LTC 217-2021 Property Inspections of MBCDC Properties Conducted by MDCM IAMI BEACH OFFICE OF THE CITY MANAGER NO. LTC # LETTER TO COMMISSION TO: Mayor Dan Gelber and Memwers f the City Commission FROM: Alina T. Hudak, City Manag r DATE: May 20, 2021 SUBJECT: Property Inspections of MBCDC Properties Conducted by Miami-Dade County The purpose of this Letter To Commission is to transmit the property inspection reports of Miami Beach Community Development Corporation (MBCDC) properties conducted by Nan McKay and Associates as authorized by Miami-Dade County's Public Housing and Community Development Department. Attached you will find the Real Estate Assessment Center (REAC) reports for MBCDC- owned properties that were conducted by Nan McKay and Associates between April 26- May 7, 2021. Since 1998, the U.S. Department of Housing and Urban Development (HUD) has required physical inspections of all Section 8 housing, public housing, HUD-insured multifamily housing and all other HUD-assisted housing "utilizing a defined uniform physical condition standards to ensure that all housing is decent, safe, sanitary and in good repair." REAC scores, in addition to assessing the physical condition of properties, also establish the frequency that HUD properties will be subject to inspections: • A score of 90 to 100 is considered a great score and the property will be inspected every 3 years. • A score of 80 to 89 is considered a good score and the property will be inspected every 2 years. • A score of 79 or below means there were several areas of concern and the property will be inspected annually. One MBCDC-owned property in Miami Beach scored 80, Crespi Park Apartments. The remainder of the agency's properties within the City scored well below this threshold: • Jefferson Apartments ( 51 ) • Fernwood Apartments (55) • 1551 Pennsylvania Avenue (61) • Allen Apartments (62) • The Westchester (66) • 530-32 Michigan Avenue (67) • Meridian Apartments (68) • Villa Maria (71) • Villa Matti (74) The County also provided the following photos of the Jefferson Apartments: 217-2021 LTC # L T C # ---- Continued I I ·I "In general, based on REAC protocols, MBCDC is not doing a very good job of maintaining the properties. For 7 of the 11 properties, the average score is 61.4 out of a possible 100 points. 64.5% of the units in our portfolio are in these substandard/troubled buildings," said Michael Liu, Director of Miami-Dade County's Public Housing and Community Development Department. As a result of these reports, the City will be required to conduct re-inspections of those MBCDC properties assisted with City funds to ensure compliance with existing funding agreements. The properties with current City investment are: • Allen Apartments • Jefferson Apartments • Meridian Place • Villa Maria • The Westchester If City inspections support the findings within the County's reports, the City will be required to issue Notices of Default to MBCDC. In turn, MBCDC will be given an opportunity to cure each finding according to the terms of the funding agreement for each property (typically up to 30 days). Failure to cure the findings may trigger additional actions up to and including foreclosure action by the City. It should be noted that the City is recommending the award of Community Housing Development Organization (CHDO)/ HOME Investment Partnership funds in the amount of $30,796 to MBCDC as part of its federal funds allocation that will be coming to Commission for approval in June. These funds are to assist the agency in its CHOO operations which includes overall administrative support. LTC# ---- Continued MBCDC did not request capital or project funds during the 2021 HUD Funds Request For Proposals for any of the projects noted in the County's report and would be ineligible for HOME funds in any property previously receiving HOME funds that remains under affordability. The agency did submit a request for Community Development Block Grant (CDBG) funds for the rehabilitation of the Shel borne Apartments (which was not included in the County's property report). However, the U.S. Department of Housing and Urban Development (HUD) maintains a deed restriction on this property which prevents a funder from securing any grant funds or loans via mortgage subordination. As such, the property was ineligible for City funds. In addition, HUD has advised the City that MBCDC has not remedied the significant property conditions at the Shelborne that resulted in the building's closure and relocation of its tenants. HUD has advised the City that MBCDC has failed to cure conditions at the Shelborne and has not been responsive to HUD guidance in the resolution of this matter despite repeated assurances otherwise. If you have any questions, please see me or Maria Ruiz, Director, Office of Housing and Community Services. ATH/MM/MLR Enclosures: REAC Reports n a Nan McKay Jefferson Date 05/03/2021 Type Pre-REAC Area Pts.Lost(Raw) Site 14.77 Exterior 34.84 Systems 6.98 Common 26.02 Units 12.53 Total 95.13 *Pts. Lost(Adj.) Pts. Lost(Cap) Poss. Points 6.33 6.33 15 30.18 15 15 6.98 6.98 20 14.77 14.77 15 12.53 12.25 35 70.78 49.42 100 Score 51 Score Violations 8.67 5 o 8 13.03 1 0.23 12 28.65 30 50.58 56 "Pts. Lost (Raw) is the total point loss of all findings before the application of HUD scoring rules" ·Ps. Lost (Adj.) is the raw point loss adjusted for multiple findings of the same violation in the same building/unit per HUD rules" "Pts. Lost (Cap) is the adjusted point loss capped by the maximum possible point loss of each building/unit per HUD rules" Units Area Score is projected for the REAC sample size based on the average unit score" Entire Site Site Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed VEGETATION: Vegetation contacts unintended surface (not May 4 2021 Grounds Vegetation including minor contact with fence) 1 L2 2.11 11/404M(U1 ) / no visible damage VEGETATION: Vegetation contacts unintended surface (not May 4 2021 Grounds Vegetation 2 L2 2.11 11,484M(U1 including minor contact with fence) ) / no visible damage VEGETATION: Vegetation contacts unintended surface (not May 4 2021 Grounds Vegetation 3 L2 2.11 11/52AM(U1 including minor contact with fence) ) / no visible damage TRIPPING: Any obstruction or Rear building storm May 4 2021 Walkway/Steps Walkway/Steps defect in a surface that causes 4 L3 X NLT 4.22 11.55A4MU1 tripping drain ) TRIPPING: Any obstruction or Trip/cut hazard left side May 4 2021 Walkway/Steps Walkway/Steps defect in a surface that causes 5 L3 X NLT 4.22 11:58AM(U1 tripping of building ) Site Totals Violations: 5 Possible Pts.: 15 Pts. Lost: 6.328 (14.766 Raw/6.328 Adj./6.328 Cap) Pts. Retained: 8.672 Exterior Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Self closing device May 4 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or Elevator room 6 L3 X NLT 6.21 11:35A4M/U1 missing ) EGRESS: Emergency fire exit Right side of building will Entry Door Door - Security/Storm blocked/unusable - blocked 7 L3 X LT 10 May 4 2021 not open 3 25PM(U1) egress SHARP EDGES: Any defect that May 4 2021 Exterior Walls Walls could pose a cutting risk Front right gate 8 L3 X NLT 6.21 11.334M(U1 ) GUTTERS: Downspout May 4 2021 Roofing Downspout/Gutter splashblocks are 9 L1 1.55 11/34A4MU1 missing/damaged I GUTTERS: Downspout May 4 2021 Roofing Downspout/Gutter splashblocks are Right side of building 10 L-1 1.55 11/414M(U1 missing/damaged ) Powered By InspectCheck Mobile - Page 1/13 In sp e ct i o n R e s ul t s: Je ff e rs on - 0 5 /0 3 /2 0 2 1 (1 Exterior continued) Roofing Downspout/Gutter Roofing Downspout/Gutter Windows Window Seals/Sills GUTTERS: Downspout May 4 2021 splashblocks are Left side of building 11 L-1 1.55 11:494M(U1 missing/damaged I GUTTERS: Downspout May 4 2021 splashblocks are 12 L1 1.55 11.52A M/U1 missing/damaged I SHARP EDGES: Any defect that could pose a cutting risk Front of building 13 L3 May 42021 X NLT 6.21 1200PMut I Violations: 8 Possible Pts.: 15 1 Exterior Totals Pts. Lost: 15 (34.84 Raw/30.183 Adj./15 Cap) Pts. Retained: O Systems 1 Location Item Elevator Elevator Deficiency Notes Pic Sev HS LT Pts Date Fixed TRIPPING: Any obstruction or May 4 2021 defect in a surface that causes Second floor 14 L3 X NLT 6.98 12-.07PM(U1 tripping I Violations: 1 Possible Pts.: 20 1 Systems Totals Pts. Lost: 6.975 (6.975 Raw/6.975 Adj./6.975 Cap) Pts. Retained: 13.025 Common Area 1 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Closet/Utility/Mechanical Door - Entry/Fire/Bath General Comment No key 15 May 4 2021 2.35PM(01) HARDWARE: Self closing device May 4 2021 Closet/Utility/Mechanical Door - Entry/Fire/Bath on door not latching to close or 16 L3 3.38 2 22PM(01) missing HARDWARE: Self closing device Closet/Utility/Mechanical Door - Entry/Fire/Bath on door not latching to close or 17 L3 3.38 May 4 2021 223PM 0 1) missing COVERS: Outlet/switch has GFCI in elevator room May 4 2021 Closet/Utility/Mechanical Outlets/Switches broken/loose cover plate - no 18 L1 1.13 11:364Mu 1 exposed wires non op I COVERS: Outlet/switch has Closet/Utility/Mechanical Outlets/Switches broken/loose cover plate - no Electric meter room 19 L1 1.13 May 4 2021 2 21PM U1) exposed wires HARDWARE: Self closing device second floor inside May 4 2021 Halls/Corridors/Stairs Door - Entry/Fire/Bath on door not latching to close or staircase L3 3.38 228PM(01) missing HARDWARE: Self closing device first floor inside staircase Halls/Corridors/Stairs Door - Entry/Fire/Bath on door not latching to close or L3 3.38 May 4 2021 2 29PM(U1) missing HARDWARE: Self closing device Inside staircase 3rd floor Halls/Corridors/Stairs Door - Entry/Fire/Bath on door not latching to close or L3 3.38 May 4 2021 3:26PM(U1) missing Halls/Corridors/Stairs Lighting GLOBE: Light globe or Lens Outside stair case aux May 42021 missing or damaged lighting non op 219PM (U1) LIGHTING: 20-50% of permanent Outside stair case aux May 4 2021 Halls/Corridors/Stairs Lighting fixtures lighting non op 20 L2 2.25 2-19P M(U1) missing/damaged/inoperable HOLE: Hole/missing May 4 2021 Halls/Corridors/Stairs Walls tile/damaged/non-workmanlike Near entry door 21 L1 0.84 1132AM (U1 repair 1in.- 8.5x11in. I SHARP EDGES: Any defect that May 4 2021 Local Systems HVAC System Gap on roof top AC unit 22 L3 X NLT 3.38 1241PM U 1 could pose a cutting risk I na Powered By InspectCheck Mobile- Page 2/13 In s p e ct i o n R e s u lt s: J e ff er s o n - 0 5 /0 3 /2 0 2 1 (1 Common Area continued) Toilet loose at base in May 4 2021 Office Floor - Hard General Comment the shop 23 11/254MU1 I FIRE SAFETY: Smoke detector Smoke detector to fire May 4 2021 Office Smoke Detector inoperable/missing department covered 24 L3 X LT o 11.:294M(U1 l HOLE: Hole/missing Missing tile in the shop May 42021 Office Walls tile/damaged/non-workmanlike 25 L1 0.42 11.27AMU1 repair 1in.- 8.5x11in. bathroom I Violations: 12 Possible Pts.: 15 1 Common Area Totals Pts. Lost: 14.766 (26.016 Raw/14.766 Adj./14.766 Cap) Pts. Retained: 0.234 Unit 1 Unit 1-101 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit Occupancy Vacant unit - not rent ready May 4 2021 2 25PM(01) Violations: O Possible Pts.: 2.5 1 Unit 1-101 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.5 Unit 1 Unit 1-102 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit Occupancy Vacant unit - not rent ready May 4 2021 225PM(01) Violations: O Possible Pts.: 2.5 1 Unit 1-102 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.5 Unit 1 Unit 1-103 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit Occupancy Vacant unit - not rent ready May 4 2021 225PM(u1) Violations: O Possible Pts.: 2.5 Unit 1-103 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.5 Unit 1 Unit 1-104 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit Occupancy Vacant unit - not rent ready May 4 2021 2 25PM(01) Violations: O Possible Pts.: 2.5 1 Unit 1-104 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.5 Unit 1 Unit 1-105 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit Occupancy Vacant unit- not rent ready May 4 2021 2 25PM(01) na Powered By lnspectCheck Mobile - Page 3/13 In s p e c tio n R e s u lts : Je ff er s on - 0 5 /0 3 /2 0 2 1 (1 Unit 1-105 continued) Violations: O Possible Pts.: 2.5 1 Unit 1-105 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.5 Unit 1 Unit 1-106 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit Occupancy Vacant unit - not rent ready May 4 2021 2 26PM(U1) Violations: O Possible Pts.: 2.5 1 Unit 1-106 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.5 Unit 1 Unit 1-107 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit Occupancy Vacant unit - not rent ready May 4 2021 226PM(u1) Violations: O Possible Pts.: 2.5 1 Unit 1-107 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.5 Unit 1 Unit 1-200 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Sink HARDWARE: Sink has missing or damaged stopper or assembly L1 0.28 May 4 2021 1/33PM(U1) Violations: 1 Possible Pts.: 2.5 1 Unit 1-200 Totals Pts. Lost: 0.281 (0.281 Raw/0.281 Adj./0.281 Cap) Pts. Retained: 2.219 Unit 1 Unit 1-201 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit May 4 2021 148PM U1) Violations: O Possible Pts.: 2.5 1 Unit 1-201 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.5 Unit 1 Unit 1-202 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit May 4 2021 1.52PMU1) Violations: O Possible Pts.: 2.5 1 Unit 1-202 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.5 na Powered By InspectCheck Mobile - Page 4/13 In s p ect ion R e s u lts: Je ff er s on - 0 5 /0 3 /2 0 2 1 Unit 1 Unit 1-203 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Health & Safety Health & Safety INFESTATION - Insects 26 L3 X NLT 0.84 May 4 2021 159PMU1) Kitchen Cabinets CABINETS: Minor cabinet 27 May 4 2021 damage less than 1 O % 2.01PM(U1) Violations: 1 Possible Pts.: 2.5 1 Unit 1-203 Totals Pts. Lost: 0.844 (0.844 Raw/0.844 Adj./0.844 Cap) Pts. Retained: 1.656 Unit 1 Unit 1-204 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Sink HARDWARE: Sink has missing or L1 0.28 May 4 2021 damaged stopper or assembly 2.12PMU1) Bedroom 1 Walls WATER STAIN: Evidence of 28 L1 0.03 May 4 2021 leak/mold/mildew 4 sq in.- 1 sf 2:16PMU1) Violations: 2 Possible Pts.: 2.5 1 Unit 1-204 Totals Pts. Lost: 0.313 (0.313 Raw/0.313 Adj./0.313 Cap) Pts. Retained: 2.188 Unit 1 Unit 1-205 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed TRIPPING: Any obstruction or May 4 2021 Bathroom 1 Floor- Hard defect in a surface that causes 29 L3 X NLT o 2 09PM(U1) tripping HARDWARE: Bathroom 1 Shower/Tub - Hardware Missing/damaged/inoperable L1 0.21 May 4 2021 210PM(U1) stopper in bathtub/shower Violations: 2 Possible Pts.: 2.5 1 Unit 1-205 Totals Pts. Lost: 0.211 (0.211 Raw/0.211 Adj./0.211 Cap) Pts. Retained: 2.289 Unit 1 Unit 1-206 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Kitchen GFCI GFCI: Protected Outlet is missing near sink per local code May 4 2021 205PMU1) Violations: O Possible Pts.: 2.5 1 Unit 1-206 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.5 Unit 1 Unit 1-207 Location Item Deficiency Notes Bathroom 1 Sink HARDWARE: Sink has missing or damaged stopper or assembly Bedroom 1 Outlets/Switches OUTLET: Outlet/switch is Open ground missing/damaged HARDWARE: Self closing device Entry Door Door - Entry/Fire/Bath on door not latching to close or missing Pic Sev HS LT Pts Date Fixed L1 0.28 May 42021 154PM(01) 31 L3 0.23 May 4 2021 1.57PM(U1) L3 0.25 May 4 2021 1 53PM(U1) n1 an McKay Powered By InspectCheck Mobile - Page 5/13 Inspection Results: Jefferson - 05/03/2021 (1 Unit 1-207 continued) Violations: 3 Possible Pts.: 2.5 Unit 1-207 Totals Pts. Lost: 0.759 (0.759 Raw/0.759 Adj./0.759 Cap) Pts. Retained: 1. 7 41 Unit 1 Unit 1-208 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed TRIPPING: Any obstruction or May 4 2021 Bathroom 1 Floor- Hard defect in a surface that causes 32 L3 X NLT o 143PM (U1) tripping EXPOSED WIRES: Unsecured Bathroom 1 Lighting cover/wi res/con nections creating a 33 L3 X LT 1.88 May 4 2021 1/39PM (U1) hazard Bathroom 1 Walls HOLE: Hole/missing tile/damaged 34 L2 0.11 M a y 4 20 2 1 area more than 8.5x11in. 1.38P M U 1) Kitchen Ceiling CRACK: Crack > 1/8in. wide and 35 L-1 0.08 M a y 4 20 2 1 11in. long 1/4 2 PM (U 1) Kitchen GFCI GFCI: Protected Outlet is missing Both kitchen GFCI not 36 May 4 2021 near sink per local code protected 3 26PM(01) Living Room Smoke Detector FIRE SAFETY: Smoke detector L3 X LT o May 4 2021 inoperable/missing 144P M(U1) 1 Unit 1-208 Totals Violations: 5 Possible Pts.: 2.5 Pts. Lost: 2.063 (2.063 Raw/2.063 Adj./2.063 Cap) Pts. Retained: 0.438 Unit 1 Unit 1-209 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Health & Safety Health & Safety SHARP EDGES: Any defect that could pose a cutting risk L3 X NLT 0.84 May 4 2021 1.29PM (U1) Violations: 1 Possible Pts.: 2.5 1 Unit 1-209 Totals Pts. Lost: 0.844 (0.844 Raw/0.844 Adj./0.844 Cap) Pts. Retained: 1.656 Unit 1 Unit 1-300 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Toilet FIXTURE: Toilet is loose L2 0.94 May 4 2021 1 07PM (U1) Violations: 1 Possible Pts.: 2.5 1 Unit 1-300 Totals Pts. Lost: 0.938 (0.938 Raw/0.938 Adj./0.938 Cap) Pts. Retained: 1.563 Unit 1 Unit 1-301 Location Bathroom 1 Bathroom 1 Item Deficiency Notes Pic Sev HS LT Pts Date Fixed No access to bed room, May 42021 Door - Entry/Fire/Bath General Comment locked door 12.55PM (U1 I TRIPPING: Any obstruction or May 4 2021 Floor- Hard defect in a surface that causes 38 L3 X NLT o 12:57P M(UI tripping I na Powered By InspectCheck Mobile- Page 6/13 In sp e ction R e sul ts : Jef f er s o n - 0 5 /0 3 /2 0 2 1 (1 Unit 1-301 continued) CABINETS: 10-50% of May 4 2021 Kitchen Cabinets cabinets/doors/shelves missing or 39 L2 0.23 1257PM(U1 laminate is separating I LIGHT FIXTURES: Inoperable or May 4 2021 Kitchen Lighting Missing Lighting Fixture (One 40 L1 0.04 12.54PMU1 Room) ) SEALS: Damaged seals - window M ay 4 20 2 1 Kitchen Window Seals/Sills 41 L3 0.56 12.58P MU1 is missing caulk or glazing I Violations: 4 Possible Pts.: 2.5 1 Unit 1-301 Totals Pts. Lost: 0.834 (0.834 Raw/0.834 Adj./0.834 Cap) Pts. Retained: 1.666 Unit 1 Unit 1-302 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed GFCI: Outlet does not test or is M ay 4 20 2 1 Bathroom 1 GFCI not operating L3 X NLT 1.25 12:4 8P M(U 1 I HARDWARE: Sink has missing or M ay 4 20 2 1 Bathroom 1 Sink L1 0.28 12:48P M (U 1 damaged stopper or assembly ) GFCI: Outlet does not test or is M ay 4 20 2 1 Kitchen GFCI not operating 42 L3 X NLT 1.25 12.5 0P M U 1 ) FIRE SAFETY: Smoke detector M ay 4 20 2 1 Living Room Smoke Detector inoperable/missing L3 X LT o 12,4 9P M (U 1 ) Violations: 4 Possible Pts.: 2.5 1 Unit 1-302 Totals Pts. Lost: 2.5 (2.781 Raw/2.781 Adj./2.5 Cap) Pts. Retained: O Unit 1 Unit 1-303 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Kitchen GFCI GFCI: Protected Outlet is missing near sink per local code M a y 4 20 2 1 12.3 1P M (U 1 ) Violations: O Possible Pts.: 2.5 Unit 1-303 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.5 Unit 1 Unit 1-304 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed CABINETS: Minor cabinet M ay 4 20 2 1 Kitchen Cabinets damage less than 1 0 % 44 12:18P M (U 1 ) COVERS: Outlet/switch has M ay 4 20 2 1 Living Room Outlets/Switches broken/loose cover plate - no 45 L1 0.06 12 .17P M(U 1 exposed wires I Violations: 1 Possible Pts.: 2.5 1 Unit 1-304 Totals Pts. Lost: 0.056 (0.056 Raw/0.056 Adj./0.056 Cap) Pts. Retained: 2.444 na Nan McKay Powered By InspectCheck Mobile - Page 7/13 Inspection Results: Jefferson - 05/03/2021 Unit 1 Unit 1-305 Location Item Bathroom 1 Sink Deficiency Notes Pic Sev HS LT Pts Date Fixed LEAK: A slow leak or drip in basin/sink/associated piping - L1 0.28 May 4 2021 1.24PMU1) fixture still functions Violations: 1 Possible Pts.: 2.5 1 Unit 1-305 Totals Pts. Lost: 0.281 (0.281 Raw/0.281 Adj./0.281 Cap) Pts. Retained: 2.219 Unit 1 Unit 1-306 Location Item Deficiency Notes Bathroom 1 Floor - Hard TRIPPING: Any obstruction or defect in a surface that causes tripping Kitchen GFCI GFCI: Protected Outlet is missing near sink per local code Pic Sev HS LT Pts Date Fixed May 4 2021 46 L3 X NLT o 1227PMU1 ) May 4 2021 12.26PMU1 ) Violations: 1 Possible Pts.: 2.5 1 Unit 1-306 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.5 Unit 1 Unit 1-307 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No