* * *
DIVISION 5. - CD-2 COMMERCIAL, MEDIUM INTENSITY DISTRICT
* * *
Sec. 142-306. - Development regulations. 1
The development regulations in the CD-2 commercial, medium intensity district are as 1
follows:
Maximum Minimum Minimum Minimum Average Maximum 1
Floor Apartment Apartment Building
Area Lot Area Lot Width Unit Size Unit Size Height
Ratio (Square Feet) (Feet) (Square Feet) (Square Feet) (Feet)
Commercial 50 (except as 1
N/A provided in
New section 142-
construction— Commercial 1161).
' 550 Notwithstanding
NIA
Rehabilitated the above, the
ew
buildings-400 construction—
Non-elderly c design review
and board or historic
80elderly low and Rehabilitated preservation
moderate board, in
income buildings-550 accordance with
housing-400 Non-elderly the applicable
Workforce and elderly low review criteria,
and moderate
Commercial Commercial housing-400 income may allow up to
None None Hotel unit: housing-400 an additional five
1.5 Residential Residential 15% 300— Workforce
/ofeet of height, as
88A 58 o 35 housing-400 measured from
85 : 335+ Hotel units— the base flood
For contributing NIAelevation plus
hotel structures, The number of maximum
located within units may not freeboard, to the
an individual exceed the top of the second
historic site, a floor slab. This
local historic maximum provision shall
district or a density set not apply to
forth in the
national register comprehensive existing historic
. districts or
district, which plan
are being existing overlay
renovated in districts (existing
accordance as of 7/26/2017),
with the or commercial
Page 12 of 21
Secretary of the buildings
Interior immediately
Standards and adjacent to
Guidelines for residential district
the not separated by
Rehabilitation of a street.
Historic However, an
Structures as applicant may
amended, seek approval
retaining the from the historic
existing room preservation
configuration board or design
shall be review board, as
permitted, may be
provided all applicable, to
rooms are a increase height in
minimum of 200 accordance with
square feet. the foregoing
Additionally, within any historic
existing room district or overlay
configurations district-created
for the above after 7/26/2017
described hotel Self-storage
structures may warehouse - 40
be modified to feet, except that
address the building
applicable life- height shall be
safety and limited to 25 feet
accessibility within 50 feet
regulations, from the rear
provided the property line for
200 square feet lots abutting an
minimum unit alley; and within
size is 60 feet from a
maintained, and residential district
provided the for blocks with no
maximum alley
occupancy per
hotel room does
not exceed 4
persons.
Hotel units
within rooftop
additions to
contributing
structures in a
historic district
and individually
designated
Page 13 of 21
historic
buildings–200.
Mixed-use and
commercial
buildings that
include structured
parking for
properties on the
west side of Alton
Road from 6th
Street to Collins
Canal - 60 feet.
Notwithstanding the above regulations, the maximum floor area ratio (FAR)for self-storage
warehouses shall be 1.5. The floor area ratio provision for mixed use buildings in section 142-
307(d)(2) shall not apply to self-storage warehouse development.
Sec. 142-307. - Setback requirements.
(a) The setback requirements for the CD-2 commercial, medium intensity district are as follows:
Side, Side, Facing
Front Interior a Street Rear
At-grade 5 feet
parking lot on 5 feet 5 feet 5 feet If abutting an alley-0
the same lot feet
10 feet when abutting 5 feet
a residential district, 10 feet when abutting
otherwise none 10 feet when a residential district
Residential uses shall abutting a unless separated by a
follow the RM 1, 2, 3 residential street or waterway in
setbacks district, unless which case it shall be
0 feet {See sections 1/12 separated by 0 feet. Residential
Residential 156, 112 218 and a street or uses shall follow the
-uses shall waterway RM 1, 2, 3 setbacks
Subterranean, follow the RM 142 247), otherwise (-Seetions nom_
pedestal and 1 2 3 Notwithstanding the none 156, 112 218 and
tower setbacks foregoing, rooftop Residential 1/12 2/17)
(non- {See sections additions to uses shall Notwithstanding the
oceanfront) 142 156, 1 42 contributing structures follow-the foregoing, rooftop
218 and 112 in a historic district RM 1, 2, 3 additions to non-
and individually setbacks oceanfront
designated historic (See sections contributing structures
buildings may follow 142 156, 142 in a historic district
existing non- 218 and 142 and individually
conforming side, designated historic
interior pedestal buildings may follow
setbacks. existing non-
Page 14 of 21
conforming rear
pedestal setbacks.