Issues/Violations No observed deficiencies in entire unit M ay 4 2021 12:38PM(U1 ) Violations: O Possible Pts.: 2.5 1 Unit 1-307 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.5 Unit 1 Unit 1-308 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Kitchen GFCI GFCI: Outlet does not test or is not operating 47 L3 X NLT 1.25 M ay 4 2021 1.03PM(01) Violations: 1 Possible Pts.: 2.5 1 Unit 1-308 Totals Pts. Lost: 1.25 (1.25 Raw/1.25 Adj./1.25 Cap) Pts. Retained: 1.25 Unit 1 Unit 1-309 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Health & Safety Health & Safety SHARP EDGES: Any defect that 48 L3 X NLT 0.84 May 4 2021 could pose a cutting risk 1.09PM(U1) CABINETS: 10-50% of Kitchen Cabinets cabinets/doors/shelves missing or 49 L2 0.23 May 42021 1/13PM(01) laminate is separating Violations: 2 Possible Pts.: 2.5 1 Unit 1-309 Totals Pts. Lost: 1.078 (1.078 Raw/1.078 Adj./1.078 Cap) Pts. Retained: 1.422 na Nan M'Kay Powered By lnspectCheck Mobile- Page 8/13 Inspection Results: Jefferson - 05/03/2021 Inspection Photos Entire Site Site - Grounds Vegetation - 4 Site - Walkway/Steps Walkway/Steps - Rear building storm drain 2 Site - Grounds Vegetation - 3 Site - Grounds Vegetation - 5 Site - Walkway/Steps Walkway/Steps - Trip/cut hazard left side of building Exterior 6 1-Entry Door Door - Entry/Fire/Bath - Elevator room 7 1- Entry Door Door - Security/Storm - Right side of building will not open 8 1- Exterior Walls Walls - Front right gate na Nan MKay Powered By lnspectCheck Mobile - Page 9/13 Inspection Results: Jefferson - 05/03/2021 (Exterior continued) 9 1-Roofing Downspout/Gutter - 10 1- Roofing Downspout/Gutter - Right side of building 11 1- Roofing Downspout/Gutter - Left side of building 12 1 - Roofing Downspout/Gutter - 13 1-Windows Window Seals/Sills - Front of building Systems 14 1- Elevator Elevator - Second floor na Powered By lnspectCheck Mobile - Page 10/13 Inspection Results: Jefferson - 05/03/2021 Common Area 15 1- Closet/Utility/Mechanical Door - Entry/Fire/Bath - No key 18 1- Closet/Utility/Mechanical Outlets/Switches - GFCI in elevator roo m non op 21 1- Halls/Corridors/Stairs Walls - Near entry door 24 1- Office Smoke Detector - Smoke detector to fire departm ent covered 16 1- Closet/Utility/Mechanical Door - Entry/Fire/Bath - 19 1- Closet/Utility/Mechanical Outlets/Switches - Electric meter room 22 1-Local Systems HVAC System - Gap on roof top AC unit 17 1- Closet/Utility/Mechanical Door - Entry/Fire/Bath - 20 1- Halls/Corridors/Stairs Lighting - Outside stair case aux lighting non op 23 1- Office Floor - Hard - Toilet loose at base in the shop 25 1- Office W alls - Missing tile in the shop bathroom na Powered By lnspectCheck Mobile - Page 11/13 Inspection Results: Jefferson - 05/03/2021 Unit 26 Unit 1-203 - Health & Safety Health & Safety - 29 1 Unit 1-205 - Bathroom 1 Floor - Hard - 32 Unit 1-208 - Bathroom 1 Floor - Hard - 35 Unit 1-208 - Kitchen Ceiling- 1 Unit 1-203 - Kitchen Cabinets - 30 Unit 1-206 - Kitchen GFCI- 33 Unit 1-208 - Bathroom 1 Lighting- 36 1 Unit 1-208 - Kitchen GFCI- Both kitchen GFCI not protected 28 Unit 1-204 - Bedroom 1 Walls - 31 1 Unit 1-207 - Bedroom 1 Outlets/Switches - Open ground 34 Unit 1-208 - Bathroom 1 Walls- 37 Unit 1-209 - Health & Safety Health & Safety - na Powered By lnspectCheck Mobile- Page 12/13 Inspection Results: Jefferson - 05/03/2021 (Unit continued) 38 Unit 1-301 - Bathroom 1 Floor - Hard - 41 Unit 1-301 - Kitchen Window Seals/Sills - 44 Unit 1-304 - Kitchen Cabinets - 39 Unit 1-301 - Kitchen Cabinets - 42 Unit 1-302 - Kitchen GFCI- 45 Unit 1-304 - Living Room Outlets/Switches - 40 Unit 1-301 - Kitchen Lighting- 43 1 Unit 1-303 - Kitchen GFCI- 46 Unit 1-306 - Bathroom 1 Floor - Hard - 47 Unit 1-308 - Kitchen GFCI- 48 Unit 1-309 - Health & Safety Health & Safety - 49 Unit 1-309 - Kitchen Cabinets - na Powered By lnspectCheck Mobile- Page 13/13 n a Nan McKay A Fernwood Date 04/26/2021 Type Pre-REAC Area *Pts.Lost(Raw) Pts. Lost(Adj.) *Pts. Lost(Cap) Poss. Points Site o o o 15 Exterior 8.45 8.45 8.45 15 Systems 12 12 12 20 Common 18.61 18.61 15 15 *Units 21.76 21.76 16.26 35 Total 60.82 60.82 45.39 100 Score 55 Score Violations 15 o 6.55 2 8 2 o 6 25.06 25 54.61 35 ·Pts. Lost (Raw) is the total point loss of all findings before the application of HUD scoring rules' ·Ps. Lost (Adj.) is the raw point loss adjusted for multiple findings of the same violation in the same building/unit per HUD rules' ·Ps. Lost (Cap) is the adjusted point loss capped by the maximum possible point loss of each building/unit per HUD rules" Units Area Score is projected for the REAC sample size based on the average unit score" Exterior 1 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Foundation Foundation CRACK: Cracks/gaps > 1 /Bin. w x missing right side L2 6.9 Apr 27 2021 1/Bin.d x 6in.l foundation vent cover. 8:164Mu1) GUTTERS: Downspout Right side splash block Apr 27 2021 Roofing Downspout/Gutter splashblocks are missing. L1 1.55 6:.554M(01) missing/damaged Violations: 2 Possible Pts.: 15 1 Exterior Totals Pts. Lost: 8.453 (8.453 Raw/8.453 Adj./8.453 Cap) Pts. Retained: 6.548 Systems 1 Location Electrical System Emergency Power Item Deficiency Notes Pic Sev HS LT Pts Date Fixed EXPOSED WIRES: Any missing electrical cover Apr 27 2021 Electric Panel loose/unsecured section of a in matinance room. L3 X LT 10 6.314MU1) panel cover Auxiliary Lighting EMERGENCY POWER: Auxiliary Tes ting function non op. 1 L3 X NLT 2 Apr 27 2021 light damaged or inoperable 7.09A4MU1) Violations: 2 Possible Pts.: 20 1 Systems Totals Pts. Lost: 12 (12 Raw/12 Adj./12 Cap) Pts. Retained: 8 Common Area 1 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Halls/Corridors/Stairs Door - Interior HARDWARE: Interior door Door to staircase first L2 1.69 Apr 27 2021 hardware damaged/ inoperable floor latch hardware. 6:284MU1) EXPOSED WIRES: Unsecured Missing cover on aux Halls/Corridors/Stairs Lighting cover/wires/connections creating a lighting, second floor 2 L3 X LT 7.5 Apr 27 2021 7-12AM01) hazard staircase. Laundry Room Ceiling HOLE: Hole and/or damaged area L2 2.25 Apr 27 2021 on ceiling > 8.5in. x 11 in. 6:33AM(U1) HARDWARE: Self closing device Apr 27 2021 Laundry Room Door - Entry/Fire/Bath on door not latching to close or L3 3.38 6:344Mu1) missing Powered By InspectCheck Mobile- Page 1/8 In sp e ct i o n R e s ul ts: F er n w o o d - 04 /2 6/2 0 2 1 (1 Common Area continued) Laundry Room Lobby Door - Entry/Fire/Bath Outlets/Switches HARDWARE: Panic Hardware on door inoperable COVERS: Outlet/switch has broken/loose cover plate - no exposed wires cracked cover plate in office. L3 L1 3.38 0.42 Ar 27 2021 6.34A4MU1) Apr 27 2021 6.40A4M(U1) Violations: 6 Possible Pts.: 15 1 Common Area Totals Pts. Lost: 15 (18.609 Raw/18.609 Adj./15 Cap) Pts. Retained: O Unit 1 Unit 103 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No Issues/Violations No observed deficiencies in entire unit Apr 27 2021 10:32A4MU1 ) Violations: O Possible Pts.: 3.182 1 Unit 103 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 3.182 Unit 1 Unit 104 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Ceiling WATER STAIN: Evidence of 3 L1 0.04 Apr 27 2021 leak/mold/mildew 4 sq in.- 1sf 6:49A4M(u1) Bathroom 1 Ventilation/Exhaust EXHAUST: Exhaust fan not L2 0.72 Apr 27 2021 functioning 6.504Mu1) TRIPPING: Any obstruction or broken floor tile trip Apr 27 2021 Kitchen Floor- Hard defect in a surface that causes hazard. L3 X NLT o 6:.464Mu1) tripping Violations: 3 Possible Pts.: 3.182 1 Unit 104 Totals Pts. Lost: 0.756 (0.756 Raw/0.756 Adj./0.756 Cap) Pts. Retained: 2.426 Unit 1 Unit 106 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed EXPOSED WIRES: Unsecured Bathroom 1 Lighting cover/wires/connections creating a 4 L3 X Lr 2.39 Apr 27 2021 7.044MU1) hazard Kitchen GFCI GFCI: Outlet does not test or is L3 X NLT 1.59 Apr 27 2021 not operating 7.04AM(U1) COVERS: Outlet/switch has Living Room Outlets/Switches broken/missing cover plate - 5 L3 X LT 2.39 Apr 27 2021 7.03A4MU1) exposing wires Violations: 3 Possible Pts.: 3.182 1 Unit 106 Totals Pts. Lost: 3.182 (6.364 Raw/6.364 Adj./3.182 Cap) Pts. Retained: O Unit 1 Unit 107 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bedroom 1 Smoke Detector FIRE SAFETY: Smoke detector inoperable/missing L3 X LT o Apr 27 2021 6.58A4Mu1) na Nan McKay Powered By lnspectCheck Mobile - Page 2/8 Insp ection R esul ts: Fer w ood - 04/26/2021 (1 Unit 107 continued} Bedroom 2 Smoke Detector FIRE SAFETY: Smoke detector inoperable/missing L3 X LT o Ar 27 2021 6.584MU1) Violations: 2 Possible Pts.: 3.182 1 Unit 107 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 3.182 Unit 1 Unit 201 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit Apr 27 2021 10.32AM(U1 I Violations: O Possible Pts.: 3.182 1 Unit 201 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 3.182 Unit 1 Unit 202 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Kitchen Stove/Range OVEN: Oven and/or broiler element does not function L3 1.07 Apr 27 2021 7.20AMU1) Violations: 1 Possible Pts.: 3.182 1 Unit 202 Totals Pts. Lost: 1.074 (1.074 Raw/1.074 Adj./1.074 Cap) Pts. Retained: 2.108 Unit 1 Unit 203 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit Apr 27 2021 10.32AM(U1 ) Violations: O Possible Pts.: 3.182 1 Unit 203 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 3.182 Unit 1 Unit 204 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed COVERS: Outlet/switch has Bedroom 1 Outlets/Switches broken/missing cover plate - L3 X LT 2.39 Apr 27 2021 7.30AMU1) exposing wires Violations: 1 Possible Pts.: 3.182 1 Unit 204 Totals Pts. Lost: 2.386 (2.386 Raw/2.386 Adj./2.386 Cap) Pts. Retained: 0.795 Unit 1 Unit 205 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit Apr 27 2021 10:334MU1 ) Violations: O Possible Pts.: 3.182 1 Unit 205 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 3.182 na Nan McKay Powered By lnspectCheck Mobile- Page 3/8 In sp e ct ion R e s u lts: F er w o o d - 0 4 /2 6 /2 0 2 1 Unit 1 Unit 206 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bedroom 1 Smoke Detector FIRE SAFETY: Smoke detector inoperable/missing L3 X LT o Apr 27 2021 7.32AM01) Violations: 1 Possible Pts.: 3.182 1 Unit 206 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 3.182 Unit 1 Unit 207 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed LEAK: A slow leak or drip in Apr 27 2021 Bathroom 1 Shower/Tub - Hardware basin/sink/associated piping - tub constaint drip. L1 0.36 7:44A4MU1) fixture still functions HARDWARE: Shower/bathtub Bathroom 1 Shower/Tub - Hardware cannot be used due to failed shower head non op. L3 1.07 Apr 27 2021 7:.454MU1) hardware DRAIN: clogged partially, Ar 27 2021 Bathroom 1 Sink sink/basin does not drain freely L 1 0.6 7.:394MU1) but still functions FLOOR COVERING: 5-10% of Bedroom 1 Floor- Hard hard floor shows wear/stains/dam L1 0.1 Ar 27 2021 age/non-workmanlike repairs 7414MU1) COVERS: Outlet/switch has Bedroom 1 Outlets/Switches broken/loose cover plate - no L1 0.07 Apr 27 2021 7:414MU1) exposed wires Local Systems HVACSystem HVAC: HVAC system vibrating/ AC is leaking. L3 1.43 Apr 27 2021 noisy/ leaking - still functioning 7:464MU1) 1 Unit 207 Totals Violations: 6 Possible Pts.: 3.182 Pts. Lost: 3.182 (3.627 Raw/3.627 Adj./3.182 Cap) Pts. Retained: O Unit 1 Unit 301 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Kitchen GFCI GFCI: Protected Outlet is missing 2 outlets need GFCI near sink per local code near sink. Apr 27 2021 8:144M(U1) Violations: O Possible Pts.: 3.182 1 Unit 301 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 3.182 Unit 1 Unit 302 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Shower/bathtub Bathroom 1 Shower/Tub - Hardware cannot be used due to failed Shower handel is loose. L3 1.07 Apr 27 2021 8:10AM/01) hardware Bathroom 1 Shower/Tub - Stall SHARP EDGES: Any defect that 6 L3 X NLT 1.07 Apr 27 2021 could pose a cutting risk 8.094M (U1) Violations: 2 Possible Pts.: 3.182 1 Unit 302 Totals Pts. Lost: 2.148 (2.148 Raw/2.148 Adj./2.148 Cap) Pts. Retained: 1.034 n1 Nan McKay Powered By lnspectCheck Mobile- Page 4/8 Inspection Results: Femwood - 04/26/2021 Unit 1 Unit 303 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No Issues/Violations No observed deficiencies in entire unit Apr 27 2021 10:334M(U1 I Violations: O Possible Pts.: 3.182 1 Unit 303 Totals Pts. Lost: O (O Raw/O Adj.JO Cap) Pts. Retained: 3.182 Unit 1 Unit 304 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit Apr 27 2021 10.334M/U1 I Violations: O Possible Pts.: 3.182 1 Unit 304 Totals Pts. Lost: O (O Raw/O Adj.JO Cap) Pts. Retained: 3.182 Unit 1 Unit 305 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 GFCI GFCI: Outlet does not test or is L3 X NLT 1.59 Apr 27 2021 not operating 8.004M U1) HARDWARE: Shower/bathtub Bathroom 1 Shower/Tub - Hardware cannot be used due to failed Tub diverter non op. L3 1.07 Ar 27 2021 8.01AM(U1) hardware COVERS: Outlet/switch has Bedroom 1 Outlets/Switches broken/missing cover plate - L3 X LT 2.39 Apr 27 2021 7-59A4MU1) exposing wires Violations: 3 Possible Pts.: 3.182 1 Unit 305 Totals Pts. Lost: 3.182 (5.051 Raw/5.051 Adj./3.182 Cap) Pts. Retained: O Unit 1 Unit 306 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit Apr 27 2021 10.334M/U1 ) Violations: O Possible Pts.: 3.182 1 Unit 306 Totals Pts. Lost: O (O Raw/O Adj.JO Cap) Pts. Retained: 3.182 Unit 1 Unit 307 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bedroom 1 Ceiling HOLE: Hole and/or damaged area closet bedroom and L2 0.19 Apr 27 2021 on ceiling > 8.5in. x11in. living room 7.52A4MU1) Bedroom 1 Ceiling WATER STAIN: Evidence of closet bedroom and L3 0.16 Apr 27 2021 leak/mold/mildew> 4sf living room 7:52AM(U1) Bedroom 1 Smoke Detector FIRE SAFETY: Smoke detector L3 X LT o Apr 27 2021 inoperable/missing 7.504M U1) Nan McKay Powered By lnspectCheck Mobile- Page 5/8 Inspection Results: Ferwood - 04/26/2021 (1 Unit 307 continued) Violations: 3 Possible Pts.: 3.182 1 Unit 307 Totals Pts. Lost: 0.35 (0.35 Raw/0.35 Adj./0.35 Cap) Pts. Retained: 2.832 Nan McKay Powered By lnspectCheck Mobile- Page 6/8 Inspection Results: Ferwood - 04/26/2021 Inspection Photos Systems 1-Emergency Power Auxiliary Lighting - Testing function non op. Common Area 2 1- Halls/Corridors/Stairs Lighting - Missing cover on aux lighting, second floor staircase. Unit à 3 Unit 104 - Bathroom 1 Ceiling- 4 Unit 106 - Bathroom 1 Lighting- Unit 106 -Living Room Outlets/Switches - na Nan McKay Powered By lnspectCheck Mobile- Page 718 Inspection Results: Fernwood - 04/26/2021 (Unit continued) 6 U nit 302 - Bathroom 1 Shower/Tub - Stall - Powered By InspectCheck Mobile- Page 8/8 na Nan McKay • » 1551 Pennsylvania Date 04/27/2021 Type Pre-REAC Area Pts.Lost(Raw) Pts. Lost(Adj.) *Pts. lost(Cap) Poss. Points Site 3.16 3.16 3.16 15 Exterior 23.11 23.11 15 15 Systems o o o 20 Common 9.19 9.19 9.19 15 *Units 21.28 21.28 19.21 35 Total 56.74 56.74 38.88 100 Score 61 Score Violations 11.84 2 o 3 20 o 5.81 2 23.47 43 61.12 50 "Pts. Lost (Raw) is the total point loss of all findings before the application of HUD scoring rules" ·Ps. Lost (Adj.) is the raw point loss adjusted for multiple findings of the same violation in the same building/unit per HUD rules' "Pts. Lost (Cap) is the adjusted point loss capped by the maximum possible point loss of each building/unit per HUD rules" "Units Area Score is projected for the REAC sample size based on the average unit score Entire Site Site Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Grounds Vegetation VEGETATION: Vegetation contacts unintended surface (not including minor contact with fence) / no visible damage Walkway/Steps Walkway/Steps SPALLING: More than 5% of walkways spalling 4x4in. or less left side, left front and right front of building. Cracked, broken concrete walkways. L2 2.11 Apr 26 2021 2.09PMU1) L1 Violations: 2 Possible Pts.: 15 Site Totals Pts. Lost: 3.164 (3.164 Raw/3.164 Adj./3.164 Cap) Pts. Retained: 11.836 Exterior Location Electrical Entry Door Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Electric Panel EXPOSED WIRES: Gap of 1/4in. located in the rear of L3 X LT 10 Apr 26 2021 or more in a breaker row/panel building. 2.13PMU1) Door - Security/Storm HARDWARE: Security door back exit auto closing L3 X NLT 6.21 Apr 26 2021 hardware, or other damage hardware non op. 217PMU1) Foundation Foundation CRACK: Cracks/gaps > 1/8in.w x missing foundation vent 1/8in.dx 6in.l on ride side of building. L2 Violations: 3 Possible Pts.: 15 1 Exterior Totals Pts. Lost: 15 (23.11 Raw/23.11 Adj./15 Cap) Pts. Retained: O Common Area 1 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed EXPOSED WIRES: Unsecured missing light bulb, Apr 26 2021 BasemenVGarage/Carport Lighting cover/wires/connections creating a exposed electrical L3 X LT 7.5 12.20PM(U1 hazard contact. ) Outlet not GFCI OUTLET: Outlet/switch is protected near water Apr 26 2021 BasemenVGarage/Carport Outlets/Switches L3 1.69 12-17PMU1 missing/damaged source, in laundry room I and near sump pumps. Powered By lnspectCheck Mobile - Page 1/6 Inspection Results: 1551 Pennsylvania - 04/27/2021 (1 Common Area continued) Violations: 2 Possible Pts.: 15 1 Common Area Totals Pts. Lost: 9.188 (9.188 Raw/9.188 Adj./9.188 Cap) Pts. Retained: 5.813 Unit 1 Unit 1-101 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: missing stopper in the Bathroom 1 Shower/Tub - Hardware Missing/damaged/inoperable L1 0.25 Apr 26 2021 bathtub. 2.03PMU1) stopper in bathtub/shower Bedroom 1 Door - Interior HARDWARE: Interior door bedroom door missing L2 0.15 Apr 26 2021 hardware damaged/ inoperable door knob. 2.06PMU1) Health & Safety Health & Safety INFESTATION - Insects L3 X NLT 0.98 Apr 26 2021 2.04PMU1) Living Room Windows SCREENS: Window screen 1 screen with holes, 3 L1 o Apr 26 2021 damaged/missing total screens. 2.02Mu1) Violations: 4 Possible Pts.: 2.917 1 Unit 1-101 Totals Pts. Lost: 1.378 (1.378 Raw/1.378 Adj./1.378 Cap) Pts. Retained: 1.539 Unit 1 Unit 1-102 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Shower/bathtub Bathroom 1 Shower/Tub - Hardware cannot be used due to failed tub diverte, non op. L3 0.98 Apr 26 2021 2:43PMU1) hardware Health & Safety Health & Safety INFESTATION - Insects Bugs in the kitchen. L3 X NLT 0.98 Apr 26 2021 2.28PMU1) Kitchen Outlets/Switches OUTLET: Outlet/switch is GFCI non op in kitchen. L3 0.26 Apr 26 2021 missing/damaged 2:34PMU1) Violations: 3 Possible Pts.: 2.917 1 Unit 1-102 Totals Pts. Lost: 2.231 (2.231 Raw/2.231 Adj./2.231 Cap) Pts. Retained: 0.685 Unit 1 Unit 1-103 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Bathroom 1 Shower/Tub - Hardware Missing/damaged/inoperable L 1 0.25 Apr 26 2021 243PMU1) stopper in bathtub/shower Kitchen Outlets/Switches OUTLET: Outlet/switch is Testing hot/neutral L3 0.26 Apr 26 2021 missing/damaged reverse. 2:46PM(U1) Violations: 2 Possible Pts.: 2.917 1 Unit 1-103 Totals Pts. Lost: 0.509 (0.509 Raw/0.509 Adj./0.509 Cap) Pts. Retained: 2.408 Unit 1 Unit 1-104 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Shower/Tub - Hardware HARDWARE: Missing/damaged/inoperable stopper in bathtub/shower L 1 0.25 Apr 26 2021 2.49PM(u1) Nan McKay Powered By InspectCheck Mobile - Page 2/6 Inspection Results: 1551 Pennsylvania - 04/27/2021 (1 Unit 1-104 continued) Living Room Windows HARDWARE: Window does not stay up - other windows in room function L1 0.07 Apr 26 2021 2.48PMU1) Violations: 2 Possible Pts.: 2.917 1 Unit 1-104 Totals Pts. Lost: 0.32 (0.32 Raw/0.32 Adj./0.32 Cap) Pts. Retained: 2.597 Unit 1 Unit 1-105 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed COVERS: Outlet/switch has Living Room Outlets/Switches broken/missing cover plate - L3 X LT 2.19 Apr 26 2021 251PMU1) exposing wires Violations: 1 Possible Pts.: 2.917 1 Unit 1-105 Totals Pts. Lost: 2.188 (2.188 Raw/2.188 Adj./2.188 Cap) Pts. Retained: 0.729 Unit 1 Unit 1-106 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Kitchen Smoke Detector FIRE SAFETY: Smoke detector inoperable/missing L3 X LT o Apr 26 2021 2.53PMU1) Violations: 1 Possible Pts.: 2.917 1 Unit 1-106 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.917 Unit 1 Unit 1-107 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Shower/bathtub Bathroom 1 Shower/Tub - Hardware cannot be used due to failed tub diverter non op. L3 0.98 Apr 26 2021 2.55PMU1) hardware COVERS: Outlet/switch has Kitchen Outlets/Switches broken/loose cover plate - no GFCI non op. L1 0.07 Apr 26 2021 2:55PMU1) exposed wires Violations: 2 Possible Pts.: 2.917 1 Unit 1-107 Totals Pts. Lost: 1.05 (1.05 Raw/1.05 Adj./1.05 Cap) Pts. Retained: 1.867 Unit 1 Unit 1-108 Location Item Deficiency Notes Bathroom 1 Bathroom 1 HARDWARE: Shower/Tub - Hardware Missing/damaged/inoperable stopper in bathtub/shower HARDWARE: Shower/bathtub Shower/Tub - Hardware cannot be used due to failed hardware Health & Safety Health & Safety INFESTATION - Insects tub diverter non op. bugs in the kitchen. Pic Sev HS LT Pts Date Fixed L1 0.25 Apr 26 2021 2.57PMU1) L3 0.98 Apr 26 2021 2.57PMU1) L3 X NLT 0.98 Apr 26 2021 2.56PMU1) Violations: 3 Possible Pts.: 2.917 1 Unit 1-108 Totals Pts. Lost: 2.215 (2.215 Raw/2.215 Adj./2.215 Cap) Pts. Retained: 0.702 n1 Nan McKay Powered By InspectCheck Mobile- Page 3/6 Inspection Results: 1551 Pennsylvania - 04/27/2021 Unit 1 Unit 1-109 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Kitchen Outlets/Switches OUTLET: Outlet/switch is missing/damaged GFCI non op. L3 0.26 Apr 26 2021 3.00PMU1) Violations: 1 Possible Pts.: 2.917 Unit 1-109 Totals Pts. Lost: 0.263 (0.263 Raw/0.263 Adj./0.263 Cap) Pts. Retained: 2.654 Unit 1 Unit 1-110 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 GFCI GFCI: Outlet does not test or is L3 X NLT 1.46 Apr 26 2021 not operating 3.01PMU1) HARDWARE: Bathroom 1 Shower/Tub - Hardware Missing/damaged/inoperable L1 0.25 Apr 26 2021 3.00PMU1) stopper in bathtub/shower Bathroom 1 Sink HARDWARE: Sink has missing or L1 0.33 Apr 26 2021 damaged stopper or assembly 3.00PMU1) Violations: 3 Possible Pts.: 2.917 1 Unit1-110Totals Pts. Lost: 2.033 (2.033 Raw/2.033 Adj./2.033 Cap) Pts. Retained: 0.884 Unit 1 Unit 1-201 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 GFCI GFCI: Outlet does not test or is L3 X NLT 1.46 Apr 26 2021 not operating 3:18PMU1) HARDWARE: Bathroom 1 Shower/Tub - Hardware Missing/damaged/inoperable L1 0.25 Apr 26 2021 3:18PMU1) stopper in bathtub/shower HARDWARE: Shower/bathtub Bathroom 1 Shower/Tub - Hardware cannot be used due to failed tub diverter non op. L3 0.98 Apr 26 2021 3:18PMU1) hardware Bathroom 1 Sink HARDWARE: Sink has missing or L1 0.33 Apr 26 2021 damaged stopper or assembly 3:17PMU1) Bedroom 1 Smoke Detector FIRE SAFETY: Smoke detector L3 X LT o Apr 26 2021 inoperable/missing 3/18PM(u1 Health & Safety Health & Safety INFESTATION - Insects L3 X NLT 0.98 Apr 26 2021 3:16PMU1) Kitchen Smoke Detector FIRE SAFETY: Smoke detector L3 X LT o Ar 26 2021 inoperable/missing 3:19PMU1) Kitchen Stove/Range BURNERS: Two or more burners L3 0.98 Apr 26 2021 do not function 316PMU1) Living Room Windows SCREENS: Window screen 2 screens have holes, 4 L1 o Apr 26 2021 damaged/missing total screens. 315PMU1) Unit 1-201 Totals Violations: 9 Possible Pts.: 2.917 Pts. Lost: 2.917 (4.986 Raw/4.986 Adj./2.917 Cap) Pts. Retained: O na Nan McKay Powered By InspectCheck Mobile - Page 4/6 Inspection Results: 1551 Pennsylvania - 04/27/2021 Unit 1 Unit 1-202 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit Ap r 27 2021 10:344M(U1 I Violations: O Possible Pts.: 2.917 Unit 1-202 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.917 Unit 1 Unit 1-203 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit Occupancy Vacant unit - not rent ready Ap r 26 2021 3:12PMU1) Violations: O Possible Pts.: 2.917 1 Unit 1-203 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.917 Unit 1 Unit 1-204 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Sink HARDWARE: Sink has missing or damaged stopper or assembly L1 0.33 Apr 26 2021 3:13PMU1) Violations: 1 Possible Pts.: 2.917 1 Unit 1-204 Totals Pts. Lost: 0.328 (0.328 Raw/0.328 Adj./0.328 Cap) Pts. Retained: 2.589 Unit 1 Unit 1-205 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Bathroom 1 Sh ower/Tub - Hardware Missing/damaged/inoperable L1 0.25 Ap r 26 2021 3.09PMU1) stopper in bathtub/shower Kitchen Outlets/Switches OUTLET: Outlet/switch is cracked GFCI cover. L3 0.26 Apr 26 2021 missing/damaged 3:11PM(U1) Violations: 2 Possible Pts.: 2.917 Unit 1-205 Totals Pts. Lost: 0.509 (0.509 Raw/0.509 Adj./0.509 Cap) Pts. Retained: 2.408 Unit 1 Unit 1-206 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Kitchen Range HoodN ent Fan EXHAUST: Missing filter on vent hood or range exhaust L3 0.55 Ap r 26 2021 3.09PMU1) Violations: 1 Possible Pts.: 2.917 1 Unit 1-206 Totals Pts. Lost: 0.547 (0.547 Raw/0.547 Adj./0.547 Cap) Pts. Retained: 2.37 Unit 1 Unit 1-207 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Sink HARDW ARE: Sink has missing or damaged stopper or assembly L1 0.33 Apr 26 2021 3.08PMU1) Nan McKay Powered By lnspectCheck Mobile- Page 5/6 Inspection Results: 1551 Pennsylvania - 04/27/2021 (1 Unit 1-207 continued) Violations: 1 Possible Pts.: 2.917 1 Unit 1-207 Totals Pts. Lost: 0.328 (0.328 Raw/0.328 Adj./0.328 Cap) Pts. Retained: 2.589 Unit 1 Unit 1-208 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Shower/Tub - Hardware HARDWARE: Missing/damaged/inoperable stopper in bathtub/shower L1 0.25 Apr 26 2021 3.08PM01) Violations: 1 Possible Pts.: 2.917 1 Unit 1-208 Totals Pts. Lost: 0.246 (0.246 Raw/0.246 Adj./0.246 Cap) Pts. Retained: 2.671 Unit 1 Unit 1-209 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Shower/Tub - Hardware HARDWARE: Missing/damaged/inoperable stopper in bathtub/shower L1 0.25 Apr 26 2021 3.07PMU1) Violations: 1 Possible Pts.: 2.917 1 Unit 1-209 Totals Pts. Lost: 0.246 (0.246 Raw/0.246 Adj./0.246 Cap) Pts. Retained: 2.671 Unit 1 Unit 1-210 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bedroom 1 Smoke Detector FIRE SAFETY: Smoke detector L3 X LT o Apr 26 2021 inoperable/missing 3.06PM(U1) Health & Safety Health & Safety INFESTATION - Insects bugs in the kitchen. L3 X NLT 0.98 Apr 26 2021 3:.05PM(u1) Kitchen Outlets/Switches OUTLET: Outlet/switch is needs 2 GFCI protected L3 0.26 Apr 26 2021 missing/damaged outlets. 3.06PMU1) Kitchen Smoke Detector FIRE SAFETY: Smoke detector L3 X LT o Apr 26 2021 inoperable/missing 3.06PM01) Local Systems Electric Panel BLOCKED: Blocked access to L3 X NLT 0.66 Apr 26 2021 electric panel or fuse panel 3.04PMU1) Violations: 5 Possible Pts.: 2.917 1 Unit 1-210 Totals Pts. Lost: 1.903 (1.903 Raw/1.903 Adj./1.903 Cap) Pts. Retained: 1.014 nna Nan McKay Powered By InspectCheck Mobile - Page 6/6 na Nan M cK ay The Allen Date 05/07/2021 Type Pre-REAC Area *Pts.Lost(Raw) *Pts. Lost(Adj.) Pts. Lost(Cap) Poss. Points Site o o o 15 Exterior 13.97 13.97 13.97 15 Systems o o o 20 Common 27.66 24.28 15 15 *Units 21.4 5 21.4 5 21.13 35 Total 63.08 59.7 37.64 100 Score 62 Score Violations 15 o 1.03 3 20 o o 11 26.33 70 62.36 84 ·Ps. Lost (Raw) is the total point loss of all findings before the application of HUD scoring rules" Pg. Lost (Adj.) is the raw point loss adjusted for multiple findings of the same violation in the same building/unit per HUD rules" ·ps. Lost (Cap) is the adjusted point loss capped by the maximum possible point loss of each building/unit per HUD rules" Units Area Score is projected for the REAC sample size based on the average unit score" Exterior 1 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Foundation Foundation General Comment Left side foundation vent 1 M ay 4 2021 6 50AM (u1) Foundation Foundation General Comment Foundation vent left side 2 M ay 4 2021 332PM(u1) Foundation Foundation SHARP EDGES: Any defect that 3 L3 X NLT 6.21 M ay 4 2021 could pose a cutting risk 6.44 AM 0 1) Health & Safety Health & Safety SHARP EDGES: Any defect that Cutting hazard, 4 L3 X NLT 6.21 M ay 4 2021 could pose a cutting risk uncommon wireing 6.55AM(u1) GUTTERS: Downspout All downspouts missing Roofing Downspout/Gutter splashblocks are L1 1.55 M ay 4 2021 splashblocks 331PM U 1) missing/damaged 1 Exterior Totals Violations: 3 Possible Pts.: 15 Pts. Lost: 13.973 (13.973 Raw/13.973 Adj./13.973 Cap) Pts. Retained: 1.028 Common Area 1 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Closet/Utility/Mechanical Door - Interior General Comment No key to. Closet 5 M ay 4 2021 7.07A4M (u1) LIGHTING: 20-50% of permanent Lighting non op in M ay 4 2021 Closet/Utility/Mechanical Lighting fixtures storage room 6 L2 2.25 7-12AM U 1) missing/damaged/inoperable COVERS: Outlet/switch has GFCI non op on roof top M ay 4 2021 Closet/Utility/Mechanical Outlets/Switches broken/loose cover plate - no 7 L1 1.13 10.464M (U 1 exposed wires I COVERS: Outlet/switch has Missing outlet cover on M ay 4 2021 Closet/Utility/Mechanical Outlets/Switches broken/loose cover plate - no 8 L1 1.13 10.47AM(U 1 exposed wires roof top ) COVERS: Outlet/switch has Switch missing cover on M ay 4 2021 Closet/Utility/Mechanical Outlets/Switches broken/loose cover plate - no 9 L1 1.13 10.50A4M U 1 exposed wires roof top ) COVERS: Outlet/switch has GFCI non op on roof top M ay 4 2021 Closet/Utility/Mechanical Outlets/Switches broken/loose cover plate - no 10 L1 1.13 10:52A4M /U 1 exposed wires ) Powered By lnspectCheck Mobile- Page 1114 In sp e ct i on R e s ul ts: Th e Al len - 0 5 /0 7 /2 0 2 1 (1 Common Area continued) EXPOSED WIRES: Unsecured May 4 2021 Closet/Utility/Mechanical Outlets/Switches cover/wires/connections creating a roof top 11 L3 X LT 7.5 10 50AMU1 hazard ) HARDWARE: Interior door Second floor next to 212 May 4 2021 Halls/Corridors/Stairs Door - Interior hardware damaged/ inoperable latch non op L2 1.69 10.37A4M/U1 ) Halls/Corridors/Stairs Electric Panel EXPOSED WIRES: Gap of 1/4in. Second floor 12 L3 X LT 7.5 May 4 2021 or more in a breaker row/panel 8214MU1) CRACK: Crack> 1/8in. wide and Bottom of rear stair May 42021 Halls/Corridors/Stairs Walls 13 L1 0.84 10.434M(u1 11in. long case ) TRIPPING: Any obstruction or May 4 2021 Health & Safety Health & Safety defect in a surface that causes Left side ofbuilding 14 L3 X NLT o 6.53Mu1) tripping Kitchen Sink SHARP EDGES: Any defect that Laundry room sink 15 L3 X NLT 3.38 May 4 2021 could pose a cutting risk 7.03A4M(U1) 1 Common Area Totals Violations: 11 Possible Pts.: 15 Pts. Lost: 15 (27.656 Raw/24.281 Adj./15 Cap) Pts. Retained: O Unit 1 Unit 1-101 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Living Room Outlets/Switches OUTLET: Outlet/switch is missing/damaged Improper wiring configuration back wall 16 L3 Violations: 1 Possible Pts.: 2.188 Unit 1-101 Totals Pts. Lost: 0.197 (0.197 Raw/0.197 Adj./0.197 Cap) Pts. Retained: 1.991 Unit 1 Unit 1-102 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Bathroom 1 Shower/Tub - Hardware Missing/damaged/inoperable L1 0.18 May 4 2021 7 25AM01) stopper in bathtub/shower HARDWARE: Self closing device May 4 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or 17 L3 0.22 7 23AM(U1) missing Violations: 2 Possible Pts.: 2.188 1 Unit 1-102 Totals Pts. Lost: 0.406 (0.406 Raw/0.406 Adj./0.406 Cap) Pts. Retained: 1.781 Unit 1 Unit 1-103 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entry Door Door - Entry/Fire/Bath HARDWARE: Self closing device on door not latching to close or missing L3 0.22 May 4 2021 728AM01) Violations: 1 Possible Pts.: 2.188 1 Unit 1-103 Totals Pts. Lost: 0.221 (0.221 Raw/0.221 Adj./0.221 Cap) Pts. Retained: 1.966 na Powered By lnspectCheck Mobile - Page 2/14 Inspection Results: The Allen - 05/07/2021 Unit 1 Unit 1-104 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed EXPOSED WIRES: Unsecured Bathroom 1 Lighting cover/wires/connections creating a Missing cover 18 L3 X LT 1.64 M ay 4 2021 7-41A M (01) hazard Bathroom 1 Ventilation/Exhaust EXHAUST: Exhaust fan not L2 0.49 M ay 4 2021 functioning 7.46.AM (U1) Kitchen Stove/Range BURNERS: One inoperable stove L2 0.37 M ay 42021 burner 7.39AM(U 1) TRIPPING: Any obstruction or M ay 4 2021 Living Room Floor- Hard defect in a surface that causes 19 L3 X NLT o 7/4 0AM(U 1) tripping Living Room Smoke Detector FIRE SAFETY: Smoke detector L3 X LT o M ay 4 2021 inoperable/missing 7 36A4M U 1) 1 Unit 1-104 Totals Violations: 5 Possible Pts.: 2.188 Pts. Lost: 2.188 (2.502 Raw/2.502 Adj./2.188 Cap) Pts. Retained: O Unit 1 Unit 1-105 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Living Room Windows SCREENS: Window screen damaged/missing L1 o M ay 4 2021 7 45AM(01) Violations: 1 Possible Pts.: 2.188 Unit 1-105 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.188 Unit 1 Unit 1-106 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed TRIPPING: Any obstruction or M ay 4 2021 Living Room Floor- Hard defect in a surface that causes 20 L3 X NLT o 7.4 8AM(U 1) tripping Living Room Smoke Detector General Comment Smoke detector is 21 M ay 4 2021 covered 7.50AM (01) Violations: 1 Possible Pts.: 2.188 1 Unit 1-106 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.188 Unit 1 Unit 1-107 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Sink HARDWARE: Sink has missing or damaged stopper or assembly L1 0.25 M ay 4 2021 7.57AM (01) Violations: 1 Possible Pts.: 2.188 1 Unit 1-107 Totals Pts. Lost: 0.246 (0.246 Raw/0.246 Adj./0.246 Cap) Pts. Retained: 1.941 Unit 1 Unit 1-108 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Sink HARDWARE: Sink has missing or damaged stopper or assembly L 1 0.25 M ay 4 2021 8 00AM (U1) na Nan McKay Powered By lnspectCheck Mobile- Page 3/14 In s p e c ti o n R e s u lt s : T h e Al l en - 0 5 /0 7 /2 0 2 1 (1 Unit 1-108 continued) Entry Door Door - Entry/Fire/Bath HARDWARE: Self closing device on door not latching to close or missing L3 0.22 May 42021 7 59AM(U1) Violations: 2 Possible Pts.: 2.188 1 Unit 1-108 Totals Pts. Lost: 0.468 (0.468 Raw/0.468 Adj./0.468 Cap) Pts. Retained: 1.72 Unit 1 Unit 1-109 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Ventilation/Exhaust EXHAUST: Exhaust fan not L2 0.49 May 4 2021 functioning 807AM(U1) HARDWARE: Self closing device Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.22 May 4 2021 8.03AM(U1) missing TRIPPING: Any obstruction or May 4 2021 Living Room Floor- Hard defect in a surface that causes 22 L3 X NLT o 8 05AM(u1) tripping Violations: 3 Possible Pts.: 2.188 1 Unit 1-109 Totals Pts. Lost: 0.714 (0.714 Raw/0.714 Adj./0.714 Cap) Pts. Retained: 1.474 Unit 1 Unit 1-110 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Self closing device May 4 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or 23 L3 0.22 811AM(U1) missing TRIPPING: Any obstruction or Tripping hazard entry Living Room Floor- Hard defect in a surface that causes 24 L3 X NLT o May 4 2021 door 8/10AM(U1) tripping Violations: 2 Possible Pts.: 2.188 1 Unit 1-110 Totals Pts. Lost: 0.221 (0.221 Raw/0.221 Adj./0.221 Cap) Pts. Retained: 1.966 Unit 1 Unit 1-111 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Bathroom 1 Shower/Tub - Hardware Missing/damaged/inoperable L1 0.18 May 42021 8.17AM(u1) stopper in bathtub/shower Bathroom 1 Sink HARDWARE: Sink has missing or L1 0.25 May 4 2021 damaged stopper or assembly 8 18A4M(U1) Violations: 2 Possible Pts.: 2.188 1 Unit 1-111 Totals Pts. Lost: 0.431 (0.431 Raw/0.431 Adj./0.431 Cap) Pts. Retained: 1.757 Unit 1 Unit 1-201 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 GFCI GFCE Outlet does not test or is L3 X NLT 1.09 May 42021 noi operating 8.25AM(U1) Bathroom 1 Sink HARDWARE: Sink has missing or stopper hardware is L1 0.25 May 42021 damaged stopper or assembly loose 826AM(u1) na Powered By InspectCheck Mobile- Page 4/14 Inspection Results: The Alen - 05/07/2021 (1 Unit 1-201 continued) Entry Door Door - Entry/Fire/Bath HARDWARE: Self closing device on door not latching to close or missing Kitchen Stove/Range BURNERS: One inoperable stove burner L3 L2 0.22 0.37 M ay 4 2021 8.23AM (U1) M ay 4 2021 8 25AM (U 1) Violations: 4 Possible Pts.: 2.188 1 Unit 1-201 Totals Pts. Lost: 1.93 (1.93 Raw/1.93 Adj./1.93 Cap) Pts. Retained: 0.257 Unit 1 Unit 1-202 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 GFCI GFCI: Outlet does not test or is cracked G FC I L3 X NLT 1.09 M ay 4 2021 not operating 8 30AM(U 1) HARDWARE: Self closing device Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.22 M ay 4 2021 8 28 M(U 1) missing Violations: 2 Possible Pts.: 2.188 1 Unit 1-202 Totals Pts. Lost: 1.315 (1.315 Raw/1.315 Adj./1.315 Cap) Pts. Retained: 0.872 Unit 1 Unit 1-203 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Self closing device Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.22 M ay 42021 8:34 AM(U 1) missing Kitchen GFCI GFCI: Protected Outlet is missing M ay 4 2021 near sink per local code 8 354M U 1) Kitchen Smoke Detector FIRE SAFETY: Smoke detector Smoke detector quite L3 X LT o M ay 4 2021 inoperable/missing 839AM (U 1) Violations: 2 Possible Pts.: 2.188 1 Unit 1-203 Totals Pts. Lost: 0.221 (0.221 Raw/0.221 Adj./0.221 Cap) Pts. Retained: 1.966 Unit 1 Unit 1-204 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entry Door Door - Entry/Fire/Bath HARDWARE: Self closing device on door not latching to close or missing L3 0.22 M ay 4 2021 8 41AM (0 1) Violations: 1 Possible Pts.: 2.188 1 Unit 1-204 Totals Pts. Lost: 0.221 (0.221 Raw/0.221 Adj./0.221 Cap) Pts. Retained: 1.966 Unit 1 Unit 1-205 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed DRAIN: clogged partially, M ay 4 2021 Bathroom 1 Sink sink/basin does not drain freely L1 0.41 8.48AM(U 1) but still functions HARDWARE: Self closing device Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.22 M ay 4 2021 8 46AM (u1) missing na Nan M'Kay Powered By lnspectCheck Mobile- Page 5/14 In s p e ct i o n R e s ul ts:. Th e Al le n - 0 5/0 7 /2 0 2 1 (1 Unit 1-205 continued) Violations: 2 Possible Pts.: 2.188 1 Unit 1-205 Totals Pts. Lost: 0.632 (0.632 Raw/0.632 Adj./0.632 Cap) Pts. Retained: 1.556 Unit 1 Unit 1-206 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Self closing device M ay 4 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.22 8 52AM 0 1) missing Violations: 1 Possible Pts.: 2.188 1 Unit 1-206 Totals Pts. Lost: 0.221 (0.221 Raw/0.221 Adj./0.221 Cap) Pts. Retained: 1.966 Unit 1 Unit 1-207 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Bathroom 1 Shower/Tub - Hardware Missing/damaged/inoperable L1 0.18 M ay 4 2021 9.02AM (01) stopper in bathtub/shower DRAIN: clogged partially, M ay 4 2021 Bathroom 1 Sink sink/basin does not drain freely L1 0.41 9.01AM (01) but still functions HARDWARE: Self closing device M ay 42021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.22 8 594M (U1) missing Health & Safety Health & Safety INFESTATION - Insects L3 X NLT 0.74 M ay 4 2021 9.01AM (U1) Violations: 4 Possible Pts.: 2.188 1 Unit 1-207 Totals Pts. Lost: 1.554 (1.554 Raw/1.554 Adj./1.554 Cap) Pts. Retained: 0.633 Unit 1 Unit 1-208 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Sink HARDWARE: Sink has missing or L1 0.25 M ay 4 2021 damaged stopper or assembly 9 05A4M (U 1) HARDWARE: Self closing device M ay 4 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.22 9.03AM 0 1) missing HARDWARE: Window will not Living Room Windows open - only window or all windows 26 L3 X NLT 0.22 M ay 4 2021 9 084MU1) in room Violations: 3 Possible Pts.: 2.188 1 Unit 1-208 Totals Pts. Lost: 0.689 (0.689 Raw/0.689 Adj./0.689 Cap) Pts. Retained: 1.498 Unit 1 Unit 1-209 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit Occupancy Could not enter unit (enter reason below) Tenants did not allow entry M ay 4 2021 9.11AM (U 1) Violations: O Possible Pts.: 2.188 Unit 1-209 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.188 na Powered By InspectCheck Mobile- Page 6/14 In s p e ct i o n R e s ul ts: Th e Al le n - 0 5 /0 7 /2 0 2 1 Unit 1 Unit 1-210 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entry Door Door - Entry/Fire/Bath HARDWARE: Self closing device on door not latching to close or missing L3 0.22 May 4 2021 912AM(u1) Violations: 1 Possible Pts.: 2.188 1 Unit 1-210 Totals Pts. Lost: 0.221 (0.221 Raw/0.221 Adj./0.221 Cap) Pts. Retained: 1.966 Unit 1 Unit 1-211 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Sink HARDWARE: Sink has missing or damaged stopper or assembly L1 0.25 May 4 2021 918A4M U1) Violations: 1 Possible Pts.: 2.188 1 Unit 1-211 Totals Pts. Lost: 0.246 (0.246 Raw/0.246 Adj./0.246 Cap) Pts. Retained: 1.941 Unit 1 Unit 1-212 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Shower/Tub - Hardware HARDWARE: Missing/damaged/inoperable stopper in bathtub/shower tub diverter non op L1 0.18 May 4 2021 9234Mu1) Violations: 1 Possible Pts.: 2.188 1 Unit 1-212 Totals Pts. Lost: 0.185 (0.185 Raw/0.185 