Pedestal-15 Commercial uses 10'.
feet feet
Tower-20 feet Residential uses shall
+ 1
every 1 footfoot for
follow the RM 1, 2, 3
setbacks
increase in (See sections 142 Commercial 25% of lot depth, 75
height above 156, 112 218 and user:, 10 feet feet minimum from
50 feet, to a Residential
142 217) the bulkhead line
Subterranean, maximum of 50 uses shall
Notwithstanding the whichever is greater
feet, then shall #sAsw##e
pedestal andforegoing, rooftop RM 1, Residential uses shall
tower remain additions to 2, 3 follow the RM 1, 2, 3
(oceanfront) constant. contributing structures setbacks
setbacks
Residential (See sections
in a historic district {See sections 112
uses shall and individually 112 156, 112 218 and 142 156, 142 218 and
follow the RM
1 2 3 designated historic 112 247)
setbacks buildings may follow
(See sections existing non-
142 156, 112 conforming side,
218 and 112 interior pedestal
setbacks.
247)
(b) The tower setback shall not be less than the pedestal setback.
(c) Parking lots and garages: If located on the same lot as the main structure the above
setbacks shall apply. If primary use the setbacks are listed in subsection 142-1132(n).
(d) Mixed use buildings: Calculation of setbacks and floor area ratio:
(1) - -- . - - - - - - - - -- - - - -- - - --• - -
residential or hotel units, any floor containing such units shall follow the RM 1, 2, 3
setback regulations.
(2) Floor area ratio. When more than 25 percent of the total area of a building is used for
residential or hotel units, the floor area ratio range shall be as set forth in the RM-2
district.
(23) The maximum floor area ratio (FAR) for self-storage warehouses shall be 1.5. The
floor area ratio provision for mixed use buildings in section 142-307(d)(2)above shall not
apply to self-storage warehouse development.
(e) Notwithstanding the above setback regulations, "self-storage warehouse"in this district shall
have the following setbacks:
(1) Front—Five feet;
(2) Side facing a street—Five feet;
(3) Interior side—Seven and one-half feet or eight percent of the lot width, whichever is
greater;
Page 15 of 21
(4) Rear—For lots with a rear property line abutting a residential district the rear yard
setback shall be a minimum of 25 feet; for lots with a rear property line abutting an alley
the rear setback shall be a minimum of seven and one-half feet.
Section 4. Chapter 142, entitled "ZoningDistricts and Regulations," Article II entitled "District
Regulations,"at Division 6, entitled"CD-3 Commercial, High Intensity District,"is hereby amended
as follows:
CHAPTER 142 -ZONING DISTRICTS AND REGULATIONS
* * *
ARTICLE II. - DISTRICT REGULATIONS
DIVISION 6. - CD-3 COMMERCIAL, MEDIUM INTENSITY DISTRICT
Sec. 142-337. - Development regulations and area requirements.
(a) The development regulations in the CD-3 commercial, high intensity district are as follows:
(1) Max FAR: Lot area equal to or less than 45,000 square feet-2.25; lot area greater than
45,000 square feet-2.75; oceanfront lots with lot area greater than 45,000 square feet-
3.0.
(2) Notwithstanding the above, oceanfront lots in architectural district shall have a
maximum FAR of 2.0.