Adj./0.185 Cap) Pts. Retained: 2.003 Unit 1 Unit 1-213 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Sink HARDWARE: Sink has missing or damaged stopper or assembly L1 0.25 Entry Door Door - Entry/Fire/Bath HARDWARE: Panic Hardware on door inoperable Should be a twist lock on inside of door 27 L3 0.22 May 4 2021 9 28AM(01) May 4 2021 926A4M(U1) Violations: 2 Possible Pts.: 2.188 1 Unit 1-213 Totals Pts. Lost: 0.468 (0.468 Raw/0.468 Adj./0.468 Cap) Pts. Retained: 1.72 Unit 1 Unit 1-214 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Self closing device Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.22 May 4 2021 932AM(01) missing Kitchen GFCI GFCI: Outlet does not test or is L3 X NLT 1.09 May 4 2021 not operating 932AMUu1) Violations: 2 Possible Pts.: 2.188 1 Unit 1-214 Totals Pts. Lost: 1.315 (1.315 Raw/1.315 Adj./1.315 Cap) Pts. Retained: 0.872 na Powered By InspectCheck Mobile- Page 7/14 In s p e ct io n R e s u lt s : T h e AI len - 0 5 /0 7 /2 0 2 1 Unit 1 Unit 1-301 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Sink HARDWARE: Sink has missing or L1 0.25 May 4 2021 damaged stopper or assembly 940AM(u1) HARDWARE: Self closing device May 4 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.22 9.394M(u1) missing Violations: 2 Possible Pts.: 2.188 1 Unit 1-301 Totals Pts. Lost: 0.468 (0.468 Raw/0.468 Adj./0.468 Cap) Pts. Retained: 1.72 Unit 1 Unit 1-302 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entry Door Door - Entry/Fire/Bath HARDWARE: Self closing device on door not latching to close or missing L3 0.22 May 4 2021 9.42AM(u1) Violations: 1 Possible Pts.: 2.188 1 Unit 1-302 Totals Pts. Lost: 0.221 (0.221 Raw/0.221 Adj./0.221 Cap) Pts. Retained: 1.966 Unit 1 Unit 1-303 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Sink HARDWARE: Sink has missing or L1 0.25 May 4 2021 damaged stopper or assembly 9 494M(U1) HARDWARE: Self closing device May 4 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.22 9 454M(U1) mi ssing Violations: 2 Possible Pts.: 2.188 1 Unit 1-303 Totals Pts. Lost: 0.468 (0.468 Raw/0.468 Adj./0.468 Cap) Pts. Retained: 1.72 Unit 1 Unit 1-304 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Self closing device May 4 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.22 951AM(U1) missing Local Systems HVAC System HVAC: HVAC unit does not L3 X NLT 1.64 May 42021 function - heating/cooling 9.54AM(01) Violations: 2 Possible Pts.: 2.188 1 Unit 1-304 Totals Pts. Lost: 1.862 (1.862 Raw/1.862 Adj./1.862 Cap) Pts. Retained: 0.325 Unit 1 Unit 1-305 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entry Door Door - Entry/Fire/Bath HARDWARE: Self closing device on door not latching to close or missing L3 0.22 May 42021 9554M(01) Violations: 1 Possible Pts.: 2.188 1 Unit 1-305 Totals Pts. Lost: 0.221 (0.221 Raw/0.221 Adj./0.221 Cap) Pts. Retained: 1.966 Powered By tnspectCheck Mobile - Page 8/14 Inspection Results: The Allen - 05/07/2021 Unit 1 Unit 1-306 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Self closing device M ay 42021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.22 10.33AM (U 1 missing I Violations: 1 Possible Pts.: 2.188 1 Unit 1-306 Totals Pts. Lost: 0.221 (0.221 Raw/0.221 Adj./0.221 Cap) Pts. Retained: 1.966 Unit 1 Unit 1-307 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Self closing device M ay 4 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.22 10.034M/U 1 missing I EXHAUST: Missing filter on vent M ay 4 2021 Kitchen Range HoodNent Fan L3 0.41 10.04AMU1 hood or range exhaust I TRIPPING: Any obstruction or M ay 4 2021 Living Room Floor- Hard defect in a surface that causes 28 L3 X NLT o 10.04 A4M(U 1 tripping I Violations: 3 Possible Pts.: 2.188 1 Unit 1-307 Totals Pts. Lost: 0.632 (0.632 Raw/0.632 Adj./0.632 Cap) Pts. Retained: 1.556 Unit 1 Unit 1-308 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit M ay 4 2021 10.084M U 1 I Violations: O Possible Pts.: 2.188 1 Unit 1-308 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.188 Unit 1 Unit 1-309 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: M ay 4 2021 Bathroom 1 Shower/Tub - Hardware Missing/damaged/inoperable L1 0.18 10:114M (U1 stopper in bathtub/shower I HARDWARE: Self closing device M ay 4 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.22 10.09A4M (U 1 missing I TRIPPING: Any obstruction or M ay 4 2021 Kitchen Floor- Hard defect in a surface that causes 29 L3 X NLT o 10.09 4M (U 1 tripping I Violations: 3 Possible Pts.: 2.188 1 Unit 1-309 Totals Pts. Lost: 0.406 (0.406 Raw/0.406 Adj./0.406 Cap) Pts. Retained: 1.781 Unit 1 Unit 1-310 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No Issues/Violations No observed deficiencies in entire unit M ay 4 2021 10 204M U 1 I na Powered By InspectCheck Mobile - Page 9/14 Inspection Results: The Allen - 05/07/2021 (1 Unit 1-310 continued) Violations: O Possible Pts.: 2.188 1 Unit 1-310 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.188 Unit 1 Unit 1-311 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Sink has missing or M ay 4 2021 Bathroom 1 Sink L1 0.25 10:23AM U 1 damaged stopper or assembly I HARDWARE: Self closing device M ay 4 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.22 10.21A M/U 1 missing I BURNERS: One inoperable stove M ay 42021 Kitchen Stove/Range burner L2 0.37 10.24A4M(U 1 I GLOBE: Light globe or Lens M ay 4 2021 Living Room Lighting 10:22AM (U 1 missing or damaged I Violations: 3 Possible Pts.: 2.188 1 Unit 1-311 Totals Pts. Lost: 0.837 (0.837 Raw/0.837 Adj./0.837 Cap) Pts. Retained: 1.351 Unit 1 Unit 1-312 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed M ay 4 2021 Bathroom 1 Toilet FIXTURE: Toilet is loose L2 0.82 10.254M U 1 I HARDWARE: Self closing device M ay 4 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.22 10.25A4M (U 1 missing ) TRIPPING: Any obstruction or M ay 4 2021 Kitchen Floor- Hard defect in a surface that causes 31 L3 X NLT o 10.274M U 1 tripping I Violations: 3 Possible Pts.: 2.188 1 Unit 1-312 Totals Pts. Lost: 1.042 (1.042 Raw/1.042 Adj./1.042 Cap) Pts. Retained: 1.146 Unit 1 Unit 1-313 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entry Door Door - Entry/Fire/Bath HARDWARE: Self closing device on door not latching to close or missing L3 M ay 4 2021 0.22 10294Mu1 I Violations: 1 Possible Pts.: 2.188 1 Unit 1-313 Totals Pts. Lost: 0.221 (0.221 Raw/0.221 Adj./0.221 Cap) Pts. Retained: 1.966 Unit 1 Unit 1-314 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entry Door Door - Entry/Fire/Bath HARDWARE: Self closing device on door not latching to close or missing L3 M ay 42021 0.22 10314Mu1 I Violations: 1 Possible Pts.: 2.188 1 Unit 1-314 Totals Pts. Lost: 0.221 (0.221 Raw/0.221 Adj./0.221 Cap) Pts. Retained: 1.966 Powered By lnspectCheck Mobile - Page 10/14 Inspection Results: The Allen - 05/07/2021 Inspection Photos Exterior 1-Foundation Foundation - Left side foundation vent a.±at' • 2 1- Foundation Foundation - Foundation vent left side 3 1.Foundation Foundation - ii8tl I ) I 4 1- Health & Safety Health & Safety - Cutting hazard, uncommon wireing Common Area 5 1- Closet/Utility/Mechanical Door - Interior - No key to. Closet $ 6 1- Closet/Utility/Mechanical Lighting - Lighting non op in storage room 7 1- Closet/Utility/Mechanical Outlets/Switches - GFCI non op on roof top Nan McKay Powered By lnspectCheck Mobile- Page 11/14 Inspection Results: The Allen - 05/07/2021 (Common Area continued) / I 8 1- Closet/Utility/Mechanical Outlets/Switches - Missing outlet cover on roof top 11 1- Closet/Utility/Mechanical Outlets/Switches - roof top 1- Closet/Utility/Mechanical Outlets/Switches - Switch missing cover on roof top 10 1- Closet/Utility/Mechanical Outlets/Switches - GFCI non op on roof top 12 1- Halls/Corridors/Stairs Electric Panel - Second floor 13 1- Halls/Corridors/Stairs Walls - Bottom of rear stair case 14 1- Health & Safety Health & Safety - Left side ofbuilding 15 1- Kitchen Sink - Laundry room sink Unit 16 1 Unit 1-101-Living Room Outlets/Switches - Improper wiring configuration back wall e 17 1 Unit 1-102 - Entry Door Door - Entry/Fire/Bath - 18 Unit 1-104 - Bathroom 1 Lighting - Missing cover na Nan McKay Powered By lnspectCheck Mobile - Page 12/14 Inspection Results: The Allen - 05/07/2021 (Unit continued) ..is ·i +· -. --- ;;. - - - \- - - ..... ~ - - «- #; \ + T é 19 Unit 1-104 -Living Room Floor - Hard - 22 1 Unit 1-109 -Living Room Floor - Hard - 25 Unit 1-203 - Kitchen GFCI- 28 Unit 1-307 -Living Room Floor - Hard - 20 Unit 1-106 - Living Room Floor - Hard - 23 Unit 1-110 - Entry Door Door - Entry/Fire/Bath - 26 Unit 1-208 - Living Room Windows- 29 Unit 1-309 - Kitchen Floor - Hard - Unit 1-106 -Living Room Smoke Detector - Smoke detector is covered 24 Unit 1-110-Living Room Floor - Hard - Tripping hazard entry door 27 Unit 1-213 -Entry Door Door - Entry/Fire/Bath - Should be a twist lock on inside of door 30 Unit 1-311 -Living Room Lighting - Nan McKay Powered By lnspectCheck Mobile- Page 13/14 Inspection Results: The Allen - 05/07/2021 (Unit continued) 31 Unit 1-312 - Kitchen Floor - Hard - na an McKay Powered By lnspectCheck Mobile- Page 14/14 na Nan McKay Westchester Date 04/29/2021 Type Pre-R EA C Area Pts.Lost(Raw) Pts. Lost(Adj.) *Pts. Lost(Cap) Poss. Points Site 6.33 6.33 6.33 15 Exterior 10 10 10 15 Systems o o o 20 Common 5.06 5.06 5.06 15 Units 25.63 25.63 23.02 35 Total 47.02 47.02 33.86 10 0 Score 66 Score Violations 8.67 2 5 1 20 o 9.94 2 22.53 62 66.14 67 ·Pts. Lost (Raw) is the total point loss of all findings before the application of HUD scoring rules' "Pts. Lost (Adj.) is the raw point loss adjusted for multiple findings of the same violation in the same building/unit per HUD rules' ·Pts. Lost (Cap) is the adjusted point loss capped by the maximum possible point loss of each building/unit per HUD rule s Units Area Score is proj ect ed for the REAC sample size based on the average unit score" Entire Site Site Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed VEGETATION: Vegetation contacts unintended surface (not M ay 6 2021 Grounds Vegetation 1 L2 2.11 11/10A4M(U1 including minor contact with fence) ) I no visible damage TRIPPING: Any obstruction or M ay 6 2021 Health & Safety Health & Safety defect in a surface that causes Rear building 2 L3 X NLT 4.22 11.13A4M U1 tripping ) Violations: 2 Possible Pts.: 15 Site Totals Pts. Lost: 6.328 (6.328 Raw/6.328 Adj./6.328 Cap) Pts. Retained: 8.672 Exterior 1 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Electrical Electric Panel EXPOSED WIRES: Open breaker Missing plate for 103 on port or missing fuse roof top 3 L3 X LT 10 M ay 6 2021 312PMU1) Violations: 1 Possible Pts.: 15 1 Exterior Totals Pts. Lost: 10 (1 O Raw/1 O Adj./1 O Cap) Pts. Retained: 5 Common Area 1 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Self closing device Second floor latch is M ay 6 2021 Halls/Corridors/Stairs Door - Entry/Fire/Bath on door not latching to close or missing 4 L3 3.38 12.51PM(U1 missing I Halls/Corridors/Stairs Door - Interior HARDWARE: Interior door Third floor missing latch 5 L2 1.69 M ay 6 2021 hardware damaged/ inoperable 24 0PM (u1) First.second and third Halls/Corridors/Stairs Outlets/Switches General Comment floor above door way, 6 M ay 6 2021 unable to identify if low 330PM (U 1) voltage. Violations: 2 Possible Pts.: 15 1 Common Area Totals Pts. Lost: 5.063 (5.063 Raw/5.063 Adj./5.063 Cap) Pts. Retained: 9.938 Powered By InspectCh eck Mobile- Page 1/12 In s p e c tio n R e s u lts : W e s tch e st e r - 0 4 /2 9 /2 0 2 1 Unit 1 Unit 1-101 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Sink has missing or May 6 2021 Bathroom 1 Sink L1 0.3 11:45AM(U1 damaged stopper or assembly ) GLOBE: Light globe or Lens May 6 2021 CloseUStorage Room lighting In bedroom closet 7 11.474M(U1 missing or damaged ) HARDWARE: Self closing device May 6 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.27 11:404M(U1 missing ) Violations: 2 Possible Pts.: 2.692 1 Unit 1-101 Totals Pts. Lost: 0.575 (0.575 Raw/0.575 Adj./0.575 Cap) Pts. Retained: 2.117 Unit 1 Unit 1-102 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit Occupancy Vacant unit - not rent ready May 6 2021 11:494M(U1 ) Violations: O Possible Pts.: 2.692 1 Unit 1-102 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.692 Unit 1 Unit 1-103 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Self closing device May 6 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.27 11.52AMU1 missing ) CRACK: Crack > 1/8in. wide and May 62021 Living Room Walls 11in. long Near doorway 8 L1 0.06 11.534MU1 ) Violations: 2 Possible Pts.: 2.692 1 Unit 1-103 Totals Pts. Lost: 0.333 (0.333 Raw/0.333 Adj./0.333 Cap) Pts. Retained: 2.359 Unit 1 Unit 1-104 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Closet door May 6 2021 Closet/Storage Room Door - Closet hardware 9 L1 0.07 11.:274M(u1 damaged/missing/inoperable ) HARDWARE: Self closing device May 6 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.27 11.274M(U1 missing ) SURFACE: May 6 2021 Living Room Ceiling Bulging/buckling/sagging or 10 L3 0.32 11,384MU1 problem with alignment ) SCREENS: Window screen May 6 2021 Living Room Windows damaged/missing L1 o 11/30A4M(U1 ) LOCK: Inoperable/not locking- May 6 2021 Living Room Windows lock is broken but window is Right side window L-1 0.07 11/304MU1 secure ) 1 Unit 1-104 Totals Violations: 5 Possible Pts.: 2.692 Pts. Lost: 0.732 (0.732 Raw/0.732 Adj./0.732 Cap) Pts. Retained: 1.96 na Powered By InspectCheck Mobile - Page 2/12 Inspection Results: Westchester - 04/29/2021 Unit 1 Unit 1-105 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: May 6 2021 Bathroom 1 Shower/Tub - Hardware Missing/damaged/inoperable L1 0.23 12:12PM(U1 stopper in bathtub/shower I HARDWARE: Sink has missing or May 6 2021 Bathroom 1 Sink L1 0.3 12:12PM(U1 damaged stopper or assembly ) Bathroom 1 Ventilation/Exhaust SHARP EDGES: Any defect that Missing vent cover 11 L3 X NLT 0.91 May 6 2021 could pose a cutting risk 4.02PM(01) MISSING: A single closet door is May 6 2021 Bedroom 1 Door - Closet missing as shown by 12 L1 0.15 1212PM(U1 hardware/hardware remnants I SCREENS: Window screen May 6 2021 Bedroom 1 Windows damaged/missing L1 o 12.09PM(UI I MISSING: A single closet door is May 6 2021 Closet/Storage Room Door - Closet missing as shown by 13 L1 0.15 12.16PM(U1 hardware/hardware remnants ) HARDWARE: Self closing device May 6 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.27 12.05PM/U1 missing ) May 6 2021 Health & Safety Health & Safety INFESTATION - Insects L3 X NLT 0.91 12.15PM(U1 ) SHARP EDGES: Any defect that May 6 2021 Kitchen Range HoodNent Fan Miissing cover 14 L3 X NLT 0.91 12.06PM(U1 could pose a cutting risk ) HOLE: Hole/missing tile/damaged May 6 2021 Living Room Walls 15 L2 0.12 12.09PM(U1 area more than 8.5x11in. I VALVE: Pressure relief valve Missing pressure release tube, needs to May 62021 Local Systems Water Heater missing or does not extend to be within 6 inches of 16 L3 X NLT 1.35 12:19PM(UI within 18in. of floor ) ground 1 Unit 1-105 Totals Violations: 11 Possible Pts.: 2.692 Pts. Lost: 2.692 (5.299 Raw/5.299 Adj./2.692 Cap) Pts. Retained: O Unit 1 Unit 1-106 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: May 6 2021 Bathroom 1 Shower/Tub - Hardware Missing/damaged/inoperable L1 0.23 1226PMU1 stopper in bathtub/shower ) HARDWARE: Sink has missing or May 6 2021 Bathroom 1 Sink L1 0.3 12:26PMU1 damaged stopper or assembly I WATER STAIN: Evidence of May 6 2021 Bedroom 1 Walls leak/mold/mildew 4 sq in. - 1 sf 17 L1 0.03 12.24PMU1 I HARDWARE: Self closing device May 6 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.27 12.22PMU1 missing ) VALVE: Pressure relief valve Missing pressure May 6 2021 Local Systems Water Heater missing or does not extend to 18 L3 X NLT 1.35 12.33PMU1 within 18in. of floor release tube I 1 Unit 1-106 Totals Violations: 5 Possible Pts.: 2.692 Pts. Lost: 2.182 (2.182 Raw/2.182 Adj./2.182 Cap) Pts. Retained: 0.51 na Powered By InspectCheck Mobile- Page 3/12 Inspection Results: Westchester - 04/29/2021 Unit 1 Unit 1-107 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Shower/bathtub May 6 2021 Bathroom 1 Shower/Tub - Hardware cannot be used due to failed Tub diverter non op L3 0.91 12.45PM(U1 hardware I HARDWARE: Sink has missing or May 6 2021 Bathroom 1 Sink L1 0.3 12:44P M(U1 damaged stopper or assembly ) BURNERS: One inoperable stove May 6 2021 Kitchen Stove/Range L2 0.45 12.48P MU 1 burner I Violations: 3 Possible Pts.: 2.692 1 Unit 1-107 Totals Pts. Lost: 1.666 (1.666 Raw/1.666 Adj./1.666 Cap) Pts. Retained: 1.026 Unit 1 Unit 1-108 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Self closing device May 6 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.27 12-34 PM U1 missing ) May 6 2021 Health & Safety Health & Safety INFESTATION - Insects L3 X NLT 0.91 12.39PM U1 I LIGHT FIXTURES: Inoperable or May 6 2021 Kitchen Lighting Missing Lighting Fixture (One 19 L1 0.04 12.34P M/U1 Room) ) Violations: 3 Possible Pts.: 2.692 1 Unit 1-108 Totals Pts. Lost: 1.222 (1.222 Raw/1.222 Adj./1.222 Cap) Pts. Retained: 1.471 Unit 1 Unit 1-201 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Self closing device May 6 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.27 12.52PM U1 missing I LIGHT FIXTURES: Inoperable or May 6 2021 Kitchen Lighting Missing Lighting Fixture (One Light flickering 20 L1 0.04 12.53PM(U1 Room) I Violations: 2 Possible Pts.: 2.692 1 Unit 1-201 Totals Pts. Lost: 0.313 (0.313 Raw/0.313 Adj./0.313 Cap) Pts. Retained: 2.379 Unit 1 Unit 1-202 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit May 6 2021 1/10PM (U1) Violations: O Possible Pts.: 2.692 1 Unit 1-202 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.692 Unit 1 Unit 1-203 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Sink HARDWARE: Sink has missing or damaged stopper or assembly L1 na Powered By lnspectCheck Mobile- Page 4112 Inspection Results: Westchester - 04/29/2021 (1 Unit 1-203 continued) HARDWARE: Self closing device May 6 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.27 1.12PM(u1) missing Living Room Windows SCREENS: Window screen 21 L1 o May 6 2021 damaged/missing 116PM (U1) VALVE: Pressure relief valve Missing pressure Local Systems Water Heater missing or does not extend to 22 L3 X NLT 1.35 May 6 2021 release tube 1/14PMU1) within 18in. of floor Violations: 4 Possible Pts.: 2.692 1 Unit 1-203 Totals Pts. Lost: 1.922 (1.922 Raw/1.922 Adj./1.922 Cap) Pts. Retained: 0.771 Unit 1 Unit 1-204 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Walls SHARP EDGES: Any defect that 23 L3 X NLT 0.91 May 6 2021 could pose a cutting risk 1.20PM (U1) HARDWARE: Self closing device May 62021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.27 1/18PM (U1) missing Living Room Smoke Detector FIRE SAFETY: Smoke detector L3 X LT o May 62021 inoperable/missing 1 23PM(U1) Violations: 3 Possible Pts.: 2.692 1 Unit 1-204 Totals Pts. Lost: 1.181 (1.181 Raw/1.181 Adj./1.181 Cap) Pts. Retained: 1.511 Unit 4 Unit 1-205 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Sink HARDWARE: Sink has missing or -1 0.3 May 6 2021 damaged stopper or assembly 1:31PM(U1) Kitchen GFCI GFCI: Outlet does not test or is 3 outlets in kitchen all 24 L3 X NLT 1.35 May 6 2021 not operaling missing GFCI 1.29PM(U1) Kitchen Range HoodNent Fan SHARP EDGES: Any defect that could pose a cutting risk Missing vent fan cover 25 L3 X NLT 0.91 May 6 2021 1 28PM(U1) Violations: 3 Possible Pts.: 2.692 1 Unit 1-205 Totals Pts. Lost: 2.558 (2.558 Raw/2.558 Adj./2.558 Cap) Pts. Retained: 0.135 Unit 1 Unit 1-206 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE. Bathroom 1 Shower/Tub - Hardware Missing/damaged/inoperable L1 0.23 May 62021 1/43PM(01) stopper in bathtub/shower Kitchen Stove/Range General Comment Missing stove knobs 26 May 6 2021 1/46PM (U1) Violations: 1 Possible Pts.: 2.692 1 Unit 1-206 Totals Pts. Lost: 0.227 (0.227 Raw/0.227 Adj./0.227 Cap) Pts. Retained: 2.465 na Nan M'cKav Powered By InspectCheck Mobile - Page 5/12 Inspection Results: Westchester - 04/29/2021 Unit 1 Unit 1-207 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Ventilation/Exhaust EXHAUST: Exhaust fan not 27 L2 0.61 May 6 2021 functioning 204PM(u1) Kitchen Stove/Range BURNERS: Two or more burners tenants un plugged L3 0.91 May 6 2021 do not function stove 2 00PM(U1) Violations: 2 Possible Pts.: 2.692 1 Unit 1-207 Totals Pts. Lost: 1.514 (1.514 Raw/1.514 Adj./1.514 Cap) Pts. Retained: 1.178 Unit 1 Unit 1-208 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Sink HARDWARE: Sink has missing or L1 0.3 May 6 2021 damaged stopper or assembly 2.15PMU1) Living Room Lighting GLOBE: Light globe or Lens May 6 2021 missing or damaged 216PM(U1) Violations: 1 Possible Pts.: 2.692 1 Unit 1-208 Totals Pts. Lost: 0.303 (0.303 Raw/0.303 Adj./0.303 Cap) Pts. Retained: 2.389 Unit 1 Unit 1-301 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Health & Safety Health & Safety SHARP EDGES: Any defect that In entry 29 L3 X NLT 0.91 May 6 2021 could pose a cutting risk 2 29PMU1) Kitchen GFCI GFCI: Protected Outlet is missing May 6 2021 near sink per local code 2 28PM(u1) Living Room Ceiling WATER STAIN: Evidence of 31 L1 0.03 May 62021 leak/mold/mildew 4 sq in.- 1 sf 223PM01) COVERS: Outlet/switch has Living Room Outlets/Switches broken/loose cover plate - no Unable to test 32 L1 0.06 May 6 2021 223PM(01) exposed wires Living Room Windows SCREENS: Window screen Screens missing on all L1 o May 6 2021 damaged/missing windows 224PMU1) VAL VE: Pressure relief valve Missing pressure Local Systems Water Heater missing or does not extend to 33 L3 X NLT 1.35 May 62021 release tube 221PM(u1) within 1 Bin. of floor 4 Unit 1-301 Totals Violations: 5 Possible Pts.: 2.692 Pts. Lost: 2.349 (2.349 Raw/2.349 Adj./2.349 Cap) Pts. Retained: 0.343 Unit 1 Unit 1-302 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Sink HARDWARE: Sink has missing or L1 0.3 May 6 2021 damaged stopper or assembly 2 33PM01) VALVE: Pressure relief valve Missing pressure Local Systems Water Heater missing or does not extend to 34 L3 X NLT 1.35 May 6 2021 release tube 2 32PM(01) within 18in. of floor Powered By lnspectCheck Mobile- Page 6/12 In s pe cti o n R e s ul ts: W e st c h e s ter - 0 4 /2 9 /2 0 2 1 (1 Unit 1-302 continued) Violations: 2 Possible Pts.: 2.692 1 Unit 1-302 Totals Pts. Lost: 1.649 (1.649 Raw/1.649 Adj./1.649 Cap) Pts. Retained: 1.043 Unit 1 Unit 1-303 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Shower/bathtub Bathroom 1 Shower/Tub - Hardware cannot be used due to failed Tub diverter non op L3 0.91 May 6 2021 2 42PM (U1) hardware Bathroom 1 Sink HARDWARE: Sink has missing or L1 0.3 May 6 2021 damaged stopper or assembly 241PM(U1) Kitchen GFCI GFCI: Protected Outlet is missing 35 May 6 2021 near sink per local code 244PM(u1) Living Room Smoke Detector FIRE SAFETY: Smoke detector L3 X LT o May 6 2021 inoperable/missing 245PM(u1) Living Room Windows SCREENS: Window screen 36 L1 o May 6 2021 damaged/missing 245PM (u1) 1 Unit 1-303 Totals Violations: 4 Possible Pts.: 2.692 Pts. Lost: 1.212 (1.212 Raw/1.212 Adj./1.212 Cap) Pts. Retained: 1.481 Unit 1 Unit 1-304 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit Occupancy Vacant unit - not rent ready May 6 2021 248PM (u1) Violations: O Possible Pts.: 2.692 Unit 1-304 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.692 Unit 1 Unit 1-305 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit Occupancy No key available Ten ants changed locked May 6 2021 2 49PM(u1) Violations: O Possible Pts.: 2.692 1 Unit 1-305 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.692 Unit 1 Unit 1-306 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed COVERS: Outlet/switch has Kitchen Outlets/Switches broken/loose cover plate - no Small crack on outlet 38 L1 0.06 May 6 2021 2 52PM(01) exposed wires Violations: 1 Possible Pts.: 2.692 1 Unit 1-306 Totals Pts. Lost: 0.061 (0.061 Raw/0.061 Adj./0.061 Cap) Pts. Retained: 2.632 na Powered By InspectCheck Mobile- Page 7/12 In s p e c tio n R e s u lts : W e st ch e st er - 04 /2 9 /2 0 2 1 Unit 1 Unit 1-307 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed PAINT: Peeling/ deteriorated / May 62021 Living Room Walls missing paint/non-workmanlike 39 L2 0.03 258P M(U1) repair affecting > 4sf Living Room Windows SCREENS: Window screen Missing all screens L1 o May 6 2021 damaged/missing 2.59P M(U1) Violations: 2 Possible Pts.: 2.692 1 Unit 1-307 Totals Pts. Lost: 0.027 (0.027 Raw/0.027 Adj./0.027 Cap) Pts. Retained: 2.665 Unit 1 Unit 1-308 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Sink HARDWARE: Sink has missing or damaged stopper or assembly L1 Violations: 1 Possible Pts.: 2.692 1 Unit 1-308 Totals Pts. Lost: 0.303 (0.303 Raw/0.303 Adj./0.303 Cap) Pts. Retained: 2.389 na an McKay Powered By lnspectCheck Mobile - Page 8/12 Inspection Results: Westchester - 04/29/2021 In s p ection P hoto s Entire Site Site - Grounds Vegetation - 2 Site - Health & Safety Health & Safety - Rear building Exterior 3 1- Electrical Electric Panel - Missing plate for 103 on roof top Common Area 4 1- Halls/Corridors/Stairs Door - Entry/Fire/Bath - Second floor latch is missing ? i \ i t t 5 1- Halls/Corridors/Stairs Door - Interior - Third floor missing latch 6 1- Halls/Corridors/Stairs Outlets/Switches - First,second and third floor above door way, unable n a a n M'K ay Powered By InspectCheck Mobile- Page 9/12 Inspection Results: Westchester - 04/29/2021 Unit 7 Unit 1-101 - Closet/Storage Room Lighting - In bedroom closet 10 Unit 1-104 -Living Room Ceiling- 13 Unit 1-105 - Closet/Storage Room Door - Closet - 4 ¥ # 16 Unit 1-105 -Local Systems Water Heater - Missing pressure release tube, needs to be within 6 in 8 Unit 1-103 -Living Room Walls - Near doorway 11 1 Unit 1-105 - Bathroom 1 Ventilation/Exhaust - Missing vent cover 14 Unit 1-105 - Kitchen Range Hood/Vent Fan - Miissing cover 17 Unit 1-106 - Bedroom 1 Walls - 9 Unit 1-104 - Closet/Storage Room Door - Closet - 12 Unit 1-105 - Bedroom 1 Door - Closet - 15 Unit 1-105 - Living Room Walls - Unit 1-106 - Local Systems Water Heater - Missing pressure release tube na Powered By InspectCheck Mobile- Page 10/12 Inspection Results: Westchester - 04/29/2021 (Unit continued) 19 Unit 1-108 - Kitchen Lighting- 22 1 Unit 1-203 -Local Systems Water Heater - Missing pressure release tube 25 Unit 1-205 - Kitchen Range HoodNent Fan - Missing veni fan cover 20 Unit 1-201 - Kitchen Lighting - Light flickering 23 Unit 1-204 - Bathroom 1 Walls- 26 Unit 1-206 - Kitchen Stove/Range - Missing stove knobs 21 Unit 1-203 -Living Room Windows - 24 Unit 1-205 - Kitchen GFCI- 3 outlets in kitchen all missing GFCI 27 Unit 1-207 - Bathroom 1 Ventilation/Exhaust - 28 Unit 1-208 - Living Room Lighting- 29 Unit 1-301 - Health & Safety Health & Safety - In entry 30 Unit 1-301 - Kitchen GFCI- an McKay Powered By InspectCheck Mobile- Page 11/12 Inspection Results: Westchester - 04/29/2021 (Unit continued) Unit 1-301 -Living Room Ceiling- 34 Unit 1-302 - Local Systems Water Heater - Missing pressure release tube 37 Unit 1-305 - Entire Unit Occ upancy - Ten ants changed locked 32 Unit 1-301 - Living Room Outlets/Switches - Unable to test Unit 1-303 - Kitchen GFCI- 38 Unit 1-306 - Kitchen Outlets/Switches - Small crack on outlet 33 Unit 1-301 - Local Systems Water Heater - Missing pressure release tube 36 1 Unit 1-303 - Living Room Windows - 39 1 Unit 1-307 - Living Room Walls - Nan McKay Powered By lnspectCheck Mobile - Page 12/12 na Nan McKay i » 530 Michigan Date 04/30/2021 Type Pre-REAC Area Pts.Lost(Raw) *Pts. Lost(Adj.) Pts. Lost(Cap) Poss. Points Site 12.66 8.44 8.44 15 Exterior 10.98 10.98 9.14 15 Systems o o o 20 Common 14.56 11.75 10 15 *Units 10.87 10.87 10.87 35 Total 49.06 42.03 33.21 100 Score 67 Score Violations 6.56 4 5.86 3 20 o 5 8 29.36 33 66.79 48 "Pts. Lost (Raw) is the total point loss of all findings before the application of HUD scoring rules' Pts. Lost (Adj.) is the raw point loss adjusted for multiple findings of the same violation in the same building/unit per HUD rules' ·Pts. Lost (Cap) is the adjusted point loss capped by the maximum possible point loss of each building/unit per HUD rules" "Units Area Score is projected for the REAC sample size based on the average unit score" Entire Site Site Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed VEGETATION: Vegetation Grounds Vegetation contacts unintended surface (not 1 L2 2.11 Apr 28 2021 including minor contact with fence) 7:.364M(U1) I no visible damage Refuse Disposal Refuse Disposal Area ENCLOSURE: Refuse area too 2 L2 2.11 Apr 28 2021 small for storage until disposal 6:53AM(U1) TRIPPING: Any obstruction or Apr 28 2021 Walkway/Steps Walkway/Steps defect in a surface that causes Near front gate. 3 L3 X NLT 4.22 6:48A4MU1) tripping TRIPPING: Any obstruction or Apr 28 2021 Walkway/Steps Walkway/Steps defect in a surface that causes Rear right of building. 4 L3 X NLT 4.22 6.52A4MU1) tripping Site Totals Violations: 4 Possible Pts.: 15 Pts. Lost: 8.438 (12.656 Raw/8.438 Adj./8.438 Cap) Pts. Retained: 6.563 Exterior 1 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Health & Safety Health & Safety SHARP EDGES: Any defect that could pose a cutting risk Front right gate. L3 Violations: 1 Possible Pts.: 10 1 Exterior Totals Pts. Lost: 4.14 (4.14 Raw/4.14 Adj./4.14 Cap) Pts. Retained: 5.86 Exterior 2 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed CRACK: Wall sections/pieces Front of building Apr 28 2021 Exterior Walls Walls broken apart or separated from overhang. 6 L3 2.24 6.50A4Mu1) wall or non-workmanlike repair EXPOSED WIRES: Unsecured Lighting Lighting cover/wires/connections creating a Second floor near 204. 7 L3 X LT 4.6 Apr 28 2021 7.204MU1) hazard Powered By InspectCheck Mobile- Page 1/11 Inspection Results: 530 Michigan - 04/30/2021 (2 Exterior continued) Violations: 2 Possible Pts.: 5 2 Exterior Totals Pts. Lost: 5 (6.835 Raw/6.835 Adj./5 Cap) Pts. Retained: O Common Area Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Closet door Halls/Corridors/Stairs Door - Closet hardware No key. 8 L1 0.56 Apr 28 2021 7.41A4MU1) damaged/missing/inoperable HARDWARE: Closet door Halls/Corridors/Stairs Door - Closet hardware no key floor closet. L1 0.56 Apr 28 2021 8:344MU1) damaged/missing/inoperable HARDWARE: Self closing device Apr 28 2021 Halls/Corridors/Stairs Door - Entry/Fire/Bath on door not latching to close or 9 L3 2.25 7:.444MU1) missing HARDWARE: Self closing device Halls/Corridors/Stairs Door - Entry/Fire/Bath on door not latching to close or Second floor rear door L3 2.25 Apr 28 2021 9:12A4Mu1) missing Halls/Corridors/Stairs Door - Interior HARDWARE: Interior door 10 L2 1.13 Apr 28 2021 hardware damaged/ inoperable 7.394MU1) Halls/Corridors/Stairs Walls CRACK: Crack> 1/8in. wide and Second floor staircase 11 L1 0.56 Apr 28 2021 11in. long 9:194M(U1) HARDWARE: Self closing device Laundry Room Door - Entry/Fire/Bath on door not latching to close or L3 2.25 Apr 28 2021 7:43AM(U1) missing Other Community Spaces HVAC System General Comment HVAC on roof handel 12 Apr 28 2021 not secured. 9.02AM01) EXPOSED WIRES: Unsecured Missingcover on rooftop Other Community Spaces Outlets/Switches cover/wires/connections creating a 13 L3 X LT 5 Apr 28 2021 HVAC junction box. 9.04A4MU1) hazard 1 Common Area Totals Violations: 8 Possible Pts.: 10 Pts. Lost: 10 (14.563 Raw/11.75 Adj./1 O Cap) Pts. Retained: O Unit 1 Unit 1-101 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit Apr 28 2021 8:21A4MU1) Violations: O Possible Pts.: 2.5 1 Unit 1-101 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.5 Unit 1 Unit 1-102 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed COVERS: Outlet/switch has Kitchen Outlets/Switches broken/loose cover plate - no Loose GFCI. 14 L1 0.06 Apr 28 2021 8:264MU1) exposed wires Violations: 1 Possible Pts.: 2.5 1 Unit 1-102 Totals Pts. Lost: 0.056 (0.056 Raw/0.056 Adj./0.056 Cap) Pts. Retained: 2.444 na Nan McKay Powered By InspectCheck Mobile- Page 2/11 Inspe ction Results: 530 Michigan - 04/30/2021 Unit 1 Unit 1-103 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Bathroom 1 Shower/Tub - Hardware Missing/damaged/inoperable L1 0.21 Apr 28 2021 8:134M(U1) stopper in bathtub/shower HARDWARE: Self closing device Apr 28 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.25 8:14A4MU1) missing Violations: 2 Possible Pts.: 2.5 1 Unit 1-103 Totals Pts. Lost: 0.464 (0.464 Raw/0.464 Adj./0.464 Cap) Pts. Retained: 2.036 Unit 1 Unit 1-104 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No Issues/Violations No observed deficiencies in entire unit Apr 28 2021 8:184M(U1) Violations: O Possible Pts.: 2.5 1 Unit 1-104 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.5 Unit 1 Unit 1-105 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Bathroom 1 Shower/Tub - Hardware Missing/damaged/inoperable L1 0.21 Apr 28 2021 8.004MU1) stopper in bathtub/shower Violations: 1 Possible Pts.: 2.5 1 Unit 1-105 Totals Pts. Lost: 0.211 (0.211 Raw/0.211 Adj./0.211 Cap) Pts. Retained: 2.289 Unit 1 Unit 1-106 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 GFCI GFCI: Outlet does not test or is L3 X NLT 1.25 Apr 28 2021 not operating 8.064MU1) Bedroom 1 Smoke Detector FIRE SAFETY: Smoke detector L3 X LT o Apr 28 2021 inoperable/missing 8.074MU1) Health & Safety Health & Safety INFESTATION - Insects L3 X NLT 0.84 Apr 28 2021 8.084MU1) LIGHT FIXTURES: Inoperable or Apr 28 2021 Kitchen Lighting Missing Lighting Fixture (One 15 L1 0.04 8.04AMu1) Room) 1 Unit 1-106 Totals Violations: 4 Possible Pts.: 2.5 Pts. Lost: 2.131 (2.131 Raw/2.131 Adj./2.131 Cap) Pts. Retained: 0.369 Unit 1 Unit 1-107 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Bathroom 1 Shower/Tub - Hardware Missing/damaged/inoperable L1 0.21 Apr 28 2021 7.534MU1) stopper in bathtub/shower Living Room Smoke Detector FIRE SAFETY: Smoke detector 16 L3 X LT o Apr 28 2021 inoperable/missing 7.50AMU1) n1 Nan McKay Powered By InspectCheck Mobile - Page 3/11 In sp e ct ion R e su lt s: 5 3 0 M ich i g an - 0 4 /3 0 /2 0 2 1 (1 Unit 1-107 continued) Living Room Windows SCREENS: Window screen damaged/missing L1 o Apr 28 2021 7.594MU1) Violations: 3 Possible Pts.: 2.5 1 Unit 1-107 Totals Pts. Lost: 0.211 (0.211 Raw/0.211 Adj./0.211 Cap) Pts. Retained: 2.289 Unit 1 Unit 1-108 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Bathroom 1 Shower/Tub - Hardware Missing/damaged/inoperable L1 0.21 Apr 28 2021 7:57AM(U1) stopper in bathtub/shower HARDWARE: Self closing device Apr 28 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.25 7.57A4MU1) missing Living Room Smoke Detector FIRE SAFETY: Smoke detector L3 X LT o Apr28 2021 inoperable/missing 7.55AM 01) Violations: 3 Possible Pts.: 2.5 1 Unit 1-108 Totals Pts. Lost: 0.464 (0.464 Raw/0.464 Adj./0.464 Cap) Pts. Retained: 2.036 Unit 1 Unit 1-109 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Shower/Tub - Hardware HARDWARE: Missing/damaged/inoperable stopper in bathtub/shower L1 0.21 Apr 28 2021 7:474M U1) Violations: 1 Possible Pts.: 2.5 1 Unit 1-109 Totals Pts. Lost: 0.211 (0.211 Raw/0.211 Adj./0.211 Cap) Pts. Retained: 2.289 Unit 1 Unit 1-201 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entry Door Door - Entry/Fire/Bath HARDWARE: Self closing device on door not latching to close or missing L3 0.25 Apr 28 2021 8:35A4M01) Violations: 1 Possible Pts.: 2.5 1 Unit 1-201 Totals Pts. Lost: 0.253 (0.253 Raw/0.253 Adj./0.253 Cap) Pts. Retained: 2.247 Unit 1 Unit 1-202 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit Apr 28 2021 8.42AM (01) Violations: O Possible Pts.: 2.5 1 Unit 1-202 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.5 Unit 1 Unit 1-203 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit pr 28 2021 8.45A4MU1) na Nan McKay Powered By InspectCheck Mobile - Page 4/11 Inspection Results: 530 Michigan - 04/30/2021 (1 Unit 1-203 continued) Violations: O Possible Pts.: 2.5 Unit 1-203 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.5 Unit 1 Unit 1-204 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit Occupancy Could not enter unit (enter reason Resident sleeping inside below) Apr 28 2021 8.47A4M(U1) Violations: O Possible Pts.: 2.5 Unit 1-204 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.5 Unit 1 Unit 1-205 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Closet/Storage Room Walls CRACK: Crack > 1/8in. wide and 11in. long 17 L1 0.06 Apr 28 2021 8:53AM(U1) Violations: 1 Possible Pts.: 2.5 1 Unit 1-205 Totals Pts. Lost: 0.056 (0.056 Raw/0.056 Adj./0.056 Cap) Pts. Retained: 2.444 Unit 1 Unit 1-206 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed LIGHT FIXTURES: Inoperable or Bathroom 1 Lighting Missing Lighting Fixture (One 18 L1 0.04 Apr 28 2021 8.50A4Mu1) Room) HARDWARE: Shower/bathtub Bathroom 1 Shower/Tub - Hardware cannot be used due to failed tub diverter non op. L3 0.84 Apr 28 2021 8:.504M(U1) hardware Violations: 2 Possible Pts.: 2.5 1 Unit 1-206 Totals Pts. Lost: 0.881 (0.881 Raw/0.881 Adj./0.881 Cap) Pts. Retained: 1.619 Unit 1 Unit 1-207 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 GFCI GFCI: Outlet does not test or is L3 X NLT 1.25 Apr 28 2021 not operating 9.094Mu1) COVERS: Outlet/switch has Bathroom 1 Outlets/Switches broken/loose cover plate - no 19 L1 0.06 Apr 28 2021 9.094MU1) exposed wires Health & Safety Health & Safety SHARP EDGES: Any defect that Kitchen floor. 20 L3 X NLT 0.84 Apr 28 2021 could pose a cutting risk 9.08A4MU1) Kitchen Cabinets CABINETS: Minor cabinet 21 Apr 28 2021 damage less than 10 % 9.064MU1) Living Room Smoke Detector FIRE SAFETY: Smoke detector L3 X LT o Apr 28 2021 inoperable/missing 9.06A4Mu1) 1 Unit 1-207 Totals Violations: 4 Possible Pts.: 2.5 Pts. Lost: 2.15 (2.15 Raw/2.15 Adj./2.15 Cap) Pts. Retained: 0.35 na Nan McKay Powered By lnspectCheck Mobile- Page 5/11 Inspection Results: 530 Michigan - 04/30/2021 Unit 1 Unit 1-208 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit Occupancy No key available Apr 28 2021 9:13A4MU1) 1 Unit 1-208 Totals Violations: O Possible Pts.: 2.5 Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.5 Unit 1 Unit 1-209 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Self closing device Apr 28 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.25 9:144M (U 1) missing Halls/Corridors/Stairs Ceiling WATER STAIN: Evidence of 22 L1 0.03 Ap r 28 2021 leak/mold/mildew 4 sq in.- 1 sf 9:184M(u1) Violations: 2 Possible Pts.: 2.5 1 Unit 1-209 Totals Pts. Lost: 0.284 (0.284 Raw/0.284 Adj./0.284 Cap) Pts. Retained:. 2.216 Unit 2 Unit 2-101 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit Apr 28 2021 7.00AM (U1) Violations: O Possible Pts.: 2.5 2 Unit 2-101 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.5 Unit 2 Unit 2-102 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed SEALS: Deteriorated/Missing Entry Door Door - Entry/Fire/Bath Seals/Caulking/Glazing 23 L3 0.14 Apr 28 2021 7.054MU1 Compound (Light Around Door) Kitchen Cabinets CABINETS: Minor cabinet 24 Apr 28 2021 damage less than 1 O % 7.064Mu1) COVERS: Outlet/switch has Living Room Outlets/Switches broken/loose cover plate - no 25 L 1 0.06 Apr 28 2021 7.064MU1) exposed wires Violations: 2 Possible Pts.: 2.5 2 Unit 2-102 Totals Pts. Lost: 0.197 (0.197 Raw/0.197 Adj./0.197 Cap) Pts. Retained: 2.303 Unit 2 Unit 2-103 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Shower/Tub - Hardware HARDWARE: Missing/damaged/inoperable stopper in bathtub/shower L1 0.21 Apr 28 2021 7:104MU1) Violations: 1 Possible Pts.: 2.5 2 Unit 2-103 Totals Pts. Lost: 0.211 (0.211 Raw/0.211 Adj./0.211 Cap) Pts. Retained: 2.289 nna Nan McKay Powered By lnspectCheck Mobile- Page 6/11 Inspection Results: 530 Michigan - 04/30/2021 Unit 2 Unit 2-104 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed EGRESS: Emergency fire exit Ap r 28 2021 Entry Door Door - Entry/Fire/Bath blocked/unusable - blocked 26 L3 X LT 1.88 7:14AM01) egress Violations: 1 Possible Pts.: 2.5 2 Unit 2-104 Totals Pts. Lost: 1.875 (1.875 Raw/1.875 Adj./1.875 Cap) Pts. Retained: 0.625 Unit 2 Unit 2-201 Location Item Bathroom 1 CabinetsNanity Halls/Corridors/Stairs Health & Safety Smoke Detector Health & Safety Deficiency Notes Pic Sev HS LT Pts Date Fixed VANITY: Any portion of the cabinets, vanity top, or 27 L1 0.12 Ap r 28 2021 7.34AMU1) drawers/doors shows deterioration FIRE SAFETY: Smoke detector 28 L3 X LT o Apr 28 2021 inoperable/missing 7.334MU1) INFESTATION - Insects L3 X NLT 0.84 Apr 28 2021 7.32A4MU1) Kitchen Cabinets CABINETS: Minor cabinet damage less than 10 % Apr 28 2021 7.354MU1) Violations: 3 Possible Pts.: 2.5 2 Unit 2-201 Totals Pts. Lost: 0.961 (0.961 Raw/0.961 Adj./0.961 Cap) Pts. Retained: 1.539 Unit 2 Unit 2-202 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entry Door Door - Entry/Fire/Bath HARDWARE: Door hardware or lock damaged/ inoperable rear door lock is loose L3 0.25 Apr 28 2021 7.31AMUt1) Violations: 1 Possible Pts.: 2.5 2 Unit 2-202 Totals Pts. Lost: 0.253 (0.253 Raw/0.253 Adj./0.253 Cap) Pts. Retained: 2.247 Unit 2 Unit 2-203 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit Apr 28 2021 7.264Mu1) Violations: O Possible Pts.: 2.5 2 Unit 2-203 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.5 Unit 2 Unit 2-204 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit Apr 28 2021 7.224MU1) Violations: O Possible Pts.: 2.5 2 Unit 2-204 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.5 na Nan McKay Powered By InspectCheck Mobile- Page 7/11 Inspection Results: 530 Michigan - 04/30/2021 Unit 2 Unit 2-205 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit Apr 28 2021 719A4M U1) Violations: O Possible Pts.: 2.5 2 Unit 2-205 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.5 na Nan McKay Powered By lnspectCheck Mobile - Page 8/11 Inspe ction Results: 530 Michigan - 04/30/2021 In s p ectio n P h oto s Entire Site fl Si te - Gro unds Veget ation - 2 Si te - Refu se Di spo sal Refuse Disposa l Ar ea - 3 Site - W alkw ay/Steps Walkw ay/Steps - Near front gate. 4 Si te - W al kw ay/Step s W alkw ay/Steps - Rear right of building. Exterior 5 1- Health & Safety Health & Safety - Front right gate. 6 2- Exterior W alls W alls - Front of building overhang. 