(3) Notwithstandingthe above, lots located between Drexel Avenue and Collins Avenue
e
and between 16th Street and 17th Street shall have a maximum FAR of 2.75.
(4) Notwithstanding the above, lots which, as of the effective date of this ordinance
(November 14, 1998), are oceanfront lots with a lot area greater than 100,000 square
feet with an existing building, shall have a maximum FAR of 3.0; however, additional
FAR shall be available for the sole purpose of providing hotel amenities as follows: the
lesser of 0.15 FAR or 20,000 square feet.
(b) However, the floor area ratio maximum for residential development, inclusive of hotels, in
the architectural district shall be 2.50.
(c) The lot area, lot width, unit size and building height requirements for the CD-3 commercial,
high intensity district are as follows:
Minimum Minimum Minimum Average Maximum
Lot Area Lot Width Unit Size Unit Size Building
(Square Feet) (Feet) (Square Feet) (Square Feet) Height
(Feet)
Commercial N/A Commercial 75 feet.
New construction— A!/,4 Lots within the
550 New architectural district:
Commercial Commercial Rehabilitated construction— 50 feet.
None None buildings-400 800 Lots fronting on 17th
Residential Residential Non-elderly and Rehabilitated Street: 80 feet.
7,000 50 elderly low and buildings-550 City Center Area
moderate income Non-elderly and (bounded by Drexel
housing-400 elderly low and Avenue, 16th Street,
Workforce housing— moderate Collins Avenue and
Page 16 of 21
400 income the south property line
Hotel unit: housing-400 of those lots fronting
15%: 300-335 Workforce on the south side of
85%: 335+ housing-400 Lincoln Road): 100
For contributing Hotel units— feet.
hotel structures, N/A_ Notwithstanding the
located within an The number of above, the design
individual historic units may not review board or
site, a local historic exceed the historic preservation
district or a national maximum board, in accordance
register district, density set forth with the applicable
which are being in the review criteria, may
renovated in comprehensive allow up to an
accordance with the plan. additional five feet of
Secretary of the ; height, as measured
Interior Standards from the base flood
and Guidelines for elevation plus
the Rehabilitation of maximum freeboard,
Historic Structures to the top of the
as amended, second floor slab. This
retaining the existing provision shall not
room configuration apply to existing
shall be permitted, historic districts or
provided all rooms existing overlay
are a minimum of districts (existing as of
200 square feet. 7/26/2017), or
Additionally, existing commercial buildings
room configurations immediately adjacent
for the above to residential-district
described hotel not separated by a
structures may be street. However, an
modified to address applicant may seek
applicable life-safety approval from the
and accessibility historic preservation
regulations, provided board or design
the 200 square feet review board, as may
minimum unit size is be applicable, to
maintained, and increase height in
provided the
maximum foregoing within any
occupancy per hotel historic district or
room does not overlay district created
exceed 4 persons. after 7/26/2017
Hotel units within Notwithstanding the
rooftop additions to foregoing requirement
contributing for City Center Area,
structures in a the following
historic district and additional shall apply:
individually The height for lots
fronting on Lincoln
Page 17 of 21
designated historic Road and 16th Street
buildings–200. between Drexel
Avenue and
Washington Avenue
are limited to 50 feet
for the first 50' of lot
depth.
The height for lots
fronting on Drexel
Avenue is limited to 50
feet for the first 25' of
lot depth (except as
provided in section
142-1161).
Sec. 142-338. - Setback requirements.