7 2-Li gh ting Ligh ting - Secon d floor near 204. na Nan McKay Powered By InspectC heck Mobile- Page 9/11 Inspection Results: 530 Michigan - 04/30/2021 Common Area 8 1- Halls/Corridors/Stairs Door - Closet - No key. 11 1- Halls/Corridors/Stairs Walls - Second floor staircase ~ 1- Halls/Corridors/Stairs Door - Entry/Fire/Bath - 12 1- Other Community Spaces HVAC System - HVAC on roof handel not secured. 10 1- Halls/Corridors/Stairs Door - Interior - 13 1- Other Community Spaces Outlets/Switches - Missingcover on rooftop HVAC junction box. Unit 14 Unit 1-102 - Kitchen Outlets/Switches - Loose GFCI. 15 Unit 1-106 - Kitchen Lighting- 16 Unit 1-107 -Living Room Smoke Detector - 17 Unit 1-205 - Closet/Storage Room Walls - 18 1 Unit 1-206 - Bathroom 1 Lighting- 19 Unit 1-207 - Bathroom 1 Outlets/Switches - na Nan McKay Powered By InspectCheck Mobile- Page 10/11 Inspection Results: 530 Michigan - 04/30/2021 (Unit continued) gr ., a g 3 i h se g 20 Unii 1-207 - Health & Safety Health & Safety - Kitchen floor. 23 Unit 2-102 - Entry Door Door - Entry/Fire/Bath - 21 Unit 1-207 - Kitchen Cabinets - 24 2 Unit 2-102 - Kitchen Cabinets - 22 Unit 1-209 - Halls/Corridors/Stairs Ceiling- 25 Unit 2-102 -Living Room Outlets/Switches - 26 2 Unit 2-104- Entry Door Door - Entry/Fire/Bath - 27 2 Unit 2-201 - Bathroom 1 Cabinets/Vanity - 28 Unit 2-201 - Halls/Corridors/Stairs Smoke Detector - na Nan McKay Powered By lnspectCheck Mobile- Page 11/11 n a Non McKay , Meridian Date 05/04/2021 Type Pre-REAC Area *Pts.Lost(Raw) *Pts. Lost(Adj.) Pts. Lost(Cap) Poss. Points Site 2.11 2.11 2.11 15 Exterior 14.66 14.66 14.66 15 Systems o o o 20 Common 18.56 11.39 11.39 15 Units 8.77 7.98 7.98 35 Total 44.1 36.14 31.68 100 Score 68 Score Violations 12.89 1 0.34 3 20 o 3.61 8 31.48 28 68.32 40 ·Pg . Lost (Raw) is the total point loss of all findings before the application of HUD scoring rules" ·Pts. Lost (Adj.) is the raw point loss adjusted for multiple findings of the same violation in the same building/unit per HUD rules' ·Pts. Lost (Cap) is the adjusted point loss capped by the maximum possible point loss of each building/unit per HUD rules' Units Area Score is projected for the REAC sample size based on the average unit score" Entire Site Site Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Grounds Vegetation VEGETATION: Vegetation contacts unintended surface (not including minor contact with fence) / no visible damage 1 L2 2.11 M ay 6 2 0 2 1 6:31AM(U1) Violations: 1 Possible Pts.: 15 Site Totals Pts. Lost: 2.109 (2.109 Raw/2.109 Adj./2.109 Cap) Pts. Retained: 12.891 Exterior 731 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entry Door Door - Entry/Fire/Bath HARDWARE: Door hardware is Right side of building 2 L3 X NLT 6.21 M ay 6 20 2 1 damaged I inoperable / missing 6.2 2AM 0 1) CRACK: Cracks/gaps> 1/Bin.w x Foundation vent have Foundation Foundation gap, cats were seen 3 L2 6.9 M ay 6 20 2 1 1/8in.dx 6in.l 6.29 AM (u 1) under building GUTTERS: Downspout Roofing Downspout/Gutter splashblocks are Left side of building 4 L-1 1.55 M a y 6 20 2 1 6 35AM 0 1) missing/damaged Violations: 3 Possible Pts.: 15 731 Exterior Totals Pts. Lost: 14.663 (14.663 Raw/14.663 Adj./14.663 Cap) Pts. Retained: 0.338 Common Area 731 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Basement/Garage/Carport Door - Closet General Comment No key 5 M ay 6 20 2 1 6 2 3 AM (0 1) HARDWARE: Self closing device M a y 6 20 2 1 Closet/Utility/Mechanical Door - Entry/Fire/Bath on door not latching to close or Third floor 6 L3 3.38 9.04 AM (U 1) missing HARDWARE: Self closing device M ay 6 20 2 1 Closet/Utility/Mechanical Door - Entry/Fire/Bath on door not latching to close or first floor 7 L3 3.38 10.34 AM (U 1 missing I Closet/Utility/Mechanical Lighting GLOBE: Light globe or Lens M ay 6 20 2 1 missing or damaged 6.4 2AM (u 1) Powered By lnspectCheck Mobile - Page 1/11 In sp e ct i on R e s ul t s:. M er i d ia n - 0 5 /0 4 /2 0 2 1 (731 Common Area continued) HARDWARE: Self closing device May 6 2021 Halls/Corridors/Stairs Door - Entry/Fire/Bath on door not latching to close or L3 3.38 6.40AM(Ut) missing HARDWARE: Self closing device Halls/Corridors/Stairs Door - Entry/Fire/Bath on door not latching to close or Second floor 8 L3 3.38 May 6 2021 8 06AM (ut1) missing GLOBE: Light globe or Lens Aux lighting first floor May 6 2021 Halls/Corridors/Stairs Lighting 9 10.30AM(u 1 missing or damaged staircase non op I COVERS: Outlet/switch has GFCI non op front of Halls/Corridors/Stairs Outlets/Switches broken/loose cover plate - no 10 L 1 0.84 May 6 2021 X building 6.20AM(U 1) exposed wires HARDWARE: Self closing device May 6 2021 Laundry Room Door - Entry/Fire/Bath on door not latching to close or Third floor 11 L3 3.38 902AM U1) missing COVERS: Outlet/switch has Roof top outlet non op, May 6 2021 Other Community Spaces Outlets/Switches broken/loose cover plate - no 12 L1 0.4 2 10:164M(U1 exposed wires missing GFCI ) COVERS: Outlet/switch has Roof top outlet non op, May 6 2021 Other Community Spaces Outlets/Switches broken/loose cover plate - no missing GFCI 13 L1 0.4 2 10:20AM(U1 exposed wires ) 731 Common Area Totals Violations: 8 Possible Pts.: 15 Pts. Lost: 11.391 (18.563 Raw/11.391 Adj./11.391 Cap) Pts. Retained: 3.609 Unit 731 Unit 731-101 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entry Door Door - Entry/Fire/Bath HARDWARE: Self closing device on door not latching to close or missing L3 0.24 May 6 2021 6 52AM(01) Violations: 1 Possible Pts.: 2.333 731 Unit 731-101 Totals Pts. Lost: 0.236 (0.236 Raw/0.236 Adj./0.236 Cap) Pts. Retained: 2.097 Unit 731 Unit 731-102 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit May 6 2021 7 04 AM(u1) Violations: O Possible Pts.: 2.333 731 Unit 731-102 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 Unit 731 Unit 731-103 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit May 6 2021 7 08AM(01) Violations: O Possible Pts.: 2.333 731 Unit 731-103 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 n a Powered By InspectCheck Mobile - Page 2/11 Inspection Results. Meridian - 05/04/2021 Unit 731 Unit 731-104 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit May 6 2021 7-13AM(U1) Violations: O Possible Pts.: 2.333 731 Unit 731-104 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 Unit 731 Unit 731-105 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entry Door Door - Entry/Fire/Bath HARDWARE: Self closing device on door not latching to close or missing L3 0.24 May 6 2021 717AM (01) Violations: 1 Possible Pts.: 2.333 731 Unit 731-105 Totals Pts. Lost: 0.236 (0.236 Raw/0.236 Adj./0.236 Cap) Pts. Retained: 2.097 Unit 731 Unit 731-106 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit Occupancy Tenant did not answer Could not enter unit (enter reason when door was knocked, below) was very upset when the door was opened May 6 2021 4.06PM(U1) Violations: O Possible Pts.: 2.333 731 Unit 731-106 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 Unit 731 Unit 731-107 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entry Door Door - Entry/Fire/Bath HARDWARE: Self closing device on door not latching to close or missing L3 0.24 May 6 2021 7 25AM 0 1) Violations: 1 Possible Pts.: 2.333 731 Unit 731-107 Totals Pts. Lost: 0.236 (0.236 Raw/0.236 Adj./0.236 Cap) Pts. Retained: 2.097 Unit 731 Unit 731-108 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit May 6 2021 7.25AM(U1) Violations: O Possible Pts.: 2.333 731 Unit 731-108 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 Unit 731 Unit 731-109 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Toilet FIXTURE: Toilet is loose L2 O.BB May 6 2021 6 48AM(01) n a Nan McKay Pow ered By InspectCheck Mobile- Page 3/11 In sp e ct ion R e s u lts:. M e ri d ian - 0 5 /0 4 /2 0 2 1 (731 Unit 731-109 continued) Entry Door Door - Entry/Fire/Bath HARDWARE: Self closing device on door not latching to close or missing L3 0.24 May 6 2021 6.454MU1) Violations: 2 Possible Pts.: 2.333 731 Unit 731-109 Totals Pts. Lost: 1.111 (1.111 Raw/1.111 Adj./1.111 Cap) Pts. Retained: 1.222 Unit 731 Unit 731-110 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entry Door Door - Entry/Fire/Bath HARDWARE: Self closing device on door not latching to close or missing L3 0.24 May 6 2021 7 28A4M(U1) Violations: 1 Possible Pts.: 2.333 731 Unit 731-110 Totals Pts. Lost: 0.236 (0.236 Raw/0.236 Adj./0.236 Cap) Pts. Retained: 2.097 Unit 731 Unit 731-201 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Living Room Windows SCREENS: Window screen damaged/missing L1 o May 6 2021 7.41AM(U1) Violations: 1 Possible Pts.: 2.333 731 Unit 731-201 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 Unit 731 Unit 731-202 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No Issues/Violations No observed deficiencies in entire unit May 6 2021 7.454M(01) Violations: O Possible Pts.: 2.333 731 Unit 731-202 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 Unit 731 Unit 731-203 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entry Door Door - Entry/Fire/Bath HARDWARE: Self closing device on door not latching to close or missing L3 0.24 May 62021 7.464MU1) Violations: 1 Possible Pts.: 2.333 731 Unit 731-203 Totals Pts. Lost: 0.236 (0.236 Raw/0.236 Adj./0.236 Cap) Pts. Retained: 2.097 Unit 731 Unit 731-204 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit May 6 2021 8 28AM(U1) Violations: O Possible Pts.: 2.333 731 Unit 731-204 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 na Powered By InspectCheck Mobile - Page 4/11 In sp e ction R e su lts:. M er i di a n - 0 5 /0 4 /2 0 2 1 Unit 731 Unit 731-205 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bedroom 1 Windows General Comment Bedroom window will not close May 6 2021 757AM(U1) Living Room Windows HARDWARE: Window will not open - other windows in room function 15 L 1 0.06 May 6 2021 7.594M(u1) Violations: 1 Possible Pts.: 2.333 731 Unit 731-205 Totals Pts. Lost: 0.059 (0.059 Raw/0.059 Adj./0.059 Cap) Pts. Retained: 2.274 Unit 731 Unit 731-206 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Kitchen GFCI GFCI: Outlet does not test or is not operating L3 X NLT 1.17 May 6 2021 8/10AM(01) X Violations: 1 Possible Pts.: 2.333 731 Unit 731-206 Totals Pts. Lost: 1.167 (1.167 Raw/1.167 Adj./1.167 Cap) Pts. Retained: 1.167 Unit 731 Unit 731-207 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesN iolations No observed deficiencies in entire unit May 6 2021 8.23AM(U1) Violations: O Possible Pts.: 2.333 731 Unit 731-207 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 Unit 731 Unit 731-208 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bedroom 1 Windows SCREENS: Window screen L1 o May 6 2021 damaged/missing 841AM(01) HARDWARE: Closet door Closet/Storage Room Door - Closet hardware 16 L1 0.06 May 6 2021 8.42AM(u1) damaged/missing/inoperable Violations: 2 Possible Pts.: 2.333 731 Unit 731-208 Totals Pts. Lost: 0.059 (0.059 Raw/0.059 Adj./0.059 Cap) Pts. Retained: 2.274 Unit 731 Unit 731-209 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Living Room Windows SCREENS: Window screen damaged/missing 17 L1 o May 6 2021 8.32AM(U1) Violations: 1 Possible Pts.: 2.333 731 Unit 731-209 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 n a an M cKay Powered By InspectCheck Mobile- Page 5/11 In sp e ct io n R e s ul ts: M er i d ia n - 0 5 /0 4 /2 0 2 1 Unit 731 Unit 731-210 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Kitchen GFCI GFCI: Outlet does not test or is L3 X NLT 1.17 May 6 2021 not operating 8.35 M(U1) Living Room Windows SCREENS: Window screen L1 o May 6 2021 damaged/missing 836 4M (U1) Violations: 2 Possible Pts.: 2.333 731 Unit 731-210 Totals Pts. Lost: 1.167 (1.167 Raw/1.167 Adj./1.167 Cap) Pts. Retained: 1.167 Unit 731 Unit 731-211 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed COVERS: Outlet/switch has Kitchen Outlets/Switches broken/loose cover plate - no Outlet non op, 18 L1 0.05 May 6 2021 8 46AM (U1) exposed wires HOLE: Hole/missing May 6 2021 Kitchen Walls tile/damaged/non-workmanlike 19 L1 0.05 8.474M (u1) repair 1 in.- 8.5x11 in. Violations: 2 Possible Pts.: 2.333 731 Unit 731-211 Totals Pts. Lost: 0.105 (0.105 Raw/0.105 Adj./0.105 Cap) Pts. Retained: 2.228 Unit 731 Unit 731-212 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit Occupancy Vacant unit - rent ready Inspection was made May 6 2021 8 54AM 01) Living Room Windows SCREENS: Window screen damaged/missing L1 o May 6 2021 8 52AM (u1) Violations: 1 Possible Pts.: 2.333 731 Unit 731-212 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 Unit 731 Unit 731-301 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No Issues/Violations No observed deficiencies in entire unit May 6 2021 9 284M (01) Violations: O Possible Pts.: 2.333 731 Unit 731-301 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 Unit 731 Unit 731-302 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Kitchen Windows SCREENS: Window screen damaged/missing L1 o May 6 2021 9184M (U1) Violations: 1 Possible Pts.: 2.333 731 Unit 731-302 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 na Powered By lnspectCheck Mobile- Page 6/11 In s p e c tio n R e s u lts : M er i di an - 0 5 /0 4 /2 0 2 1 Unit 731 Unit 731-303 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No Issues/Violations No observed deficiencies in entire unit May 6 2021 928AM(u1) Violations: O Possible Pts.: 2.333 731 Unit 731-303 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 Unit 731 Unit 731-304 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Window will not Living Room Windows open - only window or all windows L3 X NLT 0.24 May 6 2021 9.334M(U1) in room Violations: 1 Possible Pts.: 2.333 731 Unit 731-304 Totals Pts. Lost: 0.236 (0.236 Raw/0.236 Adj./0.236 Cap) Pts. Retained: 2.097 Unit 731 Unit 731-305 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Health & Safety Health & Safety SHARP EDGES: Any defect that 20 L3 X NLT 0.79 May 6 2021 could pose a cutting risk 9 384Mu1) Health & Safety Health & Safety SHARP EDGES: Any defect that Bathroom tile 21 L3 X NLT 0.79 May 6 2021 could pose a cutting risk 9.414M(U1) Violations: 2 Possible Pts.: 2.333 731 Unit 731-305 Totals Pts. Lost: 0.788 (1.575 Raw/0.788 Adj./0.788 Cap) Pts. Retained: 1.546 Unit 731 Unit 731-306 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No Issues/Violations No observed deficiencies in entire unit May 6 2021 937AM(U1) Violations: O Possible Pts.: 2.333 731 Unit 731-306 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 Unit 731 Unit 731-307 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No Issues/Violations No observed deficiencies in entire unit May 6 2021 9454M(u1) Violations: O Possible Pts.: 2.333 731 Unit 731-307 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 Unit 731 Unit 731-308 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Window will not Bedroom 1 Windows open - other windows in room 22 L1 0.06 May 6 2021 9.48AM01) function na Nan McKay Powered By InspectCheck Mobile - Page 7/11 Inspection Results: Meridian - 05/04/2021 (731 Unit 731-308 continued) Violations: 1 Possible Pts.: 2.333 731 Unit 731-308 Totals Pts. Lost: 0.059 (0.059 Raw/0.059 Adj./0.059 Cap) Pts. Retained: 2.274 Unit 731 Unit 731-309 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Self closing device May 6 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.24 951AM(01) missing Health & Safety Health & Safety SHARP EDGES: Any defect that Bathroom tile 23 L3 X NLT 0.79 May 6 2021 could pose a cutting risk 954AM(u1) Violations: 2 Possible Pts.: 2.333 731 Unit 731-309 Totals Pts. Lost: 1.024 (1.024 Raw/1.024 Adj./1.024 Cap) Pts. Retained: 1.31 Unit 731 Unit 731-310 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit Housekeeping HOUSEKEEPING: Excessive Clutter or Disorganized Area Unable to complete inspection May 6 2021 9.50AM u1) Violations: O Possible Pts.: 2.333 731 Unit 731-310 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 Unit 731 Unit 731-311 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Kitchen Stove/Range BURNERS: Two or more burners 25 L3 0.79 May 6 2021 X do not function 9 58AM(u1) FIRE SAFETY: Smoke detector May 6 2021 Living Room Smoke Detector inoperable/missing L3 X LT o 10.00AM(U1 X ) Violations: 2 Possible Pts.: 2.333 731 Unit 731-311 Totals Pts. Lost: 0.788 (0.788 Raw/0.788 Adj./0.788 Cap) Pts. Retained: 1.546 Unit 731 Unit 731-312 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entry Door Door - Entry/Fire/Bath HARDWARE: Self closing device on door not latching to close or missing L3 May 6 2021 0.24 10.02A4MU1 ) Violations: 1 Possible Pts.: 2.333 731 Unit 731-312 Totals Pts. Lost: 0.236 (0.236 Raw/0.236 Adj./0.236 Cap) Pts. Retained: 2.097 na Powered By lnspectCheck Mobile- Page 8/11 Inspection Results: Meridian - 05/04/2021 Inspection Photos Entire Site Site - Grounds Vegetation - Exterior 2 731-Entry Door Door - Entry/Fire/Bath - Right side of building 731-Foundation Foundation - Foundation vent have gap, cats were seen under building 4 731- Roofing Downspout/Gutter - Left side of building Common Area 5 731- Basement/Garage/Carport Door - Closet - No key 6 731- Closet/Utility/Mechanical Door - Entry/Fire/Bath - Third floor 7 731- Closet/Utility/Mechanical Door - Entry/Fire/Bath - first floor na Powered By InspectCheck Mobile- Page 9/11 Inspection Results: Meridian - 05/04/2021 (Common Area continued) 8 731- Halls/Corridors/Stairs Door - Entry/Fire/Bath - Second floor I 731-Laundry Room Door - Entry/Fire/Bath - Third floor 9 731 - Halls/Corridors/Stairs Lighting - Aux lighting first floor staircase non op 12 731- Other Community Spaces Outlets/Switches - Roof top outlet non op, missing GFCI 10 731 - Halls/Corridors/Stairs Outlets/Switches - GFCI non op front of building 13 731- Other Community Spaces Outlets/Switches - Roof top outlet non op, missing GFCI Unit 14 731 Unit 731-201 -Living Room Windows- 15 731 Unit 731-205 -Living Room Windows - 16 731 Unit 731.