(a) The setback requirements for the CD-3 commercial, high intensity district are as follows:
Front Side, Side, Facing Rear
Interior a Street
At-grade 5 feet
parking lot on 5 feet 5 feet 5 feet If abutting an alley-0
Y
the same lot feet
10 feet when abutting 5 feet
a residential district, 10 feet when 10 feet when abutting a
otherwise none abutting a residential district
Residential uses unless separated by a
shall follow the RM 1, residential street or waterway in
2, 3 setbacks district, which case it shall be 0
unless
0 feet {See sections 142 separated by feet. Residential uses
Residential 156, 112 218 and shall follow the RM 1,
uses shall 142 217) a street or ., 3 setbacks (See
Subterranean, follow the RM Notwithstanding the waterway sections 142 156, 112
pedestal and 1, 2, 3 foregoing, rooftop otherwise 218 and 112 247)
tower setbacks additions to none Notwithstanding the
(non- Residential
oceanfront) {See sections contributing uses shall foregoing, rooftop
142 156, 112 structures in a non-
fellow-the
+ho additions to non-
218 and 142 historic district and RM'�"�°2'3 oceanfront contributing
247 individually setbacks structures in a historic
designated historic {See sections district and individually
buildings may follow designated historic
existing non- 1'12 156, 142 buildings may follow
conforming side, 218 and 112 existing non-
interior pedestal conforming rear
setbacks. pedestal setbacks.
Subterranean, Pedestal-15 Commercial uses Commercial 25% of lot depth, 75
pedestal and feet 10 feet uses 10 feet feet minimum from the
Page 18 of 21
tower Tower-20 Residential uses Residential bulkhead line
(oceanfront) feet + 1 foot shall follow the RM 1, uses shall whichever is greater
for every 1 foot 2, 3 setbacks follow Residential uses shall
•
increase in (See sections 112 RM 1, 2, 3 follow the RM 1, 2, 3
height above 156, 142 218 and setbacks setbacks
50 feet, to a 142 247) (See sections (See sections 142 156,
maximum of Notwithstanding the 112 156, 112 142 218 and 112 247)
50 feet, then foregoing, rooftop 218 and 112
shall remain additions to 217)
constant. contributing
Residential structures in a
uses shall historic district and
follow the RM individually
1, 2, 3 designated historic
setbacks buildings may follow
(See sections existing non-
112 156, 112 conforming side,
218 and 112 interior pedestal
247-) setbacks.
(b) The tower setback shall not be less than the pedestal setback.
(c) Parking lots and garages: If located on the same lot as the main structure the above
setbacks shall apply. If primary use the setbacks are listed in subsection 142-1132(n).
(d) Mixed use buildings: Calculation of setbacks and floor area ratio:
•
setback regulations. 6
(2) Floor area ratio. When more than 25 percent of the total area of a building is used for
residential or hotel units, the floor area ratio range shall be as set forth in the RM-3
district.
Section 5. Chapter 142, entitled "Zoning Districts and Regulations," Article II, entitled "District
Regulations,"at Division 13, entitled "MXE Mixed Use Entertainment District," is hereby amended
as follows:
CHAPTER 142 -ZONING DISTRICTS AND REGULATIONS
ARTICLE II. - DISTRICT REGULATIONS
* * *
DIVISION 13. -MXE Mixed Use Entertainment District
* * *
Sec. 142-545. - Development regulations.
The development regulations in the MXE mixed use entertainment district are as follows:
Page 19 of 21
1
II
I
1
Minimum Minimum Minimum Average 1
Maximum Apartment Maximum
Lot Area Lot Apartment
Floor (Square Width Unit Size Unit Size Building Height 1
Area Ratio Feet) (Feet) (Square Feet) (Square (Feet) i
Feet) t
Existing Architectural district:
structures: Oceanfront-150 I
Apartment Non-oceanfront—
units-400 50 (except as provided in
Non-elderly and section 142-1161)
elderly low and All other areas-75
moderate (except as provided in
income section 142-1161) 1
I
housing-400 Notwithstanding the
Workforce above, the design review
housing-400 board or historic
Hotel units—in preservation board, in
a local historic Existing accordance with the 1
district/site— structures: applicable review criteria,
All uses-2.0 200 Apartment may allow up to an
Except Otherwise: units-550 additional five feet of
convention 15%: 300-335 Hotel units— height, as measured 1
hotel 85%: 335+ N/A from the base flood I
development N/A N/A New New elevation plus maximum
(as set forth in construction: construction: freeboard, to the top of
section 142- Apartment Apartment the second floor slab.