-208 - Closet/Storage Room Door - Closet - 17 731 Unit 731-209 - Living Room Windows - 18 731 Unit 731-211-Kitchen Outlets/Switches - Outlet non op, 19 731 Unit 731-211 - Kitchen Walls- na Nan McKay Powered By InspectCheck Mobile- Page 10/11 In spe c tio n R e s u lt s : M e ri di an - 0 5 /0 4 /2 0 2 1 (Unit continued) 20 731 Unit 731-305- Health & Safety Health & Safety - 23 731 Unit 731-309 - Health & Safety Health & Safety - Bathroom tile 21 731 Unit 731-305 - Health & Safety Health & Safety - Bathroom tile 24 731 Unit 731-310 - Entire Unit Housekeeping - Unable to complete inspection 22 731 Unit 731-308 - Bedroom 1 Windows - 25 731 Unit 731-311 - Kitchen Stove/Range - na Powered By lnspectCheck Mobile - Page 11/11 na Nan McKay « , Villa Maria Date 05/05/2021 Type Pre-REAC Area *Pts.Lost(Raw) Site 2.11 Exterior 7.94 Systems o Common 16.5 Units 8.86 Total 35.4 Pts. Lost(Adj.) *Pts. Lost(Cap) Poss. Points 2.11 2.11 15 7.94 7.94 15 o o 20 16.5 15 15 8.86 8.86 35 35.4 28.95 100 Score 71 Score Violations 12.89 7.07 2 20 o o 5 31.09 26 71.05 34 "Pts. Lost (Raw) is the total point loss of all findings before the application of HUD scoring rules' ·Pts. Lost (Adj.) is the raw point loss adjusted for multiple findings of the same violation in the same building/unit per HUD rules' "Pts. Lost (Cap) is the adjusted point loss capped by the maximum possible point loss of each building/unit per HUD rules Units Area Score is projected for the REAC sample size based on the average unit score" Entire Site Site Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Grounds Vegetation VEGETATION: Vegetation contacts unintended surface (not including minor contact with fence) I no visible damage 1 L2 2.11 May 3 2021 6:32AM(U1) Violations: 1 Possible Pts.: 15 Site Totals Pts. Lost: 2.109 (2.109 Raw/2.109 Adj./2.109 Cap) Pts. Retained: 12.891 Exterior 1 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed FRAME: Damage to M a y 3 202 1 Entry Door Door - Entry/Fire/Bath frame/lintel/threshold non-fire 2 L2 X NLT 1.73 6.364MU1) rated door jamb HARDWARE: Self closing device M a y 3 20 21 Entry Door Door - Entry/Fire/Bath on door not latching to close or 3 L3 X NLT 6.21 6.3 8AM (U 1) missing Violations: 2 Possible Pts.: 15 1 Exterior Totals Pts. Lost: 7.935 (7.935 Raw/7.935 Adj./7.935 Cap) Pts. Retained: 7.065 Common Area 1 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed EXPOSED WIRES: Any Missing cover on roof M a y 3 202 1 Closet/Utility/Mechanical Electric Panel loose/unsecured section of a 4 L3 X LT 3.75 10.04 A M (U 1 panel cover top I COVERS: Outlet/switch has Roof top GFCI non op, M a y 3 202 1 Closet/Utility/Mechanical Outlets/Switches broken/loose cover plate - no 5 L 1 1.13 10.034M (U1 exposed wires missing cover I COVERS: Outlet/switch has Roof top GFCI missing May 3 2021 Closet/Utility/Mechanical Outlets/Switches broken/missing cover plate - plate/cover, GF CI non 6 L3 X LT 3.75 10.074M (U1 exposing wires op I Halls/Corridors/Stairs Door - Entry/Fire/Bath HARDWARE: Door hardware or Door latch/lock non op L3 3.38 May 3 2021 lock damaged/ inoperable second floor near 203 752AM (01) SEALS: Deteriorated/Missing May 3 2021 Halls/Corridors/Stairs Door - Entry/Fire/Bath Seals/Caulking/Glazing 7 L3 4.5 7.49A4M(u1) Compound Powered By lnspectCheck Mobile - Page 1/11 Insp ection Results: Villa Maria - 05/05/2021 (1 Common Area continued) Violations: 5 Possible Pts.: 15 1 Common Area Totals Pts. Lost: 15 (16.5 Raw/16.5 Adj./15 Cap) Pts. Retained: O Unit 1 Unit 1-101 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit May 3 2021 6 45AM(01) Violations: O Possible Pts.: 2.333 1 Unit 1-101 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 Unit 1 Unit 1-102 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit May 3 2021 6.494M(U1) Violations: O Possible Pts.: 2.333 1 Unit 1-102 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 Unit 1 Unit 1-103 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit May 3 2021 6.554M(01) Violations: O Possible Pts.: 2.333 Unit 1-103 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 Unit 1 Unit 1-104 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit May 3 2021 6 59A4M(u1) Violations: O Possible Pts.: 2.333 1 Unit 1-104 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 Unit 1 Unit 1-105 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Self closing device May 3 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.24 10:10AM/U1 missing I GFCI: Protected Outlet is missing May 3 2021 Kitchen GFCI 8 10:13AM(U1 near sink per local code I Violations: 1 Possible Pts.: 2.333 1 Unit 1-105 Totals Pts. Lost: 0.236 (0.236 Raw/0.236 Adj./0.236 Cap) Pts. Retained: 2.097 na Nan McKay Powered By InspectCheck Mobile- Page 2/11 Inspection Results: Villa Maria - 05/05/2021 Unit 1 Unit 1-106 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit May 3 2021 7.06AM (u1) Violations: O Possible Pts.: 2.333 Unit 1-106 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 Unit 1 Unit 1-107 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit May 3 2021 711A4M (01) Violations: O Possible Pts.: 2.333 Unit 1-107 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 Unit 1 Unit 1-108 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit May 3 2021 7 22AM (U1) Violations: O Possible Pts.: 2.333 1 Unit1-108Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 Unit 1 Unit 1-109 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit May 3 2021 7 20AM(U1) Violations: O Possible Pts.: 2.333 1 Unit1-109Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 Unit 1 Unit 1-110 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed COVERS: OutleVswitch has Kitchen Outlets/Switches broken/missing cover plate - 9 L3 X LT 1.75 May 3 2021 7/244AM(U1) exposing wires Violations: 1 Possible Pts.: 2.333 1 Unit 1-110 Totals Pts. Lost: 1.75 (1.75 Raw/1.75 Adj./1.75 Cap) Pts. Retained: 0.583 Unit 1 Unit 1-201 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Kitchen Countertop SHARP EDGES: Any defect that could pose a cutting risk 10 L3 X NLT 0.79 May 3 2021 733AM(U1) na Nan Mt¢Kay Powered By InspectCheck Mobile- Page 3/11 Inspection Results: Villa Maria - 05/05/2021 (1 Unit 1-201 continued) Violations: 1 Possible Pts.: 2.333 1 Unit 1-201 Totals Pts. Lost: 0.788 (0.788 Raw/0.788 Adj./0.788 Cap) Pts. Retained: 1.546 Unit 1 Unit 1-202 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit May 3 2021 7 39AMU1) Violations: O Possible Pts.: 2.333 1 Unit 1-202 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 Unit 1 Unit 1-203 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit Occupancy Vacant unit- not rent ready May 3 2021 753AM(U1) Violations: O Possible Pts.: 2.333 Unit 1-203 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 Unit 1 Unit 1-204 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Shower/Tub - Hardware SHARP EDGES: Any defect that could pose a cutting risk Tenant requests new soap holder 11 L3 X NLT 0.79 May 3 2021 841AM(u1) Violations: 1 Possible Pts.: 2.333 1 Unit 1-204 Totals Pts. Lost: 0.788 (0.788 Raw/0.788 Adj./0.788 Cap) Pts. Retained: 1.546 Unit 1 Unit 1-205 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Health & Safety Health & Safety INFESTATION - Insects Termights 12 L3 X NLT 0.79 May 3 2021 8.46A4MU1) Violations: 1 Possible Pts.: 2.333 1 Unit 1-205 Totals Pts. Lost: 0.788 (0.788 Raw/0.788 Adj./0.788 Cap) Pts. Retained: 1.546 Unit 1 Unit 1-206 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed VANITY: Any portion of the Bathroom 1 CabinetsNanity cabinets. vanity top, or 13 L1 0.11 May 3 2021 8.16AM(U1) drawers/doors shows deterioration HARDWARE: Self closing device May 3 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.24 8 14AM(U1) missing Violations: 2 Possible Pts.: 2.333 1 Unit 1-206 Totals Pts. Lost: 0.346 (0.346 Raw/0.346 Adj./0.346 Cap) Pts. Retained: 1.988 n1 Nan McKay Powered By InspectCheck Mobile - Page 4/11 Inspection Results: Villa Maria - 05/05/2021 Unit 1 Unit 1-207 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed MISSING: A single door is missing May 3 2021 Closet/Storage Room Door - Interior as shown by hardware/hardware 14 L 1 0.13 7.42AM (u1) remnants Violations: 1 Possible Pts.: 2.333 1 Unit 1-207 Totals Pts. Lost: 0.131 (0.131 Raw/0.131 Adj./0.131 Cap) Pts. Retained: 2.202 Unit 1 Unit 1-208 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No Issues/Violations No observed deficiencies in entire unit May 3 2021 7.48A4M(U1) Violations: O Possible Pts.: 2.333 Unit 1-208 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 Unit 1 Unit 1-209 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit May 3 2021 7.56AM U1) Violations: O Possible Pts.: 2.333 1 Unit 1-209 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 Unit 1 Unit 1-210 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entry Door Door - Entry/Fire/Bath HARDWARE: Self closing device on door not latching to close or missing Door not latching L3 0.24 May 3 2021 7 58AM(U1) Violations: 1 Possible Pts.: 2.333 1 Unit 1-210 Totals Pts. Lost: 0.236 (0.236 Raw/0.236 Adj./0.236 Cap) Pts. Retained: 2.097 Unit 1 Unit 1-211 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bedroom 1 Windows SCREENS: Window screen damaged/missing L1 o May 3 2021 8.08AM U1) Violations: 1 Possible Pts.: 2.333 Unit 1-211 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 Unit 1 Unit 1-212 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No Issues/Violations No observed deficiencies in entire unit May 3 2021 8.114M(U1) na Nan McKay Powered By InspectCheck Mobile - Page 5/11 In sp e ct i on R e s ul ts: Villa Maria - 05/05/2021 (1 Unit 1-212 continued) Violations: O Possible Pts.: 2.333 1 Unit 1-212 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 Unit 1 Unit 1-301 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit May 3 2021 8 48AM(U1) Violations: O Possible Pts.: 2.333 1 Unit 1-301 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 Unit 1 Unit 1-302 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entry Door Door - Entry/Fire/Bath HARDWARE: Self closing device on door not latching to close or missing L3 0.24 May 3 2021 856AM(U1) Violations: 1 Possible Pts.: 2.333 1 Unit 1-302 Totals Pts. Lost: 0.236 (0.236 Raw/0.236 Adj./0.236 Cap) Pts. Retained: 2.097 Unit 1 Unit 1-303 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Toilet FIXTURE: Toilet is loose L2 0.88 May 3 2021 9:09AM(U1) HARDWARE: Self closing device May 3 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.24 9.07AM(u1) missing Violations: 2 Possible Pts.: 2.333 1 Unit 1-303 Totals Pts. Lost: 1.111(1.111 Raw/1.111 Adj./1.111 Cap) Pts. Retained: 1.222 Unit 1 Unit 1-304 Location Kitchen Living Room Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Cabinets CABINETS: Minor cabinet 16 May 3 2021 damage less than 1 0% 9.134M(U1) Smoke Detector FIRE SAFETY: Smoke detector Smoke detector is to L3 X LT o May 3 2021 inoperable/missing quite 915A4M(U1) Violations: 1 Possible Pts.: 2.333 1 Unit 1-304 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.333 Unit 1 Unit 1-305 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Closet/Storage Room Door - Closet HARDWARE: Door off track and/or damaged door track 17 L 1 0.06 May 3 2021 9 24AM (U1) Entry Door Door - Entry/Fire/Bath HARDWARE: Entry Door Opening force is more than 5 pounds (UFAS4.13.11) May 3 2021 9:19AM(U1) na Nan McKay Powered By InspectCheck Mobile- Page 6/11 In sp e ct i o n R e s ul ts : Villa Maria - 05/05/2021 (1 Unit 1-305 continued) Kitchen Cabinets CABINETS: Minor cabinet damage less than 1 O % May 3 2021 9.21A4M(U1) Violations: 1 Possible Pts.: 2.333 1 Unit 1-305 Totals Pts. Lost: 0.059 (0.059 Raw/0.059 Adj./0.059 Cap) Pts. Retained: 2.274 Unit 1 Unit 1-306 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Closet/Storage Room Lighting GLOBE: Light globe or Lens 19 May 3 2021 missing or damaged 9 34AM(U1) TRIPPING: Any obstruction or May 3 2021 Entry Door Door - Entry/Fire/Bath defect in a surface that causes 20 L3 X NLT o 9.29AM(u1) tripping Living Room Outlets/Switches OUTLET: Outlet/switch is 21 L3 0.21 May 3 2021 missing/damaged 9.31AMU1) Living Room Smoke Detector FIRE SAFETY: Smoke detector L3 X LT o May 3 2021 inoperable/missing 9.31AM(U1) Violations: 3 Possible Pts.: 2.333 1 Unit 1-306 Totals Pts. Lost: 0.21 (0.21 Raw/0.21 Adj./0.21 Cap) Pts. Retained: 2.123 Unit 1 Unit 1-307 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Kitchen Outlets/Switches OUTLET: Outlet/switch is missing/damaged Cracked outlet cover 22 L3 0.21 May 3 2021 8 53A4MU1) Violations: 1 Possible Pts.: 2.333 1 Unit 1-307 Totals Pts. Lost: 0.21 (0.21 Raw/0.21 Adj./0.21 Cap) Pts. Retained: 2.123 Unit 1 Unit 1-308 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Self closing device May 3 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.24 9.03AM(U1) missing Violations: 1 Possible Pts.: 2.333 1 Unit 1-308 Totals Pts. Lost: 0.236 (0.236 Raw/0.236 Adj./0.236 Cap) Pts. Retained: 2.097 Unit 1 Unit 1-309 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Shower/Tub - Hardware SHARP EDGES: Any defect that 23 L3 X NLT 0.79 May 3 2021 could pose a cutting risk 954AM(U1) HARDWARE: Self closing device May 3 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.24 9.51AM(U1) missing Living Room Smoke Detector FIRE SAFETY: Smoke detector L3 X LT o May 3 2021 inoperable/missing 9 524M(u1) Nan McKay Powered By lnspectCheck Mobile- Page 7/11 In sp e ct i o n R e s ul ts : Vi lla M ar i a - 0 5 /0 5 /2 0 2 1 (1 Unit 1-309 continued) Violations: 3 Possible Pts.: 2.333 1 Unit 1-309 Totals Pts. Lost: 1.024 (1.024 Raw/1.024 Adj./1.024 Cap) Pts. Retained: 1.31 Unit 1 Unit 1-310 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entry Door Door - Entry/Fire/Bath HARDWARE: Self closing device on door not latching to close or missing L3 0.24 May 3 2021 9 464Mu1) Violations: 1 Possible Pts.: 2.333 1 Unit 1-310 Totals Pts. Lost: 0.236 (0.236 Raw/0.236 Adj./0.236 Cap) Pts. Retained: 2.097 Unit 1 Unit 1-311 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entry Door Door - Entry/Fire/Bath HARDWARE: Self closing device on door not latching to close or missing L3 0.24 May 3 2021 940AM(u1) Violations: 1 Possible Pts.: 2.333 1 Unit 1-311 Totals Pts. Lost: 0.236 (0.236 Raw/0.236 Adj./0.236 Cap) Pts. Retained: 2.097 Unit 1 Unit 1-312 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entry Door Door - Entry/Fire/Bath HARDWARE: Self closing device on door not latching to close or missing L3 0.24 May 3 2021 9.35AM (01) Violations: 1 Possible Pts.: 2.333 1 Unit 1-312 Totals Pts. Lost: 0.236 (0.236 Raw/0.236 Adj./0.236 Cap) Pts. Retained: 2.097 na Nan McKay Powered By InspectCheck Mobile- Page 8/11 Inspection Results:. Villa Maria - 05/05/2021 Inspection Photos Entire Site Site - Grounds Vegetation - Exterior I N 2 1- Entry Door Door - Entry/Fire/Bath - 3 1- Entry Door Door - Entry/Fire/Bath - Common Area 4 1- Closet/Utility/Mechanical Electric Panel - Missing cover on roof top 5 1- Closet/Utility/Mechanical Outlets/Switches - Roof top GFCI non op, missing cover 6 1- Closet/Utility/Mechanical Outlets/Switches - Roof top GFCI missing plate/cover, GFCI non op Nan McKay Powered By lnspectCheck Mobile - Page 9/11 Inspection Results: Villa Maria - 05/05/2021 (Common Area continued) 7 1- Halls/Corridors/Stairs Door - Entry/Fire/Bath - Unit 8 Unit 1-105 - Kitchen GFCI- 11 Unit 1-204 - Bathroom 1 Shower/Tub - Hardware - Tenant requests new soap holder 14 1 Unit 1-207 - Closet/Storage Room Door - Interior - 9 Unit 1-110 - Kitchen Outlets/Switches - 12 Unit 1-205 - Health & Safety Health & Safety - Termights 10 Unit 1-201 - Kitchen Countertop - » 13 Unit 1-206 - Bathroom 1 Cabinets/Vanity - 15 Unit 1-211- Bedroom 1 Windows - 16 1 Unit 1-304 - Kitchen Cabinets - na Nan McKay Powered By lnspectCheck Mobile- Page 1 0/11 Inspection Results: Villa Maria - 05/05/2021 (Unit continued) 17 Unit 1-305 - Closet/Storage Room Door - Closet- 18 Unit 1-305 - Kitchen Cabinets - 19 Unit 1-306 - Closet/Storage Room Lighting- 20 Unit 1-306 - Entry Door Door - Entry/Fire/Bath- 21 Unit 1-306 - Living Room Outlets/Switches - 22 Unit 1-307 - Kitchen Outlets/Switches - Cracked outlet cover 23 Unit 1-309 - Bathroom 1 Shower/Tub - Hardware - na Nan McKay Powered By InspectCheck Mobile- Page 11/11 na Nan McKay , Villa Matti Date 05/06/2021 Type Pre-REAC Area *Pts.Lost(Raw) Site o Exterior o Systems 7.75 Common 18.84 *Units 7.23 Total 33.82 Pts. Lost(Adj.) *Pts. Lost(Cap) Poss. Points o o 15 o o 15 7.75 7.75 20 15.47 15 15 7.23 7.23 35 30.45 25.96 100 Score 74 Score Violations 15 o 15 o 12.25 o 7 31.79 17 74.04 25 ·pts. Lost (Raw) is the total point loss of all findings before the application of HUD scoring rules" Pts. Lost (Adj.) is the raw point loss adjusted for multiple findings of the same violation in the same building/unit per HUD rules' ps. Lost (Cap) is the adjusted point loss capped by the maximum possible point loss of each building/unit per HUD rules' Units Area Score is projected for the REAC sample size based on the average unit score" Systems 1 Location Item Deficiency Elevator Elevator General Comment Fire Protection Extinguisher General Comment FIRE SAFETY: 5-10%. of Fire Protection Extinguisher extinguishers missing/damaged/expired Notes Inspection expired 2/15/2021 on out side wheelchair elevator. Extinguisher expired in pump room Fire extinguisher in elevator room expired in 2020. Pic Sev HS LT Pts Date 1 2 3 L2 7.75 Fixed Apr 30 2021 7-114MU1) Apr 30 2021 10.214M(U1 I Apr 30 2021 7:164MU1) Violations: 1 Possible Pts.: 20 1 Systems Totals Pts. Lost: 7.75 (7.75 Raw/7.75 Adj./7.75 Cap) Pts. Retained: 12.25 Common Area Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed EXPOSED WIRES: Shut off or Roof HVAC unsecured Closet/Utility/Mechanical Electric Panel other panel cover missing or 4 L3 X LT 3.75 Apr 30 2021 panel 9.264M01) unsecured - Community Room Door - Interior HARDWARE: Interior door Auto close on fire pump 5 L2 1.69 Apr 30 2021 hardware damaged/ inoperable room door non op 7-194MU1) EXPOSED WIRES: Cover is Halls/Corridors/Stairs Electric Panel missing - exposed electrical First floor #1 staircase 6 L3 X LT 7.5 Apr 30 2021 9:374MU1) connections Laundry Room Door - Interior HARDWARE: Interior door Laundry room door auto 7 L2 1.69 Apr 30 2021 hardware damaged/ inoperable close hardware non op. 7.23A4MU1) Laundry Room Door - Interior HARDWARE: Interior door 4th floor L2 1.69 Apr 30 2021 hardware damaged/ inoperable 8:294M01) Laundry Room Door - Interior HARDWARE: Interior door Door auto closing non L2 1.69 Apr 30 2021 hardware damaged/ inoperable op 5th floor 8:.534M(U1) Restrooms Door - Interior HARDWARE: Interior door 6th floor auto closing L2 0.84 Apr 30 2021 hardware damaged/ inoperable non op 9.23A4MU1) Powered By InspectCheck Mobile - Page 1/10 In s p e c ti o n R e s u lts : V illa M a tti - 0 5 /0 6 /2 0 2 1 (1 Common Area continued) Violations: 7 Possible Pts.: 15 1 Common Area Totals Pts. Lost: 15 (18.844 Raw/15.469 Adj./15 Cap) Pts. Retained: O Unit 1 Unit 1-201 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Windows SHARP EDGES: Any defect that could pose a cutting risk 8 L3 X NLT 0.74 Apr 30 2021 7.274MU1) Violations: 1 Possible Pts.: 2.188 1 Unit 1-201 Totals Pts. Lost: 0.738 (0.738 Raw/0.738 Adj./0.738 Cap) Pts. Retained: 1.449 Unit 1 Unit 1-202 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bedroom 1 Windows SHARP EDGES: Any defect that could pose a cutting risk 9 L3 X NLT 0.74 Apr 30 2021 7:35AM(U1) Violations: 1 Possible Pts.: 2.188 1 Unit 1-202 Totals Pts. Lost: 0.738 (0.738 Raw/0.738 Adj./0.738 Cap) Pts. Retained: 1.449 Unit 1 Unit 1-203 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Shower/bathtub Bathroom 1 Shower/Tub - Hardware cannot be used due to failed Shower head non op 10 L3 0.74 Apr 30 2021 7.384MU1) hardware Violations: 1 Possible Pts.: 2.188 1 Unit 1-203 Totals Pts. Lost: 0.738 (0.738 Raw/0.738 Adj./0.738 Cap) Pts. Retained: 1.449 Unit 1 Unit 1-204 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entry Door Door - Entry/Fire/Bath HARDWARE: Self closing device on door not latching to close or missing L3 0.22 Apr 30 2021 7.524MU1) Violations: 1 Possible Pts.: 2.188 1 Unit 1-204 Totals Pts. Lost: 0.221 (0.221 Raw/0.221 Adj./0.221 Cap) Pts. Retained: 1.966 Unit 1 Unit 1-205 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Kitchen GFCI GFCI: Outlet does not test or is not operating 11 L3 X NLT 1.09 Apr 30 2021 7.474MU1) Violations: 1 Possible Pts.: 2.188 1 Unit 1-205 Totals Pts. Lost: 1.094 (1.094 Raw/1.094 Adj./1.094 Cap) Pts. Retained: 1.094 Nan McKay Powered By InspectCheck Mobile - Page 2/10 Inspection Results: Villa Matti - 05/06/2021 Unit 1 Unit 1-206 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit Apr 30 2021 7.50AMU1) Violations: O Possible Pts.: 2.188 1 Unit 1-206 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.188 Unit 1 Unit 1-207 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit Apr 30 2021 7.56A4MU1) Violations: O Possible Pts.: 2.188 1 Unit 1-207 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.188 Unit 1 Unit 1-208 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit Occupancy Vacant unit - not rent ready Apr 30 2021 7.284MU1) Violations: O Possible Pts.: 2.188 1 Unit 1-208 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.188 Unit 1 Unit 1-209 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entry Door Door - Entry/Fire/Bath HARDWARE: Self closing device on door not latching to close or missing L3 0.22 Apr 30 2021 7.294MU1) Violations: 1 Possible Pts.: 2.188 1 Unit 1-209 Totals Pts. Lost: 0.221 (0.221 Raw/0.221 Adj./0.221 Cap) Pts. Retained: 1.966 Unit 1 Unit 1-301 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit Apr 30 2021 8.01AMU1) Violations: O Possible Pts.: 2.188 1 Unit 1-301 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.188 Unit 1 Unit 1-302 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entry Door Door - Entry/Fire/Bath HARDWARE: Self closing device on door not latching to close or missing L3 0.22 Apr 30 2021 8.08A4MU1) na Nan McKay Powered By lnspectCheck Mobile - Page 3/10 Inspection Results: Villa Matti - 05/06/2021 (1 Unit 1-302 continued) Violations: 1 Possible Pts.: 2.188 1 Unit 1-302 Totals Pts. Lost: 0.221 (0.221 Raw/0.221 Adj./0.221 Cap) Pts. Retained: 1.966 Unit 1 Unit 1-303 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Kitchen Stove/Range BURNERS: One inoperable stove burner 12 L2 0.37 Apr 30 2021 8.124MU1) Violations: 1 Possible Pts.: 2.188 1 Unit 1-303 Totals Pts. Lost: 0.369 (0.369 Raw/0.369 Adj./0.369 Cap) Pts. Retained: 1.818 Unit 1 Unit 1-304 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entry Door Door - Entry/Fire/Bath HARDWARE: Self closing device on door not latching to close or missing L3 0.22 Apr 30 2021 8:13AM(U1) Violations: 1 Possible Pts.: 2.188 1 Unit 1-304 Totals Pts. Lost: 0.221 (0.221 Raw/0.221 Adj./0.221 Cap) Pts. Retained: 1.966 Unit 1 Unit 1-305 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit Apr 30 2021 8:174M(U1) Violations: O Possible Pts.: 2.188 Unit 1-305 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.188 Unit 1 Unit 1-306 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit Ap r 30 2021 8:194MU1) Violations: O Possible Pts.: 2.188 Unit 1-306 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.188 Unit 1 Unit 1-307 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit Apr 30 2021 8.224MU1) Violations: O Possible Pts.: 2.188 Unit 1-307 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.188 Na n McKay Powered By lnspectCheck Mobile- Page 4/1 O Inspection Results: Villa Matti - 05/06/2021 Unit 1 Unit 1-308 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entry Door Door - En try /Fire/B ath HARDWARE: Self closing device on door not latching to close or missing L3 0.22 Apr 30 2021 8.054MU1) Violations: 1 Possible Pts.: 2.188 1 Unit 1-308 Totals Pts. Lost: 0.221 (0.221 Raw/0.221 Adj./0.221 Cap) Pts. Retained: 1.966 Unit 1 Unit 1-309 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit Apr 30 2021 8:234MU1) Violations: O Possible Pts.: 2.188 Unit 1-309 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.188 Unit 1 Unit 1-401 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No Issues/Vi olations No observed deficiencies in entire unit Apr 30 2021 8.294MU1) Violations: O Possible Pts.: 2.188 Unit 1-401 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.188 Unit 1 Unit 1-402 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit Apr 30 2021 8.314Mu1) Violations: O Possible Pts.: 2.188 1 Unit 1-402 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.188 Unit 1 Unit 1-403 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No Issues/Vi olations No observed deficiencies in entire unit Apr 30 2021 8:33A4MU1) Violations: O Possible Pts.: 2.188 1 Unit 1-403 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.188 Unit 1 Unit 1-404 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No Issues/Vi olations No observed deficiencies in entire unit Apr 30 2021 8.384M(U1) n a Powered By InspectCheck Mobile - Page 5/10 In sp e ct i on R e s ul ts: Villa Matti - 05/06/2021 (1 Unit 1-404 continued) Violations: O Possible Pts.: 2.188 1 Unit 1-404 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.188 Unit 1 Unit 1-405 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit Apr 30 2021 10:21AM(U1 I Violations: O Possible Pts.: 2.188 Unit 1-405 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.188 Unit 1 Unit 1-406 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit Apr 30 2021 8.404MU1) Violations: O Possible Pts.: 2.188 1 Unit 1-406 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.188 Unit 1 Unit1-407 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entry Door Door - Entry/Fire/Bath HARDWARE: Self closing device on door not latching to close or missing L3 0.22 Apr 30 2021 8:404MU1) Violations: 1 Possible Pts.: 2.188 1 Unit 1-407 Totals Pts. Lost: 0.221 (0.221 Raw/0.221 Adj./0.221 Cap) Pts. Retained: 1.966 Unit 1 Unit 1-408 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit Apr 30 2021 8:454MU1) Violations: O Possible Pts.: 2.188 1 Unit 1-408 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.188 Unit 1 Unit1-409 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entry Door Door - Entry/Fire/Bath HARDWARE: Self closing device on door not latching to close or missing L3 0.22 pr 30 2021 8.464MU1) Violations: 1 Possible Pts.: 2.188 1 Unit 1-409 Totals Pts. Lost: 0.221 (0.221 Raw/0.221 Adj./0.221 Cap) Pts. Retained: 1.966 na Nan MKay Powered By InspectCheck Mobile- Page 6/10 In s p e c tio n R e s u lts : Vi ll a M a tti - 0 5 /0 6 /2 0 2 1 Unit 1 Unit 1-501 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No Issues/Violation s No observed deficiencies in entire unit Ap r 30 2021 8.54AMu1) Violations: O Possible Pts.: 2.188 1 Unit 1-501 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.188 Unit 1 Unit 1-502 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Self closing device Apr 30 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.22 8.544MU1) missing VALVE: Pressure relief valve Tube needs to be within Ap r 30 2021 Local Systems Water Heater missing or does not extend to 6 inches of floor 13 L3 X NLT 1.09 10.20A4M(U1 within 18in. of floor I Violations: 2 Possible Pts.: 2.188 1 Unit 1-502 Totals Pts. Lost: 1.315 (1.315 Raw/1.315 Adj./1.315 Cap) Pts. Retained: 0.872 Unit 1 Unit 1-503 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit Ar 30 2021 9.004MU1) Violations: O Possible Pts.: 2.188 1 Unit 1-503 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.188 Unit 1 Unit 1-504 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit Housekeeping HOUSEKEEPING: Excessive Clutter or Disorganized Area unable to complete full inspection 14 Ap r 30 2021 9.02A4M(U1) Violations: O Possible Pts.: 2.188 1 Unit 1-504 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.188 Unit 1 Unit 1-505 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Kitchen GFCI GFCI: Protected Outlet is missing near sink per local code Ap r 30 2021 9.054MU1) Violations: O Possible Pts.: 2.188 1 Unit 1-505 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.188 Unit 1 Unit 1-506 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit Apr 30 2021 9.094MU1) na Nan McKay Powered By InspectCheck Mobile- Page 7/10 In sp ect ion R e sul ts:. Vi lla M a tti - 05 /0 6/20 2 1 (1 Unit 1-506 continued) Violations: O Possible Pts.: 2.188 1 Unit 1-506 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.188 Unit 1 Unit 1-507 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit Apr 30 2021 9:12A4M U1) Violations: O Possible Pts.: 2.188 Unit 1-507 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 2.188 Unit 1 Unit 1-508 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Self closing device Apr 30 2021 Entry Door Door - Entry/Fire/Bath on door not latching to close or L3 0.22 9:134MU1) missing HARDWARE: Closet door Kitchen Door - Closet hardware 16 L1 0.06 Apr 30 2021 9.144MU1) damaged/missing/inoperable Kitchen GFCI GFCI: Protected Outlet is missing 17 Apr 30 2021 near sink per local code 9:164Mu1) Violations: 2 Possible Pts.: 2.188 1 Unit 1-508 Totals Pts. Lost: 0.277 (0.277 Raw/0.277 Adj./0.277 Cap) Pts. Retained: 1.911 Unit 1 Unit 1-509 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Kitchen Range HoodNent Fan HOODVENT: Inoperable - does not function Vent fan non op L3 0.41 Apr 30 2021 9:184M(01) Violations: 1 Possible Pts.: 2.188 1 Unit 1-509 Totals Pts. Lost: 0.41 (0.41 Raw/0.41 Adj./0.41 Cap) Pts. Retained: 1.777 na Nan McKay Powered By lnspectCheck Mobile - Page 8/10 Inspection Results: Villa Matti - 05/06/2021 Inspection Photos Systems 1- Elevator Elevator - Inspection expired 2/15/2021 on out side wheelchair elevato 2 1-Fire Protection Extinguisher - Extinguisher expired in pump room 3 1-Fire Protection Extinguisher - Fire extinguisher in elevator room expired in 2020. Common Area 4 1- Closet/Utility/Mechanical Electric Panel - Roof HVAC unsecured panel i • @o 5 1- Community Room Door - Interior - Auto close on fire pump room door non op 6 1- Halls/Corridors/Stairs Electric Panel - First floor #1 staircase 7 1-Laundry Room Door - Interior - Laundry room door auto close hardware non op. na Nan McKay Powered By lnspectCheck Mobile- Page 9/1 O Inspection Results: Villa Matti - 05/06/2021 Unit 8 Unit 1-201 - Bathroom 1 Windows- 11 1 Unit 1-205 - Kitchen GFCI- 14 Unit 1-504 - Entire Unit Housekeeping - unable to complete full inspection 9 Unit 1-202 - Bedroom 1 Windows- 12 Unit 1-303 - Kitchen Stove/Range - 10 Unit 1-203 - Bathroom 1 Shower/Tub - Hardware - Shower head non op ts±Re Mg • 1- ·f··- -_-- ,,.~, Hl ' • 5 13 Unit 1-502 - Local Systems Water Heater - Tube needs to be within 6 inches of floor 15 Unit 1-505 - Kitchen GFCI - 16 Unit 1-508 - Kitchen Door - Closet - 17 Unit 1-508 - Kitchen GFCI - 18 Unit 1-509 - Kitchen Range HoodNent Fan - Vent fan non op na Nan McKay Powered By InspectCheck Mobile- Page 10/10 nn Nan McKay +, • t Crespi Park Date 04/26/2021 Type Pre-REAC Area *Pts. Lost(Raw) Site 2.11 Exterior 6.04 Systems o Common 4.01 Units 19.89 Total 32.05 Pts. Lost(Adj.) *Pts. Lost(Cap) Poss. Points 2.11 2.11 15 6.04 4.79 15 o o 20 3.16 3.16 15 19.89 15.96 35 31.21 20.03 100 Score 80 Score Violations 12.89 1 10.22 4 20 o 11.84 6 25.03 17 79.97 28 ·Pg. Lost (Raw) is the total point loss of all findings before the application of HUD scoring rules" ps. Lost (Adj.) is the raw point loss adjusted for multiple findings of the same violation in the same building/unit per HUD rules" *Pts. Lost (Cap) is the adjusted point loss capped by the maximum possible point loss of each building/unit per HUD rules" Units Area Score is projected for the REAC sample size based on the average unit score" Entire Site Site Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Grounds Vegetation VEGETATION: Vegetation contacts unintended surface (not including minor contact with fence) I no visible damage building number 3, tree touching roof back right. L2 2.11 Apr 27 2021 10:31AM(U1 ) Violations: 1 Possible Pts.: 15 Site Totals Pts. Lost: 2.109 (2.109 Raw/2.109 Adj./2.109 Cap) Pts. Retained: 12.891 Exterior 1 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed TRIPPING: Any obstruction or Apr 27 2021 Health & Safety Health & Safety defect in a surface that causes Side walk near street 1 L3 X NLT o 8.57A4MU1) tripping SOFFIT/FASCIA: Damage Apr 27 2021 Roofing Soffit/Fascia materials - no opportunity for 2 L1 1.04 8:59AM(U1) water penetration Violations: 2 Possible Pts.: 7.5 1 Exterior Totals Pts. Lost: 1.035 (1.035 Raw/1.035 Adj./1.035 Cap) Pts. Retained: 6.465 Exterior 2 Location Electrical Entry Door Item Deficiency Notes Pic Sev HS LT Pts Date Fixed EXPOSED WIRES: Unsecured Electric Panel cover/wires/connections creating a 3 L3 X LT 3.45 Apr 27 2021 9:404MU1) hazard Door - Security/Storm HARDWARE: Security door Auto closing non op. L3 X NLT 1.55 Apr 27 2021 hardware, or other damage 9:484Mu1) Lighting Lighting GLOBE: Light globe or Lens missing or damaged Apr 27 2021 9:.43A4M(01) Violations: 2 Possible Pts.: 3.75 2 Exterior Totals Pts. Lost: 3.75 (5.003 Raw/5.003 Adj./3.75 Cap) Pts. Retained: O Powered By InspectCheck Mobile - Page 1/7 In s p e c tio n R e s u lts : C re s p i P ar k - 0 4 /2 6 /2 0 2 1 Common Area Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Halls/Corridors/Stairs Lighting GLOBE: Light globe or Lens missing or damaged Stair case to unit 6-8 aux light non op. Apr 27 2021 9.284MU1) Violations: O Possible Pts.: 7.5 1 Common Area Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 7.5 Common Area 2 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Halls/Corridors/Stairs Door - Entry/Fire/Bath HARDWARE: Door hardware or auto closing between L3 0.84 Ap r 27 2021 lock damaged/ inoperable 10b and 11b non op 9.534M(u1) Halls/Corridors/Stairs Walls HOLE: Hole/missing tile/damaged 5 L2 0.42 Apr 27 2021 area more than 8.5x11in. 9.474M(U1) Violations: 2 Possible Pts.: 3.75 2 Common Area Totals Pts. Lost: 1.266 (1.266 Raw/1.266 Adj./1.266 Cap) Pts. Retained: 2.484 Common Area 3 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Self closing device Apr 27 2021 Halls/Corridors/Stairs Door - Entry/Fire/Bath on door not latching to close or front door L3 0.84 10:11AM(U1 missing ) HARDWARE: Self closing device Apr 27 2021 Halls/Corridors/Stairs Door - Entry/Fire/Bath on door not latching to close or rear door L3 0.84 10:11AMUI missing I HOLE: Hole/missing pr 27 2021 Halls/Corridors/Stairs Walls tile/damaged/non-workmanlike 6 L 1 0.21 10.124 M(u1 repair 1in.-8.5x11 in. I SHARP EDGES: Any defect that Apr 27 2021 Health & Safety Health & Safety Sencond floor window. 7 L3 X NLT 0.84 10:274M(U1 could pose a cutting risk ) 3 Common Area Totals Violations: 4 Possible Pts.: 3.75 Pts. Lost: 1.898 (2.742 Raw/1.898 Adj./1.898 Cap) Pts. Retained: 1.852 Unit 1 Unit 1-1 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit Occupancy Could not enter unit (enter reason below) Covid Ar 27 2021 9:124MU1) Violations: O Possible Pts.: 3.5 1 Unit 1-1 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 3.5 Unit 1 Unit 1-2 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Kitchen GFCI GFCI: Protected Outlet is missing near sink per local code Apr 27 2021 9.044MU1) na Nan McKay Powered By InspectCheck Mobile - Page 2/7 Inspection Results: Crespi Park - 04/26/2021 (1 Unit 1-2 continued) Violations: O Possible Pts.: 3.5 1 Unit 1-2 Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 3.5 Unit 1 Unit 1-3 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed CABINETS: 10-50% of Kitchen Cabinets cabinets/doors/shelves missing or 8 L2 0.33 Apr 27 2021 9:164MU1) laminate is separating Violations: 1 Possible Pts.: 3.5 1 Unit 1-3 Totals Pts. Lost: 0.328 (0.328 Raw/0.328 Adj./0.328 Cap) Pts. Retained: 3.172 Unit 1 Unit 1-4 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entry Door Door - Security/Storm HARDWARE: Security door Missing weather striping. 9 L3 X NLT 0.35 Apr 27 2021 hardware, or other damage 9:114MU1) EXPOSED WIRES: Unsecured Kitchen Lighting cover/wires/connections creating a 10 L3 X LT 2.63 Apr 27 2021 9.09A4MU1) hazard Violations: 2 Possible Pts.: 3.5 1 Unit 1-4 Totals Pts. Lost: 2.979 (2.979 Raw/2.979 Adj./2.979 Cap) Pts. Retained: 0.521 Unit 1 Unit 1-5 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Local Systems Electric Panel General Comment Apr 27 2021 9.22AMU1) Local Systems Electric Panel BLOCKED: Blocked access to L3 X NLT 0.79 Apr 27 2021 electric panel or fuse panel 9.224MU1) VAL VE: Pressure relief valve Local Systems Water Heater missing or does not extend to lnproperly installed 11 L3 X NLT 1.75 Apr 27 2021 9:22A4MU1) within 18in. of floor Violations: 2 Possible Pts.: 3.5 Unit 1-5 Totals Pts. Lost: 2.538 (2.538 Raw/2.538 Adj./2.538 Cap) Pts. Retained: 0.963 Unit 1 Unit 1-6 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HARDWARE: Shower/bathtub Bathroom 1 Shower/Tub - Hardware cannot be used due to failed Tub diverter non op. L3 1.18 Apr 27 2021 9.394MU1) hardware Kitchen Ceiling WATER STAIN: Evidence of 12 L3 0.18 Ap r 27 2021 leak/mold/mildew > 4sf 9:37AM01) Violations: 2 Possible Pts.: 3.5 1 Unit 1-6 Totals Pts. Lost: 1.356 (1.356 Raw/1.356 Adj./1.356 Cap) Pts. Retained: 2.144 na Nan McKay Powered By lnspectCheck Mobile- Page 3f7 Inspection Results: Crespi Park - 04/26/2021 Unit 1 Unit 1-7 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed COVERS: Outlet/switch has Kitchen Outlets/Switches broken/missing cover plate - 13 L3 X LT 2.63 pr 27 2021 9.27A4Mu1) exposing wires EXPOSED WIRES: Unsecured Kitchen Range HoodNent Fan cover/wires/connections creating a 14 L3 X LT 2.63 Apr 27 2021 9:25AM(U1) hazard Violations: 2 Possible Pts.: 3.5 1 Unit 1-7 Totals Pts. Lost: 3.5 (5.25 Raw/5.25 Adj./3.5 Cap) Pts. Retained: O Unit 1 Unit 1-8 Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 GFCI GFCI: Outlet does not test or is L3 X NLT 1.75 Apr 27 2021 not operating 9:32AMu1) Bathroom 1 Toilet FIXT URE: To ilet is loose L2 1.31 Apr 27 2021 9:.324MU1) EGRESS: Emergency fire exit Apr 27 2021 Entry Door Door - En try/Fire/Bath blocked/un usable - blocked 15 L3 X LT 2.63 9:33AM(U1) egress Violations: 3 Possible Pts.: 3.5 1 Unit 1-8 Totals Pts. Lost: 3.5 (5.688 Raw/5.688 Adj./3.5 Cap) Pts. Retained: O Unit 2 Unit 2-10B Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No Issues/Vi olations No observed deficiencies in entire unit Apr 27 2021 9:56AM(U1) Violations: O Possible Pts.: 3.5 2 Unit 2-10B Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 3.5 Unit 2 Unit 2-11B Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit Apr 27 2021 9.524MU1) Violations: O Possible Pts.: 3.5 2 Unit 2-11B Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 3.5 Unit 2 Unit 2-20B Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Apr 27 2021 Entire Unit Occupancy No key available 10.01AM(U1 I 2 Unit 2-20B Totals Violations: O Possible Pts.: 3.5 Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 3.5 na Nan McKay Powered By lnspectCheck Mobile- Page 4/7 Insp e ct i o n Results: Crespi Park - 04/26/2021 Unit 2 Unit 2-21B Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit No lssuesNiolations No observed deficiencies in entire unit Apr 27 2021 10.004M(U1 I Violations: O Possible Pts.: 3.5 2 Unit 2-21B Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 3.5 Unit 3 Unit 3-10C Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Bathroom 1 Toilet FIXTURE: Toilet is loose L2 Apr 27 2021 1.31 10:184MU1 ) Violations: 1 Possible Pts.: 3.5 3 Unit 3-10C Totals Pts. Lost: 1.313 (1.313 Raw/1.313 Adj./1.313 Cap) Pts. Retained: 2.188 Unit 3 Unit 3-11C Location Item Deficiency Notes Bedroom 1 Smoke Detector Halls/Corridors/Stairs Smoke Detector FIRE SAFETY: Smoke detector inoperable/missing FIRE SAFETY: Smoke detector inoperable/missing Violations: 2 Possible Pts.: 3.5 3 Unit3-11CTotals Pts. Lost: O (O Raw/O Adj.iO Cap) Pic Sev HS LT Pts Date Fixed Apr 27 2021 L3 X LT o 10:154MU 1 I Apr 27 2021 L3 X LT o 10:15A4M(U1 I Pts. Retained: 3.5 Unit 3 Unit 3-20Cc Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed HOLE: Interior door has hole Apr 27 2021 Bedroom 1 Door - Interior greater than 1 in. L3 0.35 10.24A4M (U1 ) HARDWARE: Door off track Apr 27 2021 Closet/Storage Room Door - Closet and/or dama ged door track L1 0.09 10:234M(U1 ) Violations: 2 Possible Pts.: 3.5 3 Unit 3-20C Totals Pts. Lost: 0.443 (0.443 Raw/0.443 Adj./0.443 Cap) Pts. Retained: 3.057 Unit 3 Unit 3-21C Location Item Deficiency Notes Pic Sev HS LT Pts Date Fixed Entire Unit Occupancy Vacant unit - not rent ready Apr 27 2021 10.264M(U1 ) Violations: O Possible Pts.: 3.5 3 Unit 3-21 C Totals Pts. Lost: O (O Raw/O Adj.iO Cap) Pts. Retained: 3.5 na Nan McKay Powered By InspectCheck Mobile- Page 5/7 Inspection Results: Crespi Park - 04/26/2021 Inspection Photos Exterior 1- Health & Safety Health & Safety - Side walk near street 2 1- Roofing Soffi/F ascia - 3 2- Electrical Electric Panel - 4 2-Li ghting Li ghting - Common Area a5 5 2- Halls/Corridors/Stairs Walls- 6 3- Halls/Corridors/Stairs Walls- 7 3- Health & Safety Health & Safety - Sencond floor window. na Nan McKay Powered By lnspectCheck Mobile- Page 6/7 Inspection Results: Crespi Park - 04/26/2021 Unit 8 Unit 1-3 - Kitchen Cabinets - 11 Unit 1-5 -Loca l Systems Water Heater - Inproperly installed 9 Unit 1-4- Entry Door Door - Security/Storm - Missing weather striping. 10 Unit 1-4- Kitchen Lighting - 12 Unit 1-6 - Kitchen Ceiling - 13 1 Unit 1-7 - Kitchen Outlets/Switches - 14 Unit 1-7 - Kitchen Range Hood/Vent Fan - 15 Unit 1-8- Entry Door Door - Entry/Fire/Bath - na Nan McKay Powered By InspectCheck Mobile- Page 7/7