841)-3.5 units-550 units-800 This provision shall not
Hotel units: Hotel units— apply to existing historic
15%: 300-335 N/A districts or existing
85%: 335+ . overlay districts (existing
as of 7/26/2017), or
Hotel units GAM-Mere,jai-buildings
within rooftop immediately adjacent to
additions to residential district not
contributing separated by a street.
structures in a However, an applicant
• historic district may seek approval from
and individually the historic preservation
designated board or design review
' historic board, as may bo
buildings–200. applicable, to incr ace
height in accordance with
Page 20 of 21
I
the foregoing within Erni
historic district or overlay
district created after
7/26/2017
SECTION 6. Repealer.
All ordinances or parts of ordinances and all section and parts of sections in conflict
herewith are hereby repealed.
SECTION 7. Codification.
It is the intention of the City Commission, and it is hereby ordained that the provisions of
this ordinance shall become and be made part of the Code of the City of Miami Beach as
amended;that the sections of this ordinance may be renumbered or relettered to accomplish such
intention; and that the word "ordinance" may be changed to "section" or other appropriate word.
SECTION 8. Severability.
If any section, subsection, clause or provision of-'this Ordinance is held invalid, the
remainder shall not be affected by such invalidity.
SECTION 9. Effective Date.
This Ordinance shall take effect ten days following adoption.
PASSED AND ADOPTED this 30 ' day of -"- ''. , 2019.
,. ----:./P -' '._ __1___......_
Dan Gelber, Mayor
ATTE • ,
ivilmitv
/ I It r, j, _?,--���I ��!%,
Rafa I E. Gr.nado, City Clerk s ��+ ./ .%
z,;' '\107 0 APPROVED AS TO FORM
G ` AND LANGUAGE
- -;""•"144%„..,, = 1 AND FOR EXECUTION
'NC 0RP ORA 1 EL:' (— 16-
G_
' : \r:1,Ay Attorney Date
First Reading: •.tober 16, 019 \ P "••••• , i\�Second Reading: o. ober 30, '019 i ' ,:` _�.�_ "\C—
..-
Verified By: ii L
Thomas R. �ooney, Alf/1p
Planning Director
T:Wgenda\2019\10 October 16\Planning\Common Variance Requests-Ch 142 LDRs Heights Setbacks Unit Size-First Reading
ORD.docx
ii
Page 21 of 21
I
i
Ordinances - R5 C
MIAMI BEAH
COMMISSION MEMORANDUM
TO: Honorable Mayor and Members of the City Commission
FROM: Jimmy L. Morales, City Manager
DATE: October 30, 2019
5:04 p.m. Second Reading Public Hearing
SUBJECT: COMMON VARIANCES - ROOFTOP ADDITIONS, SETBACKS (INCLUDING
FOR MIXED-USE DEVELOPMENT), ROOM SIZES
AN ORDINANCE OF THE MAYOR AND CITY COMMISSION OF THE CITY
OF MIAMI BEACH, FLORIDA, AMENDING THE LAND DEVELOPMENT
REGULATIONS OF THE CODE OF THE CITY OF MIAMI BEACH, BY
AMENDING CHAPTER 142, ENTITLED "ZONING DISTRICTS AND
REGULATIONS," ARTICLE II, ENTITLED "DISTRICT REGULATIONS,"
DIVISION 3, ENTITLED "RESIDENTIAL MULTIFAMILY DISTRICTS,"
SUBDIVISION II, ENTITLED "RM-1 RESIDENTIAL MULTIFAMILY LOW
INTENSITY," AT SECTIONS 142-155 AND 142-156, SUBDIVISION IV,
ENTITLED "RM-2 RESIDENTIAL MULTIFAMILY, MEDIUM INTENSITY," AT
SECTIONS 142-217 AND 142-218, AND SUBDIVISION V, ENTITLED "RM-3
RESIDENTIAL MULTIFAMILY, HIGH INTENSITY," AT SECTIONS 142-246
AND 142-247, TO MODIFY SETBACK AND UNIT SIZE REQUIREMENTS
FOR ROOFTOP ADDITIONS TO CONTRIBUTING STRUCTURES IN
HISTORIC DISTRICTS AND INDIVIDUALLY DESIGNATED HISTORIC
BUILDINGS; DIVISION 4, ENTITLED "CD-1 COMMERCIAL, LOW
INTENSITY DISTRICT," AT SECTIONS 142-276 AND 142-277, DIVISION 5,
ENTITLED "CD-2 COMMERCIAL, MEDIUM INTENSITY DISTRICT," AT
SECTIONS 142-306 AND 142-307, AND DIVISION 6, ENTITLED "CD-3
COMMERCIAL, HIGH INTENSITY DISTRICT," AT SECTIONS 142-337 AND
142-338, TO MODIFY SETBACK AND UNIT SIZE REQUIREMENTS FOR
RESIDENTIAL USES AND ROOFTOP ADDITIONS TO CONTRIBUTING
STRUCTURES IN HISTORIC DISTRICTS AND INDIVIDUALLY
DESIGNATED HISTORIC BUILDINGS, AND TO MODIFY THE MAXIMUM
ALLOWABLE HEIGHT FOR ALL USES; DIVISION 13, ENTITLED "MXE
MIXED USE ENTERTAINMENT DISTRICT," AT SECTION 142-545, TO
MODIFY THE UNIT SIZE REQUIREMENTS FOR NEW HOTEL UNITS FOR
ROOFTOP ADDITIONS TO CONTRIBUTING STRUCTURES IN HISTORIC
DISTRICTS AND INDIVIDUALLY DESIGNATED HISTORIC BUILDINGS,
AND TO MODIFY THE MAXIMUM ALLOWABLE HEIGHT FOR ALL USES;
PROVIDING FOR REPEALER; SEVERABILITY; CODIFICATION; AND AN
EFFECTIVE DATE.
RECOMMENDATION
Page 307 of 849
The administration recommends that the City Commission adopt the subject ordinance.
BACKGROUND/HISTORY
On January 16, 2019, at the request of Commissioner John Elizabeth Aleman, the City
Commission referred the discussion item to the Land Use and Development Committee (Item
R9 T— 2.b). On April 3, 2019, the Land Use and Development Committee (LUDC) discussed
the item recommended that a comprehensive ordinance be drafted by the administration,
pursuant to the recommendations in the LUDC report, to streamline the code and development
processes, and that the City Commission refer the proposed ordinances to the Planning Board.
On May 8, 2019, the City Commission referred the proposed ordinance to the Planning Board
(item C4 Q).
ANALYSIS
PLANNING ANALYSIS
This ordinance is a companion to two other items on the agenda related to common variances
for"allowable encroachments" and "signage." Per Section 118-353 (d)of the land development
regulations of the city code, in order to authorize any variance from the terms of the land
development regulations, the applicable land use board must determine that there are "special
conditions and circumstances exist which are peculiar to the land, structure, or building involved
and which are not applicable to other lands, structures, or buildings in the same zoning district."
There are certain variances which are regularly requested and granted by the board of
adjustment, design review board, and historic preservation board. Rather than being the
exception to the rule, variance requests accompany most development proposals that are
presented before the boards. Several of the requests are quite common and usually granted by
the applicable board.
The attached ordinance addresses the following commonly issued variances:
1) Variance of minimum required side and rear setbacks for roof-top additions to historic
buildings to follow existing non-conforming side setbacks. Rooftop additions to historic
buildings must conform to new required setbacks. These variances are typically granted due to
the structural gymnastics that are required to setback a roof-top addition from the existing
building walls. The variances allow the additions to utilize existing structural supports of the
historic building.
The ordinance amends the RM-1, RM-2, RM-3, CD-1, CD-2, and CD-3 districts side and rear
setback requirements for rooftop additions to allow them to follow existing non-conforming
pedestal setbacks for contributing structures in a historic district and individually designated
historic building, subject to the certificate of appropriateness and rooftop addition criteria.
2)Variance for minimum and average unit size for rooftop additions to historic buildings. Historic
buildings may often have non-conforming units that are smaller than what can be built in a new
building. Variances are often sought for additions to historic buildings so that the size of new
units matches those of the original historic building in order to allow for continuation of historic
building lines in the new addition.
The ordinance amends the RM-1, RM-2, RM-3, CD-1, CD-2, and CD-3 districts minimum hotel
Page 308 of 849
unit size requirements for rooftop additions to historic buildings so that they are able to match
the size of the existing non-conforming building, provided it complies with the maximum density
requirements of the Comprehensive Plan.
3) Variance for setbacks of residential portions of mixed-use buildings in commercial districts.
Residential and hotel portions of mixed-use buildings in the CD-1, CD-2, and CD-3 districts are
required to follow the setbacks of the RM-1, RM-2, or RM-3 district, as applicable. Often these
setbacks are impractical in commercial districts, requiring desirable mixed-use buildings to seek
variances that a fully commercial building would not need.
The proposed ordinance removes the differing setback requirement for mixed-use buildings in
the CD-1, CD-2, and CD-3 districts. Mixed-use buildings would instead be required to follow
the existing setbacks for fully commercial buildings.
4) Variance for exceeding the maximum allowable height by a maximum of three feet for
commercial properties in historic districts. Within all commercial districts, the design review
board may allow up to an additional five feet of height, as measured from the base flood
elevation plus maximum freeboard, to the top of the second-floor slab. This section of the code
is designed to provide the Design Review Board (DRB)with the flexibility to allow for higher first
floor heights in order to accommodate future street and sidewalk elevations, as well as the
required slopes for ramps accessing upper level parking areas. However, this provision does
not apply to historic districts or overlay districts, nor to commercial buildings immediately
adjacent to a residential district not separated by a street. However, an applicant may seek a
height variance of not more than three feet from the historic preservation board.As a result, new
commercial construction seeking to elevate the first floor, and or provide parking at upper levels,
often request up to three-foot height variances, so that the project can maximize resiliency.
The proposed ordinance modifies height limits for CD-1, CD-2, and CD-3 districts to remove
the prohibition for five-foot increase in height at the first floor, currently permitted outside of
historic and overlay districts, so that such increases are permitted in commercial districts
citywide, including properties immediately adjacent to residential districts.
PLANNING BOARD REVIEW
On September 24, 2019, the Planning Board held a public hearing and transmitted the
ordinance to the City Commission with a favorable recommendation by a vote of 6-0.
HISTORIC PRESERVATION BOARD REVIEW
On October 8, 2019 the Historic Preservation Board (HPB) reviewed the subject ordinance and
recommended approval by a vote of 6-0. The HPB also recommended that the proposal to give
the HPB the authority to grant an additional five feet in height for projects in commercial districts
(which is currently allowed by the DRB outside of historic districts) be removed from the
ordiannce.
UPDATE
The subject ordinance was approved at first reading on October 16, 2019,with no changes.
CONCLUSION
Page 309 of 849
The administration recommends that the City Commission adopt the subject ordinance.
Applicable Area
Citywide
Is this a Resident Right to Does this item utilize G.O.
Know item? Bond Funds?
Yes No
Legislative Tracking
Planning
Sponsor
Commissioner John Elizabeth Aleman
ATTACHMENTS:
Description
o Form Approved ORD
Page 310 of 849